Tender For Construction Of Rcc Ohsr Of 75000 Ltr Capacity, Height 30.88 Mtr Upto Fsl, Repair Of Pump Chamber, Distribution System, Development Of Water Works, House Connections, Solar Power Plant Etc. At Water Supply Scheme Sanghol, Block Khamano D, Fatehgarh Sahib-Punjab

Water Supply And Sanitation Department-WSSD has published Tender For Construction Of Rcc Ohsr Of 75000 Ltr Capacity, Height 30.88 Mtr Upto Fsl, Repair Of Pump Chamber, Distribution System, Development Of Water Works, House Connections, Solar Power Plant Etc. At Water Supply Scheme Sanghol, Block Khamano D. Submission Date for this Tender is 17-07-2023. Solar Power Plants Tenders in Fatehgarh Sahib Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

38316380
Corrigendum : Tender For Construction Of Rcc Ohsr Of 75000 Ltr Capacity, Height 30.88 Mtr Upto Fsl, Repair Of Pump Chamber, Distribution System, Development Of Water Works, House Connections, Solar Power Plant Etc. At Water Supply Scheme Sanghol, Block Khamano D
Open Tender
Indian
Punjab
Fatehgarh Sahib
17-07-2023

Tender Details

Construction Of Rcc Ohsr Of 75000 Ltr Capacity, Height 30.88 Mtr Upto Fsl, Repair Of Pump Chamber, Distribution System, Development Of Water Works, House Connections, Solar Power Plant Etc. At Water Supply Scheme Sanghol, Block Khamano Distt. Fgs

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Jun-2023 Date extended Date 17-07-2023

Key Value

Document Fees
Refer document
EMD
INR 317000.0 /-
Tender Value
INR 1.58 Crore /-

BOQ Items

Name of Work: Construction of Circular type RCC OHSR of75000 ltr Capacity, having height 30.88 mtr upto FSL, Repair of Pump Chamber, Distribution System, C.I Delivery Main, Development of Water Works, House Connections, Solar Power Plant etc.at Water Supply Scheme Sanghol, Block Khamano District Fatehgarh Sahib
Sl. No. Item Description
1Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2021 (Type-A), including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects.
2160 mm o/d PVC pipe 10 kg cm2
3Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
4150mm i/d
5Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department (1 no. each of size 0.9m x 0.9m
6Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications.
7Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
8Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
9Applying priming coat with methal primer on new steel or iron work incluing preparation of surface and Painting two coats with ready mixed paint for metallic surfaces in all shades on steel or iron work with special quality paint.
10White washing 3 coats inside of pump chamber,
11Finishing walls with cement based soluable such as snowecem, robbiacem etc. on old work one coat to give an even shade
12Distempering with dry distemper of approved manufacture two or more coats over one priming coat to give an even shade
13Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make b) Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area
14Hollock wood doors shutter windows including Hinges, Screws, Chocks Cleats, Stops and Cords etc. complete fixed in position (double Leaf) @ Paneledglazed or glazed and paneled
15Construction of 1 Nos. New RCC OHSR 75 KL capacity having height of 30.88 m upto from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing DI K-9 D/F expansion joints conforming to (IS-9523 with latest amendments) or latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed typical drawing. Duck foot bends, Conforming (IS-9523 with latest amendments)and DI K-9 D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow DI K-9 double flanged pressure pipes centrifugallycast as per IS 8329 with latest amendments duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminum ladder inside, steel ladder outside tank of the OHSR including testing of soil bearing capacity tested from the reputed institute such as PEC Chandigarh/TTT Sector-26, Chandigarh, GNEC/Ludhiana/Thapar Instituted of Engineer and Technology Patiala Complete in all respect. SBC Shall be tested in the presence of Engineer or his representative as per specifications. (The specifications & drawing are based on safe bearing capacity of soil is not less than 8.75 tone per Sqm. In case the safe bearing capacity of soil is less than 8.75 tone per Sqm, The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Premium including overflow haudi,including providing & fixing Water Level indicating system and Construction of plinth protection around the OHSR including foundation depth, earth filling, CC 1:8:16 with 40mm stone aggregate & conglomerate floor 40mm with CC 1:2:4 as per DWSS specifications. Providing & applying integral crystalling slurry of hydrophilic in in nature for water proofing management for vertical and horizontal surface and swell able type water stop tape. providing & applying integral crystalling of hydrophilic in in nature for water proofing management for vertical and horizontal surface and swellable type water stop tape.
16Provision for Extra Height of OHSR i.e 8.88 x 4 Columns
17Extra for Carriage of Fine & Course aggregate i.e Sand & Bajri from query Burj Kotian (Zirakpur) towater works sites beyond 5 km. (Aug: lead for sandand Bajri 60 km) analysis attached
18Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects.- On Existing OHSR
19Repair of Expension Joints xof Existing OHSR Complete in all respect.
20Construction of Plinth Protection around OHSR with masonary toe wall and inside earthfilling with lead 5 kms complete in all respects. 1.00 lakh ltr capacity
21Painting of vertical pipes of esisting OHSR sComplete in all respects.
22Providing & Fixing ventilator jali and manhjole covere complete in all respects.(existing OHSR)
23Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2021 (Type-A), including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects.
24PVC pipe63mm o/d 6kg cm2
25Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2021 (Type-A), including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects.
26PVC pipe90mm o/d 6kg cm2
27PVC pipe110mm o/d 6kg cm2
28PVC pipe160mm o/d 6kg cm2
29PVC pipe 210 mm o/d 6kg cm2
30PVC pipe 260 mm o/d 6kg cm2
31Dismantling of cement concrete 80mm thick cement concrete 1:2:4 over 100mm thick 1:8:16 and making good the same to its original condition complete in all respects.
3263mm o/d to 160 mm o/d
33Taking out of Interlock Tiles flooringand relaying with a taking out interlock tiles includingsand grouting etc complete in all respect.
34upto 63 mm o/d
35upto 90 mm o/d
36upto 110 mm o/d
37upto 160 mm o/d
38Dismantteling brick or flanged stone flooring without concrete base as per CSR item 8.19 and bry brick on edge on paving with dismantteled bricks including sand grouting complete in all respects.
39upto 63 mm o/d
40upto 90 mm o/d
41upto 110 mm o/d
42upto 160 mm o/d
43Hand boring Horizontly for crossing of pipe under road or any other obstacle by using Auger/Bocki method.Including excavation , stringing and jointing of pipe upto 160mm complete
44Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge)
4580 mm I/d
46100 mm I/d
47150 mm I/d
48200 mm I/d
49250 mm I/d
50Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health departmentWith each of Size 0.6m x 0.6m
51Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department With each of Size 0.9m x 0.9m
52Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004in pipe lines includingjointing & cost of Nut Bolt , rubber insertion etc.complete.
53Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all carriages complete. C.I Double air valve (Size 80mm)
54Connection of Existing Pipeline with Proposed Pipeline including all material and labour complete in all respects.
55Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing
56Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing.
57Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing
58Repair of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing.
59Repair of masonry gate pillaras per standard Drawingcomplete in all respects
60Providing & laying 50mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and approved size and design/ shape laid in ordinary grey color and pattern over and including 50mm thick compacted bed of course sand, filling the joints with fine sand etc. and including cost of carriage all complete as per directions of Engineerin -charge with pre cast kerb and earthfilling inside the water works including precase kerb both sides complete in all respect.
61Providing & fixing MS Sign Board as per standard size of DWSS.
62Construction of V-Notch Haudi. (size 1.80 m x 0.90 m) excluding cost V-Notch as per standard design & drawings of public health department.
63Carriage of material i.e sand and bajri including loading and unloading complete in all respect. Avg. lead 0 to 60 kms.
64Providing proposed water connection to house hold up to wall with Providing MDPE pipe PN 16, 20 mm 2m and G.I Pipe ( as per IS 1239) B- Class, Premium make such as Jindal Hissar as approved by Engineer Incharge 15mm i/d=2.5 mtr, including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with c.i bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved makecomplete for achieving optimal service delivery at least 10 hours water supply
65Providing, fixing, installing, commissioning Solar Panel Energy System (Polycrystline) for for ampount of electric power required for running electric motor and other appliances such as fan, tube, bulb etc. in water works site including Bi-directional meter and inverter of suitable capacity as per guidlines issued by PEDA complete in all respect.
66Weeding out of lawn, where weeds are up to 50%, by removal of all weeds and other wild growth with roots by forking including disposal of garden rubbish with all loads and lifts complete.
67Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with mixture of good earth and manure 1:1, mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed
68Digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed farm yard manure @ 30% of pit volume and insecticide for termite control
69Supplying and planting permanent trees in prepared pits and watering
70Planting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row.
71Planting Rose beds including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, triangular planting of sapling at 60cm distance from plant to plant and row to row.
72MS circular tree guard 60 cm dia and 1.8 mtrs. height above ground level formed of 4 Nos. of angle irons of 25 x 25 x 3 mm 2.10 m long, 4 Nos. 25mm x 3mm, 1.5 m long vertical MS flat welded to 3 no. 25 mm x 6mm M.S flat iron rings in two halves bolted together with 8mm dia & 30 mm long bolts and fixing 250 mm X 100 mm iron plate, fixed in ground with 1:2:4 cement concrete, complete in all respects
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail