}

Tender For Supply And Installation Of 4 Nos Of 6M Gi Pole With 3 No. Of 50 W Led Flood Lights, 1 No Of 6M Gi Pole With 1 No. Of 150 W Led Flood Light And 5 Nos Of 5M Gi Pole With 2 No. Of 50 W Led Flood Lights At Brdc Bekkal, Kanhangad, Kasargode Dis, kasargode-Kerala

Steel Industrials Kerala Limited has published Tender For Supply And Installation Of 4 Nos Of 6M Gi Pole With 3 No. Of 50 W Led Flood Lights, 1 No Of 6M Gi Pole With 1 No. Of 150 W Led Flood Light And 5 Nos Of 5M Gi Pole With 2 No. Of 50 W Led Flood Lights At Brdc Bekkal, Kanhangad, Kasargode Dis. Submission Date for this Tender is 03-07-2023. Halogen Light Tenders in kasargode Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

38315981
Corrigendum : Tender For Supply And Installation Of 4 Nos Of 6M Gi Pole With 3 No. Of 50 W Led Flood Lights, 1 No Of 6M Gi Pole With 1 No. Of 150 W Led Flood Light And 5 Nos Of 5M Gi Pole With 2 No. Of 50 W Led Flood Lights At Brdc Bekkal, Kanhangad, Kasargode Dis
Open Tender
Indian
Kerala
kasargode
03-07-2023

Tender Details

Supply And Installation Of 4 Nos Of 6M Gi Pole With 3 No. Of 50 W Led Flood Lights, 1 No Of 6M Gi Pole With 1 No. Of 150 W Led Flood Light And 5 Nos Of 5M Gi Pole With 2 No. Of 50 W Led Flood Lights At Brdc Bekkal, Kanhangad, Kasargode District Supply And Installation Of 4 Nos Of 6M Gi Pole With 3 No. Of 50 W Led Flood Lights, 1 No Of 6M Gi Pole With 1 No. Of 150 W Led Flood Light And 5 Nos Of 5M Gi Pole With 2 No. Of 50 W Led Flood Lights At Brdc Bekkal, Kanhangad, Kasargode District

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Jun-2023 Date Date 03-07-2023

Key Value

Document Fees
INR 924 /-
EMD
INR 9793.0 /-
Tender Value
INR 3.91 Lakhs /-

BOQ Items

Name of Work: Supply and Installation of 4 Nos of 6m GI pole with 3 No. of 50 W LED Flood Lights, 1 No of 6m GI pole with 1 No. of 150 W LED Flood Light and 5 Nos of 5m GI pole with 2 No. of 50 W LED Flood Lights at BRDC Bekkal, Kanhangad, Kasargode District
Sl. No. Item Description
1Installation of 4 Nos. of 6m GI pole with 3 Nos of 50W LED Floods Lights
2od78088/2023_2024 Supply installation, testing and commissioning of 80mm dia PU coated GI Pole, pole thickness- 3mm or nearest available, 8mm thick square base plate welded to pole and round arm bracket having 0.5 mt dia/arm and clamp including connector etc. complete 6 Meters.
3od82414/2023_2024 Supply Conveyance, installation, testing and commissioning of 50 W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
4od82577/2023_2024 Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing
masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required
5od83747/2023_2024 Supply and Installation of dust and vermin proof, 1 phase sintex meter board(GS-MB-375) and to fix KSEB meters, fuse units, CT etc., as required including fixing it on wall, making good the damages colour washing etc., as required
6od83930/2023_2024 Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable
72.14.2Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
82.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
92.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1090.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
1190.16.4.2 Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip
1290.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)
1390.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
1490.12.5.3 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
1590.12.9.2 Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
169.1.2Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
17Civil Works
182.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
194.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
205.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
215.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2210.25.2Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
235.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
242.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m
2513.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
26od91234/2023_2024 Supply and fixing of Name Board with Angles, Flats, Square pipe, ACP Sheet including Nut & Bolt. all complete as per direction of Engineer in charge Complete
27Installation of 1 No. of 6m GI pole with 1 no. of 150W LED Flood Light
28od78088/2023_2024 Supply installation, testing and commissioning of 80mm dia PU coated GI Pole, pole thickness- 3mm or nearest available, 8mm thick square base plate welded to pole and round arm bracket having 0.5 mt dia/arm and clamp including connector etc. complete 6 Meters.
2990.15.4.9 Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
30od82577/2023_2024 Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing
masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
31od83747/2023_2024Supply and Installation of dust and vermin proof, 1 phase sintex meter board(GS-MB-375) and to fix KSEB meters, fuse units, CT etc., as required including fixing it on wall, making good the damages colour washing etc., as required
32od87805/2023_2024Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable
332.14.2Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
342.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
352.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
3690.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
3790.16.4.2 Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip
3890.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
3990.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
4090.12.9.2 Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
419.1.2Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
42Civil Works
432.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
444.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
455.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
465.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
4710.25.2Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
485.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
492.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
5013.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
51od91234/2023_2024Supply and fixing of Name Board with Angles, Flats, Square pipe, ACP Sheet including Nut & Bolt. all complete as per direction of Engineer in charge Complete
52Installation of 5 Nos of 5m GI Pole with 2 Nos of 50 W LED Flood Lights
53od87809/2023_2024 Supply installation, testing and commissioning of 80mm dia PU coated GI Pole, pole thickness- 3mm or nearest available, 8mm thick square base plate welded to pole and round arm bracket having 0.5 mt dia/arm and clamp including connector etc. complete 5 Meters.
54od89127/2023_2024Purchase and Fixing 3mm thick GI- non Corrosive type clamps over 80mm dia GI poles at the places where RCC foundation is unavailable.
55od82414/2023_2024Supply Conveyance, installation, testing and commissioning of 50 W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
56od82577/2023_2024 Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing
masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
57od83747/2023_2024Supply and Installation of dust and vermin proof, 1 phase sintex meter board(GS-MB-375) and to fix KSEB meters, fuse units, CT etc., as required including fixing it on wall, making good the damages colour washing etc., as required.
58od83930/2023_2024Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable.
592.14.2Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
602.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
612.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
6290.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
6390.16.4.2 Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip
6490.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
6590.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
6690.12.5.3 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
6790.12.9.2 Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
689.1.2Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
69Civil Works
70od91234/2023_2024 Supply and fixing of Name Board with Angles, Flats, Square pipe, ACP Sheet including Nut & Bolt. all complete as per direction of Engineer in charge Complete
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail