Irrigation And Public Health Department has published Tender For Source Strengthening And Rehabilitation Of Various Water Supply Schemes Under Js Sub Division Mandap In Tehsil Dharampur Distt. Mandi Hp Under Jjm. Submission Date for this Tender is 26-06-2023. Pump Supply Tenders in Mandi Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 22-Jun-2023 | corrigendum | Other | 26-06-2023 |
Sl. No. | Item Description |
1 | Excavation in foundation, trenches etc. in all kinds of soil such as pick work, jumper work, blasting work in soft / hard rock, chiselling in soft / hard including wedging out of a rock where blasting is prohibited and stacking the excavated earth up to all lifts, stacking the excavated soil up to all lead clear from the edge of excavation and then returniing the stacked soil in 15 centimeters layers when required in to plinths, sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed within all leads & lifts as perentire satisfaction of Engineer- in- charge. |
2 | Including dewatering |
3 | Excluding dewatering |
4 | Steel work in single section, fixed without connecting plates including cutting, hoisting & fixing in position and applying a coat of primer or red lead paint in R.S. Joists, Channel, angles and tees etc. Complete within all leads & lifts as per entire satisfaction of Engineer in charge. |
5 | Providing and laying cement concrete 1:5:10 (1 cement :5 sand : 10 graded stone aggregate 40mm nominal size)curing complete excluding cost of form work in foundation and plinth as per direction and to the entire satisfaction of Engineer-in-Charge. |
6 | Providing and laying cement concrete 1:4:8 (1 cement : 4 sand : 8 graded stone aggregate 40 mm nominal size ) and curing complete excluding cost of form work in foundation and plinth within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
7 | Providing and laying cement concrete 1:3:6 (1 cement: 3 sand: 6 graded crushed stone agg. 40mm nominal size) and curing complete excluding cost of form work in:- |
8 | Foundation and plinth upto all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge. |
9 | Providing and laying cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size)and curing complete excluding cost of form work in:- |
10 | Foundation and plinth upto all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge. |
11 | Suspended floors, roofs, landing and shelves and their support, balconies, beams, girders, bressumers and cantilever upto all floor level within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
12 | Providing & Laying cement concrete work Grade M30 (Design Mix) but not leaner than 1 : 1.5 : 3 (1 cement : 1.5 sand : 3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:- |
13 | Foundation and plinth upto all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge. |
14 | Walls any thicknessbut not less than 0.1m thickness including attached pillaster buttresses, plinth and string courses from top of foundation upto two level all floor level as per direction and to the entire satisfaction of Engineer-in-Charge. |
15 | Lintels,beams, girders, bressumers and cantilevers upto floor two level within all lead and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. |
16 | Column, pillar, posts and struts upto floor two level as per direction and to the entire satisfaction of Engineer-in-charge upto all lead and lifts. |
17 | Suspended floors, roofs, landing and shelves and their support, balconies, beams, girders, bressumers and cantilever upto all floor level within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
18 | Archesupto floor two level in all leads and lifts as per direction and to the entiresatisfaction of Engineer-in-charge. |
19 | Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for insitu- reinforcement concrete and plain concrete work in:- |
20 | Foundation footing bases of columns etc and mass concretecomplete within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. |
21 | Flat surfaces such as soffits of suspended floors, roofs, landings and the like, Floors etc. up to any thicknesscomplete within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. |
22 | Vertical surfacessuch as wall (any thickness) partitions and the like including attached pillasters, buttresses plinth and string courses and the likecomplete within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. |
23 | Columns, pillars, post and struts, Square, rectangular or polygonal in plancomplete within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. |
24 | Beam, cantilever, girders and lintels, Sides and soffits of beam, beam haunching, cantilever, bressumers and lintels not exceeding 1 mtr. In depth in all heights from floor complete within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. |
25 | Edges of slabs and breaks in floors & walls under 20 cms. Wide. |
26 | Providing form work of ordinary timber plankings so as to give a rough finish including centring, shuttering, strutting & propping etc. height of propping & centring below supporting floor to ceilling not exceeding 4 mts. And removal of the same for insitu-reinforced concrete and plain concrete work in : |
27 | Arches beyond 6.00 mtrs span as per direction and to the entire satisfaction of Engineer-in-charge.. |
28 | Providing Tor steel reinforcement for RCC work including bending binding and placing in position complete upto all floor level within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
29 | Steel work welded in builtup section, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead painting grating, framed guard bars ladders, railing brackets and similar works as per direction of Engineer-in-Charge upto all lead and lift. |
30 | Providing RCC work smooth finishing of the exposed surface with cement mortar 1:3 (1 cement :3 sand) and curing complete in all lead and lifts as per direction and to the entire satisfaction of the Engineer-in-Charge. |
31 | Providing and laying no fine cement concrete 1:4 (1 cement: 4graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work in. Cement Mortar 1:6 |
32 | Providing and fixing precast concrete manhole cover and frame, conforming to IS 12692-2002, 560mm dia completeas per direction and to the entire satisfaction of Engineer-in-Charge. |
33 | Brick work using common burunt clay building bricks in super structure in cement mortor 1:6 (1 cement : 6 sand) (2nd class brick) within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
34 | Brick work using common burunt clay building bricks in super structure above plinth level to up to floor two level in cement mortor 1:4 (1 cement : 4 sand) (2nd class brick) within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
35 | Half brick masonry in common burnt clay 2nd class building bricks in super structure above plinth level upto floor two level in cement mortar 1:4 (1 cement :4 sand) as per direction and to the entire satisfaction of Engineer-in-Charge upto all lead and lifts. |
36 | Providing and fixing pressed steel doors frames manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jump lock jamb, beed and if required angle threshold of mild steel angle of section 50 X 25 mm or base ties of 1.25 mm pressed mild steel welded or regidly fixed together by mechanical mean, adjustable lugs with split and tails to Each jamb including steel but things 2.5 mm thick with guards look strike plte and shock ans specified and applying a coat of approved steelprimer after pretreatment of the surface as directed by Engineer-in Chief ( Profile - A) |
37 | Providing and Fixing panneled glazed or panelled and glazed shutters for doors, windows and clerestory windows,including black enamelled iron butt hinges with necessary screws. 40 mm thick. (2nd class deodar wood) within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
38 | Prov. & fixing wire gauge shutters using galvanized MS wire gauge of IS gauge designation 85 G. with wire of dia. 0.56 mm for doors,windows & clerestrey windows including bright finished black enameled iron hinges with necessary screws. |
39 | 15mm thick cement plaster in single coat on rough sides of brick/concrete/stone walls for interior plastering upto floor two level includong arises, internal round angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth in Cement mortar 1:6 (1 cement:6 sand) |
40 | 15mm cement plaster in single coat on rough sides of brick/concrete/stone walls for interior plastering upto floor two level includong arises, internal round angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth in Cement mortar 1:4 (1 cement:4 sand) |
41 | 15mm cement plaster in single coat on rough sides of brick/concrete/stone walls for interior plastering upto floor two level includong arises, internal round angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:3 (1 cement:3 sand) |
42 | Pointing on brick masonry in cement mortor 1:3 (1 cement:3 sand) RULED |
43 | 6 mm Cement plaster to ceiling in cement mortar 1:4 (1 cement: 4 sand) |
44 | Beam ISMB 450 for hoisting chain pully i/c chain pulley arrangement |
45 | Provision for providing and installation of yard lights/ Flood lights around the intake works |
46 | Providing and fixing steel bar cage for fastening of pump with piers of 300 mm dia of mesh size 50 mm x 50 mm, 16 mm square steel bars. |
47 | Providing & fixing 0.60 mm Thick pre-painted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5 microns primer coating i/c fixing with prepainted iron J or L-hooks bolts & nuts 6 mm dia with prepaintedlimpet and rubber washer complete with all accessories as required as per direction and to the entire satisfaciton ofEngineer-in-charge. |
48 | Providing and fixing Chain pully system for 2 Nos. pump set with steel rope of 15 mtrs length each ISI marked of reputed make complete and testing on 5 to 7.5 tonne load as required as per direction and to the entire satisfaciton ofEngineer-in-charge. |
49 | Cement concrets flooring 1:2:4 (1 cement :2 sand :4 graded stone aggregate 20mm nominal size) laid in one layer finished with a floating coat of neat cement (40 mmthick) as per direction and to the entire satisfaciton ofEngineer-in-charge upto all lead and lift. |
50 | Providing and fixing bright finished brass sliding door bolts with nuts and screws etc. complete. as per the direction and to the entire satisfaction of Engineer-in-charge. |
51 | 250 x 10 mm |
52 | Providing and fixing bright finished brass tower bolt (barrel type) with necessary nuts, bolts and screws etc. as per the direction and to the entire satisfaction of Engineer-in-charge . |
53 | 250 x 10 mm |
54 | Providing and fixing bright finished brass handles with necessary nuts, bolts and screws etc. as per the direction and to the entire satisfaction of Engineer-in-charge . |
55 | 125 mm |
56 | Providing and fixing of MS round bars (16 mm) in windows and ventilators. |
57 | Kota stone slab flooring 20 mm (average) thick base of cement mortor 1:4 (1 cement :4 sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab. including rubbing and polishing complete 40 mm Thick as per direction and to the entire satisfaction of Engineer-in-Charge. |
58 | Providing 40x3 mm iron hold fast 40 cm long including Fixing to frame with 10 cm da bolts nuts and wooden pluges and embencing in C.C. block 30x10x15 cm 1:3:6 ( 1 cement:3 sand: 6 gradedstoneaggregate 20 mmnominal size) within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
59 | Providing and fixing M.S. fan clamp (Type-Iof 16mm dial M.S. Bar bent to shape with hooked ends in RCC. Slab during laying including painting the exposed portion of loop all as per standard design complete. |
60 | White washing with lime on undecorated wall surface two coats to give an even shade I/c throughly brooming the surface to remove all dirt, dust, mortar, dust and other foreign matter as per direction and to the entire satisfaction of Engineer-in-charge. |
61 | Applying priming coat over new wood and wood based surfaces after and inciuding preparing the suface be thoroughly cleaning oil grease dirt and othr foreign sand papering and knotting Readymixed paint brushing wood primer pink complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge. |
62 | Painting two coats (excluding priming coat) on new wood and wood based surfaces with ready mixed paintto give an even shade including cleaningthe surface of dirt, dust and other foreign matters sand papering and stopping with enamel paint other than white complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge. |
63 | Painting two coat (excluding Priming coat ) on new steel and other metal surface with ready mixed paint brushing to give an even shade I/c cleaning of all dirt dust and other foreign matter with ready mix paint as per direction and to the entire satisfaciton of Engineer-in-charge upto all lead and lifts. |
64 | Wall painting (two coats) with acrylic emulsion paint of approved brand and manufacture for interior grade on undecorated concrete/stone/plastered wall surfaces to give an even shade including t horoughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth including applying of putty a required for metling the surface |
65 | Applying two coat of woodpreservative on new wood based surfaceafter and including preparing the surface by thoroughly cleaning dirt dust and other foreign matter. |
66 | Providing plinth protection 50mm thick in cement concrete 1:3:6 (1 Cement : 3 Sand : 6 Graded stone aggregated 20mm nominal size within all leads and lifts, including all incidental charges |
67 | Providing under layer for plinth protection of 75mm thick (unconsolidated) bed dry brick/stone aggregated 40mm nominal size will rammed and consolidated and grouted with fine sand including preparation of ground as per direction and to the entire satisfaction of Engineer-in-charge |
68 | Laying of 125 mm dia (medium class) GMS pipe The laying of pipe should confirm to IS 5822-1994 (The earth work in trenches to be measured and paid for seperately). The work shall be done as per entire satisfaction of Engineer-in Charge with in all leads and lifts. (Labour Rate) |
69 | Laying, jointing & testing of G.I pipe of following dia (Following Class)for outlets pipe &scour pipes etc. in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. (Labour rate) |
70 | 50 mm dia (Light class) |
71 | 150 mm dia (Medium class) |
72 | Providing and fixing Gun Metal wheel valve of superior quality forfollowingdiascrewedtypeas per IS:778Marked complete in all respect as per direction and to the entire satisfaction of Engineer-in-charge |
73 | 50mmdia |
74 | Providing and fixing of 3.15mm MS Sheet Manhole cover 600X600mm fixed on all sides with ISA 40x25x5mm top angle iron frame hinged on ISA 35x35x5mm bottom angle iron frame as per drawing. Pieces of MS Flat 20x4mm, 0.15m long be fixed on all sides as hold fast. The operation of manufacturing shall including cutting of MS Sheet, Angle Section & welding of MS Sheets, Angle Section, Hinges, Handles 150mm long, 20x4mm flats, locking arrangement and applying a priming coat of steel primer after pretreatment of surface to the entire satisfaction of the Engineer-in-Charge. |
75 | Rising Main:- Providing laying, jointing and testing in trenches (to level or grade) ofpipes jointed with 5% joint flanged & remaining butt weld joints of below diametreconforming toIS 3183 orIS 1239-1990 (Part - I ) with latest upto date amendments of grade and wall thickness as specified below, suitable to withstand required hydraulic test pressure in randum length 4m-6m with plain ends and jointed with MS Flanges conforming to IS 6392-1971(Latest upto date amendments) and welding of flanges as per IS 816-1969 with electrodes as per IS 814-1991 including required number and size of MS nuts and bolts as per IS 1369-1967 and compressed asbestos fibre jointing gaskets sheet not less than 3.00 mm in thickness as per IS 2712-1998. The welding of flanges to be done on both faces in two layers to make the joints leak proof and toentire satisfaction of the Engineer-in-Charge.The laying of pipes conform to IS 5822-1994 and as per CPHEEO manual and will include all operations such as cutting, welding and jointing including flushing, cleaning and hydraulic testing. (Excavation in trenches, welding of flanged joints shall be measured & paid extra). |
76 | Pump house to MBR Hawani (RD 0 to 500) GMSREW 80mm L210(4.80 mm) F.T - 34 |
77 | Pump house to MBR Hawani (RD 500-900) GMSREW 80mm L210(4.8mm) F.T - 28 |
78 | Pump house to MBR Hawani (RD 900-1300) GMSREW 80mm L210(4.8mm) F.T - 28 |
79 | Pump house to MBR Hawani (RD 1300-1600)GMSREW 80mm L210(4.8mm) F.T - 17 |
80 | Pump house to MBR Hawani (RD 1600-1800)GMSREW 80mm L210(4.8mm) F.T - 17 |
81 | Pump house to MBR Hawani (RD 1800-2100)GMSREW 80mm L210(4.8mm) F.T - 17 |
82 | Booster Stage (RD 0-250)IS 1239-1990 150mm (M)FT-5 (Labour Rate) |
83 | Providing and welding M.S. flanges at suitable point, conforming to following tables as per IS 6392-1971 (Latest with up to date amendments) with plain end API pipe in twolayers on both faces to make the joint leak proof (The cost of providing and laying of API pipes and butt welded joint to be measured and paid for separately). The welding of flanges should conform to IS: 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364 including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00mm conforming to IS 2712-1998. The work shall be done to the entire satisfaction of Engineer in Charge with in all leads and lifts. |
84 | Pump house to MBR Hawani (RD 0 to 500) GMSREW 80mm L210(4.80 mm) F.T - 34 |
85 | Pump house to MBR Hawani (RD 500-900) GMSREW 80mm L210(4.8mm) F.T - 28 |
86 | Pump house to MBR Hawani (RD 900-1300) GMSREW 80mm L210(4.8mm) F.T - 28 |
87 | Pump house to MBR Hawani (RD 1300-1600) GMSREW 80mm L210(4.8mm) F.T - 17 |
88 | Pump house to MBR Hawani (RD 1600-1800) GMSREW 80mm L210(4.8mm) F.T - 17 |
89 | Pump house to MBR Hawani (RD 1800-2100) GMSREW 80mm L210(4.8mm) F.T - 17 |
90 | Booster Stage (RD 0-250)IS 1239-1990 150mm (M)FT-5 |
91 | Providing circumferential butt welded joints by electrical arc welding to MS pipe, welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes conforming to IS 814-1991, at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge. |
92 | Pump house to MBR Hawani (RD 0 to 500) GMSREW 80mm L210(4.80 mm) F.T - 34 |
93 | Pump house to MBR Hawani (RD 500-900) GMSREW 80mm L210(4.8mm) F.T - 28 |
94 | Pump house to MBR Hawani (RD 900-1300) GMSREW 80mm L210(4.8mm) F.T - 28 |
95 | Pump house to MBR Hawani (RD 1300-1600) GMSREW 80mm L210(4.8mm) F.T - 17 |
96 | Pump house to MBR Hawani (RD 1600-1800) GMSREW 80mm L210(4.8mm) F.T - 17 |
97 | Pump house to MBR Hawani (RD 1800-2100) GMSREW 80mm L210(4.8mm) F.T - 17 |
98 | Booster Stage (RD 0-250) IS 1239-1990 150mm (M)FT-5 (Labour Rate) |
99 | Providing and fixing double flanged cast steel non return valve of 80 mm dia of Kirloskar/Leader make to conforming to BS:1868 / API-600 class ASA-300 including M.S. flangesas per IS 6392-1971including welding of flanges and capable of with standing of nominal seat pressure with upto date amendments including carriage within all leads and liftsas per direction and to the entiresatisfaction of Engineer-in-Charge. |
100 | 80 mm diaFT 34, ASA-300 |
101 | 150 mm diaFT 5, ASA-300 |
102 | Providing and fixing double flanged cast steel Sluice valve of 80 mm dia of Kirloskar/Leader make to conforming to BS: 1414/API-600 Class ASA-300 including M.S. flangesas per IS 6392-1971including welding of flanges and capable of with standing ofseat pressure with upto date amendments including carriage within all leads and liftsas per direction and to the entiresatisfaction of Engineer-in-Charge. |
103 | 80 mm diaFT 34, ASA-300 |
104 | 150 mm diaFT 5, ASA-300 |
105 | Gravity Main:- Laying, jointing and testing in trenches (to level or grade) of following dia Medium Class GMS pipes plain ended jointed with flanged and butt weld joints with of below diametreconforming to IS 1239-1990 (Part - I ) with latest upto date amendments of grade and wall thickness as specified below, suitable to withstand required hydraulic test pressure in randum length 4m-6m with plain ends and jointed with butt welding with electrodes as per IS 814-1991. The welding of joint to be done to make the joints leak proof (earth work to be mearsured and paid separately) and toentire satisfaction of the Engineer-in-Charge.The laying of pipes conform to IS 5822-1994 and as per CPHEEO manual and will include all operations such as cutting, welding and jointing including flushing, cleaning and hydraulic testing complete in all respect. Excavation in trench, providing and welding of M.S. Flanges and butt welded joint shall be measured and paid for seperately . (L.R.) |
106 | 150 mm dia Medium Class (Labour rate). |
107 | 100 mm dia Medium Class (Labour rate). |
108 | 80 mm dia Medium Class (Labour rate). |
109 | Providing, laying, jointingand testingin trenches of GMSERWfully Buttwelded pipe conforming toIS/ISO:3183-2007, L210 or A of below mentioned grade in item as per dimensions, weight and test pressure mentioned there in code (mill tolerances to be restricted within 3%) in random lengths of6 to 7 mtrs including the cost of fabrication of bends by butt welding from parent tube as required at site. The welded joints and welding of pipe will be down as per IS:816-1969 with electrodes as per IS:814-1991 of make Adwani/Orelon (Adore)/ESAB. The laying & jointing of pipe should conform to IS:5822-1994 (earth work in trenches except in bends to be measured and paid for separatly)The pipes and specials shallhave out side coating with galvanised as per BIS 4736, the galvanisation is done by the manufacturing frim itself complete in all respect as per direction and to the entire satisfaction of Engineer-in-Charge. |
110 | 250mm dia GMSERW pipe grade L210 or A having wall thickness 4.80mm |
111 | Providing and fixing double flangedCast Ironsluice valveof following dia of Kirloskar/Leader make conforming to IS:14846/2000with up to date amendment as per Class PN-1.00 to withstand in normalseat pressureincluding welding with M.S. flanges as per IS 6392-1971 including carriage in all leads and lifts as per direction and to the entiresatisfaction of Engineer-in-Charge. |
112 | 125 mm Dia |
113 | 250 mm Dia |
114 | 150 mm Dia |
115 | 100 mm Dia |
116 | 80 mm Dia |
117 | Providing & Fixing of Puddle collar of different dia including carriage in all leads and lifts as per direction and to the entiresatisfaction of Engineer-in-Charge. |
118 | 150 mm Dia |
119 | 100 mm Dia |
120 | 80 mm Dia |
121 | Providing and fixing PVC water storage tank of ISI : 12701 marked, G.I. inlet and outletconnection, 15mm nominal bore ball valve and mosquito proof PVC cover with lockingarrangement including hoisting up to all heights above ground level :-1000 litres net capacity tank Syntax make. |
122 | Providing & Fixing to wall, ceiling & floor , galvanised milt steel tubes (Heavy Class) , tube fittings & clamps i/c making good the wall, ceiling & floor. |
123 | 20mm dia Nominal Bore TATA Make |
124 | 15mm dia Nominal Bore TATA Make |
125 | Repair of WTP at Kandapattan:- Supply, erection and supervision of Electromechanical equipments for various components of 1.32 MLD plant. (Refer Data Sheet No.-1) |
126 | Construction and commissioning of water treatment plant 0.15 MLD Capacity in shape of Rapid sand filter bed and allied unit :- The scope of work includes the construction of 0.15 MLD Capacity water treatment plant capable to treat the raw water of the quality specified in the basic design data to produce clear water as per the requirement of CPHEEO manual on water supply and treatment and as specified in basic design data. The water treatment plant shall include the construction of inlet chamber, raw water tank, presetting tank, Parshall flume, Flash mixer, alum solutiontanks and dosing arrangement flocculator settling tanks, rapid sand filter complete with back wash arrangement, clear water tank, complete disinfection arrangement with bleaching power, Elector Mechanical equipment piping values mechanical /electrical equipment electric wiring & panel board, sanitation, floodlights interconnection paths, site development up to a minimum of 3m from edge of battery limit of plant i/c retaining and breast walls and fencing. The firm shall submit the detailed hydraulic and structural design and drawings (6 copies) for each component of treatment plant which shall be approved by the department before the work is started. The design/drawing and bearing capacity of soili/c detailed survey and investigation of the mechanical /electrical equipment & wiring etc. along with manufactures specification /design also be submitted for approval by the department on the completion of all civil, mechanical and electrical works the contractor shall test run the plant for three months (90 days) before handing over the same to the department at the cost of the contractor. However, electrical charges shall be borne by the department .During this periods the contractor shall run the plant at full rated capacity and produce the results specified in the NIT as per the CPHEEO standers in the presence of Engineer –in –Charge. (Data sheet No -2) |
127 | Providing and fixing vitreous china wash down water closet (European type W.C. Pan) with integral "P" or "S" trap including jointing the trap with soil pipe in cement mortar 1:1 (1 cement : 1 sand) (seat and cover to be measured and paid for separately) |
128 | Providing and fixing plastic seat (siolid/hollow type) and cover for wash down water closet with CP brass hinges rubber buffers:- white plastic seat and cover. |
129 | Providing and fixing 10.0/12.50/25.00 litres vitreous china low level flushing cistern with a pair of C.I. or mild steel brackets, complete with fittings such as lead valve less syphon 15mm nominal size brass valve with polythene float, C.P. brass handle unions and couplings for connections with inlet, outlet and overflow pipes 40mm dia C.P. flush bend including cutting holes in walls and making good the same and connecting the flush bend with cistern and closet (overflow pipe to be measured and paid for separately) |
130 | Providing and fixing vitrous china wash basin with single hole for pillar tap with C.I. or M.S. brackets painted white including cutting holes and making good the same but excluding fittings550mm X 400 mm |
131 | Providing and fixing PVC waste Pipe 32 mm dia wash basin or sink including brass check nut complete. |
132 | Providing and fixing brass bib cock 15 mm dia (Heavy duty)i/c entire carriage of material within all leads and lifts. |
133 | Providing and fixing brass stop cock (concealed) 15 mm dia (Heavy duty)i/c entire carriage of material within all leads and lifts. |
134 | Providingandfixingstainlesssteelkitchen sink of approved standard ISI make with drain board and C.P. waste with C.I. or M.S. Brackets painted white including cutting holes andmakinggoodthesamebutexcluding fitting. 610 x 510 mm with bowl depth 200 mm within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
135 | Providing and Fixing 600 mm x 450 mm bevelled edge mirror of superior glass marked on 6mm thick AC sheet or plywood sheet and fixed to wooden plug with CP brass screws and washer within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. |
136 | Providing and Fixing ball valve (brass) of approved quality, high or low pressure with plastic floats 15mm size complete. |
137 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group-C |
138 | Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. |
139 | Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:- |
140 | 4 modules (140mmx78mmx50mm) |
141 | 6 modules (205mmx78mmx50mm) |
142 | 8 modules (120mmx135mmx60mm) |
143 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. |
144 | 2x1.5 Sq. mm. |
145 | 2x2.5 Sq. mm. |
146 | 2x4.0 Sq. mm. |
147 | Wiring for circuit / sub-main with 4x6 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.6 Sq.mm. (4x6+2x6) HRFRLS/PVC insulated single core copper conductor cable for earthing wire from MCB box to main pannel board. |
148 | Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulatedheat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing three phase wiring in main pannel board for busbar. |
149 | Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. |
150 | S.P. 5/ 6 Amps one way Modular switch. |
151 | 5 pin, 5/ 6 Amps Modular socket outlet. |
152 | Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. |
153 | S.P. 15/ 16 Amps one way Modular switch |
154 | Supplying and fixing ceiling rose on the existing junction box /wooden block including connections etc. as required. |
155 | Supplying and fixing of Double door-12 way single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnec- tions, phosphatized and powder painted, including earthing etc. as required. |
156 | Supplying and fixing 63 Amps. Cat-A rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
157 | Supplying and fixing sheet metal bus-bar chamber suitable for 200 Amp. 415 volts capacity with 4 No. copper strip bus-bars Each of length 450mm & cross-sectional area(25.4mmx4.75mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (530mmx450mmx 150mm) nominal with all accessories including connections, earthing the body etc. as required. |
158 | Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, "C" curves, miniature circuit breaker of Single pole & neutral. Cat-B in the existing MCB DB complete with connections etc. as required:- |
159 | Supplying and erection of wall mounted metal boards for switch gear mounting of suitable size, with permissible variation in size of plus minus 5mm, welded frame work made of M.S. angle iron 35 mm x 35 mm x 6 mm thick duly welded complete with 2.80mm thick M.S. sheet fixed with hinges as open able front, complete with locking arrangement including painting and bonding to the existing earth as required:- |
160 | Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, "C" curves, miniature circuit breaker of Double pole. Cat-B in the existing MCB DB complete with connections etc. as required:- |
161 | Supplying and fixing 40 Amps. Cat-B rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
162 | Supplying and fixing 20 Amps, 240 volts, SPN industrial socket outlet, 2-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 20 Amp SPN-MCB/DP, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required. |
163 | Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. |
164 | Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required. |
165 | Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required. |
166 | Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run) |
167 | Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run) |
168 | Providing and fixing M.V.danger notice plate of 200 mm x 150 mm made of mild steel at least 2 mm thick, and vitreous enameled white on both sides and with inscription in signal red color on front side as required. |
169 | Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, Armoured/ XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the Armoured cable 4 sq. mm (twin core) for Yard lights. |
170 | Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. Ceiling Fan 1400 mm sweep, Category-A |
171 | Providing and installation of Exhaust Fan, Light duty, (Domestic) 225 mm sweep in the existing opening, including taking the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. |
172 | Providing and fixing 1x36 watt-LED (Category-A)surface mountingfixture Syska/Havells make |
173 | Providing and fixing 6 watt. Recessed down lights round shape for falce ceilings complete. |
174 | Supplying and fixing of fancy wall bracket containing thread type LED lamp holder (s) of all sizes and shapes, complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. Fixed type wall bracket 150 dia, single lamp.(Category-A) |
175 | Providing, Installation, testing and commissioning of tube fitting 1x20W LED coplete in all respect. |
176 | Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required |
177 | Supplying and fixing 9 watt.LED bulbs. |
178 | Supplying and fixing bakelite batten/angle holder including connections etc. as required. |
179 | Supplying and fixing of integral LED. Post Top Lantern of following capacity, cast aluminium spigot, spun aluminium canopy, opal acrylic diffuser, complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. Gate post top lantern - CFL 26 watt. |
180 | Wiring for light / Fan point / Exhaust fan point / call bell point with 1.5 Sq.mm PVC insulated copper conductor cable in surface/recessed PVc conduct at required including of all material within all leads and lifts. |
181 | Wiring for light / power plug with 2 x 4 Sq.mm PVC insulated copper conductor or single core cable in surface/ recessed steel conduit alongwith 1 No.2.24 mm dia bare copper wire for loop earthing as required including carriage of materials within all leads and lifts. |
182 | Wiring for Circuit wiring with 2 x 1.5 Sqm.mm PVC insulated copper conductor single core cable in surface/rcessed steel conduit as required including carrige of material upto all leads and lifts. 2 x 6 Sq.mm |
183 | Wiring for sub-main wiring with the following size of copper conductor single core cable in surface/ recessed steel conduit as required including carriage of materials upto all leads and lifts. |
184 | Supplying and fixing metal box of 180 x 100 x 60mm deep (Nominal size) on surface/ recess with suitable size phonolic laminated sheet cover fixing 3 pim 15/16 amps socket tumber/piano type switch connections painting etc. inculding carriage of materials within all leads and lifts. |
185 | Supplying and fixing backellite batten/angle holder including connection as required. |
186 | Providing, installing, testing and commissioning of celling fan and regulator inculding wiring the road of standard length (upto 30 cm) with 1.5 Sqmm PVC insulated copper conductor single core cable etc. as required sweep type. |
187 | Providing, installing, testing and commissioning of prewired flourscent tube fitting complete with ballast, starter and capactors but excluding flourscent tube rod, suitable to operate on 230 volts single phase A.C. supply directly on surface with copper wiring as required including carriage of materials within all leads and lifts tube fixture 1 x 36 watt Box Type Category "A". |
188 | Supplying and fixing 40 Amps to 63 Amps rating 240 Volts "L" series miniature circuit breaker of following poles in the exixting MCB DB complete with connections, testing and commissioning etc. as required inculding carriage of material within all leads and lifts. Category-A, 63 Amps. |
189 | Supplying and fixing of following two way single pole and netural sheet steel MCB distribution board 240 volts on surface/recessed completed with tinned, copper bus bar, netural link, earth bar, din bar detachable gland plate inter - connections, including painting, earthing etc. as required Bus bar 8 way. |
190 | Supplying and fixing 5 Amps to 32 Amps rating 240 volts, G series miniature circuit breaker of following poles in the existing MCB, DB complete with connections testing and commissioningetc. as required |
191 | Earthing with G.I. pipe earth, pipe 4.5 length, 40 mm dia including accessories and providing masonry enclousres with cover plate having locking arrangement and watering pipe etc. ( but without charcal coke and salt) complete as required including carriage of materials within all leads and lifts. |
192 | Extra using salt and charcoal for pipe earth electrode as required, including carriage of materials within all leads and lifts. |
193 | Supplying and laying 6 Sqmm G.I. wire at 0.50 mtr below ground level for conductor earth electrode, including soldering etc. as required including carriage of materials within all leads and lifts. |
194 | Providing, fixing & testing Street Light Fixture with CFL of 36 watt, copper ballast, G.I Pipe bracket, complete in all respects. |
195 | Wire crates made ofG.I. wire filled with boulders with square cut faces against the wire(wire crates to be measured and paid for separately) |
196 | Wire crate made of GI wire filled with boulders with squre cut faces against the wire (boulder filling to be measured and paid for seperately)G.I. wire 5mm thick 15cmsx 15cms mesh as per satisfaction of Engineer in Charge. |
197 | Pumping Machinery Submersible (LWSS Reur Didnoo Hawani):- Supply ofsubmersible pump ofKSB /Calama/Johnston/SU/Kirloskar make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water prrof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrut bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- |
198 | SITE CONDITION Total Head 16.24mtrs Discharge required 5.09LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 735 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other Length of R/main 115 mtrs Dia of Rising main 80 mm dia. No of working hours.8 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days. |
199 | Supply of DOL Starter of reputed make i.e L&T/Siemen conforming to BIS 8544 -( Part - )1979 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for _3.0_HP motor. |
200 | Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge. |
201 | Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-30 Amp. capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments. |
202 | Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments. |
203 | ICTP switches with HRC fuses of Havells/L&T/standard /cromption make for required motor of 3.0 HPcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments. |
204 | Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS: 8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendmentsof suitable rating. |
205 | MCB/MCCB of 32 Amp suitable for motor of 3.0 HP capacity of Havells/standard/MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release. |
206 | 3 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts. |
207 | 50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications. |
208 | Supply of Kirloskar/ leader make cast iron (class PN-1.00 ) double flanged sluice valve of 65 mm dia.and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000. |
209 | Supply of Kirloskar/leadermake cast iron (class PN-1.00 ) double flanged ( swing check type) reflux valve having bye pass arrangement and 65 mm dia.and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS : 5312-Part-I-2004. |
210 | Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 4.0 sqmm or ofSuitable sizes. |
211 | Supply of Leader /Kirloskar make80 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 80 mm dia. of rising i.e. 80 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004 |
212 | Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender. |
213 | Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s. |
214 | Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments. |
215 | Providing and laying delivery pipe 65 mm dia. and common header 80 mm dia GMS pipe Medium classas per IS:_1239-2004jointed with MS flanges of table -5as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge. |
216 | Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer). |
217 | Supply of suitable cable for water level guard |
218 | Supply of supporting clamps. |
219 | Supply of cable clips of required size. |
220 | Erection of all equipment from Sr. No. 127 to 139 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge. |
221 | Pumping Machinery Submersible (LWSS Kandapattan to Mandap):- Supply ofsubmersible pump ofKSB /Calama/Johnston/SU/Kirloskar make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water prrof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrut bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:- |
222 | SITE CONDITIONTotal Head 32.67mtrs Discharge required17.04LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 636 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other Length of R/main 250 mtrs Dia of Rising main 150 mm dia. No of working hours.16 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days. |
223 | Supply of star delta starter 63 AMP of reputed make i.eMEI/Kilburn or of approvrd make conforming to BIS 8544 -( Part - )1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 20 HP motor. |
224 | Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge. |
225 | Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-60 Amp capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments. |
226 | Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments. |
227 | ICTP switches with HRC fuses of Havells/L&T/standard /cromption make for required motor of 63 Ampcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments. |
228 | Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS: 8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendmentsof suitable rating. |
229 | MCB/MCCB of suitable capacity of Havells/standard/MDS/Jyoti/Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release. |
230 | 3 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts. |
231 | 50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications. |
232 | Supply of Kirloskar/ leader make cast iron (class PN-1.00 ) double flanged sluice valve of 125 mm dia.and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS : IS :14846-2000. |
233 | Supply of Kirloskar/leadermake cast iron (class PN-1.00 ) double flanged ( swing check type) reflux valve having bye pass arrangement and 125 mm dia.and capable of with standing nominal seat pressure of 10.20 kg/cm2 as perIS : 5312-Part-I-2004. |
234 | Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side Suitable sizes. |
235 | Supply of Leader /Kirloskar make 150 mm dia. cast ironclass PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 150 mm dia. of rising i.e. 150 mm for withstanding nominal seat pressure of 10.20 Kg/Cm 2 as per IS :5312-Part-I-2004) |
236 | Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender. |
237 | Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s. |
238 | Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments. |
239 | Providing and laying delivery pipe 125 mm dia. and common header 150 mm dia Heavy classas per IS:-1239-2004 Part-Ijointed with MS flanges of table -5as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge. |
240 | Supply of floor/wall mounted power factor shunt capacitorconforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer). |
241 | Supply of suitable cable for water level guard |
242 | Supply of supporting clamps. |
243 | Supply of cable clips of required size. |
244 | Erection of all equipment from Sr. No. 142 to 154 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge. |
245 | Centrifugal Pump:- Supply ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistagecentrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar make conforming to BIS 1520-1980) pump (Latest with up toto date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling sliperring squirrel cage screen protected drip proof electric induction motor of standard make such as Kirloskar/ NGEF/Cromption conforming to IS 12615-2018 and should be energy efficient IE2 complaint and TEFC type ( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts,m painting etc. and shall be and suitable for operation on the date given below: |
246 | SITE CONDITIONTotal Head491.83 mtrs Discharge required4.00 LPS each set. No. of Pump required. 2.00 Nos sets (1 act as stand bye) Length of R/main 2100.00 mtrs. Dia of R/main80mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). Head Load (for the installation of both machinery). The Altitude of :-The Altitude of place is750 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.8 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days. |
247 | Providing ICTP Main Switch 200 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB |
248 | Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:- |
249 | M.C.C.B. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with. |
250 | E.L.R of Havell/MDS/INDETEC make as per IS: 2516-1977 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. |
251 | The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition). |
252 | 100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments. |
253 | Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating. |
254 | Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating. |
255 | Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 200 Amp. |
256 | ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. |
257 | Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments. |
258 | 100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-200) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments. |
259 | Capacitor of L&T/Bajaj/Assian/Crompton make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 16 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of Siemens/Glocter/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments |
260 | Providing suitable Auto Trasformer starter of M.E.I / Kilburn.make as per IS:8544 (Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments. |
261 | Providing Hour run meter of recommended make as per IS: 722 (Latest edition) |
262 | Providing doubleflanged Cast iron sluice valve of Leader/Kirloskar make of 100 mm dia for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments. (Class PN-1.60) |
263 | Providing double flangedCast steel sluice valve of Leader/Kirloskar make and size of 65 mm dia.and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS : 1414 / API - 600 (ClassASA-300). |
264 | Providing double flangedCast steel reflux valve of Leader/Kirloskar make andsize of 65 mm dia.and capable of with standing nominal seat pressure of 52 kg/cm2 as per: BS : 1868 / API - 600 (ClassASA-300) . |
265 | Providing double flangedCast steel 80mm non return valve of Leader/ Kirloskar make having bye pass arrangement for rising main and capable of with standing normal seat pressure of 52 kg/cm2 as per BS : 1868 / API - 600 (ClassASA-300) . . |
266 | Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2 |
267 | Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury. |
268 | Installation of all the items appearing at Serial No. 158 to164 as per thesystematic drawingattached with the tender documents ( Drg.No.1) |
269 | Providing and fixing double flanged 80 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1. |
270 | The size of the various components to be as under:-(i) Suction pipe 100_mm diaMin. length = 10 mtr.(ii)Delivery pipe65 mm dia -do- = 6 mtr. (iii) Common Header 80 mm dia -do- = 6 mtr. and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. |
271 | Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS:1554 (P-I) 1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. |
272 | (i)Motor side:25mm2Min length = 20 mtrs. |
273 | (ii)Supply side: 50 mm2 Min. length =10 mtrs. |
274 | Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail