Tender For Supply Installation Testing Commissioning Of Ups And Associated Electrical Work In Medical Gas Manifold Plant At Bhagwan Mahavir Hospital Pitampura Delhi, delhi-Delhi

Public Works Department-PWD has published Tender For Supply Installation Testing Commissioning Of Ups And Associated Electrical Work In Medical Gas Manifold Plant At Bhagwan Mahavir Hospital Pitampura Delhi. Submission Date for this Tender is 27-06-2023. Electrical Maintenance Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

38253166
Tender For Supply Installation Testing Commissioning Of Ups And Associated Electrical Work In Medical Gas Manifold Plant At Bhagwan Mahavir Hospital Pitampura Delhi
Open Tender
Indian
Delhi
delhi
27-06-2023

Tender Details

Tender For Supply Installation Testing Commissioning Of Ups And Associated Electrical Work In Medical Gas Manifold Plant At Bhagwan Mahavir Hospital Pitampura Delhi

Key Value

Document Fees
Refer document
EMD
INR 20797.0 /-
Tender Value
INR 10.39 Lakhs /-

BOQ Items

Name of Work: SITC of UPS and associated electrical work in Medical Gas Manifold Plant at Bhagwan Mahavir Hospital, Pitampura Delhi.
Sl. No. Item Description
1Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
25/6 A switch
33 pin 5/6 A socket outlet
4Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
53 Module (100 mmX75 mm)
6Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
78 way , Double door
8Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
9For 10 way, Double door SPN MCBDB
10Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
11Single pole
12Double pole
13Supplying,Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of followingsize copper conductor flexible cable on wall surface as required.
143 X 10 sq. mm
15Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
162 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
17Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
183 X 10 sq. mm (25 mm)
19Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
20Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
21Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
22Supplying, Installation, Testing and Commissioning of 31-36 Watthaving approx. dimensions of 600mm x 600mm, recess mounted 2X2 LED fitting white powder coated CRCA Housing ,Over Voltage Protection, minimum CRI of 80, THD<10%etc. as reqd.
23Supplying, Installation, Testing and Commissioning of surface/wall Mounted 20 Watt LED tube with 4 feet batten fitting, LED tube should have polycarbonate housing for efficient heat dissipation, in cool day light (5700 K to 6500 K) as required i/c connection with 1.5 Sq.mm. FRLS PVC insulated copper conductor, single core cable etc. as reqd.
24Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required i/c dismantling charges of existing fan and less credit for the same.
25Supply of 10 KVA ON LINE UPS Three Phase input and Single Phase output with following features : High frequency PWM Invertor using IGBT Manual / Automatic Bypass switch, ALPHA Numeric LCD Display with SMF, In-Built isolation transformer including maintenance free battery backup 30 minutes including suitable size of Battery Rack etc. Complete as reqd.