Health And Family Welfare Department has published Purchase Of Instruments/Equipments/Chemicals/ Glasswares /Kits/Models Etc. For Pathology Department (Part 1)- Autoclave - Vertical, Fully Automatic,Autoclave - Vertical, Fully Automatic,Autoclave - Vertical, Fully Automatic,Autoclave Double Drum Vertical. Submission Date for this Tender is 12-07-2023. Laboratory Blending and Dispersing Equipment Tenders in Ahmadabad Gujarat. Bidders can get complete Tender details and download the document.
Sl. No. | Item Title | specification / Unit |
1 | Autoclave - vertical, fully automatic | • size Medium • The unit comprises of steam jacket electrically heated, inner chamber and outer cover is made of stainless steel and duly insulated with high density mineral wool from the inner chamber and fitted with stable legs. • Should works on 3-phase, 440V, A/C, 50HZ supply. • Application specific integrated chip Microprocessor controller. • Provided with RS 232 output • Fitted with pressure control switch • Fitted with low water level cut off device. • The chamber is made of heavy gauge, stainless steel, fitted with stainless steel forged ring lid and two safety valve of stainless steel. • Supplied with pedal lifting device. • The unit has been fitted with pressure gauge, water outlet valve and air inlet valve, stainless steel steam condenser, tube with stainless steel eject valve. • The steam generator is made out of stainless steel heavy gauge and water draining valve. • Inner drum size : 450 x 600 mm • Accessories : Timer, 2 lid sealed gasket, Autoclave indicator strip, 2 heating coils. • Company should provide Good manufacturing product (GMP)/ WHO certificate & ISO certificate/FDA approved along with tender. • Should have ISI mark. • Should have good consumer base in Gujarat. • It is preferable, if equipment is approved by any apex Govt. institute in India. • It is preferable, if equipment have good rapport in commercial market since last 3 year. • It is preferable that 5 years AMC rate is provided & AMC rate should not more than 10 % of original the cost. • It is more preferable that company should provide CMC for the equipment • Permanent service engineer should be posted in Gujarat and attend to complaints and rectify them within 48 hours. • Comprehensive and full training of all users by suppliers for operating the equipment. • The company should supply the list of institution where the equipments are being used. • Authority letter from Manufacturer is mandatory. • For imported item, CE certificate is must. |
2 | Autoclave - vertical, fully automatic | • size Medium • The unit comprises of steam jacket electrically heated, inner chamber and outer cover is made of stainless steel and duly insulated with high density mineral wool from the inner chamber and fitted with stable legs. • Should works on 3-phase, 440V, A/C, 50HZ supply. • Application specific integrated chip Microprocessor controller. • Provided with RS 232 output • Fitted with pressure control switch • Fitted with low water level cut off device. • The chamber is made of heavy gauge, stainless steel, fitted with stainless steel forged ring lid and two safety valve of stainless steel. • Supplied with pedal lifting device. • The unit has been fitted with pressure gauge, water outlet valve and air inlet valve, stainless steel steam condenser, tube with stainless steel eject valve. • The steam generator is made out of stainless steel heavy gauge and water draining valve. • Inner drum size : 450 x 600 mm • Accessories : Timer, 2 lid sealed gasket, Autoclave indicator strip, 2 heating coils. • Company should provide Good manufacturing product (GMP)/ WHO certificate & ISO certificate/FDA approved along with tender. • Should have ISI mark. • Should have good consumer base in Gujarat. • It is preferable, if equipment is approved by any apex Govt. institute in India. • It is preferable, if equipment have good rapport in commercial market since last 3 year. • It is preferable that 5 years AMC rate is provided & AMC rate should not more than 10 % of original the cost. • It is more preferable that company should provide CMC for the equipment • Permanent service engineer should be posted in Gujarat and attend to complaints and rectify them within 48 hours. • Comprehensive and full training of all users by suppliers for operating the equipment. • The company should supply the list of institution where the equipments are being used. • Authority letter from Manufacturer is mandatory. • For imported item, CE certificate is must. |
3 | Autoclave - vertical, fully automatic | • size small • The unit comprises of steam jacket electrically heated, inner chamber and outer cover is made of stainless steel and duly insulated with high density mineral wool from the inner chamber and fitted with stable legs. • Should works on 3-phase, 440V, A/C, 50HZ supply. • Application specific integrated chip Microprocessor controller. • Provided with RS 232 output • Fitted with pressure control switch • Fitted with low water level cut off device. • The chamber is made of heavy gauge, stainless steel, fitted with stainless steel forged ring lid and two safety valve of stainless steel. • Supplied with pedal lifting device. • The unit has been fitted with pressure gauge, water outlet valve and air inlet valve, stainless steel steam condenser, tube with stainless steel eject valve. • The steam generator is made out of stainless steel heavy gauge and water draining valve. • Inner drum size : 550 x 750 mm • Accessories : Timer, 2 lid sealed gasket, Autoclave indicator strip, 2 heating coils. • Company should provide Good manufacturing product (GMP)/ WHO certificate & ISO certificate/FDA approved along with tender. • Should have ISI mark. • Should have good consumer base in Gujarat. • It is preferable, if equipment is approved by any apex Govt. institute in India. • It is preferable, if equipment have good rapport in commercial market since last 3 year.preferable that 5 years AMC rate is provided & AMC rate should not more than 10 % of original the cost. • Permanent service engineer should be posted in Gujarat and attend to complaints and rectify them within 48 hours. • Comprehensive and full training of all users by suppliers for operating the equipment. • Authority letter from Manufacturer is mandatory. • For imported item, CE certificate is must. |
4 | Autoclave Double drum vertical (Non Microprocessor) | • The unit comprises of steam jacket electrically heated, inner chamber and outer cover is made of stainless steel and duly insulated with high density mineral wool from the inner chamber and fitted with stable legs. • Should works on 3-phase, 440V, A/C, 50HZ supply. • Fitted with pressure control switch • The chamber is made of heavy gauge, stainless steel, fitted with stainless steel forged ring lid and two safety valve of stainless steel. • Supplied with pedal lifting device. • The unit should be fitted with pressure gauge, water outlet valve and air inlet valve, stainless steel steam condenser, tube with stainless steel eject valve. • Inner drum size : 350 x 550 mm • Accessories : 2 gasket, 2 heating coils. |
5 | Autoclave Double drum vertical (Non Microprocessor) | • The unit comprises of steam jacket electrically heated, inner chamber and outer cover is made of stainless steel and duly insulated with high density mineral wool from the inner chamber and fitted with stable legs. • Should works on 3-phase, 440V, A/C, 50HZ supply. • Fitted with pressure control switch • The chamber is made of heavy gauge, stainless steel, fitted with stainless steel forged ring lid and two safety valve of stainless steel. • Supplied with pedal lifting device. • The unit should be fitted with pressure gauge, water outlet valve and air inlet valve, stainless steel steam condenser, tube with stainless steel eject valve. • Inner drum size : 450 x 600 mm • Accessories : 2 gasket, 2 heating coils. |
6 | Autoclave Double drum vertical (Non Microprocessor) | • The unit comprises of steam jacket electrically heated, inner chamber and outer cover is made of stainless steel and duly insulated with high density mineral wool from the inner chamber and fitted with stable legs. • Should works on 3-phase, 440V, A/C, 50HZ supply. • Fitted with pressure control switch • The chamber is made of heavy gauge, stainless steel, fitted with stainless steel forged ring lid and two safety valve of stainless steel. • Supplied with pedal lifting device. • The unit should be fitted with pressure gauge, water outlet valve and air inlet valve, stainless steel steam condenser, tube with stainless steel eject valve. • Inner drum size : 400 x 600 mm • Accessories : 2 gasket, 2 heating coils. |
7 | Automated nucleic acid extraction system | • Automated Bench top nucleic acid and proteins extraction and purification device using proven technology like silica based spin column or magnetic bead separation technology. • It should have touch panel and compatible with wide range of samples such as blood, plasma, body fluids, bacteria, and FFPE (Formalin Fixed Paraffin Embeded) tissue etc. • It should be automatic and the unit should be capable to process minimum 10 samples per run. • The system should be integrated with touch-screen/ computer, should allow the user to select and run protocols, install or delete protocols, save data files. • A comprehensive load check should be performed prior to sample processing to check worktable setup and to help to ensure correct loading of the instrument. • There should be optical sensor to checks the type of filter tips loaded on the worktable and that there are sufficient tips for the protocol run. • There should be availability of compatible kits for DNA extraction/RNA extraction/DNA and RNA extraction simultaneously (Nucleic acid extraction)/Protein/ miRNA from the clinical sample. • The system should be programmable to enable modifications and customization of the protocols according to the user needs and applications and should provide future upgradation in software free of charge. • Operating temperature 18–28ºC (Room temperature). • Suitable UPS with maintenance free batteries for 1 hour backup should be supplied with the system. • Warranty of the instrument: 24 months from the date of successful installation. • CMC rates for 3 years should be provided from the date of completion of warranty period. • Should provide rates for all consumables for 5 years. • CE marked/FDA approved/ISO marked. |
8 | BacT Alert Reflectance stanadards | BacT AlertT reflectance standard of Biomeriux compatible to BacT/AlerT 3D 60 & 120. It should contain Reflectance Standard A & B |
9 | Binocular Microscope | • "OPTICAL SYSTEM:- should have universal infinity connected. • High plan acromatic lenses with antifungal and antimould treatment including covers the whole path of the optical system. • The lenses should be made of high quality glass with extreme precision. • Illumination: Led illumination working at "100-240 v & 50-60 hertz & 0.45 amp, with more than 10,000 hours life and auto off facility for power saving." • "Stage focusing: stage have ceramic coated ultra-hard ceramic reckless movement and adjustable torque." • Movement: - easy and soft movement with just one finger. • Observation tube: - binocular with tilting from 30 to 60 degree inclination • Specimen holder: double slide holder with standard smooth rubber grip. • Condenser: - abbe condenser bright field with additional low magnification adaptor. • Eye-pieces:- wide field 10-20x • Objectives: should be 4x, 10x, 20x, 40x, &100 x multiple (4 or 5) nose pieces. • All objectives should be loaded with spring to avoid specimen damage • "Adjustment: adjustable with right and left hand for course and fine adjustments as well as for stage movement." • Electronically operated, inter-pupillary adjustment range: 48-75 mm • "Calibration: they should provide calibration certification from NABL recognized testing laboratory and have CMC as well as 6 monthly calibration service from NABL recognized testing laboratory." • Accessories: extra bulb, wooden storage box, wire pointer, filter holder, dark field stop, filer micrometer |
10 | Binocular Microscope | • "OPTICAL SYSTEM:- should have universal infinity connected. • High plan acromatic lenses with antifungal and antimould treatment including covers the whole path of the optical system. • The lenses should be made of high quality glass with extreme precision. • Illumination: Led illumination working at "100-240 v & 50-60 hertz & 0.45 amp, with more than 10,000 hours life and auto off facility for power saving." • "Stage focusing: stage have ceramic coated ultra-hard ceramic reckless movement and adjustable torque." • Movement: - easy and soft movement with just one finger. • Observation tube: - binocular with tilting from 30 to 60 degree inclination • Specimen holder: double slide holder with standard smooth rubber grip. • Condenser: - abbe condenser bright field with additional low magnification adaptor. • Eye-pieces:- wide field 10-20x • Objectives: should be 4x, 10x, 20x, 40x, &100 x multiple (4 or 5) nose pieces. • All objectives should be loaded with spring to avoid specimen damage • "Adjustment: adjustable with right and left hand for course and fine adjustments as well as for stage movement." • Electronically operated, inter-pupillary adjustment range: 48-75 mm • "Calibration: they should provide calibration certification from NABL recognized testing laboratory and have CMC as well as 6 monthly calibration service from NABL recognized testing laboratory." • Accessories: extra bulb, wooden storage box, wire pointer, filter holder, dark field stop, filer micrometer |
11 | Bio safety cabinet Class II | • Class II, Type-A • Working Size 2â€x2â€x2†• HEPA Filter (Supplied with Main Unit-1 Nos.) is rated for min. 99.97 % efficiency at 0.3 micron particle size. • Size of HEPA Filter 2â€x2â€x 0.5†• High efficiency (10 Microns) Pre Filter (Supplied with Main Unit-1 Nos.) • Illumination 1x20W. • Built in U.V.Germicidal Light 1x50W. • U.V. Light in work chamber inter locked with door and fluorescent light. • Stand by Mode increases filter life. • Gas Burner. 1 Nos. • Electrical Gas Cock with LED indicator (doesn’t disturb preset flow rate when shutting off gas. • Counter balanced door for effortless operation. • Door safe Position Alarm. • Electric outlet provided in the work chamber for connecting any appliances. • Whole Cabinet made of cold rolled steel sheet duly power coated inside & outside for longer life & durability. • Heavy duty exhaust system. Size-2 x 2 feet |
12 | Bio safety cabinet Class II | • Class II, Type-A • Working Size 2â€x3â€x4†• HEPA Filter (Supplied with Main Unit-1 Nos.) is rated for min. 99.97 % efficiency at 0.3 micron particle size. • High efficiency (10 Microns) Pre Filter (Supplied with Main Unit-1 Nos.) • Illumination 1x20W. • Built in U.V.Germicidal Light 1x50W. • U.V. Light in work chamber inter locked with door and fluorescent light. • Stand by Mode increases filter life. • Gas Burner. 1 Nos. • Electrical Gas Cock with LED indicator (doesn’t disturb preset flow rate when shutting off gas. • Counter balanced door for effortless operation. • Door safe Position Alarm. • Electric outlet provided in the work chamber for connecting any appliances. • Whole Cabinet made of cold rolled steel sheet duly power coated inside & outside for longer life & durability. • Heavy duty exhaust system. Size-2 x 2 feet |
13 | Bio safety cabinet Class II | • Class II, Type-A • Working Size 2â€x4â€x6†• HEPA Filter (Supplied with Main Unit-1 Nos.) is rated for min. 99.97 % efficiency at 0.3 micron particle size. • High efficiency (10 Microns) Pre Filter (Supplied with Main Unit-1 Nos.) • Illumination 1x20W. • Built in U.V.Germicidal Light 1x50W. • U.V. Light in work chamber inter locked with door and fluorescent light. • Stand by Mode increases filter life. • Gas Burner. 1 Nos. • Electrical Gas Cock with LED indicator (doesn’t disturb preset flow rate when shutting off gas. • Counter balanced door for effortless operation. • Door safe Position Alarm. • Electric outlet provided in the work chamber for connecting any appliances. • Whole Cabinet made of cold rolled steel sheet duly power coated inside & outside for longer life & durability. • Heavy duty exhaust system. Size-2 x 2 feet |
14 | Cytospin Centrifuge | • Sample Volume: 0.5 to 1 ml • Cycle Duration: 1-99 min • Adjustable Sash • Samples/Run: 24 • Number of Cytofunnels: 12 • Warnings: Lid Lock, Over speed, Imbalance, End of run • Revolution: Max speed of 100 • Sealed Head • Operating Temp: +5 C to +45 C • Clear, Spill proof LCD Display • Spill proof Keypad • Should have >20 Programmable memory • Must be US FDA approved • Sample Volume Range : • 1-well Cell Concentrator 300 to 800 µL • 3-well Cell Concentrator 50 to 200 µL • 3-well Concentrator permits application of • different samples, different concentrations or • controls on the same slide. • Reuse capability reduces operating costs. • Autoclavable version |
15 | Gel doc | • Gel doc system should have following specifications: • Maximum sample size: 28*36 cm • Maximum image area: 25*26 cm, • It should have Trans UV 302, 254, 365 nm and white, Epi-white light as an excitation source • It should have 3 Illumination Modes: Trans UV, White, Epi-White • It should have CCD detector with Resolution of 1360(H) * 1024(V), Pixel size (in Microns) 4.65 (H)* 4.65(V) • It should contain 3 filter holders: 3 positions, 2 Emission Filter and 1 Chemi. • Emission Filters: 1 included (amber), 4 optional • Dynamic Range: 3.0 Orders • Pixel Density with 4096 gray levels • It should include FireWire port to communicate with the computer. • It should include computer with compatible operating system, with application drives. • Operating Ranges: • Operating Voltage: 100/115/230 VAC • Operating Temperature: 10-280C • Operating Humidity: <70% non-condensing |
16 | Laminar air flow cabinet | • The cabinet must feature an aerosol tight, electrically driven front window made of laminated safety glass, which seals the inner chamber. Working Size 2â€x3â€x4†• It should be a negative pressure encapsulated system. • The cabinet shall incorporate HEPA filters for supply and exhaust air, providing efficiency of 99.999% for 0.3 micron particles. • System should have a safety feature, which ensures that UV light is on only when the front window is fully closed. • The safety cabinet must feature transparent laminated safety glass side window panels. • The cabinet should incorporate a non-reflecting lacquer coated rear chamber wall rather than stainless steel. • The cabinet must offer removable, autoclavable arm rests to prevent front air ducts from becoming obstructed during operation by a user’s arms. • The cabinet must not exceed 83†in height when positioned upon an accessory support stand. • The cabinet must feature both visual and audible alarm functions to indicate discrepancies in operating conditions relative to the parameters of inflow and down flow air movement and window placement. • The safety cabinet must be designed such that the supply filter is protected from potential damage via accidentally excessive mechanical force inside the work area. • The cabinet must not incorporate air ducts in the sides of the chamber interior. • The cabinet design must be such that all service, re-certification and filter changes may be conveniently accomplished from the front of the safety cabinet so that shifting of the cabinet is not required while servicing. • After sales service should be available locally. |
17 | Micro Slide Cabinet | 20000 Capacity, Made of Stainless Steel, Tray Size about 350 × 210 × 35 mm |
18 | Micro Slide Cabinet | 20000 Capacity, Made of Stainless Steel, Tray Size about 350 × 210 × 35 mm |
19 | Microscope - Binocular | • 30 / 45 degree inclined head • Electronically operated • Interpupillary adjustment range : 48 – 75 mm • Coaxial coarse / fine knobs with tension adjustment under right side. • Fine focus knob graduated, • Reverse mounted quadruple ball bearing nosepiece & rubber grip turret • ABBE condenser NA 1.25 (oil immersion) with aperture iris diaphragm & blue filter • Built in 12V, 35W illuminator with intensity control, 2000 hours led lamp • Input voltage : 100 V – 240 V • Dust cover & mirror unit - planoconcave • Objectives :Infinity corrected DIN colou d & marked Achromatic set, temper resistant objective sleeves. 4x (W.D. 26.20mm), 10x (W.D. 7.8mm), 40x (W.D. 0.31mm), 100x oil (W.D. 0.1mm) ( Fungus resistant) • Eyepiece 10X / 15X • Accessories : Extra bulb, wooden storage box, wire pointer, filter holder, dark field stop, filar micrometer |
20 | Microscope - Monocular | • 30 / 45 degree inclined head • Electronically operated • Coaxial coarse / fine knobs with tension adjustment under right side. • Fine focus knob graduated, • Reverse mounted quadruple ball bearing nosepiece & rubber grip turret • ABBE condenser NA 1.25 (oil immersion) with aperture iris diaphragm & blue filter Condenser & stop for dark ground illumination • Built in 12V, 35W illuminator with intensity control, 2000 hours led lamp • Input voltage : 100 V – 240 V • Dust cover & mirror unit - planoconcave • Objectives :Infinity corrected DIN colou d & marked Achromatic set, temper resistant objective sleeves. 4x (W.D. 26.20mm), 10x (W.D. 7.8mm), 40x (W.D. 0.31mm), 100x oil (W.D. 0.1mm) ( Fungus resistant) • Eyepiece 10X / 15X • Accessories : Extra bulb, wooden storage box, wire pointer, filter holder, dark field stop, filar micrometer |
21 | MICROSCOPE- EYEPIECE LENS | 10X WIDEFIELD WITH POINTER |
22 | Microscope- Trinocular | Optics : Color corrected infinity optics Parfocal Distance : 45 mm Tube Length : 180mm Kohler Illumination : Fixed Kohler and Full Kohler Magnification Objectives : Plan Achromat 4X, 10X, 40X and 100X Oil Immersion. All optics Should be anti fungus treated Eyepiece : 10X (FOV 20mm) with Sidentopf tube of upper and lower position and adjustable interpupillary distance and 30mm viewing angle. Trinocular phototube with 50:50 light distribution (Vis:Doc) Nosepiece : Inclined backward with 4 objective positions Illumination : 30W Halogen or LED (3W/6V) Stage : Stage for both option of right and left hand drive |
23 | Microscope-Dissecting | Student Dissecting Microscope Specifications : Eye lens: 10X Object lens: 4X Magnification times: 20X~40X Eye lens working distance: >25mm Stage dimension: 70mmX60mm |
24 | Multipurpose Refrigerated Centrifuge | Multipurpose Refrigerated Centrifuge with autoclavable, non corrosive and chemically resistant metallic rotors for 30 tubes of 1.5-2 ml size tubes •6 × 85 Rotor with adaptors for 15/50 ml tubes •4 × 250 ml Rotor with adaptors’ for 15 and 50 ml tubes •4×250 ml Rotor with adaptors for 15 and 50 ml tubes along with plates adapters for cell culture •ELISA,PCR, DNA Sequencer Extraction kit. •Features automatic rotor recognition and stores up to 35 programs •Temperature range: -9°C to 40°C •Maximum speed : 14000 rpm •Slow acceleration and deceleration for handling of sensitive samples •Fast Temp. for achieving required temperature in shortest possible time •Rotor chamber with outlet vent to remove condensed water •IVD Approved. |
25 | Pharmacy Refrigerator | • Vertical, 2-8*C, capacity 400-500l • Should have CFC free refrigerant with maximum temperature uniformity. • Should have fully extendable drawers with inner chamber of stainless steel ( at least 4-5 compartments ) • Multipane heated 3 pane glass door and frame. • Positive latch with key lock security. • System should have over 2 inches (5.1cm) CFC free foamed in place polyurethane insulation. • Simultaneous digital display of upper and lower temperatures, audio and visual alarms with controlling resolution: 0.5 °C. • User adjustable audible high and low temperature alarms. • Door open, power failure, system OK alarm. Should have digital sensor, Should have castor wheels for easy movement. • Continuous monitor of condenser efficiency with alarm. • Remote alarm connections. ( Optional ) • Built in Event log to record alarm conditions with time, date and duration. • Lockable castor wheel for easy mobility. • After sales service should be available locally. • Should have CE certificate |
26 | Refrigerated Bench top Microcentrifuge with rotors | Max Speed 18000rpm, Rotor with lid, Temp -20*C to +40*C, Accessories 1. Rotor with journal 2 places for microtitre plates 2. Rotor 8 places free swinging for 50 ml falcon tubes, 3. Rotor with 4 x 15 ml tubes |
27 | Refrigerated Bench top Microcentrifuge with rotors | • Refrigerated Bench top Microcentrifuge with rotors having maximum speed of 18000rpm, Rotor with lid. • This microcentrifuge must be supplied with these accessories 1. metallic Rotor with 2 places for microtitre plates 2. Rotor 8 places free swinging for 50 ml falcon tubes, 3. Rotor with 4 x 15 ml tubes. • Temperature Range from -10 to +40 deg.C •Fast Temp Function for quick pre- cooling of the centrifuge ( from 21 deg. C to minus 4 deg. C in only 8 minutes ) •Condensate Drain prevents the accumulation of water in the chamber of centrifuge •Dynamic compressor control system with ECO Shut off function which should optimize the cooling performance and extended compressor life •Acceleration time to max RPM 15 seconds. •Brake time form max. RPM 16 seconds. •Timer 30 Seconds to 9:59 h , with continuous mode. •Noise level 48 dB -Power Requirment – 350 W •IVD Approved. -Suitable stabilizer •Digital display of time & RPM. |
28 | Refrigerated Bench top Microcentrifuge, capacity 24-32 tubes | •Refrigerated Bench top Microcentrifuge having fixed angle rotor, capacity 24-32 tubes of 1.5 / 2ml , Max Speed 15000rpm, metallic Rotor with lid. •Temperature Range from -10 to +40 deg.C •Fast Temp Function for quick pre- cooling of the centrifuge ( from 21 deg. C to minus 4 deg. C in only 8 minutes ) •Condensate Drain prevents the accumulation of water in the chamber of centrifuge •Dynamic compressor control system with ECO Shut off function which should optimize the cooling performance and extended compressor life •Acceleration time to max RPM 15 seconds •Brake time form max. RPM 16 seconds •Timer 30 Seconds to 9:59 h , with continuous mode •Noise level 48 dB -Power Requirement – 350 W •IVD Approved. -Suitable stabilizer •Digital display of time & RPM. |
29 | Refrigerated water bath (Cryobath) | • Required a refrigerated water bath with precise chamber temperature control in the range of 3° to 56° C. • Microprocessor based PID controller. • Chamber temperature displayed to 0.1° C • Built in thermometer holder. • Adjustable over temperature alarm setting with audio and visual alarm warnings. • Should thaw random and apheresis FFP (Frozen at -40° C) and thawing should be completed within 60 to 120 min. • Chamber drain system. • Deep thawing chamber. Should have castor wheels for easy movement, • Should have Pumping mechanism by high capacity pump and maintenance of temperature by heater & compressor. Cooling Coils should be routed in a way to transfer maximum cooling. Should have Filter near water inlet inside tank to prevents clogging and movement of dust into the pump • Auto access for loading and unloading. • Thawing capacity – minimum 12 units. • Input power – 100 / 115 / 230 V, 50 / 60 Hz • Consumption – 10 Amps • Circuit Breakers – 100 V : 7A , 115 V : 7A , 230 V : 4 • Chamber volume : 18 to 20 litres or 12 bags(200ml) capacity • Environmental conditions – indoor use only Should have CE Mark |
30 | Semi Auto analyzer | • Should be compact microprocessor controlled, table top model • should be capable of performing Photometric & Turbidometric test • Wave length selections:340n,405 nm, 450 nm505nm, 578 nm,630 nm, • Programmable aspiration volume: 100 to500µl. • Analysis mode: ABS, OD,Kinetic Fixed time, End point Bichromatic. • Should have more than 60 programmable parameter of clinical chemistry • Manufacturer must bear valid FDA/CE/IO 13485 Certificate. |
31 | Semi Clinical Chemistry Analyzer | Endpoint fix time, kinetic, turbidometri 100 open programmable memory Dual cuvette mode 1000 patient data memory Power saver mode for lamp |
32 | Spectro Photo Meter | Wave length 340nm to 960nm Spectro band-10nm gratting 600 line/mm,Sample holder:single position 10mm,optional Accessories:single position 50mm rectangular holder |
33 | SPECTROPHOTOMETER | GOOD QUALITY, END POINT AND KINETIC STUDY POSSIBLE, MINIMUM 7 FILTER, OPEN SYSTEM, DIGITAL DISPLAY |
34 | SPECTROPHOTOMETER | Double beam U V Light, Wavelength 340-700nm, 6 filter position -compatible with 210 - 250 V power supply -digital display with atleast 1000 result storage capacity -aspiration and quartz square cuvette mode, 1 hour backup UPS, 6 cuvettes extra to be supplied, ISO/CE |
35 | Thermocycler | • It should be compact and should have block capacity having 96- well plate capacities for 0.2 ml/ 0.5 ml tubes; it should have 96 samples format. • It should has temperature accuracy of ±0.25°C and range from 4.0°C–99.9°C, with Peltier Heating/cooling technique, with self-detected alerts/ safety measure. It should have heated cover (programming). For heating it should increase temperature up to 5°C/sec. Temperature control should be block and calculated. • It should have internal memory with filing capabilities and preferably PCMCIA/USB slot for data storage. • It should have computer and printer interface. • It should have LCD/LED display screen. • It should have power consumption (VAC) of 100-240, 50/60 Hz. • In accessories, it should contain Temperature verification kit, method transfer card, networking software. • It should have CE MARK (MDD) • For air supply, it should meets requirements of UL 3Z77 and cUL. |
36 | Tissue floating bath | Square Shape, Tissue Floating Waterbath, ISI, DIGITAL DISPLAY WITH THERMOSTAT, Inner chamber made of HIGHLY POLISHED STAINLESS STEEL, THERMOSTAT range from 20°C to 100°C, REMI, YORKO, SEDCO |
37 | Tissue homogenizer | For disruption of cells or tissue or for resuspension of sedimented materials. With serrated pestles |
38 | UPS - Line interactive | 2.0 KV, VAH:800, AVR for single phase AC, 160 V to 280 V input, 120 min backup |
39 | UPS - Line interactive | 1.0 KV, VAH:168, AVR for single phase AC, 160 V to 280 V input, 30 min backup |
40 | UPS - Line interactive | 1.0 KV, VAH:168, AVR for single phase AC, 160 V to 280 V input, 60 min backup |
41 | UPS - Line interactive | 1.0 KV, VAH:168, AVR for single phase AC, 160 V to 280 V input, 120 min backup |
42 | UPS - Line interactive | 2.0 KV, VAH:800, AVR for single phase AC, 160 V to 280 V input, 30 min backup |
43 | UPS - Line interactive | 2.0 KV, VAH:800, AVR for single phase AC, 160 V to 280 V input, 60 min backup |
44 | UPS - OnLine | 3.0 KV, AVR for single phase AC, 160 V to 280 V input, 120 min backup, compatible for real time PCR machine |
45 | UPS - OnLine | 2.0 KV, AVR for single phase AC, 160 V to 280 V input, 120 min backup, compatible for real time PCR machine |
46 | Water purification system for clinical laboratory | • The system should be comprised of a water purification unit with pretreatment, RO, UV and UF, deionization and 0.2µ point of use filter. • Pre-treatment system should consist of filters and booster pump to purify available feed water prior to the main system. • Should have a safety mechanism after RO to divert low quality permeate to drain and thus protect downstream purification cartridges. • Should have easy plug and use design of purification cartridges • Should have automatic recirculation with built in pump when system is not in use, to prevent contamination and deterioration and to maintain optimum water purity. • Should have sanitization free ultra-filtration cartridge with minimum 2 years lifespan and supplied with validation certificate. • Should have UV lamp with minimum 2 years lifespan that will emit both 185 nm and 254 nm of wavelength. • Should have built in resistivity meter with a cell constant of 0.01 cm-1 and 0.10C accuracy thermistor to measure resistivity of RO permeate and final purified water. • Should have alphanumeric display showing product water resistivity and conductivity, product water temperature, error & maintenance messages etc. • Should have storage reservoir of minimum 6 litres with vent filter and level sensor for storing pure water • The water purification system should have full audio visual alarms. • Should supply flexible dispenser for type II water, if required. • Product Water Quality for Type I: o Flow rate: =1 L/min o Resistivity: 18.2 M?-cm o TOC (Total Organic Carbon): < 5ppb o Particles: < 1 P/ml o Bacteria level: < 0.01 CFU/ml o Endotoxins: < 0.001 EU/ml o Should be DNA, RNA, DNAse, RNAse and Pyrogen free • Suitable voltage stabilizer should be supplied with the system • Should have warranty of the instrument for 24 months from the date of successful installation and rate for CMC of the instrument for 5 years from the date of completion of warranty period. • Should provide rates for all consumables and cartridges for 3 years. • CE marked/FDA approved/ISO marked. |
47 | Weight Balance | Single pan , Electronic, NIST certified. Readability and repeatability and linearity less than 0.1mg. Weighing capacity more than 50gm |
48 | Weight Balance | Single pan , Electronic, NIST certified. Readability and repeatability and linearity less than 0.01mg. Weighing capacity more than 05mg |
49 | Cryostat | • Open – to cryostat in modular design with steering roller and locking screws. • Large stainless steel cooling chamber temp. variable down to -30 degree C. • Electronic control via touch pad keyboard for the settings of all the parameters ( section thickness and temp.) with programmable “ memory function†for fast retrieval of a prestored start position for sectioning. • Indication of present and actual temp. • Automatic 24 hour defroster with interrupt key. • Freezing bar with 25 to 27 stations down to 35 degree C. for storing specimen chucks. • Special storage compartment for marked slides 7 staining vessels on the top of cryostat. • Heated sliding window • Two removable section waste tray and brush shelf. • Fluorescent lamp illumination for cryo chamber with separate on / off switch. • Rotary microtome with backlash and maintenance free cross roller bearing in stainless steel with slot cover. • Section thickness setting from 1-25 microns. • Horizontal feed range 28 mm, vertical specimen stroke 60 mm. • Automated motorized coarse and fine feed via stepping motor. • LED display of section counter, sum of section thickness and remaining travel to front end position. • Specimen orientation on x/y axis and specimen rotation on z axis. • Maximum specimen size on microtome is upto 70*55 mm. • Hand wheel, smooth running, lockable. • Zero positioning for flattening the object parallel to knife/plate. • Limit alarm at the front space end position of the specimen cylinder. • High efficiency, new generation single compressor, less energy consumption and faster cooling. • Supplied complete with disposable blade holder, disposable blades, specimen chucks, freezing medium, cryostat oil etc. • Should have automated as well as manual cutting system. • In-built automated software programme. • Actively cooled freezing cell upto -45 degrees C. within 10 sec. • They should provide the calibration certificate from NABL recognized testing laboratory and have 3 year warranty with CMC as well as 6 monthly calibration services for NABL recognized testing laboratory. • Any upgradation of the instrument must be free of cost. • Training to laboratory personnel for operating the machine and for maintenance by the provider. • Backup machine to be provided in case of major breakdown at free of cost. • 3 year CMC with complete replacement guarantee • Maintance schedule : every 6 months |
50 | Flow Cytometer | • Power : 210-230 v50-60hz • Operating range : 15 – 40 degree c , 5-80% non-condensing relative humidity • Lasers : air-cooled, 20 mw solid state 488 nm and 17 mw hene 633 nm lasers • Laser configuration : spatically separated beams with ellipticals spots • Flow cell: 180x430 um rectangular quartz flowcell • Collection optics: optical –gel coupled 1.2na lens • Fsc resolution : 1µm • Ssc resolution : 0.5µm • Fluroescenece detector design :eflective optics with transmission filter in front Each pmt Fsc detector photodiode with 488/10bp Ssc detector pmt with 488/10bp Fluroscence detector 6 pmts in 4+2 configuration Default blue laser dyes Fitc, pe,per cp or-cy5.5,pe-cy7(525,575,678 or 695,785nm) Default red laser dyes apc,apc-cy7(660,785nm) Default detection bands blue laser:515-545;564-604;750-810nm red laser:650-670;750-810nm Fluorescence threshold fitc<100 mesf;pe<50 mesf Sensitivities Filter change procedure keyed filter, no toll required Fluidics General operation: integrated wetcart and compressor with on board housekeeping reagent Automated startup,shutdown,and cleaning cycles cytometer decontamination Automated procedure using onboard cleaning solution for all components in contact with sample Sheath consumption:1.08l/hr normal operation;<1ml/hr standby Housekeeping reagent 20 l sheath,10 l waste,2x5 l cleaning reagents capacities Carryover (average) <0.1% Max particle size 50um Flow rate/min 10mul/min Flow rate 120mul/min Nominal minimum sample volume : 30mul System cleaning daily: automated cleaning procedure, prompted on shutdown. Monthly:run long clean Sample Input Loader: Integrated 40-tube carousel loader option Throughout with loader 76tubes/hour (8 parameters, 6flourescent Compensated) Sample/test ID : Indexed carousel with ID barcode read. Work list importable from SPA DATA MANAGEMENT SYSTEM Signal Processing: Digital 18 bit data resolution for both Acquisition and analysis. Maximum Logical Gate: Limited only by system memory(2GB) Operating System:Microsoft Windows xp Pro 3 year CMC with complete replacement guarantee Maintance schedule : every 6 months Any up gradation of the instrument must be free of cost. |
51 | HPLC(High Performance Liquid Chromatography)system | • Automated, integrated, single-point controlled HPLC system, dedicated to sickle cell, thalassemia and hemoglobinopathy testing and newborn screening • The system should have continuous sample feeding, multianalyte, large 100 sample capacity, built in Q.C. management, availability of complete ready to use kits and bi-directional interface with laboratory information system. • The system should be able to screen and quantitate hemoglobins HbS, HbA2, HbA, HbF and detect the most commonly occurring abnormal hemoglobins like HbD, HbE, HbC, Hb-Q India, HbD-punjab and other rare abnormal hemoglobins. • It should have : a dedicate program for new borne sickle cell screening based on collection of blood on S & S 903 filter paper and an analysis time of not more than 3 minute per test. • An Alpha – thal program for screening of alpha thalassemia in new borns. • A built in vacuum based degassing system and automatic equilibration and wash procedures. • An audible alarms system for low buffer in mobile phase reservoirs and overflow for the waste tank, as well as built in alarms for calibration. • The system should have built in column thermostat for reproducibility • It should be able to print a hard copy report giving info on the subtype and quantity of hemoglobin detected. • Should have a dual piston pump to give a continuous and precise buffer gradient. • Should have optional bar code reader • A manual on abnormal hemoglobin variants using the releavant sickle cell anemia, beta thalassemia & new borne screening should be provided with reference to the system. • A clinical date management software programme should also be provided with the system which can give customized report from the connected computer • Should have an on board QC menu capable of storing the quality control data and printing the standard deviation and coefficient of variation values • The company should also be able to provide normal and abnormal controls and provide quality control program to help compare results with similar uses worldwide • The company should have and installation base of more than ten such systems and should able to provide the relevant product and service support in India and also have at least 5 years of presence in India supplying reagents and equipment for sickle cell anemia, thalassemia and hemoglobinopathy testing. • If hardware up gradation is not possible than should provide appropriate buy back offer with new models • Suitable software for clinical data management must be with each instrument, along with future up gradation facility • Availability of local service engineer at Gujarat • Complete ready to use Beta thalassaemia reagent kit should be provided with buffers, columns, primars, calibrations and sample vials • The system should have in kit external standards for instrument calibration and assuring accurate quantitation of results • The system should have bidirectional LIS • The system have been used for several thalassemia screening programme wor |
52 | Hematology cell counter- Seven part | Analysis principle: LASER based scatter analysis Type of cell counting: 7 part WBC differential with Retics and NBRC enumeration capability Should have multi channelanalyssi for better resolution and reproductability Analysis available WBC,Lympho#,Lympho%,Neutrophil#,Neutrophil %,Basophil#,Basophil%,Easinophil#, Easinophil%, Monocyte#,Monocyte%,RBC,HGB,MCV,PCV,MCH,MCHC,RDW-SD,RDW CV, PLT, MPV, PDW, PLT, PLCR, PLCC, HCT, PCT, RET#,RET%,NRBC#, NRBC%, IPF, PLT-0, PLT-F, IG % , IG#, RET-HE , HFR, LFR, MFR, IRF Availability of body fluid(CSF,synovial,serous) parameters like WBC-BF, RBC-BF, MN#, MN%, PMN%, PMN#, TC-BF# Discrete analysis modes available CBC,CBC+DIFF,CBC+RETIC,CBC+RETIC+DIFF,CBC+NRBC,CBC+Diff+NRBC Analysis method for WBC Tri angle Laser flow cytometry method for platelet measurement dual angle light scatter/fluroscent dye based RBC Measurement method electrical impedance Hb measurement cyanide free colorimtery Retic measurement on board light scatter(flouroscent dye/retic stain based) for reticulocyres Maximum sample Aspiration volume needed in all modes 100 µl or less Minimum sample volume required in all modes 20µl or less Throughput capacity in CBC/Differential > 100, in Retic mode 45 or more Type of modes of sample running Open and Closed vial Linearity :- Platelet: " 0 to 3000 * 10 3 cells/ micro litres" RBC : 0 to 8 x 10^6 per micro litre or more Hemoglobin : 0 to 25 gm per litre, Rectic : 0 to 24.5, WBC: " 0 to 300 * 1000 cells/ micro litres" Directly measures MCV , Analysis time in seconds 40-60, Availability of Auto dilution , should have clot detection facility and Automatic probe wipe Extended Analyses for cytopenic samples Number of reagents 5 Quality assurance system with calibration and controls Type of Calibration Both manual and automatic Direct aspiration for capillary blood from finger prick Floating discriminator for platelets and RBC counting for reliable RBC and PLT data Separate diluting nozzles for RBC and WBC Double bathing mechanism Upgradable to integrate with attachment "Fully automated slidemaker& slide stainer" Type of data management PC based, , PC hard disk >500 GB, Inbuilt monitor size in inches >5, RAM 8 GB, HDD 1 TB PC LED Monitor size 17 INCHES OR MORE, LASER printer The processor and RAM of the board system should be latest version HIS/LIS Interface RS232 No of USB Port provided 4 Display and print provided scatter plot and histograms Auto loader facility Facility for user defined flagging "Database capability of storing sets of results and graphics" >= 50000 L J Plot facility delta check for cumulative review On line QC option patient moving average QC File management "Flagging in event of unacceptable control data" Ability to transmit results to host computer Have auto cleaning function in the analysers software Type of power supply in VAC,Hz 100-240 VAC,50-60 Hz Power Backup facility 1 KVA UPS with Back up time in minutes 90 min unit to be supplied with sufficient consumables (w |
53 | IHC Stainer | • Slide Processing Option – Random, continuous and stat • Multifunctional System Performs –including IHC,ISH,SS,IF,FISH staining. • Complete Automation Including Antigen retrieval in IHC also. • Simultaneous optimization of 30-60 assay parameter. • Reagent Inventory management system • Should stain 50-70 slides per basket • One piece, bench top unit, user specified water station • Station should hold 750 ml throughs which may be filled to 350 ml 10 slides carrier • Agitation should be available • Program of station time in minutes/seconds with alarming system at every step of staining and safety facility. • Pass features to allow running of two programs while utilizing the same reagents • Turnable for rotation for convenient access to stations at the rear of the unit • Remaining and running time with station display facility. • Should give consistent results run after run • For fume containment should use the hyper clean filter • Integrated with automatic cover slip for time saving & efficiency • Compatible with most automatic cover slips • LIS and Barcode Facility • They should provide the calibration certificate from NABL recognized testing laboratory & have 3 year warranty with CMC as well as 6 monthly calibration services for NABL recognized testing laboratory. • Any up gradation of the instrument must be free of cost. |
54 | Embedding Station | • It should have compact dimensions, ease of operation, and high standards of convenience. • Paraffin reservoir is separately heated and offers a capacity of upto5 liters • Paraffin flow rate is pump controlled and adjustable in at least 5 increments • Separate paraffin collecting tray • All instrument functions - including the automatic starting time - are individually programmable • A microprocessor controlled system with automatic ON/OFF • Work area should be divided into three parts: cassette storage, working and embedding area and cold plate • Cassettes containing tissue can be stored in the separately heated, removable cassette storage tray with a capacity of approximately 100 cassettes • Cold plate holds approximately 72 base molds • Features a mold warmer compartment • Recessed work area located next to the paraffin dispenser allows for convenient and efficient tissue embedding • Excess molten paraffin can easily be drained through outlets located within the work area • Removable tray is located beneath the work area to collect the drained paraffin • Refrigeration area in front of the paraffin dispenser is conveniently located to ensure optimal cooling of paraffin embedded blocks • Paraffin reservoir: Capacity: at least 30 cassettes Separate temperature control with a range of 45-70 ºC, steps of +/-1ºC Warm-up time prior to operation: less than 5 hr • Cassette bath: Capacity: at least 100 cassettes Separate temperature control with a range of 45-70C, steps of +/- 1 ºC Warm-up time prior to operation: 1h • Mold warmer: Separate temperature control with a range of 35-70C, steps of +/- 1 ºC Warm-up time prior to operation: 1h • Work area: Separate temperature control with a range of 45-70C, steps of +/- 1 ºC Warm-up time prior to operation: 1h • Cold plate: Removable forceps holder temperature: 70 ºC Temperature range of -5 ºC Warm-up time prior to operation: less than 45 minutes Paraffin dispenser & pump temperature range of 45-70 ºC Cassette tray capacity: 6-8 cassettes Operating temperature: 18-45 ºC Power requirements are 100-240v, 50/60 Hz • 3 year CMC with complete replacement guarantee • Maintance schedule : every 6 months • Any up gradation of the instrument must be free of cost. |
55 | Microtome | • Fully automatic motorized microtome with stepper motor driven specimen feed facility ( hand-free facility) with manual option. • section thickness selection from 0.5 to 100 um. Trimming step setting from 1 – 600 µm. • Vertical specimen stroke: 70 mm and horizontal object feed 28 mm via step motor • Two manual mode of sectioning by manual rotary action and by rocking action called ergo mode to minimized the risk of developing repetitive motion disorder(RMD) • Specimen retraction: in manual operation -5-10 um in 5 um increments can be turned off., in motorized operation : varying with sectioning speed can be trued of motorized coarse feed of 300 um and 900 um • Section speed -0.5-420 mm/s=/- 10% • Knife holder base with tungsten carbide disposable blade pack of 5, quantity 3 nos. • Specimen orientation of 8 degree with antilitter feature • Motor overload protection • Historesin kit using hardener, liquid compound, Teflon mould tray, specimen block, lateral displacement with three – stop position. • They should provide the calibration certificate form NABL recognized testing laboratory • May be preferred automatic hand free computer aided section cutting. • 3 year CMC with complete replacement guarantee • Maintenance schedule : every 6 months • Any up gradation of the instrument must be free of cost. |
56 | Grossing Table With Digital Camera & Photography Attachment | • Dimension: Overall size: 55â€L*32â€W*85â€H Table size: 50â€L*32â€W*36â€H Sink size: 18â€*24â€*10â€D • The complete unit should be fabricated of S.S 304 grade • Provision of sink with two taps- one tap attached with wate spray gun with flexible pipe • Frame should be of S.S 304 square pipe 25*25mm • Integrated measuring foot rule to be provided on the front hand rest • Hood will be at the height of 3 feet from the table top • A garbage bin to be located inside the left hand cabinet of the unit • Pull-out tray for writing to be provided • A vertical support should be provided for mounting camera • Supplied complete with 1 no. tubelight 4feet & 2 focus light • All welding joints to be done by aron arc so that all the corners are well ground with no sharp edges • The table should have finally a mat finish • The leg should have nylon adjustable bullets for leveling • Stand for monitor • Also with dissecting microscope for the better observation of small biopsy • Table must have in built digital camera of minimum 5 megapixels, 512 memory card, video grabber board, video interface, foot switch, control board, barcode reader, the USB line suitable for image transfer & appropriate compatible software & computer • 3 year CMC with complete replacement guarantee • Maintenance schedule : every 6 months • Any up gradation of the instrument must be free of cost. |
57 | Automatic Tissue Processor | • Microprocessor controlled carousal type tissue processor with at least 9 freely selectable programs • User programmable parameter like infiltration time, delay time, vacuum on off, agitation n-off and single or double basked operation • Programmable infiltration time from 5 minutes to 99 hours 59 minutes in 1 minute increments • Delayed start up function to maximum of 9 days • Drain time of 60 sec in each station to reduce carry over contamination • Aluminum reagent containers of 1.8 liter with seals to minimize evaporation and exposure the hazardous fumes vacuum 500 HPA(0.5 bar) • Agitation in 3 second intervals with on/off function for through and even mixing of reagents • Maximum tissue processing capacity of 80 tissue cassettes • Maximum safety concept with automatic immersion of the basket into the beaker in case of power failure • Audible alarms error messages and warning codes for maximum safety • Chloroform resistant wax bath with temp adjustments for 45-70 degree c • Wax bathe with over temp(at 75 degree c) and under • Temp cut-off facility for the safety of tissue • Electronic locking to avoid inadvertent operation • Facility of manually lift in the crousal and remove tissue in case of long power failures • They should provide the calibration certificate from NABL recognized testing laboratory and have 3 year warranty with CMC as well 6 monthly calibration service from NABL recognized testing laboratory |
58 | Automatic Retrieval Microwave | • Should have oven capacity of about 25-30 liter • Should work at Indian voltage system • Throughput: slide capacity of about 90-120 slides per run • Should have in built temperature control • Incubation time begins at target temperature • The solutions must be aqueous & eco friendly & able to eliminate enzyme pretreatment • Superheating capability of solutions should be 100-110 C • Should able to eliminate guesswork • It should have standardized protocol • Should have uniform heating for consistent & reliable stains • Tissue morphology should not be compromised • Should be time saving as Dewax & antigen retrieval should be done simultaneously • Should be easy to use • Should have memories of last run • 3-5 different antigen retrieval solutions can be used simultaneously • 3 year CMC with complete replacement guarantee • Maintance schedule : every 6 months • Any up gradation of the instrument must be free of cost. |
59 | Pressure Cooker for HIER | • Low operational reagent use. • Low Reagent use. • Fast and Uniform epitope retrieval. • Holds 96 slides per Run. • Cost effective and efficient Heat Induced Epitope Retrieval (HIER) Solution. • Use in IHC and ISH Applications. • Multiple Temperature Settings. • Built in temperature gauge for validation. • Bundled with Bio SB ancillaries. |
60 | Aluminum rack | for 40 wasserman tube (4 x ½â€™â€™) (10 x 4) |
61 | Aluminum rack | for 30 wasserman tube (4 x ½â€™â€™) (10 x 3) |
62 | Aluminum Rack Small | For small size Test Tubes 100 x 12 mm and 75 x 12 mm 12 x 4 Rows with handle. ( 1 pc ) |
63 | Aluminum Racks Big | For Full size Test Tubes 100x16 mm in 10 x 3 Rows with handle ( 1 pc ) |
64 | Aluminum Slide drying tray with groove | Aluminum slide drying tray should be made up of thick aluminum sheet and should be used for drying freshly prepared slides in vertical or flat position. |
65 | Aluminum Slide Tray | 10"x8" for 20 (75X25 mm)slides side by side, Made: anodized aluminum |
66 | Battery for UPS | 26 AH, 12 Volts |
67 | Battery for UPS | 18 AH, 12 Volts |
68 | Block Filing Cabinet | 20000 Capacity, made of steel duly powder coated, Each drawer having 4 to 8 compartments with capacity of 125 blocks |
69 | BONE MARROW ASPIRATION NEEDLE | SALAH Disposible Sterile Needle, Length 8 cm With adjustable guard and stellate. 1 piece |
70 | BONE MARROW BIOPSY NEEDLE | JAMSHIDIS DISPOSIBLE STERILE NEEDLE, with Luer Lock adapter.Length 10cmNeedle Bore: 11G. 1 piece |
71 | Calibration weight,1 gm | 1 gm, with report to tracebility to NIST |
72 | Calibration weight,10 gm | 10 gm, with report to tracebility to NIST . |
73 | Centrifuge | Lid lock switch, Brush less motor, Angle Head Rotor with capacity to hold 24 tubes of 10ml/30X7/5ml, selection of RPM or RCF, ISO marked certificate, Time set range 0 to 99 min, option to decrease or increase time during operation |
74 | Centrifuge - 16 tubes | • Step less speed regulator. • Safety Lid interlocks to prevent cover opening during centrifugation. • Digital speed meter and 0-60 minutes digital countdown timer. • Interchangeable Head of 16 tubes. • Tube capacity: 15 ml. • Max. Capacity of 5000 rpm without rotor and heads. • Calibration Certificate. • Company should provide Good manufacturing product (GMP)/ WHO certificate & ISO certificate/FDA approved along with tender. 5 years AMC rate is provided & AMC rate should not more than 10 % of original th • Authority letter from Manufacturer is mandatory. • For imported item, CE certificate is must. Calibration certificate |
75 | Centrifuge - 8 tubes | • Step less speed regulator. • Safety Lid interlocks to prevent cover opening during centrifugation. • Digital speed meter and 0-60 minutes digital countdown timer. • Interchangeable Head of 8 tubes. • Tube capacity: 15 ml. • Centrifuge with conformity to European safety standards. • Max. Capacity of 4000 rpm without rotor and heads. • Calibration Certificate. |
76 | Centrifuge - with brushless motor | • Step less speed regulator. • Safety Lid interlocks to prevent cover opening during centrifugation. • Interchangeable Head of 24 tubesengle head rotor. • Tube capacity: 10 ml/30x7/5ml. • Max. Capacity of 5000 rpm without rotor and heads. • Calibration Certificate. • Brushless induction motor with frequency drive • Stable speed output even under unstable voltage condition • Safety lid interlock to prevent lid opening during centrifugation • Dynamic brake for quick declaration • Imbalance & Inverter fault detection with auto shutdown • Digital display of speed & time • Digital count down timer of 60 minutes • Calibration certificate |
77 | Centrifuge - with brushless motor | • Step less speed regulator. • Safety Lid interlocks to prevent cover opening during centrifugation. • Interchangeable Head of 16 tubes. • Tube capacity: 15 ml. • Max. Capacity of 5000 rpm without rotor and heads. • Calibration Certificate. • Brushless induction motor with frequency drive • Stable speed output even under unstable voltage condition • Safety lid interlock to prevent lid opening during centrifugation • Dynamic brake for quick declaration • Imbalance & Inverter fault detection with auto shutdown • Digital display of speed & time • Digital count down timer of 60 minutes • Calibration certificate |
78 | Centrifuge tubes with caps | 15 ml, Conical bottom, Sterile, with graduations, Polypropylene,Autoclavable |
79 | Cell counter | Easy to operate, Mechanically jumps by every press, quick reaction zero reset knob at side 4-digit display Counting range: 0000-9999 Counting speed: 300 number / s (based on the humans reaction speed) Size: 45 mm in diameter, 35 mm in thicknessPackage Includes 1 x Manual click counter, |
80 | Chiller insulated Ice box | 6 litres, tough rugged exterior, ultra thermo insulation, with refillable freeze bottle for extra cooling |
81 | CHIMNEY | Made : Stainless Steel, Switch : Push Buttons on the front Panel, Other Features :Light source ,Incandescent lamps, Filter, Cassette - Baffle, Suction(m²/h) : 451 - 900 |
82 | Digital hemoglobinometer ( Hemoglobin Estimation) | • Required haemoglobinometer with accuracy to be 1.5 % compared to ICSH method with an internal electronic self-test which auto calibrates the analyzer. • Should be light weight and easy to carry in mobile blood donation camp. • Stores up to 600 memories with date and time. • On screen start and toggle buttons. • Dual wavelength measurement, 570 nm for hemoglobin & 880 nm for turbidity compensation. • Maximum 20 µl or one drop of capillary, venous or arterial blood for the measurement of Hb. • An optional audio signal to alert, when results are displayed. • Results displayed within 02-10 sec depending on hemoglobin conc. o Measurement in g / dL or g/ L in the range of 0-25 gm/dl. • Microprocessor based and battery operated with minimum 24 hours battery backup with recharging facility. • After sales service should be available locally. |
83 | Drum - for autoclave | 27 x 22 cm |
84 | ELECTRIC COOKER FOR IHC | 3 LIT/5 LIT prestige pigeon, |
85 | Electronic Timer for Laboratory | Battery operated, Handy, Digital Display. Count Down with Signal and Repitition. Stopwatch & Clock-Timer Facility, Hr-Min-Sec Adjustable, Set + Reset Key |
86 | Electronic Weighing Machine | 0.0001 gm – 210 gm, accuracy 0.0001 gm -weighing should be fast, accurate & reliable -easy to operate -Compact Design -Double LCD display -Tare, Zero, Gross & Net facilities -Automatic calibration, rapid update & response time -Rugged injected molded construction - Stainless steel weighing pan, overload protection, Battery backup inbuilt, Percentage weighing, |
87 | Electronic Weight Balance | Electronic weight scale with digital display for speceimen-10gm to 5kg. Precalibrated. Standard weights should be provided for standardization |
88 | Electronic Weight Balance , 0.1gm to 100gm | Electronic weight scale with digital display for speceimen-0.1gm to 100gm Precalibrated. Standard weights should be provided for standardization |
89 | Electronic Weight Balance , 0.1gm to 2000gm | Electronic weight scale with digital display for speceimen-0.1gm to 2000gm Precalibrated. Standard weights should be provided for standardization |
90 | ESBACH’S ALBUMINOMETER | graduated glass tube used for measuring the amount of albumin in a specimen of urine with wooden cover; 1 piece |
91 | ESR Westergreen Stand | for ESR Pippette, Plastic Disposible |
92 | Forceps | Blunt & pointed - 6 inch , 2 no. / Pack |
93 | Fuch’s Rosenthal chamber | Fuch’s Rosenthal chamber for CSF, ISO/CE |
94 | Gigli Saw | 9" in length, Stainless steel, Reusable, Latex free. Premium OR grade |
95 | Heating elements | 1 KV |
96 | Heating elements | 2 KV |
97 | Heating elements | 3 KV |
98 | Horizontal Gel electrophoresis Unit | Should provide Gel casting tray 15 x 10cms, Gel casting stand, buffer chamber, safety lid with cables and UV transparent tray, 1.5 mm thick 8 and 15 mm comb |
99 | Horizontal Gel electrophoresis Unit | Should provide Gel casting tray 7 x 7 cms, Gel casting stand, buffer chamber, safety lid with cables and UV transparent tray, 1.5 mm thick 8 and 15 mm comb |
100 | Hot air Oven | • ISI Mark. • Temperature range ambient up to 250 Degree C. +/- 1 Degree C. • Digital Display cum Controller. • Mammert type • Digital imported thermostatic control & fitted with an automatic electric cut out • Accessories : Timer, 2 heating coils. • Air Circulating Fan. • Calibration Certificate. • Stainless Steel Chamber. Should be S.S.304 only. • Powder coated body. • Adjustable Selves. Chamber Size: 355†x 355†x 355â€mm |
101 | Hot Plate With Thermostat | Digital display, ISI Mark, Temperature Range: +5 to 100°C, Minimum Dimensions: 8†x 9†x 4.5†(W X L X H) |
102 | IHC Chamber (Humidity chamber) | acrelic; 16X16X6 divided into five partitions, should be fabricated of heavy duty polythene with an air tight design, Black in colour, Raising the surface of the slides approximately an inch off the floor; 1 piece |
103 | IMPROVED NEUBAUR CHAMBERS | Components: Glass counting chamber (re-usable), Material: Glass Specifications: Depth: 0.1mm. Volume: 0.9mm. Double engraved grid. Accuracy : 0.1 Degree C & 0.2Degree F. SHOULD BE PROVIDED WITH COVERSLIP, 1 glass planed cover slide (re-usable) |
104 | Incubator - (Non-Microprocessor) | • ISI Mark. • Temperature range ambient up to 80 Degree C. +/- 0.1 Degree C. • Air Circulating Fan. • Stainless Steel Chamber. • Powder coated body. • Glass Door. • Door gasket made of synthetic rubber compound. • Adjustable Selves. Chamber Size: 455†x 455†x 455â€mm |
105 | Incubator - Stainless steel(Microprocessor and digital display) | • ISI Mark. • Temperature range ambient up to 80 Degree C. +/- 0.1 Degree C. • Digital Display cum Controller. • Air Circulating Fan. • Mammert type • Calibration Certificate. • Stainless Steel Chamber. Should be S.S.304 only. • Powder coated body. • Glass Door. • Door gasket made of synthetic rubber compound. • Adjustable Selves. • Adjustable overshoot alarm & heater cut off. • In-built soft start for heaters prolongs heater life. • Feather touch button. Chamber Size: 455†x 455†x 455â€mm |
106 | Incubator - Stainless steel-(Microprocessor and digital display) | • ISI Mark. • Temperature range ambient up to 80 Degree C. +/- 0.1 Degree C. • Digital Display cum Controller. • Air Circulating Fan. • Mammert type • Calibration Certificate. • Stainless Steel Chamber. Should be S.S.304 only. • Powder coated body. • Glass Door. • Door gasket made of synthetic rubber compound. • Adjustable Selves. • Adjustable overshoot alarm & heater cut off. • In-built soft start for heaters prolongs heater life. • Feather touch button. Chamber Size: 355†x 355†x 355â€mm |
107 | Induction cook top | Appx-1200 to2000walt,Prestige,Pigeon,bajaj |
108 | Inspissator | • Durable Construction • Water temperature controlled by digital immersion • All moving parts can be easily removed for servicing • Constant level device ensures constant water level despite evaporation losses • Batches of tubes are quickly and easily set out and collected from the tray Optional Accessories: • Water Level Indicator • Digital Timer • Strirrer • Automatic Low Water Level cut Trays S.S |
109 | Laboratory Centrifuge | Laboratory Centrifuge having 4 position Fixed Angle Rotor accepting Test-Tubes / Vacutte size 85 x 12 mm and 100 x 16 mm for Serum or Plasma Separation from Blood before Biochemical Analysis. Maximum capacity of 3500-4000 rpm Brushless Motor having 3- 6 step Speed Regulator, Digital Timer 1-15 min. Low Noise, ISI Mark and Valid Individual Calibration Certificate from NABL approved Test Laboratory. |
110 | Laboratory Centrifuge | Laboratory Centrifuge having 8 position Fixed Angle Rotor accepting Test-Tubes / Vacutte size 85 x 12 mm and 100 x 16 mm for Serum or Plasma Separation from Blood before Biochemical Analysis. Maximum capacity of 3500-4000 rpm Brushless Motor having 3- 6 step Speed Regulator, Digital Timer 1-15 min. Low Noise, ISI Mark and Valid Individual Calibration Certificate from NABL approved Test Laboratory. . |
111 | Laboratory Centrifuge | Laboratory Centrifuge having 12 position Fixed Angle Rotor accepting Test-Tubes / Vacutte size 85 x 12 mm and 100 x 16 mm for Serum or Plasma Separation from Blood before Biochemical Analysis. Maximum capacity of 3500-4000 rpm Brushless Motor having 3- 6 step Speed Regulator, Digital Timer 1-15 min. Low Noise, ISI Mark and Valid Individual Calibration Certificate from NABL approved Test Laboratory. |
112 | Laboratory Centrifuge | Laboratory Centrifuge having 16 position Fixed Angle Rotor accepting Test-Tubes / Vacutte size 85 x 12 mm and 100 x 16 mm for Serum or Plasma Separation from Blood before Biochemical Analysis. Maximum capacity of 3500-4000 rpm Brushless Motor having 3- 6 step Speed Regulator, Digital Timer 1-15 min. Low Noise, ISI Mark and Valid Individual Calibration Certificate from NABL approved Test Laboratory. |
113 | Laboratory Centrifuge | Laboratory Centrifuge having 24 position Fixed Angle Rotor accepting Test-Tubes / Vacutte size 85 x 12 mm and 100 x 16 mm for Serum or Plasma Separation from Blood before Biochemical Analysis. Maximum capacity of 3500-4000 rpm Brushless Motor having 3- 6 step Speed Regulator, Digital Timer 1-15 min. Low Noise, ISI Mark and Valid Individual Calibration Certificate from NABL approved Test Laboratory. |
114 | L-Shape Mold | Material: Brass, SIZE: 30mm x 18mm x 2.5 mm |
115 | Magnetic Retreiver | It should be made up of PTFE/ ALNICO V MAGNET material, size: 30 cm length |
116 | Magnetic Stirrer / Cyclomixer | Mini Device, Noiseless operation, Low rotation, Variable Low Speed, 220 V AC |
117 | Manual DC Blood Cell Counter | 5 Key-01 No. |
118 | Manual DC Blood Cell Counter | 8 Key-01 No. |
119 | Metal loop holder | Heat resistant handle compatible to any size of loop or wire, 8 no. / pack |
120 | Micro spin Magnetic string bar | It should be made up of PTFE/ ALNICO V MAGNET material, 1 set of different available sizes. |
121 | Microcentrifuge | 8 place rotor for 1.5 ml tubes and 4 place rotor for 8X0.2 ml tube strips and 8 adaptors for 0.5 ml and 0.4 ml tubes. |
122 | Microcentrifuge | For centrifugation of 6x1.5 ml tubes,should provide spare rotor for 12 x 0.5 ml tube |
123 | Microcentrifuge | For centrifugation of 6 x 1.5 ml tubes,should provide spare 2 place rotor for 8 x 0.2 ml tube strips, Fixed speed of 6000rpm |
124 | Microcentrifuge | (For Spin Column) Microcentrifuge with RPM – 100 to 15000 or RCF 21130 -Temperature Range from -10 to +40 deg.C -Fast Temp Function for quick pre- cooling of the centrifuge ( from 21 deg. C to 4 deg. C in only 8 minutes ) -Metallic Rotor with 18Xspin columns or 1.5/ 2 ml tubes with open tube lid -Condensate Drain prevents the accumulation of water in the chamber of centrifuge -Dynamic compressor control system with ECO Shut off function which should optimize the cooling performance and extended compressor life -Acceleration time to max RPM 15 seconds -Brake time form max. RPM 16 seconds -Timer 30 Seconds to 9:59 h , with continuous mode -Noise level 48 dB -Power Requirment – 350 W -IVD Approved. -Suitable stabalizer |
125 | Micropipette - Electronic | Digital Display with graphical interface Multiple Pipetting options Autoclavable tip con Different Pipetting Speed Tip should be able to be fit with locking mechanism with tip cone to ensure better ?precision and reduce operator-based variations. Aspiration and dispensing button should be able to be operated with forefinger of the ?pipetting hand. Automated tip ejection to reduce repetitive stress Ability to store atleast 9 different programs Lithium-ion battery should be used Mixing, dilution, mixing & dilution modes. Adjustable finger rest would be preferred for better ergonomics Colour coded buttons |
126 | Micropipette - fixed volume | Autocalvable, with tip ejector - 5 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
127 | Micropipette - fixed volume | Autocalvable, with tip ejector - 50 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
128 | Micropipette - fixed volume | Autocalvable, with tip ejector - 25microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
129 | Micropipette - fixed volume | Autocalvable, with tip ejector - 20 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
130 | Micropipette - fixed volume | Autocalvable, with tip ejector - 100 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
131 | Micropipette - fixed volume | Autocalvable, with tip ejector - 200 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
132 | Micropipette - fixed volume | Autocalvable, with tip ejector - 500 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
133 | Micropipette - fixed volume | Autocalvable, with tip ejector - 1000 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
134 | Micropipette - single channel, variable volume, 0.1-2.5microlitre | 0.1 - 2.5 microlitre • single channel, with tip ejector •Type of tip cone:Microtip • Fully autoclavable and UV resistant without need to dismantle the pipette before autoclaving. • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance . Thermo Scientific / Eppendorf/ Nichiryo |
135 | Micropipette - variable volume, multichannel | 50 - 300 microlitre • 8 channel • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
136 | Micropipette - variable volume, multichannel | 01 - 10 microlitre • 8 channel • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
137 | Micropipette - variable volume, multichannel 10 - 100 microlitre | 30 - 300 microlitre • 8 channel • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
138 | Micropipette - variable volume, multichannel 20 - 200 microlitre | 20 - 200 microlitre • 8 channel, , with tip ejector • Fully autoclavable without need to dismantle the pipette before autoclaving. • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance . •Thermo Scientific / Eppendorf/ Nichiryo |
139 | Micropipette - variable volume, multichannel 5 - 50 microlitre | 5 - 50 microlitre • 8 channel , with tip ejector • Fully autoclavable without need to dismantle the pipette before autoclaving. • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance . •Thermo Scientific / Eppendorf/ Nichiryo |
140 | Micropipette - variable volume, multichannel 5 - 50 microlitre | 5 - 50 microlitre • 8 channel , with tip ejector • Fully autoclavable without need to dismantle the pipette before autoclaving. • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance . •Thermo Scientific / Eppendorf/ Nichiryo |
141 | Micropipette - variable volume, single channel | 2 - 10 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
142 | Micropipette - variable volume, single channel | 5 - 50 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
143 | Micropipette - variable volume, single channel | 20 - 200 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
144 | Micropipette - variable volume, single channel | 10 - 100 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
145 | Micropipette - variable volume, single channel | 200 - 1000 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
146 | Micropipette - variable volume, single channel | 2 - 20 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • Color d volume range for easy identification • Automatic locking of set volume • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
147 | Micropipette - variable volume, single channel | 0.5-50 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button. • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • Color d volume range for easy identification • Automatic locking of set volume • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance. •Thermo Scientific / Eppendorf/ Nichiryo |
148 | Micropipette - variable volume, single channel | 50 - 300 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • Color d volume range for easy identification • Automatic locking of set volume • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance. •Thermo Scientific / Eppendorf/ Nichiryo |
149 | Micropipette - variable volume, single channel | 0.2-2 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
150 | Micropipette - variable volume, single channel | 0.5-5 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
151 | Micropipette - variable volume, single channel | 100-1000 microlitre • Fully autoclavable without need to dismantle the pipette before autoclaving. • Provision to avoid accidental volume change with rotating pipette hat on the pipetting button • Light weight & ergonomics design for user comfort • No sharp edges to tear gloves • Soft touch tip ejection • One handed operation for safe handling of potentially infectious materials • Super blow out for microorganisms volume pipetting. • Easy in laboratory recalibration & maintenance •Thermo Scientific / Eppendorf/ Nichiryo |
152 | MICROSCOPE- EYEPIECE LENS | 20X WIDEFIELD WITH POINTER |
153 | MICROSCOPe- OBJECTIVE LENS | 2X ACHROMAT, SPRING LOADED, WIDE FIELD, LABOMED, LABOVISION, LABOSCOPE, OLYMPUS, VISION2000, MEDLINE,BIOPLAN |
154 | MICROSCOPe- OBJECTIVE LENS | 5X ACHROMAT, SPRING LOADED, WIDE FIELD, , LABOMED, LABOVISION, LABOSCOPE, OLYMPUS, VISION2000, MEDLINE,BIOPLAN |
155 | MICROSCOPe- OBJECTIVE LENS | 10X ACHROMAT, SPRING LOADED, WIDE FIELD, , LABOMED, LABOVISION, LABOSCOPE, OLYMPUS, VISION2000, MEDLINE,BIOPLAN |
156 | MICROSCOPe- OBJECTIVE LENS | 20X ACHROMAT, SPRING LOADED, WIDE FIELD, , LABOMED, LABOVISION, LABOSCOPE, OLYMPUS, VISION2000, MEDLINE,BIOPLAN |
157 | MICROSCOPe- OBJECTIVE LENS | 40X ACHROMAT, SPRING LOADED, WIDE FIELD, , LABOMED, LABOVISION, LABOSCOPE, OLYMPUS, VISION2000, MEDLINE,BIOPLAN |
158 | MICROSCOPe- OBJECTIVE LENS | 100X ACHROMAT, SPRING LOADED, WIDE FIELD, , LABOMED, LABOVISION, LABOSCOPE, OLYMPUS, VISION2000, MEDLINE,BIOPLAN |
159 | Microtip holder rack | Autoclavable - 96 holes, plastic |
160 | Milk cooler | • Heavy duty compressor • Painted GI inside • Imported themostat with PUF insulation • Ecofriendly refrigerant • Low power consumption • 2-12º C • 180-260 Walts • 160 x 65 x90 (L x W x H in cm) • Inside capacity 450 liters |
161 | Mini centrifuge for PCR tube strips | Mini centrifuge for PCR tube strips should have RPM speed up to 8000, should accommodate 2 strips (1* 8 wells of 0.2ml optical tubes) of PCR , Quiet and reliable, small foot print , Independent ON/OFF switch., With Lid, It should be electrically operated |
162 | Mini cooler minus 20 degree centigrade | Mini cooler -20 degree centigrade should be with gel filled cover for maintaining -20*C temperature for up to two hours and having capacity of 32 Eppendorf tubes of 1.5 ml capacity each. It should be made up of PC / Non toxic gel, with lid. |
163 | Mini cooler minus 20 degree centigrade | Mini cooler -20 degree centigrade should be with gel filled cover for maintaining -20*C temperature for up to two hours and having capacity of 12 Eppendorf tubes of 1.5 ml capacity each. It should be made up of PC / Non toxic gel, with lid. |
164 | Mini cooler minus 20 degree centigrade | Mini cooler minus 20 degree centigrade should be without gel filled cover for maintaining -20*C temperature for up to two hours and the aluminum block having capacity of 96 wells for PCR tubes , strips or plate having capacity of 0.2 ml each well, made of PC/Non toxic gel material, with lid. |
165 | Mini cooler zero degree centigrade | Mini cooler zero degree centigrade should be with gel filled cover for maintaining 0*C temperature for up to two hours and having capacity of 32 wells for 1.5 ml Eppendorf, made of PC/Non toxic gel material, with lid. |
166 | Mircopipette-variable volume, single channel | 50-1000 microliter. Light weight & ergonomic design for user comfort, no sharp edges to tear gloves, soft touch tips |
167 | Mircopipette-variable volume, single channel | 500-5000 microliter. Light weight & ergonomic design for user comfort, no sharp edges to tear gloves, soft touch tips |
168 | Motor less Magnetic Stirrer | It should be made up of ABS material, with = 12 (L)*12(B) cm in size, with electromagnetic drive, with smooth speed controller with range of 100-1000 RPM, should stir up to 3 Liters, Top should be made up of Alkali and Acid resistant material, with independent ON and OFF power switch.. |
169 | Photoelectric Colorimeter. | Digital LED Display of Abs / OD / Transmittance, 8 Optical Filters in 400-700 nm wavelength Photometric range 0 - 3 A Standard Optical Glass Cuvette and Micro-Cuvette holder device to also read 0.5 ml reaction mixture. Extra 6 Std. Cuvettes and 1 Microcuvette Holder with 6 Microcuvettes. 220V AC |
170 | Pipette Stand | It should provide easy access and storage for 04 pipettes of varying sizes. Made of light, easy-to-clean plastic, |
171 | Portable pH meter – pen type | Portable digital pH meter that should measure range of pH from 0 to 14 pH with accuracy + 0.01, Pen type |
172 | Pressure cooker for I.H.C | PRESTIGE,PIGEON, |
173 | Refrigerator - Double door, frost free | 4 - 8 degrees,400 - 450 litre |
174 | Refrigerator - single door, frost free | 4 - 8 degrees,250 - 350 litre |
175 | Refrigerator -Convertible | • Vertical, 2-8°C, capacity not less than 400 litres • Should have CFC free refrigerant with maximum temperature uniformity. • Should have fully extendable drawers • Should have convertible freezer • Positive latch with key lock security. • Should have digital display of temperature. • Should have warranty of the instrument for 24 months from the date of successful installation. • Should have CE marked/ISO marked |
176 | Repeating Pipette System | Dispense from 10 microliter to 5000 microliter 5 microliter volume setting Chart on Handle, Rotating wheel to set number of dispense steps, curved finger rest for better ergonomy. |
177 | Rotor for Refrigerated Centrifuge | Fixed angle, 30 place for 1.5/2.0 ml tubes, maximum speed 14000 rpm with aerosol tight lid, compatible with Eppendorf Refrigerated Centrifuge |
178 | Rotor lid for Refrigerated Centrifuge | Aerosol tight lid for fixed angle rotor of 30 place for 1.5/2.0 ml tubes, compatible with Eppendorf Refrigerated Centrifuge |
179 | Round Magnetic string bar with pivot ring | It should be made up of PTFE/ ALNICO V MAGNET material, size 12.7 x 76 mm. |
180 | SAHLI’S HAEMOGLOBINOMETER |  20 ml hemoglobin with latex tube with WBC pipette & RBC pipette with 2 square tube extra |
181 | SAHLI’S HAEMOGLOBINOMETER | Standard Sahlis Haemoglobinometer, ISO/CE |
182 | SCALPEL BLADE | NO.23 STAINLESS STEEL; 100 pieces |
183 | SCALPEL BLADE | NO.24 STAINLESS STEEL; 100 pieces |
184 | Scalpel Blade | No. 36 Stainless Steel; 100 pieces |
185 | SCALPEL Handle | NO. 3 STAINLESS STEEL, GOOD HAND GRIP; 1 piece |
186 | SCALPEL Handle | NO. 4 STAINLESS STEEL, GOOD HAND GRIP; 1 piece |
187 | Scalpel Handle | 4 Graduated, Long, Stainless Steel, Good hand grip; 1 piece |
188 | Scissor Straight | 3" Blade size, Stainless Steel; 1 piece |
189 | Scissor Straight | 5" Blade size, Stainless Steel; 1 piece |
190 | Scissor Straight | 7" Blade size, Stainless Steel; 1 piece |
191 | Slide Rack | For Staining, 20 Slide arrranged parallel Capacity with bucket handle. Made: Stainless Steel |
192 | Slide staining assembly | Having capacity of 20 slides and made of stainless steel |
193 | Staining bottle rack - plastic | Staining bottle rack made up of durable plastic having height of 3 inch with hole diameter of 2 inch and the rack should have a capacity of 8 bottle |
194 | Staining bottle rack - Wooden | Wooden staining bottle rack having height of 3 inch with hole diameter of 2 inch and the rack should have a capacity of 8 bottle |
195 | Staining stand for slide staining | Staining stand for slide staining made up of aluminum. It should be 2 inches broad and 18 inches long parallel |
196 | Stainless Steel Tray , Size 12 x 12 x 2 inches | Size 12 x 12 x 2 inches Heavy Gauge 20 sheet ( 1 pc ) |
197 | Stainless Steel Tray , Size 18 x 12 x 2 inches | Size 18 x 12 x 2 inches Heavy Gauge 20 sheet ( 1 pc ) |
198 | Steel Trolley | 1.5 feet X 3 feet, Height 3 feet, with wheel |
199 | Table top pH meter - digital with combined electrode | Digital pH meter having combined electrode that should measure range of pH from 0 to 14 pH with of accuracy of + 0.01, electrically operated, tabletop. |
200 | Tachometer | Digital non-contact type tachometer should display 5 digits, sampling time 1-5 Seconds, autoranging,5-999.9 to 1000-99999, accuracy - 0.5 =/- digit, Memory - last value , minimum & maximum value, detecting distance 50 to 500mm, with all accessories-Carrying case, Instruction Manual, surface speed Test Wheel, RPM adapter (cone),RPM adapter (funnel) |
201 | Tachometer- Digital- Non Contact type- Calibrated | Digital non-contact type tachometer should display 5 digits, Sampling time 1-5 Seconds, autoranging,5-999.9 to 1000-99999, accuracy - 0.5 =/- digit, Memory - last value , minimum & maximum value,detecting distance 50 to 500mm, with all accessories-Carrying case, Instruction Manual, surface speed Test Wheel, RPM adapter (cone),RPM adapter (funnel)-Tachometer must be calibrated,from NABL accredited lab or National Physical Lab |
202 | Test tube rack | Plastic Test tube rack made up of durable plastic having 5 x 10 hole for supports of 1 inch diameter test tubes |
203 | Test tube rack | Plastic Test tube rack made up of durable plastic having 5 x 10 hole for supports of 3/4 inch diameter test tubes |
204 | Test tube rack | Plastic Test tube rack made up of durable plastic having 5 x 10 hole for supports of 5/8 inch diameter test tubes |
205 | Test tube rack | Wooden Test tube rack having 5 x 10 hole for supports of 5/8 inch diameter test tubes |
206 | Test tube rack | Wooden Test tube rack having 5 x 10 hole for supports of 1 inch diameter test tubes |
207 | Test tube rack | Wooden Test tube rack having 5 x 10 hole for supports of 3/4 inch diameter test tubes |
208 | Thermo meter | Thermo meter - Minus 20 degree to 10 degree , digital |
209 | Thermo meter | Thermo meter - Alcohol liquid in glass Minus 20 degree to 10 degree |
210 | Thermo meter | Thermo meter - Minus 100 degree to 50 degree , Digital |
211 | Thermo meter | Thermo meter - Minus 50 degree to 50 degree , Digital, calibrated, by NABL accredited lab or National Physical Lab |
212 | Thermo meter | Thermo meter - Minus 20 degree to 10 degree , Digital, calibrated,by NABL accredited lab or National Physical Lab |
213 | Thermo meter | Thermo meter - Mercury liquid in glass 0 degree to 250 degree |
214 | Thermo meter | Thermo meter - Mercury, liquid in glass 0 degree to 100 degree , Calibrated, traceability NABL accredited lab or National Physical Lab |
215 | Thermo-hygrometer | Dual analog output of temperature and humidity for system expansion, Unique LCD dual display which continuously indicates temperature and humidity simultaneously, Compact interchangeable combined temperature/humidity probe, High accuracy, Temperature: +/-0.2ºC Humidity: +/-2.5%RH,One touch "Data-Hold" function, Water resistant design, easy operation, Storage Ambient Range. (Meter) -20 to 60ºC (-5 to 150ºF) Below 85% RH, Resolution Humidity: 0.1% RH. Temperature: 0.1ºC, 0.1ºF |
216 | Thermohygrometer- Calibrated | Dual analog output of temperature and humidity for system expansion, Unique LCD dual display which continuously indicates temperature and humidity simultaneously, Compact interchangeable combined temperature/humidity probe, High accuracy, Temperature: +/-0.2ºC Humidity: +/-2.5%RH,One touch "Data-Hold" function, Water resistant design, easy operation, Storage Ambient Range. (Meter) -20 to 60ºC (-5 to 150ºF) Below 85% RH, Resolution Humidity: 0.1% RH. Temperature: 0.1ºC, 0.1ºF. Calibrated by NABL accredited lab or National Physical Lab |
217 | Thin Stainless steel Probes | Malleable & Non Malleable |
218 | Timer | digital display |
219 | TISSUE CASSETTE - ROUND | Made of Stainless Steel, Round shape, Standard diameter for tissue Processor; 1 piece |
220 | TISSUE CASSETTE - SQUARE | Made of Stainless Steel, Square shape, Standard diameter for tissue Processor; 1 piece |
221 | Tooth Forceps | 6" Size-S.S.; 1 piece |
222 | Tooth Forceps | 8" Size-S.S.; 1 piece |
223 | Transport box (Capacity: 20-25 lit) | • Should be used for transport of blood bags and blood sample with cold chain maintenance. • Capacity: 20 – 25 liters. • Internal temperature adjustable with digital controller in range of: +25° C to -25° C with increment in step of 10° C. • CFC free cooling system. • Digital Display of temperature. • Should be sturdy and easy cleaning and disinfection of container. • An integrated AC>DC rectifier with AC automatic priority circuit with battery backup. • Power source: 220-240vAz, 50Hz. • Low current consumption, vibration resistance and able to work at an angle up to 300 at environment temperature of 30°C to 45° C. • After sale service should be available locally |
224 | Transport box (Capacity: 50-60 lit) | • Should be used for transport of blood bags and blood sample with cold chain maintenance. • Capacity: 50 – 60 liters. • Internal temperature adjustable with digital controller in range of: +25° C to -25° C with increment in step of 10° C. • CFC free cooling system. • Digital Display of temperature. • Should be sturdy and easy cleaning and disinfection of container. • An integrated AC>DC rectifier with AC automatic priority circuit with battery backup. • Power source: 220-240vAz, 50Hz. • Low current consumption, vibration resistance and able to work at an angle up to 300 at environment temperature of 30°C to 45° C. • After sale service should be available locally |
225 | Transport box (Capacity: 70-80 lit) | • Should be used for transport of blood bags and blood sample with cold chain maintenance. • Capacity: 70 – 80 liters. • Internal temperature adjustable with digital controller in range of: +25° C to -25° C with increment in step of 10° C. • CFC free cooling system. • Digital Display of temperature. • Should be sturdy and easy cleaning and disinfection of container. • An integrated AC>DC rectifier with AC automatic priority circuit with battery backup. • Power source: 220-240vAz, 50Hz. • Low current consumption, vibration resistance and able to work at an angle up to 300 at environment temperature of 30°C to 45° C. • After sale service should be available locally |
226 | Transport Box for Blood Sample Test-Tubes | About 18 L x 12 W x 12 H size, double walled plastic with insulation and carrying handle ( 1 pc ) |
227 | Transport Box/ Cool Box | Transport box having dimensions of 10x7x7 inches, with 2 gel packs |
228 | Urinometer | Glass Urinometer |
229 | Volume Dispenser | 0.0 to 2.0 ml, with minimum Dispensing capacity of 0.1ml |
230 | Vortex Mixer | Maximum speed 3000rpm, should include one hand insert, microtube insert and cup attachment |
231 | Water bath | 16 Guage Stainless Steel, Single Walled, Heavy Round base 10" Diameter with Heavy Guage Stand. Electrically Operated, 220V AC by 6-8 " long Heater Coils 1500 W. Inner SS Rack to hold about 30 Test Tubes of 100x16mm size. Spare 2 Inner SS Racks for Tubes and 1 stand with each Water bath. |
232 | Water bath | • Water bath with ISI Mark. • Temperature ambient up to 90 Degree C. +/- 0.5 C. • Digital Display cum Controller. • Stainless Steel Chamber. Should be S.S.304 only • Stirrer with S.S. Shaft & blade with speed Controller. • Calibration Certificate. • Capacity: 2. Racks. Inner Chamber:300x250x150mm |
233 | Water bath | • Water bath with ISI Mark. • Temperature ambient up to 90 Degree C. +/- 0.5 C. • Digital Display cum Controller. • Stainless Steel Chamber. Should be S.S.304 only • Stirrer with S.S. Shaft & blade with speed Controller. • Calibration Certificate. • Capacity: 4. Racks. Inner Chamber:330x300x150mm. |
234 | Water Bath | • Water bath with ISI Mark. • Temperature ambient up to 90 Degree C. +/- 0.5 C. • Digital Display cum Controller. • Stainless Steel Chamber. Should be S.S.304 only • Stirrer with S.S. Shaft & blade with speed Controller. • Calibration Certificate. • Capacity: 6 Racks. Inner Chamber:455x300x150mm |
235 | Water Bath | Square shape tissue floating• Water bath with ISI Mark. • Digital Display with thermostat. • Inner Chamber made of highly polished stianless steel. Thermostat range from 20 degree C. to 100degree C. Remi/Yorco/Sedco |
236 | Water Quality Testing Meter | TDS / Conductivity Testing, Hand Held Meter, Eutech Calibration Certification. |
237 | ACRYLIC JAR | FOR MOUNTING MUSEUM SPECIMENS with mounting road STAND and with lid, Square shape, Capacity- 1 Litre |
238 | ACRYLIC JAR | FOR MOUNTING MUSEUM SPECIMENS with mounting road Stand and with lid, Square shape, Capacity- 2.5 Litre |
239 | ACRYLIC JAR | FOR MOUNTING MUSEUM SPECIMENS with mounting road and with lid, Square shape, Capacity- 500ml |
240 | Beaker Glass - autoclavable | 500 ml ,BOROSILICATE GLASS |
241 | Beaker Glass - autoclavable | 100 ml,BOROSILICATE GLASS |
242 | Beaker Glass - autoclavable | 50 ml,BOROSILICATE GLASS |
243 | Beaker Glass - autoclavable | 1000 ml,BOROSILICATE GLASS |
244 | Beaker Glass - autoclavable | 2000 ml,BOROSILICATE GLASS |
245 | Bio tips (Microtips) | 2-200 microliter ,Neutral color,universal fit,Bevel point |
246 | Bio tips (Microtips) | 1000 microliter ,Neutral color,universal fit,Bevel point |
247 | Bio tips (Microtips) | 2-200 microliter ,yellow color,universal fit,Bevel point |
248 | Bio tips (Microtips) | 1000 microliter, Yellow color universal fit,Bevel point |
249 | Bio tips (Microtips) | 2000 microliter,universal fit,Bevel point |
250 | Bio tips (Microtips) | 5000 microliter,universal fit,Bevel point |
251 | Biotips (Disposable) for micropipette | 1000ul pack = 500 ISO Thin-walled (25% less plastic) for reduced waste ; Care/Tarson/Polylab. 500 Per pack |
252 | Biotips (Disposable) for micropipette | 500 ul 1 pack = 500 ISO Thin-walled (25% less plastic) for reduced waste; Care/Tarson/Polylab. 500 Per pack |
253 | Biotips (Disposable) for micropipette | 200 ul 1 pack = 500 ISO Thin-walled (25% less plastic) for reduced waste; Care/Tarson/Polylab. 500 Per pack |
254 | Blood Group tile | 12 well tile for blood grouping |
255 | Blotting paper sheet | 56 x 43 cm ( L x W) |
256 | Brush for test tube cleaning different sizes | Good quality. 1 piece |
257 | Circled Slides For Cytospin centrifuge | (Coated & Non coated) |
258 | Coplin Jar & Lid | Plastic,Horizontal made of polypropylene can hold 10 slides of the size1"x3" back to back |
259 | Coverglass (Microscopic ) | 22x22mm,bluestar/blueribbon/goldstar |
260 | Coverglass (Microscopic ) | 22x50mm,bluestar/blueribbon/goldstar |
261 | Cup for ACL TOP CTS 300 | should competible with fully automatic coagulometer of instrument & laboratory model ACL TOP CTS 300 capacity 2ml |
262 | Cuvette for ACL TOP CTS 300 | Cuvette for Fully automatic coagulometer IL ACL TOP CTS . |
263 | Diamond Pencil | good quality |
264 | DISPOSABLE URINE CONTAINER* | CLEAN GOOD QUALITY PLASTIC with screw cap lid; 50 ML CAPACITY; 1000 Piece |
265 | Dropper | Plastic, disposable.; 10 pieces |
266 | Eppendrof cups | Plastic with cap 1.5 ml, conical; 1000 piece |
267 | Eppendrof cups | Plastic with cap 1 ml, conical; 1000 piece |
268 | ESR pipette (westergren) * | Disposable ISO Made of Polystyrene Colour Transparent Size 12 x 75 mm Internal Diameter 2.5mm graduated scale from 0 to 180mm; 1 piece |
269 | ESR Vacuette | ISO Black cap, 2 ml, Tube Size (mm): 13 mm x 75 mm 16 mm x 100 mm Additive: 3.2% or 3.8% buffered tri sodium citrate (0.109M); 100 piece |
270 | Filter cards | White Filter Cards thick type for use with 0.5 ml samples.used in Thermo Scientific Model Cytospin 4,(200/pack) |
271 | Filter paper | Whatman Paper No. 1; 100 Piece |
272 | FUNNEL PLASTIC | 3’’ DIAMETER ; 1 piece |
273 | Glass Beaker | Measuring capicity 50 ml, standard graduation marking, Borosilicate glass; 1 piece |
274 | Glass Beaker | Measuring capicity 100 ml, standard graduation marking, Borosilicate glass;1 piece |
275 | Glass Beaker | Measuring capicity 250 ml, standard graduation marking, Borosilicate glass; 1 piece |
276 | Glass Beaker | Measuring capicity 500 ml, standard graduation marking, Borosilicate glass; 1 piece |
277 | Glass Beaker | Measuring capicity 1000 ml, standard graduation marking, Borosilicate glass; 1 piece |
278 | GLASS CAPILLARIES | FOR CLOTTING TIME; Blue Star/Blue Ribbon / gold star; Pack of 100 piece |
279 | GLASS JAR | for mounting museum specimen with lid & with glass road stand square shape, glass road strenth- 8 mm ,6mm. capacity 500 ml,1liter,2.5 liter ,3 liter, 5liter ,8 liter |
280 | GLASS RODS | Size: 4-5 ft, diameter 5 mm, For museum specimen mounting ISO Good quality; 1 piece |
281 | GLASS RODS stand (ready to use ) | 30x21x16 ,34X24X11, 27X24X18, 29X25X8,24X21X9,20X15X9,20X19X4,22X9X7,17X7X7,28X21X10,42X10X7,35X14X9, 30X13X9,25X14X7,20X12X13,14X19X5,19X12X7,20X7X4,20X17X6,17X15X5,14X14X7,21X7X4,14X7X4,15X9X7 ,28X28X9,26X11X15,28X15X7,26X18X6,14X10X4,29X14X11,13X8X4 diameter 6 mm & 8 mm, For museum specimen mounting with different size & ISO Good quality; |
282 | Glass Slide (FROSTED) | One side frosted, Size 75*25 mm, 1.2mm thickness ; 50 slides per packet 72 packet per box ;50 slides; Blue Star/Blue Ribbon / gold star; 50 slides/box |
283 | Halogen Lamp for microscope | Halogen Lamp for microscope of 6 V, 15 W; 1 piece |
284 | Hb pipette | German made, ISO, good quality glass; 1 piece |
285 | Hb square tubes | ISO, good quality glass for Shahlis apparatus; 1 piece |
286 | Kahn tube | Size: 3"*1/2, ; 1 No. |
287 | Measuring Cylinder | 25ml Borosilicate glass; 1 piece |
288 | Measuring Cylinder | 50ml Borosilicate glass; 1 piece |
289 | Measuring Cylinder | 100ml Borosilicate glass; 1 piece |
290 | Measuring Cylinder | 250ml Borosilicate glass; 1 piece |
291 | Measuring Cylinder | 500ml Borosilicate glass; 1 piece |
292 | Measuring Cylinder | 1000mlBorosilicate glass; 1 piece |
293 | Micro- aid glass slide simple | Size: 75mm long x 25mm wide x 1.2 mm thickness, ISO/CE, ;50 slides; Blue ribbon,blue star,gold star; |
294 | micropipette holding stand | having capacity of holding 3 micropipettes |
295 | Micropipette Tips | For 20 - 50 microlitre capacity Transparent Pack of 100 tips |
296 | Micropipette Tips | For 50 -100 microlitre capacity Transparent Pack of 100 tips |
297 | Micropipette Tips | For 500 - 1000 microlitre capacity Transparent Pack of 100 tips |
298 | Micropipette Tips | For 100 - 500 microlitre capacity Transparent Pack of 100 tips |
299 | Micropipette Tips | For 5 - 10 microlitre capacity Transparent Pack of 100 tips |
300 | Microtome Disposible Blade | Low Profile, For Micron Microtome; 10 pieces |
301 | Pasture Pipettes with Rubber tips | ISO Borosilicate glass or Good quality; 10 pieces |
302 | PEP PEN | Good Quality; 1 piece |
303 | PH STRIP | pH range 3.0-10 Graduation 0.5 pH, ISO CE; SIGMA/ GLAXO/SIEMENS/BAYER; 10 Strips; 10 strips |
304 | pH Test strips | pH range 6.0-7.7 Graduation 0.2-0.4 ph, ISO, ;As per manufacturers kit insert; SIGMA/GLAXO/SIEMENS/BEYER; 10 strips |
305 | Pipette | Glass pipette, 5 ml and 10 ml with markings.; 1 piece |
306 | Pipette Stand | It should provide easy access and storage for 04 pipettes of varying sizes. Made of light, easy-to-clean plastic, |
307 | Pipette Stand | It should provide easy access and storage for 10 pipettes of varying sizes. Made of light, easy-to-clean plastic, |
308 | Plastic Container For Specimens | Transparent, Screw cap lid High Quality Plastic 500 ml |
309 | Plastic Container For Specimens | Transparent Screw cap lid High Quality Plastic 1000 ml |
310 | Plastic Container For Specimens | Transparent Screw cap lid High Quality Plastic 5000 ml |
311 | Plastic dropper bottle | ISO ,white colour, Thick plastic bottle,100 ml capacity; 1 piece |
312 | Plastic Embedding Cassattes | High quality plastic material, Durable for Paraffin tissue blocks.; 100 piece |
313 | Plastic test tube with screw cap | For pilot blood sample , ISO Compare Disposable Plastic Test Tube;100 nos |
314 | Poly Lysine coated slide | three forth of the slide coated, 75X25X1.3 mm3, 50 slides/box |
315 | PT cuvette | used in semi automated,coagulometer (stago machine )1box=600 cuvette |
316 | RBC PIPETTE | MADE FROM VERY HIGH QUALITY IMPORTED GLASS MATERIAL WHICH ENSURES DURABILITY with rubber teat; 1 piece |
317 | RUBBER TEATs(RED color) FOR PIPETTE | Good quality rubber; 100 pieces |
318 | Sample Cup for ACL TOP CTS 300 | Sample Cup for Fully automatic coagulometer IL ACL TOP CTS 300. 2 ml size |
319 | Slide Rack for Autostainer For Histopathology | Machine company: Leica ST5010-Model |
320 | Sodium heparin Vacuette 2ml | ISO, Size: 13 mm x 75 mm Additive: 30 USP Units of Sodium Heparin (freeze dried) ;100 pieces |
321 | Sodium heparin Vacuette 4ml | ISO, Size (mm): 16 mm x 100 mm Additive: 143 USP Units of Sodium Heparin (freeze dried); 100 pieces |
322 | Specimen Mounted rode | Size:medium/small/large as per specimen glass/plastic rods(readymade museum mounting rods) |
323 | Spirit lamp | Alluminium |
324 | Staining Jar &Lid | Glass, Size 8"x4"x4" Borosil or Good quality; 1 piece |
325 | Test tube | Glass, Kahn,Autoclavable, 12 x 100 mm, 1 Gross -144 tubes |
326 | Test tube | 6’’ x3/4 ‘’size, ISO, glass; 100 piece |
327 | Test tube | Glass- Autoclavable, 5" x 5/8 inch,1 Gross -144 tubes |
328 | Test tube | Polypeperine Plastic - Autoclavable, 5 ml capacity, 1 Gross -144 tubes |
329 | Test tube - Plastic | Plastic-conical bottom screw cap with graduation mark,Autoclavable, Dimension 16 x 120 mm,polypropylene, maximum RCF value : 6000 g, 15 ml capacity |
330 | Tips holder rack | 96 hole for small micro tips (yellow coloured 100 microlitre); 1 piece |
331 | Tips holder rack | 96 hole for large microtips (Blue coloured 1ml); 1 piece |
332 | Tissue Paper Roll | Good Quality, Double Layer, Laboratory Use.; 1 piece |
333 | Tissue paper roll | Tissue paper roll - perforated, supersoft hygienic & absorbant tissue, Length - 57 meter, width - 0.1 meter |
334 | Tissue Processing Embedding cassettes | Made from acetyl polymer which is special high density polymer that keeps specimens safely submerged in solution.This cassettes are totally resistant to most histological solventsand their slots offer maximum flow through for good fluid exchange & proper drainage. The lids either come attached to the cassette or are packeged separately.1000/pack,500/pack |
335 | Urin strip | For 12 parameters (albumin,pH,specific gravity, ketone, sugar, urobilinogen, Blood/RBC, bilirubin, leucocyte, nitrites,ascorbic acid) 150 strips per pack |
336 | Urine Strips | only for Glucose; each bottle contain 100 strips |
337 | Wasserman test tube neutral glass | ISO, 4’’ x ½ ‘’ size |
338 | WBC PIPETTE | MADE FROM VERY HIGH QUALITY IMPORTED GLASS MATERIAL WHICH ENSURES DURABILITY with rubber teat; 1 piece |
339 | Sticker roll | 1 x100 per pack |
340 | Carbon paper | 1 x20 per pack |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy