Tender For Repair Maint Of Stp Treated Water Pipe Lines Cleaning Of Tank Air Blowers Pumps Motors Control Valves Control Electric Panels Filter Media Flow Meter Ms Pipe And Allied Works Of Stp In The Aor Of Age U Water Supply No Ii Under Ge U W S Del, delhi-Delhi

Military Engineer Services-MES has published Tender For Repair Maint Of Stp Treated Water Pipe Lines Cleaning Of Tank Air Blowers Pumps Motors Control Valves Control Electric Panels Filter Media Flow Meter Ms Pipe And Allied Works Of Stp In The Aor Of Age U Water Supply No Ii Under Ge U W S Del. Submission Date for this Tender is 20-07-2023. Water Pipe Line Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

38247823
Corrigendum : Tender For Repair Maint Of Stp Treated Water Pipe Lines Cleaning Of Tank Air Blowers Pumps Motors Control Valves Control Electric Panels Filter Media Flow Meter Ms Pipe And Allied Works Of Stp In The Aor Of Age U Water Supply No Ii Under Ge U W S Del
Open Tender
Indian
Delhi
delhi
20-07-2023

Tender Details

Repair Maint Of Stp Treated Water Pipe Lines Cleaning Of Tank Air Blowers Pumps Motors Control Valves Control Electric Panels Filter Media Flow Meter Ms Pipe And Allied Works Of Stp In The Aor Of Age U Water Supply No Ii Under Ge U W S Delhi Cantt10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Jul-2023 Date Date 13-07-2023
2 13-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work:REPAIR/MAINT OF STP TREATED WATER PIPE LINES, CLEANING OF TANK, AIR BLOWERS, PUMPS, MOTORS, CONTROL VALVES, CONTROL ELECTRIC PANELS, FILTER MEDIA, FLOW METER, MS PIPE AND ALLIED WORKS OF STP IN THE AOR OF AGE (U) WATER SUPPLY NO-II UNDER GE (U) W/S DELHI CANTT-10
Sl. No. Item Description
1Labour only for attending & rectifying of day to day treated water supply complaints of all nature, ie leakage in STP pipe lines,no water supply,any blockage rectifying defects in STP plant etc in all days including sunday & gazzetted Holidays in the AOR of AGE (U) W/S No - II complete all as specified and directed by Engineer-in-charge. Note :- 1. Note as mentioned below under item No 2 shall be deemed included for Ser item No 1 also. Cost effect if any shall be included in quoted unit rate. 2. All other parts required for replacement of STP plant shall be measurement and paid seperately under respective items.
2Labour only for attending & rectifying of Electric supplycompliants of day to day maintenace of existing LT Panels including connecting electrical accessories / spares of water supply installation and electrical fitting & light, short circuits in Pump housecomplete all as specified and directed. Note :-Any material required for attending complaints shall bemeasured & paid separately under respectvie item hereinafter)
3Notes for Item No 1.00 &2.00 (a) The complaints shall be attended and the defetcs shall be rectified by a team of ITI passed electrician or 12th passed qualified having minimum 03 years experienced. Electrician / Plumber as applicable assisted with adequate / sufficient quantity of helpers as directed by Engineer-in-charge (b) The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which double the quoted unit rate alongwith a penalty @ Rs 500/- per complaint per day (08 hrs) shall be levied upon/imposed in RAR of the ageement. (c) In case , after checking & attending the defect, if it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep team.IfEngineer-in- charge is satisfied with contractors view, no recovery will be made. (d) While attending the complaint of water supply/Electric supply if earth workis required then the same shall be measured and paid seperately under appropriate itemof Sch "A".However , NO extra payments shall be made for dewatering by means of pumping set/manually as suitable arranged by the contractor.
4(e)Cutting of GI pipe in position and threadingis also deemed to be included in the job rate (Fittings and fixtures will be measured and paid separetely under respective items of sch A). (f) All T&P required for attending the Complaints shall be provided by the contractor. (g) The Pipe Fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench ,Chain wrench, Caulking tools, Fusion Joint (Butt Joint) Electrical Machine, complete set of spanners and ladders etc. asrequired at site. (h) The Electrician shall always be in possession of all Electrician tools, LT Meggar,Earth tester, Multimeter, Crimping tool , insulation tape, Hand gloves etc required at site. (j)Old retrived materials shall be contractor"s property and will be removed by contractor after carrying out necessary recovery under "Sch of credit" rate as per CA.
5(k) Any other material required to attend the complaints at site will be provided by the contractor immediately, including Electrical heating fusion joint machine or pipe jointing material of any type and nature. (l) While attending complaints the necessary stores required for smooth functioning/rectifying the complaints are appended below under respective items heads.Thesse items willexclusively be measured against the complaints only. (m) Daily complaints of Treated Water pipe line leakages will be noted by rep of contractor at a common fixed suitable place with sitting arrangement consisting of "Table and Chair" arrangement and the contact number of his "REP" will be circulated widely among users by the contractor at NO extra cost. (n) Complaint register and complaint receipt prepared by contractor rep dully signed by JE E/M users and Engineer-in-charge will be kept on record.
6Supply and fixing in replacementonly of unsvgun metal gatevalve with iron wheel head screwedboth ends for iron pipe , ISI marked , as per IS : 778 of followingsizes complete all as specified and directed :-
715 mm bore
820 mm bore
925 mm bore
10Supply & Fixing in replacement of UPVC pipe of Pressure rating 10 Kgf/cm2 laid in trenchesincluding all fixture/fittings of following dia complete all as specified and directed :-
1115 mm bore
1220 mm bore
1350 mm bore
14110 mm bore
15160 mm bore
16Supply & Fixing of 3 Layer PPR pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PPR Plain and Brass threaded fitting in replacement of old unserviceable UPVC/HDPE/PPR Pipein trenches of following size complete all as specified and directed:-
1716 mm bore
1820 mm bore
1925 mm bore
2040 mm bore
2150 mm bore
2263 mm bore
2375 mm bore
2490 mm bore
25110 mm bore
26160 mm bore
27Supply & Fixing in replacement of old unserviceable High density polythne pipes (HDPE PIPE)) of pressure rating 10 kgf/ cm2 laid in trenches including all fitting including all accessories of following sizes complete all as specified and directed:-
2880 mm bore
29110 mm bore
30160 mm bore
31Boring holes under road pavement manually in any type of soil upto 200 mm bore by booky machine complete all as specified and directed.
32(Note:- Depth of boring holes below GL shall be decided by Engineer-in-charge as per site).
33Supply & Fixing PPR fittiings/connection PPR Socket/coupling plain or threaded as required at siteISI Marked of following sizes : -
3415 mmbore
3520 mm bore
3625 mm bore
3740mm bore
3850mmbore
3990mm bore
40110mmbore
41160mmbore
42Supply & Fixing PPR Elbow ISI Marked of complete all as directed of following sizes : -
4316 mmbore
4420 mm bore
4525 mm bore
46Supply & FixingPPR Union ISI Marked complete all as directed by EIC of following sizes : -
4716 mmbore
4820 mm bore
4925 mm bore
5040mm bore
5150mmbore
52Supply & FixingPPR reducing socket complete all as directed ISI Marked of following sizes : -
5325 x16 mmbore
5425 x 20 mm bore
5550 x 40mm bore
56110x90 mm bore
57160 x 110mmbore
58Supply & Fixing PP-R Gate valves (brass insert) as per requirement of the site of following size:-
5916 mm bore
6020 mm bore
6125 mm bore
6240 mm bore
6350 mm bore
64Supply & Fixing in replacement of old unserviceable GI tubing medium grade with all fitting laid in trenches/floor for bore of pipe of following sizes complete all as specified and directed :-
6515mmdia
6620mmdia
6725mmdia
6850mmbore
6980 mm bore
70Supply & Fixing in repair of Piano type switch flush type, 6 amps single pole, one way 240V complete all as specified and directed.
71Supply & Fixing in repair of Piano type switch, flush type, 16 amps single pole, one way 240V complete all as specified and directed.
72Supply & Fixing in repair of Switch socket outlet2 in 1,3/5 pin 5 Amps flush type, single pole, 240V complete all as specified and directed.
73Supply & Fixing in repair of Switch socket out let 2 in 1,3/5 pin 5/15 Amps flush type, single pole 240V complete all as specified and directed.
74Supply & Fixing in repair of PVC insulated multistranded coper conductor cable of size 1.5 sqmm, single core 1100 volts grade complete all as specified and directed.
75Supply & Fixing in repair ofPVC insulated multistranded coper conductor cable of size 2.5 sqmm, single core, 1100 volts grade complete all as specified and directed.
76Supply & Fixing in repair ofPVC insulated multistranded coper conductor cable of size 4 sqmm, single core, 1100 volts grade complete all as specified and directed.
77Supply & fixing LED tube light fitting integral type suitable for 1 x 20 watts, 230 Volts, connector block etc with all accessories internally prewired and including connecting with twin core flexible copper cable of suitable size including taking down/out fitting as existing at site complete all as specified and directed.
78Supplying & fixing of LED street light Fitting 70 watt 230 V AC outdoor type, IP-66 protection, with high pressure die cast aluminiumhosing including lamp bracket and angle with 3 core 1.5 sqmm pvc insulated cable compete all as specified and directed.
79Supply and fixing in replacement of PVC insulated, sheathed unarmoured Copper conductor flexible cable of size 10 sqmm single core round flexible, 1100 volts grade complete all as specified and directed.
80Supply and fixing in replacement of submersible copper cable of size 10 sqmm 4 core 1100 volts complete all as specified and directed
81Supply and fixing in replacement of submersible copper cable of size 6 sqmm 4 core 1100 volts complete all as specified and directed
82Supply & layingXLPE insulated PVC sheathed heavy duty underground cable with aluminium multi stranded conductorwith armoured 1100 volt grade of following sizes laid in trenches /duct ,wall connecting and testing complete all as specified and directed.
8316 sqmm 4 core
8425 sqmm 3.5 cre
8535 Sqmm3.5 core
8650 Sqmm3.5 core
87Supply and fixing in replacementof burnt & unserviceable 3 pole power contactor Type MNX 25, 110 Amp ,415/220 volts ,50 hz coil voltage 415 volt complete all as specified and directed.
88Supply and fixing in replacement of burnt & unserviceable 3 pole power contactor Type MNX 32, 110 Amp, 415/220 volts, 50 hz coil voltage 415 volt complete all as specified and directed.
89Supply and fixing in replacement of thermal over load relay type MN relay range 28-42 Amps complete all as specified and directed.
90Supply and fixingin replacement of burnt & unserviceable thermal over load relay type MN relay range 20-32 Amps complete all as specified and directed.
91Supply and fixing in replacement of burnt & unserviceable thermal over load relay type MN relay range 13-21 Amps complete all as specified and directed.
92Supply and fixing in replacement of burnt & unserviceable MCB single pole 6 to 32 Amp 240 volts complete all as specified and directed.
93Supply and fixing in replacement of burnt & unserviceable 3 pole power contactor type ML-4,70 Amps, 415 volts ,50 hz coil voltage 415 voltcomplete all as specified and directed.
94Supply and fixing in replacement of burnt & unserviceable 3 pole power contactor type ML-3,40 Amps, 415 volts ,50 hz coil voltage 415 volt complete all as specified and directed.
95Supply and fixing in replacement of burnt & unserviceable 3 pole power contactor type ML-2,32 Amps, 415 volts ,50 hz coil voltage 415 voltcomplete all as specified and directed.
96Supply and fixing in replacement of burnt &unserviceable moulded case circuit breakers 3 pole 200 Amps TP 415 volts, 50 hz 36 KA complete all as specified and directed
97Supply and fixing in replacement of old burnt & unserviceablemoulded case circuit breakers 3 pole 100 Amps TP 415 volts 25 KA, 50HZ complete all as specified and directed
98S&F and fabrication, welding and fixing ofMS frames made out of MS angle/ flat of any size as required at site for repair/replacement of Sump manhole cover,Stair case steps and all other iron works including covering top with MS Sheet of suitable size and welding with the frame complete all as specified and directed.
99Supplyand fixing in replacement of 15/20 mm bore Bib tap standard of PTMT any colour high pressure screwed for male/ female threaded complete all as specified and directed.
100Supply & fixing in replacement of old unserviceableCI foot valve flanged of following sizes including nuts bolts washers and rubber confirming to IS- 4038 complete all as specified and directed:-
10180mm bore
102100mm bore
103Supply, installation and testing in replacement of oldunserviceable flanged ends Water Meter of following sizes ISI marked woltman type, Class "B" and making good connection with flanged ends, with gasket rubber sheet and nut & boltsfixing in horizontal/inclind/vertical position, complete all as specified and directed:- (Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item).
104100 mm bore
105150 mm bore
106Supply and fixing Fully automatic star-delta (FASD) starter in sheet metal enclosure with voltmeter and amp meter, each motor rating 415 V 3 phase 50 hz for submerisible pump of following size complete all as specified and directed:-
107FASD 7.5 HP
108FASD 10 HP
109FASD 20 HP
110M&L two coat ofpainting of steel and iron surfaces withsynthetic enamel paint as per existing pattern including rubbing down and preparation of steel surface complete all as specified and directed.
111M&L distempering walls with two coat of oil bound distemperincluding washing rubbing down, filling of cracks by 2.0mm thick birlacare putty including necessary scaffolding work etc. complete all as specified and directed
112M&L Distempering walls/Sump with two coat of cement base paint (Snowcem)including Writing letter on Wall/Sump and necessary scaffolding work etc. complete all as specified and directed. (Note:- Cost of letter writings as directed by EIC shall be deemed included in quoted unit rates).
113M&L preparation of old surfaces of LT steel tubular poles of any size and type with bracket clamps etc and painting with two coats of Aluminium paint upto 6 mtr long and exposed surface of Pole yellow and black paint in strips alternative 30 cm wide ipto 1.5 mtr from ground level including marking of pole No"s with paint complete all as specified and directed.
114M&L for re-painting of LT Panels/feeder pillars with two coats of super enamal paint over a coat of red-oxide with sparygun including writing on feeder pillar in appropriate size of letters complete all as specified and directed. (Note:- Cost of letter writing on feeder LT panel/pillars shall be deemed included in quoted unit rate. Height, length and thickness of letters shall be directed by EIC).
115Labour for dismantling, disconnecting theAir Blower twin lobe positive displacement type of pressure of 0.8Kg/Cm2 and capacity upto 800 Cum/hr includingdisconnecting from chanel frame and electrical panel for repair of Gear Box, refitting of gear box after oiling, greasing, alingment of pump set and re-fixing/ assembling testing to make it functional complete inciuding cleaning of all dirt, dust replacing the Air Filter with similar type and make of New filter etc complete all as specified and directed including transportation to workshop for repair. (Note:- 1. Pressure of AIr blower shall be got verified by EIC and the same shall not be less than 0.8 kg/Cm2) 2. Parts shall be measured and paid under respective item).
116Supply only following parts in the twin lobe positive displacement type and pressure rating upto 0.8Kg/cm2 of of existing make at site:-
117Replacement of Pully V Belt SPB-1800/existing at site
118Ball Bearing 6311/C3
119Roller bearing 3213Aor existing at site
120Set of Gasket of suitable size for the compressorexisting at site
121Gear set of suitable size for the compressorexisting at site
122Oil seal of suitable size for the compressorexisting at site
123Oil level glass of suitable size for the compressorexisting at site
124Suction air filter of suitable size/type for the compressorexisting at site
125Air compressor shaft welding , turning , grindingrequired during overhauling of compressor
126Bearing tapper bush for roller bearing 22213 EK/C3 or of suitable size for the compressor existing at site
127Outer distance bush of suitable size for the compressorexisting at site
128Pressure ring of suitable size for the compressorexisting at site
129Asbestos graphite packing(casing cover) of suitable size for the compressorexisting at site
130Asbestos graphite packing(stuffing box) of suitable size for the compressorexisting at site
131Supply & pouring Compressor Oil in air blower at STPs complete all as specified and directed (Note:- Sealed container of compressure oil of approved make shall be kept on charge and necessary issue and receipt voucher shall be entered in MB).
132Disconnecting electric connections from LT control pannel and starter of Non clogging submersible pump setof any size 3 HP to 12.5 HP and removing the pipe line connections from discharge side and taking out sub pump set alongwith, column pipe from Sewage sump/Well/Tank etc with the help of chainpullyincluding transportion to wksp for repair includingreplacement of rusted nuts bolts. rubber gasket complete all as specified and directed. NOTE:- 1.The quoted rates will include for the charges wherever hydra is required for pulling out the pumps out. 2. The contractor will give a guarntee for 6 months for the proper functioning of the pumps and its allied pipe connections/Electrical connections. 3. Burn out/Defective Non clogging pumps/Submercible pumps will be open at site for the defects and material required for replacement in writing to Engr-in-Charge.
133Labour for opening thenon clogging sub pump set, repairing, rewinding and assembling the pump set including insulating material of any size 3HP to 12.5 HP capacity complete all as specified and directed by Engr-in-charge. (Note:- Copper winding wire and other spare part required for repairing will be measured and paid under relevant item as supply only)
134Supply only copper rewinding wire of exsting gauge for non clogging pump sets/ submersible pump Sets/ Induction motors complete all as specified and directed
135Supply only of following spare for non clogging sub Pump set cap 3 HP to 12.5 HP:-
136SS roter sleeve of existing at site
137SS roter shaft ASS 410or of existing at site
138Water seal of existing at site as per pump design
139CI Lower Housing chamber of existing at site
140CI upper housing chamber of existing at site
141Connetion plate of existing at site
142Remetaling of rotor & turning/grinding
143Gun Metal suction ring of existing at site
144Gun Metal Impeller of existing at site
145Stainless Steel stud with nutof existing at site
146Impeller nut as per existing at site
147Impeller key asper existing at site
148Jointing of submersible cable as per existing at site.
149CI suction chamber perfectly suitable as per existing at site
150Repairing of stamping of stator
151Mechanical seal set upper and lower
152Jointing of cable kit without float switch
153Jointing of cable kit with float switch
154CI suction plate as per existing at site
155O ring set as per existing at site
156Insulation kit as per sample
157Ball bearing 6306ZZ
158Roller Bearing 3308
159Roller Bearing NU 305
160Temperature sensor as perexisting at site
161Moisture sensor as per existing at site
162M&L painting of submersible pump set with one coat of red oxide primer and two coat of synthetic enamel paint after preparation of steel surface complete all as specified and directed.
163Labour for dismantling, disconnecting the centrifugal/sewage pump set from foundation and fixing after repairing rewinding and assembling the pump set including insulating material of any size, testing and lowering complete up to upto 20 HP complete all as specified and directed including transportation to workshop for repair complete all as specified and directed by EIC. (Note :- Rewinding and spare parts will be measured and paid seperately under respective items).
164Supply only of the following items of centrifugal/sewage pumps of capacity upto 20 HP:-
165Impeller CI/SS as per existing at site
166Pump shaftSS AISI410 or as per existing at site
167Mechanical seal for pump shaft AISI-410or as per existing at site
168Wear ringas per existing at site
169Gland CI as per existing at site
170Ball bearing 6307ZZ
171Bearing housing NDE as per existing at site
172Shaft Sleeve SS as per existing at site
173Impeller nut as per existing at site
174lock nut as per existing at site
175Gland packing suitable forexisting pump as per mfg recommendation
176Set of O rings as per existing at site
177Liquid deflector as per existing at site
178Gland Eye Bolt with nut SS as per existing at site
179Impeller Key as per existing at site
180Oil seal as per existing at site
181Mechanical seal for support plate as per existing at site
182Bent plug as per existing at site
183Set of gasket as per existing at site
184Support foot as per existing at site
185Lantern ring as per existing at site
186coupling Key CS as per existing at site
187Labour for opening the electric induction motor of capacity upto 20 HP including taking down/out the burnt winding wire, cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge, weight etc. including all other insulating material to make it functionalcomplete all as specified and as directed . (Note:- Copper winding wire of approprioate guage will be measured and paid separately)
188M&L Cleaning of following Capacity STP sewage and removing of settle Down Sewage Sludge cum mud of Bar Screen Chamber pit, Oil & Grease trap tank, unit chamber, equalisation tank, MBBR-1, MBBR-2 Tank, SBT Tank,Tube Settler tank, Filter feed tank, Treated water tank. including cleaning after taking down of choked MS pipes, SS riser pipes, air diffusers in equalisation tank,tube settler and MBBR tanks and refixing the same and including providing with test report of treated water from Govt. approved lab or National authorised lab or other lab approved by GE before completion of cleaning and well functioning of STP as directed by EIC :- Note : - (a) Cleaning Inner surface of tank complete by scraping with steel wire brush and removing mud and sludge collected inside the tank manually and deposit where directed. (b) Washing with clean water and bleaching powder complete tank internally and Removal of left out sludge if any at site and deposit where directed. (c) Branch/tree bushes alongwith STP shall be cleared as directed by EIC.
189STP 250 KLD To 300 KLD
190630 KLD To 800 KLD
191M&L SS Air gridsystem in equalization tank for providing aeration in tank using SS-304 tubing and for air outlet shower rose and ss strainer complete & testing including removing old pipes of any type/size complete all as specified and directed.
192M&L SS-304 Air grid System in MBBR Tanks for providing aeration in MBBR Tanks using SS tubing and for Air outlet shower rose and ss strainer compelte and testing incluidng removing old pipes (if existing) of any type/size complete all as specififed and directed. -
193Supply & fixing heat resistance, weather proof HDPE Fabric Solid STP shade net for covering of tanks complete with fixing arrangement arround the tank complete all as specified and directed.
194Supply & pouring MBBR/FABPVC media model PP22 effective specific surface area 400m2/cum of height 15mm and dia of 22mm complete all as specified and directed.
195Material and labour for Tube Settler modules made of PVCincluding dismantling and taking out the old damaged tube settler media complete all as specified and as directed.
196Supply and pouring of quartz silica sand of 32 -64 grade media size complete all as specified and directed..
197Supply and pouring of quartz silica sand of 16 - 32 grade media size complete all as specified and directed..
198Supply and pouring of quartz silica sand of 8 - 16 grade media size complete all as specified and directed..
199Supply and pouring of quartz silica sand of 4 - 8grade media size complete all as specified and directed..
200Material and labour for activated carbon IV1000 complete all as specified and directed.
201NOTE- for item no. 63 to 69 the cost for removal the old material from site to the location as directed shell deemed to be included in respective item. No extra amount shall be paid.
202Supply and fixing in replacement, installation commissioning and testing DOSING PUMP high pressure, single head, gear motored adjustable dosing pump with accessories including lead tubing, connecting nuts, injection check valve ,clay weight , and ferrules and including fixing dosing system consisting of 200 litre PE/FRP Tank with PE/FRP Lid & level gauge along with agitator with shaft & blade in SS 316 (FRP/Epoxy coated)/plastic, mounted on tank Lid will have port hole for pouring bleaching powder and water when necessary. Lid will also have provision for mounting Dosing pump on the lid/wall complete all as specified and directed.
203Supplying , laying , jointing, welding & testing MS Pipe (Heavy duty class"C") of following size bore laid in trenches or laying on floors or laying on wall in any position including all fitting complete all as specified and directed:- Note:- (i) MS/SS Flanges and Flange joints complete with jointing materials shall also be Incuded in this item.
20450 mm bore
20580 mm bore
206100 mm bore
207125 mm bore
208150 mm bore
209Supply, fixing, jointing & testing in replacement of unserviceable cast iron sluice valve of following size as under ISI marked, flanged end drilled pressure rating PN 1.6 PD short body,conforming to IS 14846-2000, having stainless steel spindle with cast iron operational wheel at top including taking out unserviceable sluice valve complete all as specified and directed. (Note- Flanged joints complete with jointing material shall deemend to be included in the unit rate of this item)
210100 mm bore
211150 mm bore
212Supply, Installation and testing in replacement of unserviceable Flanged ends water meter of following size ISI marked woltman type, class B of following sizes and making good connection with flanged ends, with gasket rubber sheet and nuts & bolts fixing in horizontal/inclined/vertical position, including taking out unserviseable water meter complete all as specified and directed. (Note- Flange Joints Including Jointing material shall deemed to be included in the unit rate of this item)
213100 mm bore
214150 mm bore
215M&L Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 3.5 m below normal ground level) with top edge of earth plate not less than 2.5mbelow normal ground level, connected to galvanized iron strip 32X6 mm by means of electric arc welding of galvanised iron or steel as shown in electricalplate No 3 of SSR Part I, connected to earth test point and the equipment on the other side complete all as specified, including testing and commissioning complete all as specified and directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40mm bore GI pipe light grade etc. (b)The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI earthing and protection pipe upto 7.5 meter beyond the earth plates electrode.
216Supply and fixing in replacement Pressure Gauge as required at site complete all as specified and directed by Engr-in-Charge
217Excavation in trenches not exc. 1.5 mtr wideand not exc 1.5 mtr deep for pipe line in soft/loose soil, getting out and levelling of bottom surface as required complete all as specified anddirected
218Returning filling in , including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified anddirected
219Removing excavated material from site to a distance not exc 50 m away and depositing where directed at a level not exc 1.5 meters above the starting point complete all as specified and directed
220M&L for laying of Burnt bricks sub class "B" old size laid in trenches with equal to length of bricks across the cable for cable protection complete all as specified and directed
221Supply and spread clean dry Yamuna river sand to required width at bottom and top for cable cushioning of thickness 8cm below cable and 15cm above cable punned to 10cm thickness complete all as specified and directed. (Note :- Punned depth of sand shall be measured and paid.)
222Supply and fixing, install, test and commissioning of LT Feeder pillar box outdoor type totally enclosed with front and rear opening hinged doors with canopysloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15mm thick CRCA sheet, factory made (CPRI approved manufacturer) powder coated painted as approved colour, copper bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 350 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lampRYB, complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going LT cables as per required sizes,PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers etc., including dismantling exisiting unserviceable LT panel complete. all as specified and directedaccomodate the following items (Location- Baird Place STP) (a) Incoming MCCB"s - 250A 36 KA 4 Pole - 01 Nos (b) Outgoing MCCB"s - 200A 25 KA 4 Pole - 01 Nos (c) Outgoing MCCB - 100A 16 KA 4 Pole - 04 Nos (d) Outgoing MCCB - 63A 10 KA 3 Pole - 01 Nos Note :- (i) Contractor shall be got approval of Accepting Officer for panel drawing before fabrication work.
223All as in item No 82here-in-before but comprising of the following: (Location- Baird Place STP) (a) Incoming MCCB - 200A 36 KA 4 Pole -01 Nos (b) ML-3 FASD - 03 Nos for outgoing (c) ML-2 DOL - 02 Nos for Outgoing (d) 100 amps 3 Phase Auto Phase sequence corrector - 01 Nos (e) Thermal Overload Relay- Outgoing - 05 Nos
224All as in item No 82here-in-before but comprising of the following: (Location- Baird Place STP) (a) 160A 36 KA 4 Pole- Incoming MCCB - 01 Nos (b) ML-2 FASD - 04 Nos for outgoing (c) 63 amps 3 Phase Auto Phase sequence corrector - 01 Nos (d) Thermal Overload Relay- Outgoing - 04 Nos
225S&F in renewal on load change over switch open execution of capacity 250 Amps , 4 pole , 415 volt , 50 Hz fixed on wall including taking out old existing unserviceable changeover from wall complete all as specified and directed.
226S&F Jointing and testing of cast Iron Non return valve of following sizes, without bypass arrangement,confirming to IS 5312 flanged ends, Pressure rating PN 1.0 complete including taking out unserviceable NRV. Complete all as specified and directed Note: Flanged Joints complete with Jointing materials shall deemend to be included in the unit rate of this item
227100 mm bore
228150 mm bore
229Supply, Laying, Jointing, Testing and commmissioning of DI Pipe of following size suitable for Sewage Plant IS-7186-2011, K-7 with spigot and socket ends centrifugally casted, including all fitting such as Bend, Tee,Tyton joints etc as require at site, laid in trenches complete all as specified and directed :-
230100 mm bore
231150 mm bore
232Supply and Fixing in replacement of Butterfly Valve(Wafer Type) P.N 2.5, lever operated of Following Size complete all as specified and directed
23380 mm bore
234100 mmbore
235125 mm bore
236150 mmbore
237Note:- Sch of credit amount of Rs.201148.00/- shall be deducted from total quoted BOQ Amount when work acceptance letter issued.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail