Heavy Industries and Public Enterprises Government Departments Closing in 0 days TDR #38248878

Tender For Setting Up Of Computer Lab At M.R.S Kulathupuzha , Kollam

Issued by Government Departments · kulathupuzha, Kerala
Tender Value
19.10 Lakhs
Estimated cost
Bid Submission
26 Jun 2023
0 days left
EMD
47774
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kulathupuzha → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Setting Up Of Computer Lab At M.R.S Kulathupuzha , Kollam

BOQ

Work Name : Setting up of Computer lab at M.R.S Kulathupuzha , Kollam
Sl. No. Item Description
1FURNITURE
2od8176/2021_2022 : Supply of revolving chair of reputed make: Chair for PC users 120mm Seat upholstered with PU<br>foam & back with mesh: Imported fabrics
3od8177/2021_2022 : Supply of Faculty Table of reputed make: 1 Seater PC Table with Pre-lam finish or better, Table length: 4' x Width: 2' 6" & 18mm thick tabletop & gable ends, Pre-lam modesty thickness: 18mm or better
4od8178/2021_2022 : Supply of PC Table ofReputed make: 6 Seater Double side (3+3) PC Table with Pre-lam finish or better, Table length: 7' 10" xWidth:3' 5" & 18mm thick tabletop & gable ends, Pre-lam modesty thickness: 18mm or better, Top Color Options – Std prelam shade card
5NETWORKING WORKS
6od8344/2021_2022 : Supply,conveyance and installation of 12U Wall mount Rack with accessories
7od8345/2021_2022 : Supplying and fixing 28-Port Gigabit Managed Switch with following Specification Spanning Tree Protocol,Port grouping Up to 8 groups,VLAN Support for up to 4096 VLANs simultaneously ,Port-based and 802.1Q tag-based VLANs,MAC-based VLAN,Management VLAN, Private VLAN Edge (PVE), also known as protected ports, with multiple uplinks,DHCP snooping Filters out DHCP messages with unregistered IP addresses and/or from unexpected or untrusted interfaces.This prevents rogue devices from behaving as DHCP Servers (Cisco/Linksys/D-Link)
8od8346/2021_2022 : Wireless Router with power, activity indicators, Frequency Band:2.4 GHz or better, Encryption algorithm: 128-bit WEP, WPA, WPA2 or better, Routing protocol: RIP, static IP routing, Data Link Protocol: Ethernet,IEEE or better, Data transfer rate: 300 Mbps or better, Connectivity: 1x 10/100 WAN, 4x 10/100 LAN or better, Platform compatibility: Mac, Windows (Cisco/Linksys/D-link)
990.9.1.1 : Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.
10od8416/2021_2022 : Supply,conveyance and installation of 24 Port Patch panel loaded with all accessories as required.
11od8426/2021_2022 : Supply and fixing of 1 mtr patch cord for PC.
12od8427/2021_2022 : Supply and installation of Information Outlet for existing box as required.
131.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
141.28.3 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
151.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
161.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
171.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
181.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
191.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
201.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
2190.10.1.4 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )
2290.10.1.6 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )
2390.10.1.1 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )
24od8429/2021_2022 : Supplying and fixing of Cable Management - Single U of standard make as approved by the site engineer in charge (LMR)
25od14489/2021_2022 : Supplying and fixing of trunking 150mmx80mm in meters.
261.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
27od15537/2021_2022 : Supplying and fixing of External SMF Batterry 12V,65 AH 20 Nos. for the battery back up 45- 50 mins Minutes Battery backup with cables.
28od15538/2021_2022 : Supplying and fixing of Three Phase in and 1 Phase Out 15kVA Online Double conversion UPS system with DSP based technology, Input Nominal Voltage: 220/380 Vac, 230/400 Vac, 240/415 Vac, Power Factor: >.95(full load), Output Voltage: 220/230/240 Vac, Built-in manual bypass, Battery Voltage: 240Vdc, Built in 4A Charge Current, Efficiency 91% @ Online mode, 96% @ ECO Mode, Built in Maintanance bypass switch or better.
292.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
302.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
312.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
322.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
332.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
342.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
35od16915/2021_2022 : Installing and connecting a 2.5 Mtr.long 100mm Dia C.I. Pipe with holes drilled diametrically opposite to each other once every 300mm. in an earth pit of 380 x380 x 3000mm.filled with salt and charcoal mixed with sand in alternate layers 150 mm each upto a height of 2500mm. from bottom. The pipe shall have provision for watering through a funnel. It shall also have provision for connecting 50 x 6 mm.GI Flat on two sides. A masonary strucutre shall be constructed to a depth of 750 mm.and a CI cover shall be used to cover the pit.The cost of digging and back filling shall also be included or better
36od16916/2021_2022 : Supplying and fixing 40 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.<br>Triple pole
37od16965/2021_2022 : Supply, laying & fixing of Earth champer consruction and covering with MS lid.
381.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excludingmodular plate as required.
39od17075/2021_2022 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )<br>25A DP switch
401.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
411.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
421.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B
431.14.8 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire
441.14.9 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mmearth wire
451.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
461.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
471.54.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
4890.10.3.33 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )
49od17286/2021_2022 : Supply, installation, Testing of IP43 category 4 Pole MCB Box with necessary accessories as required.
502.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
5190.11.1.10 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
522.11 : Supplying and fixing single pole blanking plate inthe existing MCB DB complete etc. as required.
53od17342/2021_2022 : Supply and installation of 20W LED tubelight with all accesssories as required. (Make:Crompton/Philips/Wipro)
54od17390/2021_2022 : Supplying and laying of 25 mm Heavy Duty Casing & Capping - ISI Marked or better
5590.16.5.4 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.
5690.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

AI Tender Summary

OUR REF NO 38248878
AUTHORITY Government Departments
TENDER VALUE 19.10 Lakhs
LAST DATE 26-06-2023
Authority
Authority Name Steel Industrials Kerala Limited
Work Description Tender For Setting Up Of Computer Lab At M.R.S Kulathupuzha , Kollam
Basic Detail
Tender No SILK/PED/S-3647/2023-24/685
Bidding Type Tender
Location
City kulathupuzha
State Kerala
Key Dates
Publish Date 19 Jun 2023
Submission Date 26 Jun 2023
Open Date 27 Jun 2023
Finance
Tender Value 19.10 Lakhs
Tender Fee 2950
EMD 47774
Exemption Not Available
Document List
Tendernotice_1.pdf
02779077-59a2-4a48-8b43-232708ee539f.html
BOQ_860702.xls
GCC.pdf
PROFILE.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 19, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 26, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 27, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

02779077-59a2-4a48-8b43-232708ee539f.html

xls

BOQ_860702.xls

pdf

GCC.pdf

pdf

PROFILE.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders