Tender For Source Strengthening And Rehabilitation Of Various Water Supply Schemes Under Jal Shakti Sub Division Tihra In Tehsil Dharampur Distt. Mandi Hp, bharari-Himachal Pradesh

Irrigation And Public Health Department has published Tender For Source Strengthening And Rehabilitation Of Various Water Supply Schemes Under Jal Shakti Sub Division Tihra In Tehsil Dharampur Distt. Mandi Hp. Submission Date for this Tender is 26-06-2023. Pumping Machiney Tenders in bharari Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38226836
Corrigendum : Tender For Source Strengthening And Rehabilitation Of Various Water Supply Schemes Under Jal Shakti Sub Division Tihra In Tehsil Dharampur Distt. Mandi Hp
Open Tender
Indian
Himachal Pradesh
bharari
26-06-2023

Tender Details

Source Strengthening And Rehabilitation Of Various Water Supply Schemes Under Jal Shakti Sub Division Tihra In Tehsil Dharampur Distt. Mandi Hp Plj And Testing Of Rising Main And Se Of Pumping Machinery Under Jjm

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Jun-2023 corrigendum Other 26-06-2023

Key Value

Document Fees
INR 1500 /-
EMD
INR 154886.0 /-
Tender Value
INR 1.22 Crore /-

BOQ Items

Name of Work: Source Strengtheningand rehablitation of various water supply schemes under Jal Shakti Sub-Division Tihra in Tehsil Dharampur Distt. Mandi (H.P.) (SH:- P/L/J and testing of rising main and S/E of Pumping Machinery) (Under JJM)
Sl. No. Item Description
1Excavation in foundation and trenches in earth work upto all depth in all kinds of soil such as pick work jumper work, blasting work, chiselling of soft /hard rock where blasting is prohibited in all leads and lifts and including trimming of sides levelling of bed to correct grade stacking the excavated soil in 15cm.layers when required into plinth sides of foundation including consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed in all leads including lifts and soring/strutting timbering and dewatering where ever required as per thr direction and to the entire satisfaction of the Engineer-in-charge.
2Laying, jointing and testing in trenches (to level or grade) ofGMS pipes jointedwith 1% joint flanged & remaining butt weld 99% joints of below diametreconforming to IS 1239-1990 (Part - I) with latest upto date amendments of grade and wall thickness as specified below, suitable to withstand required hydraulic test pressure in randum length 4m-6m with plain ends and jointed with MS Flanges conforming to IS 6392-1971(Latest upto date amendments) and welding of flanges as per IS 816-1969 with electrodes as per IS 814-1991 including required number and size of MS nuts and bolts as per IS 1369-1967 and compressed asbestos fibre jointing gaskets sheet not less than 3.00 mm in thickness as per IS 2712-1998. The welding of flanges to be done on both faces in two layers to make the joints leak proof and toentire satisfaction of the Engineer-in-Charge.The laying of pipes conform to IS 5822-1994 and as per CPHEEO manual and will include all operations such as cutting, welding and jointing including flushing, cleaning and hydraulic testing complete in all respect. Excavation in trench, providing & welding of M.S. Flanges and butt welded joint shall be measured and paid for seperately. (Labour rate)
3100mm dia Heavy Class, wall thickness 5.4mm, FT-28/17 (From RD 0 to 925m)
4Providing, laying, jointingand testingin trenches bevelled ended BIS marked GMSERW pipes of various grade fully Buttwelded conforming toIS/ISO:3183-2007, L210 or A of below mentioned grade in item as per dimensions, weight and test pressure mentioned there in code (mill tolerances to be restricted within 3%) in random lengths of6 to 7 mtrs including the cost of fabrication of bends by butt welding from parent tube as required at site. The welded joints and welding of pipe will be down as per IS:816-1969 with electrodes as per IS:814-1991 of make Adwani/Orelon (Adore)/ESAB. The laying & jointing of pipe should conform to IS:5822-1994 (earth work in trenches and butt welded joints except in bends to be measured and paid for separatly)The pipes and specials shallhave out side coating with galvanised as per BIS 4736, the galvanisation is done by the manufacturing firm itself complete in all respect as per direction and to the entire satisfaction of Engineer-in-Charge. (Earth work, flanged joint & butt welded joint shall be measured & paid separately)
5200mm dia GMSERW pipe grade L210 or A having wall thickness 4.80mm, FT-17/5
6Providing and weldingM.S. flanges @ 1% of joints conforming to following Table at suitable point, conforming toIS 6392-1971 (Latest with upto date amendments) with plain end GMS/MSERW pipe in requsite number of layers on both faces to make the joint leak proofThe welding of flanges should conform to IS:816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364. including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00mm conforming to IS 2712-1998. The work shall be done to the entire satifaction of Engineer in Charge with in all leads and lifts.
7100mm dia, wall thickness 5.4mm, FT-28
8100mm dia, wall thickness 5.4mm, FT-17
9200mm dia GMSERW pipe grade L210 or A having wall thickness 4.80mm, FT-17
10200mm dia GMSERW pipe grade L210 or A having wall thickness 4.80mm, FT-5
11Providing circumferencial Butt welded joints by electrical arc welding to following dia MSERW/GMS pipe,welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5mm to 6.3mm of Advani Oerlikon (Adore)- CITOJET/ESAB make, conforming to IS 814-1991, at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
12100mm dia Heavy Class, wall thickness 5.4mm
13200mm dia GMSERW pipe grade L210 or A having wall thickness 4.80mm
14Providing and fixing double flanged cast steel Sluice valve of following dia of Kirloskar/Leader or any other approved make conforming to BS: 1414/API-600 Class ASA-150 including M.S. flanges table-28 as per IS 6392-1971including welding of flanges and capable of with standing of nominal seat pressure 21.00 Kg/cm² with upto date amendments including carriage within all leads and liftsas per direction and to the entiresatisfaction of Engineer-in-Charge.
15100mm dia
16200mm dia
17Centrifugal Pump:- Supply ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistagecentrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar make conforming to BIS 1520-1980) pump (Latest with up toto date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling sliperring squirrel cage screen protected drip proof electric induction motor of standard make such as Kirloskar/ NGEF/Cromption conforming to IS 12615-2018 and should be energy efficient IE2 complaint and TEFC type ( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts,m painting etc. and shall be and suitable for operation on the date given below:
18SITE CONDITION Total Head174.33 mtrs Discharge required6.67 LPS each set. No. of Pump required. 2.00 Nos sets (1 act as stand bye) Length of R/main 925.00 mtrs. Dia of R/main100mm dia Location of the site of installation of machinery-The site is located at a distance of 20 Km from Dharampur at Tasli Nallah by road & 0KM on head load The Altitude of :-The Altitude of place is1002 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Clear Water Charactristics of water:- a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days.
19Providing ICTP Main Switch with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
20Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
21M.C.C.B. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
22R.C.C.B. 100 Amp. of Havell/MDS/INDETEC make as per IS: 2516-1977 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
23The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
24100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments.
25Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating.
26Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating.
27Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 100 Amp.
28ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments.
29Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
30100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-200) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments.
31Capacitor of L&T/Bajaj/Assian/Crompton make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof suitable ratingaccordingto HP offered including cables as per relevant ISI code (of Siemens/Glocter/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments (Range to be specified by the tenderer)
32Providing suitable Star Delta starter of L&T/Havells/M.E.I make as per IS:8544 (Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
33Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
34Providing doubleflanged Cast iron sluice valve of Leader/Kirloskar make of 100 mm dia for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments. Class PN-1.6
35Providing double flangedCast steel sluice valve of Leader/Kirloskar make and size of 80 mm dia (ASA-300).and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS : 1414 / API - 600.
36Providing double flangedCast steel reflux valve of Leader/Kirloskar make andsize of 80 mm dia.and capable of with standing nominal seat pressure of 52 kg/cm2 as per: BS : 1868 / API - 600.
37Providing double flangedCast steel 100mm non return valve of Leader/ Kirloskar make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS : 1868 / API - 600. .
38Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
39Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
40Installation of all the items appearing at Serial No. 9 to15 as per thesystematic drawingattached with the tender documents ( Drg.No.1)
41Providing and fixing double flanged 125 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
42The size of the various components to be as under:-
43(i) Suction pipe 125 mm diaMin. length = 15 mtr.
44(ii)Delivery pipe 80 mm dia -do- = 5 mtr.
45(iii) Common Header 100 mm dia-do-= 10 mtr.
46and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
47Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/GICO/Grandly/Nationalmake including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
48(i)Motor side:6 mm2 Min length = 20 mtrs.
49(ii)Supply side: 10 mm2Min. length =10 mtrs.
50Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
51Supply ofsubmersible pump ofKSB /Calama/Johnston/SU/Kirloskar make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water prrof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrut bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
52SITE CONDITION Total Head 77.50mtrs Static Head 67.30mtrs Discharge required 20.22LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery:The site is located at a distance of 6 Km from Dharampur at Kandapattan-Bahri & 0.10Km on head load The Altitude of :- The Altitude of place is 592 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other -- Static head in mtrs 67.30 mtrs. Length of R/main 1580 mtrs Dia of Rising main 200 mm dia. No of working hours.8 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
53Supply of star delta starter 63 AMP of reputed make i.eMEI/Kilburn or of approvrd make conforming to BIS 8544 -( Part - )1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 40 HP motor.
54Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge.
55Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-60 Amp capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments.
56Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments.
57ICTP switches with HRC fuses of Havells/L&T/standard /cromption make for required motor of 63 Ampcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
58Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS: 8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendmentsof suitable rating.
59MCB/MCCB of suitable capacity of Havells/standard/MDS/Jyoti/Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release.
603 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
6150 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
62Supply of Kirloskar/leadermake cast steel double flanged ( swing check type) reflux valve having bye pass arrangement and 125 mm dia (ASA-150)and capable of with standing nominal seat pressure of 21 kg/cm2 as per: BS : 1868 / API - 600.
63Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side Suitable sizes.
64Supply of Leader /Kirloskar make cast steel double flanged (swing check type) reflux valve having bye pass arrangement and 200 mm dia (ASA-150). of rising i.e. 200 mm for withstanding nominal seat pressure of 21.00 Kg/Cm 2 as per IS :1868/API-600
65Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender.
66Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s.
67Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
68Providing and laying delivery pipe 125 mm dia. and common header 150 mm dia Heavy classas per IS:-1239-2004 Part-Ijointed with MS flanges of table -5as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
69Supply of floor/wall mounted power factor shunt capacitorconforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
70Supply of suitable cable for water level guard
71Supply of supporting clamps.
72Supply of cable clips of required size.
73Erection of all equipment from Sr. No. 21 to 33 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
Disclaimer :