Tender For Procurement Of Different Types Of Power Cables For Esp, Ahp & Foph Area,Stg-I & Ii, Sgtpp
Tender Overview
Project Description
Tender For Procurement Of Different Types Of Power Cables For Esp, Ahp & Foph Area, Stg-I & Ii, Sgtpp--- 1 Procurement of Different types of Power Cables for ESP, AHP & FOPH Area,Stg-I & II, SgTPP 2 CABLE,ALUMINIUM CONDUCTOR,16 MM2,4 CORE # ALUMINIUM CONDUCTOR 1.1 GRADE STRANDED XLPE INSULATED CORES LAID UP PVC TAPE INNER SHEATHED SINGLE LAYER OF GALVANIZED FLAT STEEL STRIP ARMOURED OVERALL PVC OUTER SHEATHED CONFIRMING TO IS:7098 (PART 1) 1988 WITH LATEST AMENDMENTS SIZE 16 SQ MM 4 COR ( BALANCE STRANDED ALUMINIUM CONDUCTOR, PVC INNER SHEATHED, EXTRUDED PVC TYPE ST2 COMPOUND OUTER SHEATHED, CONFORMING TO IS: 7098, PART-1/ 1988 WITH LATEST AMENDMENT, MINIMUM CONTINUOUS LENGTH: 500 MTR., TOLERANCE IN LENGTH: +/-5%, EACH CORE CODED BY DIFFERENT COLOUR. Cable should be of brands: POLYCAB OR KEI OR GLOSTER CABLES OR HAVELLS CABLES OR RPG CABLES. ) 3 CABLE, AL, 3.5CX25MM2, XLPE, 1.1KV GRADE XLPE INSULATED ( BALANCE STRANDED ALUMINIUM CONDUCTOR, PVC INNER SHEATHED, EXTRUDED PVC TYPE ST2 COMPOUND OUTER SHEATHED, CONFORMING TO IS: 7098, PART-1/ 1988 WITH LATEST AMENDMENT, MINIMUM CONTINUOUS LENGTH: 500 MTR., TOLERANCE IN LENGTH: +/-5%, EACH CORE CODED BY DIFFERENT COLOUR. Cable should be of brands: POLYCAB OR KEI OR GLOSTER CABLES OR HAVELLS CABLES OR RPG CABLES. ) 4 CABLE,AL,3.5CX 35 MM2,XLPE,ARMOURED # CABLE LT POWER ALUMINIUM CONDUCTOR XLPE INSULATED ARMOURED WITH FLAT GALVANISED STEEL STRIP 1.1KV GRADE 3.5 CORE X 35 SQ MM. ( BALANCE STRANDED ALUMINIUM CONDUCTOR, PVC INNER SHEATHED, EXTRUDED PVC TYPE ST2 COMPOUND OUTER SHEATHED, CONFORMING TO IS: 7098, PART-1/ 1988 WITH LATEST AMENDMENT, MINIMUM CONTINUOUS LENGTH: 500 MTR., TOLERANCE IN LENGTH: +/-5%, EACH CORE CODED BY DIFFERENT COLOUR. Cable should be of brands: POLYCAB OR KEI OR GLOSTER CABLES OR HAVELLS CABLES OR RPG CABLES. ) 5 CABLE,AL,3.5CX70 MM2 # XLPE INSULATED,1.1KV GRADE ( BALANCE STRANDED ALUMINIUM CONDUCTOR, PVC INNER SHEATHED, EXTRUDED PVC TYPE ST2 COMPOUND OUTER SHEATHED, CONFORMING TO IS: 7098, PART-1/ 1988 WITH LATEST AMENDMENT, MINIMUM CONTINUOUS LENGTH: 500 MTR., TOLERANCE IN LENGTH: +/-5%, EACH CORE CODED BY DIFFERENT COLOUR. Cable should be of brands: POLYCAB OR KEI OR GLOSTER CABLES OR HAVELLS CABLES OR RPG CABLES. ) 6 AL XLPE LT POWER CABLE,3C *150 SQMM ( BALANCE STRANDED ALUMINIUM CONDUCTOR, PVC INNER SHEATHED, EXTRUDED PVC TYPE ST2 COMPOUND OUTER SHEATHED, CONFORMING TO IS: 7098, PART-1/ 1988 WITH LATEST AMENDMENT, MINIMUM CONTINUOUS LENGTH: 500 MTR., TOLERANCE IN LENGTH: +/-5%, EACH CORE CODED BY DIFFERENT COLOUR. Cable should be of brands: POLYCAB OR KEI OR GLOSTER CABLES OR HAVELLS CABLES OR RPG CABLES. ) 7 CABLE,3C,185MM2,1100/1100V,AL,STRANDED # 85DEGC RATING HEAVY DUTY POWER CABLES WITH STRANDED AL ( LT Power cable. Grade-1.1 KV, Stranded Aluminum Conductor, 3C, 185 Sq. Mm, FRLS, XLPE-Insulated. Stranded compacted sector shaped aluminum conductor, color coded ,Each core Laid up, Extruded PVC inner sheathed, Single layer of Galvanized flat steel strip armoured and overall PVC sheathed cable conforming to IS: 7098(part-1)/1988. Cable should be of brands: POLYCAB OR KEI OR GLOSTER CABLES OR HAVELLS CABLES OR RPG CABLES. ) 8 CABLE,2C,120MM2,1100/1100V,AL,STRANDED # 85DEGC RATING HEAVY DUTY POWER CABLES WITH STRANDED AL C ( BALANCE STRANDED ALUMINIUM CONDUCTOR, PVC INNER SHEATHED, EXTRUDED PVC TYPE ST2 COMPOUND OUTER SHEATHED, CONFORMING TO IS: 7098, PART-1/ 1988 WITH LATEST AMENDMENT, MINIMUM CONTINUOUS LENGTH: 500 MTR., TOLERANCE IN LENGTH: +/-5%, EACH CORE CODED BY DIFFERENT COLOUR. Cable should be of brands: POLYCAB OR KEI OR GLOSTER CABLES OR HAVELLS CABLES OR RPG CABLES. )
BOQ
| Sl. No. | Item Description |
| 1 | Procurement of Different types of Power Cables for ESP, AHP & FOPH Area,Stg-I & II, SgTPP |
| 2 | CABLE,ALUMINIUM CONDUCTOR,16 MM2,4 CORE # ALUMINIUM CONDUCTOR 1.1 GRADE STRANDED XLPE INSULATED CORES LAID UP PVC TAPE INNER SHEATHED SINGLE LAYER OF GALVANIZED FLAT STEEL STRIP ARMOURED OVERALL PVC OUTER SHEATHED CONFIRMING TO IS:7098 (PART 1) 1988 WITH LATEST AMENDMENTS SIZE 16 SQ MM 4 COR ( BALANCE STRANDED ALUMINIUM CONDUCTOR, PVC INNER SHEATHED, EXTRUDED PVC TYPE ST2 COMPOUND OUTER SHEATHED, CONFORMING TO IS: 7098, PART-1/ 1988 WITH LATEST AMENDMENT, MINIMUM CONTINUOUS LENGTH: 500 MTR., TOLERANCE IN LENGTH: +/-5%, EACH CORE CODED BY DIFFERENT COLOUR. Cable should be of brands: POLYCAB OR KEI OR GLOSTER CABLES OR HAVELLS CABLES OR RPG CABLES. ) |
| 3 | CABLE, AL, 3.5CX25MM2, XLPE, 1.1KV GRADE XLPE INSULATED ( BALANCE STRANDED ALUMINIUM CONDUCTOR, PVC INNER SHEATHED, EXTRUDED PVC TYPE ST2 COMPOUND OUTER SHEATHED, CONFORMING TO IS: 7098, PART-1/ 1988 WITH LATEST AMENDMENT, MINIMUM CONTINUOUS LENGTH: 500 MTR., TOLERANCE IN LENGTH: +/-5%, EACH CORE CODED BY DIFFERENT COLOUR. Cable should be of brands: POLYCAB OR KEI OR GLOSTER CABLES OR HAVELLS CABLES OR RPG CABLES. ) |
| 4 | CABLE,AL,3.5CX 35 MM2,XLPE,ARMOURED # CABLE LT POWER ALUMINIUM CONDUCTOR XLPE INSULATED ARMOURED WITH FLAT GALVANISED STEEL STRIP 1.1KV GRADE 3.5 CORE X 35 SQ MM. ( BALANCE STRANDED ALUMINIUM CONDUCTOR, PVC INNER SHEATHED, EXTRUDED PVC TYPE ST2 COMPOUND OUTER SHEATHED, CONFORMING TO IS: 7098, PART-1/ 1988 WITH LATEST AMENDMENT, MINIMUM CONTINUOUS LENGTH: 500 MTR., TOLERANCE IN LENGTH: +/-5%, EACH CORE CODED BY DIFFERENT COLOUR. Cable should be of brands: POLYCAB OR KEI OR GLOSTER CABLES OR HAVELLS CABLES OR RPG CABLES. ) |
| 5 | CABLE,AL,3.5CX70 MM2 # XLPE INSULATED,1.1KV GRADE ( BALANCE STRANDED ALUMINIUM CONDUCTOR, PVC INNER SHEATHED, EXTRUDED PVC TYPE ST2 COMPOUND OUTER SHEATHED, CONFORMING TO IS: 7098, PART-1/ 1988 WITH LATEST AMENDMENT, MINIMUM CONTINUOUS LENGTH: 500 MTR., TOLERANCE IN LENGTH: +/-5%, EACH CORE CODED BY DIFFERENT COLOUR. Cable should be of brands: POLYCAB OR KEI OR GLOSTER CABLES OR HAVELLS CABLES OR RPG CABLES. ) |
| 6 | AL XLPE LT POWER CABLE,3C *150 SQMM ( BALANCE STRANDED ALUMINIUM CONDUCTOR, PVC INNER SHEATHED, EXTRUDED PVC TYPE ST2 COMPOUND OUTER SHEATHED, CONFORMING TO IS: 7098, PART-1/ 1988 WITH LATEST AMENDMENT, MINIMUM CONTINUOUS LENGTH: 500 MTR., TOLERANCE IN LENGTH: +/-5%, EACH CORE CODED BY DIFFERENT COLOUR. Cable should be of brands: POLYCAB OR KEI OR GLOSTER CABLES OR HAVELLS CABLES OR RPG CABLES. ) |
| 7 | CABLE,3C,185MM2,1100/1100V,AL,STRANDED # 85DEGC RATING HEAVY DUTY POWER CABLES WITH STRANDED AL ( LT Power cable. Grade-1.1 KV, Stranded Aluminum Conductor, 3C, 185 Sq. Mm, FRLS, XLPE-Insulated. Stranded compacted sector shaped aluminum conductor, color coded ,Each core Laid up, Extruded PVC inner sheathed, Single layer of Galvanized flat steel strip armoured and overall PVC sheathed cable conforming to IS: 7098(part-1)/1988. Cable should be of brands: POLYCAB OR KEI OR GLOSTER CABLES OR HAVELLS CABLES OR RPG CABLES. ) |
| 8 | CABLE,2C,120MM2,1100/1100V,AL,STRANDED # 85DEGC RATING HEAVY DUTY POWER CABLES WITH STRANDED AL C ( BALANCE STRANDED ALUMINIUM CONDUCTOR, PVC INNER SHEATHED, EXTRUDED PVC TYPE ST2 COMPOUND OUTER SHEATHED, CONFORMING TO IS: 7098, PART-1/ 1988 WITH LATEST AMENDMENT, MINIMUM CONTINUOUS LENGTH: 500 MTR., TOLERANCE IN LENGTH: +/-5%, EACH CORE CODED BY DIFFERENT COLOUR. Cable should be of brands: POLYCAB OR KEI OR GLOSTER CABLES OR HAVELLS CABLES OR RPG CABLES. ) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender