Tender For Annual Plan-Electrification Providing Amf Panel Inverter And Solar Panel For Anjukunnu Homeo Hospital-269, wayanad-Kerala

Local Self Government Department has published Tender For Annual Plan-Electrification Providing Amf Panel Inverter And Solar Panel For Anjukunnu Homeo Hospital-269. Submission Date for this Tender is 28-06-2023. Electrification Work Tenders in wayanad Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

38289945
Tender For Annual Plan-Electrification Providing Amf Panel Inverter And Solar Panel For Anjukunnu Homeo Hospital-269
Open Tender
Indian
Kerala
wayanad
28-06-2023

Tender Details

Annual Plan-Electrification Providing Amf Panel Inverter And Solar Panel For Anjukunnu Homeo Hospital-269

Key Value

Document Fees
INR 1815 /-
EMD
INR 20559.0 /-
Tender Value
INR 8.22 Lakhs /-

BOQ Items

Work Name:Annual Plan-ELECTRIFICATION, PROVIDING AMF PANEL, INVERTER AND SOLAR PANEL FOR ANJUKUNNU HOMEO HOSPITAL-423/23-General Electrical Work- PR NO.423/23
Sl. No. Item Description
1ELECTRIFICATION
21.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
31.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
41.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
51.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
61.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
71.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
81.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
91.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
101.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
111.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
121.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
131.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
141.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
151.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
161.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
171.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
181.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
1990.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thicknesscomplete with all accessories andlamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
2090.3.21.3:Supply & installation of light fittings on "C/U" shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories andlamps etc. directly on wall using 2 nos. "C/U" brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
21OD15971/2023-2024:Supply installation and commissioning of wall fan(400mm,3 blades) with 90-degree oscillation and speed control by pull cord system. in existing 6amp socket/ ceiling rose. Including giving connections with a required length of 24/.20mm PVC SHEATHED 3CORE ROUNG COPPER CONDUCTOR FLEX WIRE CONFORMING TO RELEVANT iss suitable for working in 240v Ac supply.
22OD24786/2023-2024:Supply installation and commissioning of pedestal fan(400mm,3 blades) with 90-degree oscillation with the speed control system in existing 6amp socket Including giving connections with a required length of 24/.20mm PVC SHEATHED 3CORE ROUNG COPPER CONDUCTOR FLEX WIRE CONFORMING TO RELEVANT iss suitable for working in 240v Ac supply. (Havells Sprint,Usha, Cropton )
23OD15950/2023-2024:Supply and fixing of 9W LED
24OD15952/2023-2024:Supply conveyance installation testing and commissioning of the following sizes of exhaust fan in the existing opening fixing necessary bolt and nuts making good the damage etc. as required including giving connections with the required length of 24/.20mm PVC SHEATHED 3CORE ROUNG COPPER CONDUCTOR FLEX WIRE CONFORMING TO RELEVANT iss-300/305mm single-phase light-duty metal type exhaust fan in meter frame.
2590.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
2690.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
2790.3.17.1:Supply, conveyance and erection ofthe following sizes of "B" class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.32 mm dia GI pipe
2890.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
2990.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
3090.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
3190.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
3290.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
3390.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
349.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
352.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
362.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
372.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
38OD15973/2023-2024:Supplying and fixing 4Psheet steel enclosure on surface/ recess suitable for fixing 16/25/32amps 415 voltsMCB/isolator/RCCB as required.
392.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
40OD15972/2023-2024: Supplying and fixing 40 amps rating, 240/415 volts, Changeover switch of following poles in the existing MCB DB complete with connections, testing, and commissioning, etc. as required. Double pole. (Havells- DHMGODPX040 OR equivalent)
412.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
422.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
435.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
445.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
455.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
46OD15954/2023-2024:DISMANTLING OF EXISTING ELECTRICAL POINTS
471.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
481.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
491.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
50OD15975/2023-2024:Supplying and drawing the following sizes of FRLS PVC insulated copper conductors, 6 core flexible cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
51OD15980/2023-2024:Supply Installation, testing and commissioning of 15 KVA AMF Panel suitable for the existing Ashok Leyland engine complete with the following. 1) 4 Pole MCB for DG incoming / EB Incoming. 2) CT Coil Poly Carbonate Class 1 Accuracy 3) Battery Charger Automatic Cut off with Float & Boost with reverse Power Protecion. 4) LED Indication Lamp for EB/DG Status & RYB Indication 5) MS Control Panel IP56 Class with Wall mounted Powder coated Control panel (1.2MM thick) 6) 4 Pole contactors or ATS -63A El measure make 7) Panel Earthing.
52OD24709/2023-2024:Supply, complete installation and testing of 5.2KVA 48/96 Volt (THD<3%)True sine wave inverter/UPS(copper winding) with inbuilt MPPT suitable for 5kw solar panel installation and with automatic change-over switch inbuilt, digital display, 32-bit DSP, with surge load up to 300%(Luminous, V guard, Exide or equivalent) compactable with 150Ah (C10) recyclable lead acid tower tubular type battery(s). With its floor, mounding trolly stands. Must provide3 years full warranty as required. The inverter must have 1 phase IN &1 phase OUTs with its tinned connecting leads for batteries.
53OD24710/2023-2024:Supply, installation, testing and commissioning of 545 watts solar panel(mono PERC) with standard dimensions (2.2mx1.1mx0.035m) required to produce min. of 500 watts per panel in normal sunlight. Fixing it to the existing structure with necessary electrical connections. (Make- Havells, Luminous, Kirloskar or equivalent)
5490.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
55OD24791/2023-2024:Supply and complete installation of 150Ah/12V (C10) recyclable, high charge rate lead acid tower tubular type battery(s) with connector along with the battery to the existing inverter as directed .(luminous, Exide or equivalent) provided with 5 years replacement warranty. (Includes transportation/cartage charge)
56OD15982/2023-2024:Supply and complete installation of 90Ah/12V (C10) recyclable, high charge rate lead acidBED type battery(s) with connector along with the battery connects to the existing DG set as directed .(luminous, Exide or equivalent) provided with 3 years maintenance and warranty. (Includes transportation/cartage charge)
571.17.29:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 6 sq. mm
58OD24782/2023-2024:Supply and fixing of 600V DCDB 2 string 2 in 2 out with 16A dc DP mcb surge protector (Voltage protection level (Up): 0.5kV/0.3kV.) for solar installation protection with mcb DB/enclosure(IP 67) and giving connection as required. SPD according to IEC 61643-31& EN 50539.Nominal Discharge Current up to 4kA.
595.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
60OD24789/2023-2024:Supply installation and repair of damaged required size gun metal bush for 2hp pump set (DECCAN). This includes dismantling of damaged submersible vertical pump set and dismantling of damaged bushes and replacing it with new ones. with an appropriate size suitable for the existing motor.
61OD33940/2023-2024:2 HP pump motor leading to the nearest roadside, loading into the vehicle and conveying to the workshop including leading, loading and unloading at the workshop. Separate the motor into stator & rotor rewind the burnt stator after removing the damaged winding from the slots, cleaning the slots neatly, insulating the slots by using correct class Nomex paper, winding the stator with good quality original gauge super enamelled copper winding wires, closing the slot with fibre glass wedges, inserting proper interlayer insulation, making the coil end connections, providing new lead wire, sockets, rubber bushes etc. Binding the overhang with proper insulation at both ends, heating the coils and varnishing with good quality insulation varnish, keeping it for drying, reassembling and conveying to pump house and refitting, test run etc as required(scrap copper amount is deducted in the item rates).
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail