Tender For Repairing Work Of Wall, Ceiling, Floor, Doors And Windows At The 5 Rooms Of The Land Acquisition Section, 3Rd Floor Of Administrative Building, District Magistrate And Collector, North 24 Parganas, Under Barasat Division, P.W.Dte (2Nd Call), barasat-West Bengal

Public Works Department-PWD has published Tender For Repairing Work Of Wall, Ceiling, Floor, Doors And Windows At The 5 Rooms Of The Land Acquisition Section, 3Rd Floor Of Administrative Building, District Magistrate And Collector, North 24 Parganas, Under Barasat Division, P.W.Dte (2Nd Call). Submission Date for this Tender is 04-07-2023. Civil Work Tenders in barasat West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

38249267
Tender For Repairing Work Of Wall, Ceiling, Floor, Doors And Windows At The 5 Rooms Of The Land Acquisition Section, 3Rd Floor Of Administrative Building, District Magistrate And Collector, North 24 Parganas, Under Barasat Division, P.W.Dte (2Nd Call)
Open Tender
Indian
West Bengal
barasat
04-07-2023

Tender Details

Repairing Work Of Wall, Ceiling, Floor, Doors And Windows At The 5 Rooms Of The Land Acquisition Section, 3Rd Floor Of Administrative Building, District Magistrate And Collector, North 24 Parganas, Under Barasat Division, P.W.Dte ( 2Nd Call )

Key Value

Document Fees
Refer document
EMD
INR 5542.0 /-
Tender Value
INR 2.77 Lakhs /-

BOQ Items

Name of Work:Repairing work of wall, ceiling, floor, doors and windows at the 5 rooms of the Land Acquisition Section, 3rd floor ofAdministrativebuilding, District Magistrate & Collector, North 24 Parganas, under Barasat division, P.W.Dte (2nd Call)
Sl. No. Item Description
1Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
2Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the e×posed surface and removing debris from site complete as per direction of the Engineer - in - Charge.
3Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer"s specification][Mode of measurement:The affected surface area of reinforcement shall be considered for payment]
4Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer"s specification [Cement to be supplied by the Department]
5Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributingthe same and with proper scarping and cleaning the reinforcement and disturbed concrete with wire brush etc. after applying a coat of cementincluding the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge.
6Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (b) With 1:6 cement morter, 20 mm thick plaster, in Interior wall
7c) With 1:4 cement morter, 10 mm thick plaster, in Ceiling
8Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge).
9Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC. (In Ground Floor) (b) Two Coat i) Water based interior grade Acrylic Primer
10Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Standard Quality
11Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
12(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : b) On steel or other metal surface : With other than hi-gloss of approved quality- (iv) Two coats (with any shade except white)
13Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6m height for external wall)
14Extra for fixing glass panes in steel window
15Easing door and windows.
16Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately)
17Taking out shutter of door and window, dismantling by parts (for repair or replacement of damaged parts) , reassembling and refitting and rehanging same with old fittings but with new screws as necessary. (Where different parts of same shutter are renewed under different item, payment under item 73 will be made once only).
18Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303-1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in Charge.[excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor
19Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both waysin order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including itting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.
20Iron skeleton bolt of approved quality fitted and fixed complete.
21ii) Door stopper (Anodised aluminium)
22i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.
23Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. v) 75mm. × 60mm. × 3.15mm.
24Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:
25(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
26(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary (a) On timber or plastered surface With other than hi-gloss of approved quality- v) Two coats (with any shade except white)
27Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.
28Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges there of.
29Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directedwith topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement
30ADD :GST - 18% (SGST = 9% & CGST =9%)
31ADD : WEST BENGAL LABOUR WELFARE CESS = 1%