Tender For Repair / Maint Of Lt Over Head Line, Lt Underground Cable, Apfc Panel And Connected Items At Klp And Map Area At Suratgarh Mil Stn, suratgarh-Rajasthan

Military Engineer Services-MES has published Tender For Repair / Maint Of Lt Over Head Line, Lt Underground Cable, Apfc Panel And Connected Items At Klp And Map Area At Suratgarh Mil Stn. Submission Date for this Tender is 15-07-2023. Overhead Line Tenders in suratgarh Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

38247063
Corrigendum : Tender For Repair / Maint Of Lt Over Head Line, Lt Underground Cable, Apfc Panel And Connected Items At Klp And Map Area At Suratgarh Mil Stn
Open Tender
Indian
Rajasthan
suratgarh
15-07-2023

Tender Details

Repair / Maint Of Lt Over Head Line, Lt Underground Cable, Apfc Panel And Connected Items At Klp And Map Area At Suratgarh Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Jun-2023 Corrigendum BOQ 08-07-2023
2 08-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 96000.0 /-
Tender Value
INR 48 Lakhs /-

BOQ Items

Name of Work : Repair / Maint of LT over head line, LT underground cable, APFC panel and connected items at KLP and MAP area at Suratgarh Mil Stn
Sl. No. Item Description
1Dismantling existing unserviceable Aluminium conductors, steel reinforced (ACSR conductor) from overhead lines on LT poles, of any type and any size complete all as specified and as directed by Engineer-in-charge
2Disconnecting and re-stretching ACSR conductor of any size and re-fixing with and including new 2mm dia aluminum binding wire complete all as specified. Note :- (i) The rate quoted by the contractor shall deemed to be included for cutting / trimming of tree branches touching / approaching the LT over lines upto 3 metre width on each side with hacksaw / axe to clear the LT line including disposal of trimmed branches 100 metre away inside the cantonment area & cleaning site as directed by Engineer-in-charge. (ii) Length of each conductor shall be measured as one length.
3Supplying, fixing & stretching aluminium conductor steel, reinforced (ACSR) of any size fixed on LT poles fixed on insulators and binding with & including 2 mm binding wire complete all as specified and directed by Engineer-in-Charge. Notes: - (i) The ACSR conductors shall be conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also be deemed to include for supply and fixing of binding wire, aluminum tapes etc. which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size multiplied by length of span and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS.
4S&F in replacement shackle type insulators, vitreous porcelain white, brown or green for working pressure 1100 volts grade of 100 mm height and 115 mm dia including galvanized mild steel straps of 31mm x 5mm size,14mm dia insulator bolts, washers and nuts complete all as specified and directed by Engineer-in-Charge.
5S&F in replacement pin type insulator of size 100mm height, 65 mm diaporcelain, vitreous white, brown or green insulator suitable for 1100 volts grade including one galvanized mild steel spindle, two GI washer and one GI nutcomplete all as specified and directed by Engineer-in-Charge.
6S&F in replacement pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and yellow colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note:PCC for foundation and earth work shall be measured and paid for separately.
7Disconnecting over head conductors and insulators any Nos on existing damaged steel tubular swaged LT poles, dismantling MS work such as cross arms /clamps/hooks etc, stay and street light (where exists), excavating and taking out damaged pole making good hole to receive new pole and S&F in same position new steel tubular swaged pole 09 meter long type 410SP-31, re-fixing the MS work cross arms/clamps/hooks etc and insulators retrieved from dismantling and re-jointingthe conductors with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping and applying two coats of aluminium paint to remaining portion of pole, over cross arms, brackets, bracings, clamps, hooks etc and marking pole number complete all as specified and as directed by Engineer-in-charge. Note :- Cost of PCC, excavation and coping shall be deemed to be include in the quoted rate.
8M&L for painting on steel tubular poles 9metre long including attachments (cross arms, clamps GI pipes etc) complete with one coat of aluminium paint after preparation of steel surfaces and black & yellow strips 30cm each upto 1.5 metre height from top of PCC foundation block or PCC coping including numbering of poles with synthetic enamel paint (Black) in 80mm high letters over 150mmx230mm yellow base complete all as specified and directed by Engineer-in-charge.
9M&L for preparation of old painted surfaces of PCC pole and applyingtwo coats of synthetic enamel paint in black and yellow colour in alternate strips of 30 cm each upto 1.50 metre height from top of PCC coping and applying two coat of aluminum paint over cross arms, brackets, bracings, clamps, hooks etc. and marking pole number with white synthetic enamel paint in 80mm high letters, over black synthetic enamel paint base of size 20cm x 20cmincluding applying two coats of white wash to coping of polesall as specified and directed by Engineer-in-Charge. Note :-Pole number shall be marked with white enamel paint over a base of size 20cm x 20cm prepared with two coats of blackenamel paint on pole surfaces.
10M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etcincluding weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
11M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of poles, filling & mass concrete including necessary form work completeall as specified and directed by Engineer-in-charge .
12M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation for stays & mass concrete including necessary form work and fair finishing completeall as specified and directed by Engineer-in-charge
13Suppyling, installing, testing in replacement and commissioning of factory made outdoor type bus bar chamber having MCCB 160 Amps, 4 pole, 415 volts, 3 phase, 4 wire, 50 Hz, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the 160 Amps aluminium bus bar fixed horizontally in staggred manner minimum length 450mm, 3 phases and neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty DMC insulators duly connected with 160 Amps MCCB including provision for taking out incoming and outgoing cable detacheable plate at bottom for cable entry and making six Nos hole in each bus bar including with bottom frame made out of angle iron 50mm x 50mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces groutedin PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm complete all as specified and directed by Engineer-in-Charge. Note :- (i) Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account. (ii) All cables to be connected with busbar will be properly thimbles.
14All as per item No 13 above but MCCB 100 Amps, 4 pole, 415 volts and 100 Amps aluminium bus bar
15M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thickpacked layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth leadby means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0cover with 40mm x 40mm x 3mm MS angle iron frame, excavation & earth work completeall as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old earthing complete all as specified and directed by Engineer-in-charge. Notes :-(i) Cost of GI strip upto 7.5m is included in this item. (ii) PCC 1:2:4, Excavation, earthwork is included in the quoted rate of this item. (iii) Cost of GI tubing upto 7.5m is included in the quoted rate of this item. (iv) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (v) Minimum weight of reinforcement for RCC cover shall be 1 KG.
16Laying, jointing, commissioning and testing in replacement XLPEinsulated screened PVC bedded, armoured,heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 185 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i)Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions. (iii) Cable required for laying shall be issued under Schedule "B" free for fixing only.
17Supplying, laying, jointing, commissioning and testing XLPEinsulated screened PVC bedded, armoured,heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 240 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc including taking down old unserviceable cable complete all as specified and directed by Engineer-in-charge. Notes :- (i)Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
18All as per item No 17 above but cable of cross sectional area 120 sq mm 3.5 core
19All as per item No 17 above but cable of cross sectional area 95 sq mm 3.5 core
20All as per item No 17 above but cable of cross sectional area 70 sq mm 3.5 core
21All as per item No 17 above but cable of cross sectional area 50 sq mm 3.5 core
22All as per item No 17 above but cable of cross sectional area 35 sq mm 3.5 core
23Supplying, laying, jointing, comissioning and testing of PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 sqmm 4 core confirming to IS : 1554 (Part-I 1988) laid in tenches along polesthrough pipe etc including taking down old unserviceable cable complete all as specified & as directed by Engineer –in-charge. Notes :- (i)Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
24All as per item No 23 above but cable of cross sectional area 16 sq mm 4 core
25All as per item No 23 above but cable of cross sectional area 16 sq mm 2 core
26All as per item No 23 above but cable of cross sectional area 10 sq mm 2 core
27Supplying, jointing and testing heat shrinkable typestraight through cable jointing kit, suitable for cable of size 25 to 50 Sqmm, 3.5 core aluminium conductor1100 Volts including making connectionscomplete all as specified and directed by Engineer-in-Charge.
28All as per item No 27 above but suitable for cable of size 70 sqmm to 120 sqmm.
29All as per item No 27 above but suitable for cable of size 150 sqmm to 185 sqmm.
30All as per item No 27 above but suitable for cable of size 240 sqmm to 300 sqmm.
31Supplying, jointing and testing heat shrinkable type, out door, end termination jointing kit, suitable for cable of size 25 to 50 Sqmm, 3.5 core aluminium conductor1100 Volts including making connectionscomplete all as specified and directed by Engineer-in-Charge.
32All as per item No 31 above but suitable for cable of size 70 sqmm to 120 sqmm.
33All as per item No 31 above but suitable for cable of size 150 sqmm to 185 sqmm.
34All as per item No 31 above but suitable for cable of size 240 sqmm to 300 sqmm.
35Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT / HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the LT / HT line including disposal of trimmed branches100 Metre away inside the cantonment area & clearing site complete all as specified and directed by Engineer-in-Charge. (Approximate length of span 40 to 50 metre) Note:-The contractor shall be responsible to maintain this item of work till the date of completion work. Nothing shall extra be paid on this account.
36Taking out old unserviceable underground LT Cable with standad aluminium conductor 1100 volts grade cross sectional area upto 95 Sqmm 3.5 core form trenches / floor / road / pipe / along poles and relaying in the same location after repair complete all as specified and directed by Engineer-in-Charge. Note : Excavation &earthwork shall be measured and paid seperately under respective items of BOQ.
37All as per item No 36 above but cable of cross sectional area 120 sqmm to 300 sqmm, 3.5 core
38S&F in replacement stay assembly complete with accessories as shown in electrical plate No 1 using stay rod 16 mm dia x 1800mm long, stay bow 14mm dia and stay plate 30 cm x 30 cm x 6 mm including stay wire 8 SWG x 7 strands, loop type insulator with over all dimensions 90x140mm and clearence of hole 25.5mm, stay clamps and painting to exposed surfaces of mild steel work with two coats of aluminum paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. Note : Excavation,earthwork and PCC in foundation shall be measured and paid seperately under respective items of BOQ.
39S&F in replacement cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel confirming to Fe-290 (Gde E-165) including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size complete all as specified and directed by Engr-in-Charge. Note :Exposed steel surface shall be treated with two coats of synthetic enamel paint over a coat of red oxide primer and unexposed surface of steel sections shall be applied onecoat of red oxide primer.
40Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc.in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
41All as per serial item No. 40 here-in-above but depth exc 1.5 mtr & not exc 3mtr
42Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
43Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
44M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
45M & L for brick protection with old size sub class "B" bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
46S&F in replacement Galvanized iron tubing, 100mm bore light grade, ISImarked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp is included in the unit rate of this item. Nothing extra shall be paid on this account.
47All as per item No 46 above but 80mm bore tubing
48All as per item No 46 above but 50mm bore tubing
49All as per item No 46 above but 40mm bore tubing
50M&L for preparation of existing painted surfaces of Panel Board / Feeder Pillar box(indoor / outdoor type), area not exceeding 10 square metre each and applying one coat of synthetic enamel paint after preparation of surfaces on external and internal surfaces of approved tint by using spray machineinclusive of writing SM / MES No / name of feeders etc.(not exceeding of height 5 cm each) including welding of broken panel door, tightening electric connection of switch gears and cleaning of vegetation all around the panels up to one meter from all sides complete all as specified and as directed by Engineer-in-charge.
51S&F in replacement MCCB 4 Pole 63 Amps, thermal magnetic releasehaving, breaking capacity 25 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars,making necessary welding work, metal work for fixing base plate etc and connectionscomplete all as specified and as directed by Engineer-in-Charge.
52All as per item No. 51 here-in-before but MCCB 4 Pole, 100 Amps rating, breaking capacity 25 KA, 415 Volt.
53All as per item No. 51 here-in-before but MCCB 4 Pole, 125 Amps rating, breaking capacity 25 KA, 415 Volt
54All as per item No. 51 here-in-before but MCCB 4 Pole, 160 Amps rating, breaking capacity 36 KA, 415 Volt
55All as per item No. 51 here-in-before but MCCB 4 Pole, 250 Amps rating, breaking capacity 36 KA, 415 Volt
56All as per item No. 51 here-in-before but MCCB 4 Pole, 400 Amps rating, breaking capacity 36 KA, 415 Volt
57All as per item No. 51 here-in-before but MCCB 4 Pole, 630 Amps rating, breaking capacity 50 KA, 415 Volt
58S&F LT Line polypropylene composite phase separator, moulded or bolted type, overall length 640mm, width 25mm, thickness 12mm, suitable for 3-lines wire complete all as specified and as directed by Engineer-in-charge.
59S&F LT Line polypropylene composite phase separator, moulded or bolted type, overall length 940mm, width 25mm, thickness 12mm, suitable for 4-lines wire complete all as specified and as directed by Engineer-in-charge.
60S&F LT Line polypropylene composite phase separator, moulded or bolted type, overall length 1250mm, width 25mm, thickness 12mm, suitable for 5-lines wire complete all as specified and as directed by Engineer-in-charge.
61S&F in replacement MCB, four Pole 63 Amps, having breaking capacity 10 KA, "C" Curve complete all as specified and directed by Engineer-in-Charge.
62S&F in replacement air termination, single pointed aluminium rod 12 mm dia single pointed 300 mm longcomplete all as specified and directed by Engineer -in-Charge.
63S&F in replacement galvanized iron strip of size 32 mm x6mm to be used as down conductor for lighting protection and to arrange ring main circuitfor earth pit complete all as specified and directed by Engineer -in-Charge.
64S&F in replacement Digital type Voltmeter 96mm x 96mm, of range 0-500 volts, class -1 complete all as specified & as directed by Engineer-in-charge
65S&F in replacement Digital type Ammeter 96mm x 96 mm of range 0-200 Amp, single phase, class -1 complete all as specified & as directed by Engineer-in-charge
66S&F in replacement selector switch rotary type, flush button, 3 way position in one for voltmeter or Ampmeter of any range as per existing complete all as specified & as directed by Engineer-in-charge
67S&F in replacement Phase indicator lamp assembly LED type complete with indicator lampincluding making connections with 2.5 Sq mm copper conductor PVC insulated and PVC sheathed single core cable complete all as specified and as directed by Engineer-in-charge.
68S&F in replacement 100mm size mild steel butt hinges cold rolled medium weight complete all as specified & directed by Engineer-in-Charge.
69S&F in replacement 250mm long mild steel sliding door bolts clip type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in-Charge.
70S&F in replacement heavy duty TPN bus bar chamber 100 Amps, 4 way fixed with hinges and locking arrangements, wall mounting type and arrangements for 4 Nos incoming / outgoing connections in each bus bar fixed on wall complete all as specified & directed by Engineer-in-Charge. Make :- Havells Cat Part No IHBC010004 / Legrand / L&T or equivalent in makes mentioned in Appendix "A" here-in-after.
71M&L for fixing MS sheet 2mm thick to existing LT panels / feeder pillar box including necessary straightening / correcting the distorted parts, cuttings, welding / riveting, drilling bend to shape as required, welding of hinges, sliding door bolts, locking arrangement, nut, bolts, washers etc and appying two coats of synthetic enamedled paint over a coat of red oxide primer to match with the existing surfaces comlepte including butt hinges sliding door bolts and taping , thimbling disconnecting all incoming and outgoing complete all as specified and as directed by Engineer-in-charge. Note :- Supply only butt hinges and sliding door bolts shall be measured and paid seperately under respective items of BOQ.
72S&F in repair of ACB 4 pole, 415 volts, 630 Amps 50 KA manually draw out type with microprocessor relay comprising with earth fault, over load and short circuit complete all as specified and as directed by Engineer in charge.
73Inspection/checking of APFC panel 3 phase, 440 voltage 50 Hz AC supply system to improve power factor 0.80 to 0.98 automatic step wise switched capacitor panel to make it serviceable with the help of connecting relays, capacitors, contactors, MCB"s, CT"s etc and rectifying the defects, replacement of unserviceable part as required at site and cleaning of AMF panel as detecting during inspection or pointed out by users/department and carry outmaintenance complete all as specified as directed by Engineer-in-charge. Note:- Required spare parts required shall be measured and paid for separately under respective items of BOQ as supply only..
74Supply only in replacement of AIPFC micro processor based relay 4 Stage PFC CONTROLLER-BR-4904-04 ST RELAY 230V complete all as specified and as directed by Engineer in charge.. Make - L & T /GE / EPCOS / Siemens / Crompton or equivalent in makes mentioned in Appendix "A" here-in-after.
75Supply only in replacement of AIPFC micro processor based relay 8 Stage PFC CONTROLLER-BR-4000-08 ST RELAY 230V complete all as specified and as directed by Engineer in charge.. Make - L & T /GE / EPCOS / Siemens / Crompton or equivalent in makes mentioned in Appendix "A" here-in-after.
76Supply only in replacement of AIPFC micro processor based relay 12 Stage BR6000 SERIES 12 STP RELAY 230V complete all as specified and as directed by Engineer in charge.. Make - L & T /GE / EPCOS / Siemens / Crompton or equivalent in makes mentioned in Appendix "A" here-in-after.
77Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 1 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32447A4012B 40 / GE/L& T / Siemens / Crompton or equivalent in makes mentioned in Appendix "A" here-in-after.
78Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 2 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32447A4022B 40 / GE / L& T / Siemens / Crompton or equivalent in makes mentioned in Appendix "A" here-in-after.
79Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 3 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32448A4032B 40 / GE/L& T / Siemens /Crompton or equivalent in makes mentioned in Appendix "A" here-in-after.
80Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 4 KVAR complete all as specified and as directed by Engineer in charge. Make :- Epcos Cat part- B32448A4042B 40 / GE / L& T / Siemens /Crompton or equivalent in makes mentioned in Appendix "A" here-in-after.
81Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 5 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32448A4052B 40 / GE / L& T / Siemens /Crompton or equivalent in makes mentioned in Appendix "A" here-in-after.
82Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 10 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32448A4102B 40 / GE / L& T / Siemens / Crompton or equivalent in makes mentioned in Appendix "A" here-in-after.
83Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 12.5 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part-B32448A4122B540 / GE / L& T / Siemens / Crompton or equivalent in makes mentioned in Appendix "A" here-in-after.
84Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 15 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32448A4122B540 / GE / L& T / Siemens /Crompton or equivalent in makes mentioned in Appendix "A" here-in-after.
85S&F in repair of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 25 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32448A4252B 40 / GE / L& T / Siemens /Crompton / Epcos or equivalent in makes mentioned in Appendix "A" here-in-after.
86Supply only in replacement of Capacitor duty contactors 3 Phase suitable up to 10 KVAR cap Duty cont 1 NO1NC240V complete all as specified and as directed by Engineer in charge.. Make - EPCOS Cat Part No B44066S1011C240N 1 or equivalent in makes mentioned in Appendix "A" here-in-after.
87Supply only in replacement of Capacitor duty contactors 3 Phase suitable up to 16 KVAR cap Duty cont 1 NO1NC240V complete all as specified and as directed by Engineer in charge. Make - EPCOS Cat Part No B44066S1611C240N 1 or equivalent in makes mentioned in Appendix "A" here-in-after.
88Supply only in replacement of Capacitor duty contactors 3 Phase suitable up to 25 KVAR cap Duty cont 1 NO1NC240V complete all as specified and as directed by Engineer in charge.. Make - EPCOS Cat Part No B44066S2511C240N 1 or equivalent in makes mentioned in Appendix "A" here-in-after.
89Supply only in replacement of current transformer of ratio 100/5, 5 VA with accuracy class 1.0 including connection with 2.5 sqmm twin core PVC cable complete all as specified and as directed by Engineer in charge.
90Supply only in replacement of current transformer of ratio 200/5, 10 VA with accuracy class 1.0 including connection with 2.5 sqmm twin core PVC cable complete all as specified and as directed by Engineer in charge.
91S&F in replacement MCB 32 Amps, 3 pole, C curve, 10 KA complete all as specified and as directed by Engineer in charge.
92S&F in replacement MCB 40 Amps, 3 pole, C curve, 10 KA complete all as specified and as directed by Engineer in charge.. ---------------------------------------------------------------------------- Note :-A sum of Rs. 428753/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 22 & 23 (Schedule of Credit) of Tender documents.