| 1 | Boring and Installation of Tube Well (Qnty. for 10 Pts) |
| 2 | Item No. 1 : Movement of drilling Rig , Tools & Plants, Accessories including drill pipes, casing pipes etc. to drilling site and back. |
| 3 | Item No. 2 : Boring of DTW of bore hole up to 450mm dia and up to a depth of 70 M or up to required depth by RC/DR Drilling Rig including supply and transportation of all required tools & Plants, materials & labour to site to perform the job in complete as directed in alluvium areas ( means areas where the strata comprises of loose, unconsiolidated materials like clays, silts, sands gravels, pebbles, cobbles and boulders) as per IS:2800 (part-1) of 1991. ( soil sample must be collected & keep properly at every 3.00 M interval of depth in boring. The job also include movement of rig by making temporary approach road etc. to the field up to distance of 1000M) |
| 4 | Item No. 3 : Supply, lowering & installation in tube well 200mm PVC housing pipe / blind pipe of wall thickness of 10.0 mm to 11.2 mm for casing assembly including supply of well cap, sockets, reducer, MS housing clamps etc. as required as per IS : 12818-1997 of length 3.00 M of Departmental Empanelled Brand &as directed.( Litholog Assembly diagram must be approved by Engineer-in-Charge of the work prior to installation) |
| 5 | Item No. 4 : Supply, lowering & installation in tube well 200mm PVC Ribbed Screen Filter pipe of wall thickness of 10.00 mm to 11.2mm for casing assembly including supply of sockets, reducer etc. as required as per IS : 12818-1992 of length 3.00 M/2.00 M of Departmental Empannelied Brand and as directed. |
| 6 | Item No. 5 : Shrouding the DTW assembly by river pea gravel of size 4 mm to 8 mm free from sand / dust and any other foreign materials after screening / stacking at site including supply, transportation, labour etc. complete as directed. (Additional pea gravel required if any during development may be extra subject to due approval from the ordering authority). |
| 7 | Item No. 6 : Developing the tube well assembly by Air-Compressor of capacity 8-12 kg/cm2 and CFM=450 M3/min so as to get sand free discharge of water with supply of all required materials at site complete as directed including furnishing of litho-log / draw down data etc. as per IS : 11185 of 1999. ( For new DTW minimum 72 hours development is compulsory. Additional pea gravel required if any, during development would be extra )The following data should be reflected in the report of development1. Static water level2. Drawdown at various discharge3. Available average discharge |
| 8 | Item No. 8 : Supply, fitting-fixing of Heavy duty CIDF sluice valve inside screw, non raising, vertical spindle type with hand wheel operation need of water purpose. The rotation of closing should be counter clock wise. The holes of the flange should be drilled as per BSS No. 10 , Part-I, Table-D. All materials construction and components should strickly conform to IS : 14846-2000 and having marked with manufacturers name and trade mark in the delivery pipe layout as directed / as per drawing along with HD GI flange, pipe joining materials and painting in complete as directed.(i) 100mm dia |
| 9 | Item No. 9 : Supply, fitting-fixing of Heavy duty CIDF Reflex valve, swing check type with bypass arrangement, horizontal operating. The holes of the flange to be as per BSS No. 10, Part-I, Table-D and the material, construction and all components should strictly conform to IS : 5312 (Part-I)-2004 and having arked with manufacturers name and trade mark in the delivery pipe layout asdirected / as per drawing along with HD GI flange, pipe jointing set and painting in complete as directed.(i) 100mm dia |
| 10 | Item No. 10 : Supply, fitting-fixing of delivery pipes of 80/100 mm dia GI / fabricated GI pipes ( HD of repute brand with ISI marked) with flange at both end / wherever required with pipe jointing sets, including painting in complete as per drawing / specification including temporary pipe support as required and as directed. |
| 11 | Item No. 11 : Ftting-fixing of MS / GI bend of 150mm dia x 450 / 900 / 1200 with GI / fabricated GI pipes with flange at both end and pipe jointing sets, including painting as per drawing / specification as directed. |
| 12 | Item No.12:-Supply of GI Equal Tee of 80/100 mm dia complete as directed. |
| 13 | Item No.13:-Fitting, Fixing of G.I. equal Tee of 80/100mm dia complete as directed. |
| 14 | Item No. 14 : Supply, fitting-fixing of surge tank of size 900m dia x 1250mm long made of 4mm MS plate with raiser assembly of size 75mm dia x 6.0m long and S-band of size 200mm x 1600mm long made of 4mm MS plate including painting the above with one coat of synthetic enamel primer fllowed by 2 (two) coats of successive synthetic enamel/ bituminous black paint and made provision for mounting the surge tank on a specified foundation by nuts & bolts of suitable size as per drawing & specification as directed. |
| 15 | Electric motor driven Submersible pump set (Qnty for 10 Pts) |
| 16 | Supply, Installation, Testing & Commissioning of electric motor driven submersible pump-set(7.5 HP/ 2900 RPM) and assembly of KSB/ KK/ CALAMA/ LUBI make as approved by DPC, Irrigation suitable for discharge capacity of 0.0212 cumec at 20 Mtr head conforming to IS : 8034–2002 including supply of all materials required for the work like column pipe of required diameter up to 20.00 Mtr length(as per IS: 1239 Part-II) The column pipes of 20 Mtr (approx) length should consist 6 nos of 3.0 Mtr length & 1 no. of 2.0 Mtr length. Each column pipe should have both end threaded & one end socketed . Flat motor cable up to 50.00 Mtr,he efficiency of the pump should not be below 75% of the rated duty point . (As per DPC rate & Annexure-VIII) 2(two) pairs of Assembly support MS clamp of size 150 mm, 10 nos flat cable clamp, 1(one) no GI delivery bend of size 150 mm x 900 , MS well cap of size 316 mm x 100 mm with provision to allow column pipe at centre, Starter stand made of MS angle ISA 5050, etc. in complete as directed . Apart from socketing, the column pipes should be joined by making MS angle joint for 150 mm dia column pipes with 3(three) pairs of clamp made of MS angle of size ISA 5050 to be welded on column pipe including supply of 3(three) nos of nuts& bolts (HT) of size 16 mm dia x 250 mm L at site as directedThe efficiency of the pump should not be below 75% of the rated duty point . (As per DPC rate & Annexure-VIII) |
| 17 | Control Room (Qnty for 10 Pts) |
| 18 | Earth work in excavation for foundation trenches includingfilling up sides of trenches and removal of spoils after completion of foundation , dressing, ramming, shoring etc. complete including bailing out water where necessary in ordinary soil. |
| 19 | CC Work in proportion 1:3:6 in foundation /abutment/ pier/wing walls etc. with hard brokenstone aggregate of size 13 to 38 mm including curing with necessary shuttering , Scafolding etc. where necessary, complete as directed. (shuttering where necessary shall be measured and paid separately).wall |
| 20 | Brick work in cement mortar with 1st class brick as directde in foundation, retaining walls, plinth & steps including recking out joints & curing wall |
| 21 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)Below wall |
| 22 | Supplyingfitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed.PostTie BeamStirrups for post (6 F |
| 23 | Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered)(B) Shuttering (beam) |
| 24 | (C) Shuttering (Column) |
| 25 | RCC work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:2:4 with hard broken stone aggregate of size 6 mm to 20 mm with proper reinforcement as per design including curing etc. with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately).Tie beamPost |
| 26 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)Wall |
| 27 | 12 mm cement plastering including clearing surface and curing complete as directed. |
| 28 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 29 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 30 | Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer |
| 31 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour |
| 32 | Soling in foundation in floor at all level septic tank etc. including filling interstices ramming etc. complete as directed and as specified thickness . |
| 33 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete |
| 34 | Underground PVC Pipe Distribution System (Qnty. For 10 pts) |
| 35 | Item No. 1: Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. |
| 36 | Item No. 2 : Supplying, fitting, fixing PVC Pipes (IS 12818, 6 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).a) Main line160 mm dia |
| 37 | b)Branch line 110mm dia |
| 38 | Item No. 3 : Supplying, fitting, fixing PVC unequal tee joining with pipes with solvent cement, testing leakages etc. complete as directed.Size 160 mm x 160 mm x 110 mm |
| 39 | Item No. 4 : Supplying, fitting, fixing PVC reducer joining with pipes with solvent cement, testing leakages etc, complete as directed.Size 160 mm x 110 mm |
| 40 | Item No. 5 : Supplying, fitting, fixing, 110mm dia NTP valve at the top of PVC rising pipe of spout chamber as per specification includinglocal carriage, testing leakage etc.complete as directed.Size : 110mm |
| 41 | Construction ofSpout Chamber (Qnty.for 10 pts. @ 7Nos./Pt.) |
| 42 | Item No. 1 :Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. |
| 43 | Item No. 2 :C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately). |
| 44 | Item No. 3 : 1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. (In proportion 1:4) |
| 45 | Item No. 4 : 12 mm cement plastering including clearing surface and curing complete as directed. In prop. 1: 4 |
| 46 | Item No. 5 : Supplying, fitting, fixing 110 mm dia PVC Rising pipe from the toe of main line includinglocal carriage, testing leakage etc.complete as directed. |
| 47 | Item No. 6 : Supplying, fitting, fixing PVC bend pipe sizejoining with pipes with solvent cement,testing leakages etc. complete as directed.110 mm / 900 |
| 48 | Item No. 7 : Supplying, fitting, fixing PVC Pipes (IS 12818, 4 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).110mm dia |
| 49 | Construction & fixation of Sign Board |
| 50 | Item No. 1 :Supply of sign board made of 1.60mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75m fixed with 2 Nos. 50mm dia GI (medium) pipes 2.10m above and 0.60m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed. |
| 51 | Drawl of HT Line and LT panel Board |
| 52 | Supplying & Erection of PSC Pole conforming to IS 1678 of Standard Dimension and of following lengths for overhead Electric Lines including digging of Earth Pit (0.75m × 0.5m) to a depth ?th of the Pole Length with a PCC Base Plate of size 60 cm × 60 cm × 12 cm at the bottom, refilling as specified with hard ramming as directed. (I) Refilling with Hard Soil9.75 Metres |
| 53 | Supplying and erection of MS Channel Cross Arm of following sizes for 11 kV Line on PSC/ Steel Poles along with Clamps, Nuts & Bolts duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed100mm × 50mm × 6mm × 2200 mm |
| 54 | Supplying and erection of MS Channel Cross Arm of following sizes for 11 kV Line on PSC/ Steel Poles along with Clamps, Nuts & Bolts duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed75mmX40mmX6mmX2200mm |
| 55 | Supplying and erection of Cross Bracing Sets for 11 kV Line on DP (Double Pole) Structure comprising of 2(two) Nos. of MS Angle of size 50 mm × 50 mm × 6 mm × 2200 mm fitted horizontally and other 2 Nos. 3200 mm long fitted diagonally along with MS Pole Clamps, Nuts Bolts and washer duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed |
| 56 | Supplying and Erection of 11 kV HT Stay Set comprising of 19mm dia × 1.8 m Stay Rod, Anchor Plate, Bow, Thimble etc. including supply and erection of 7/10 SWG G I Stay Wire and 11kV Guy Insulator complete including digging of Earth Pit of size (0.9m × 0.9m) to a depth of 1.4 Metre, placing the Stay Rod with Plate, fixing thimble, bow etc. with Boulder packing (size 150mm to 200mm) and hard ramming to fill up half the pit and filling with hard soil packing upto the Ground Level as directed |
| 57 | Supply and erection of G I Stay Wire 7/10 SWG along with 11 kV Guy insulator, binding to existing 11kV Stay Set and the GI Pole Clamp, tightening to required extent as directed. |
| 58 | Supplying and Erection of Hardware Fittings (3u bolt) on existing MS / GI Channel Cross Arm with GI Nuts and Bolts for mounting 11 kV Disc Insulator 45 kN as directed |
| 59 | Supplying and Erection of 11 kV Polymeric Disc Insulator 45 kN on existing Hardware Fitting on Cross Arm as directed |
| 60 | Supply and Erection of 11 kV Grade Aero Bunched Cable with 3(three) Power core, Stranded compacted, Circular Aluminium Conductor screened with black extruded semi conducting compound naturalcolour XLPE insulated core screened with black extruded semi conducting compound and one layer of copper tape and covered with black extruded PVC and one Bare messenger wire shall be stranded non-compacted circular aluminium alloy conductor. the cable should conform to IS:8130-1984, IS:398(Part-IV) 1994, IS:7098(Part-II) 2011 & IS:5831-1984 with up to date amendments. The job includes necessary Cable Joint, End Terminations, Anchor Clamp, Supension Clamps, Eye Hooks etc as directed by department. iii) 3 x 95 sqmm(P) + 1 x 70 sqmm (M) |
| 61 | Supplying and erection of Cross Bracing Sets for 11 kV Line on DP (Double Pole) Structure comprising of 2(two) Nos. of MS Angle of size 50 mm × 50 mm × 6mm × 2200 mm fitted horizontally and other 2 Nos. 3200 mm long fitted diagonally along with MS Pole Clamps, Nuts Bolts and washer duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed |
| 62 | Supplying, Fitting and Erection of 3-f 11 kV Gang Operated (G.O.) Air Break Switch having nominal System Voltage of 12 kV, rated Voltage 11 kV, rated Frequency 60 Hz, and peak current in closed position 46 kA, conforming to IS 2544, IS 5340(Part-III) and IS 9921(Part I to V) suitable to opearate in all climatic condition of following current ratings on existing Channels complete with Operating Pipe and Handle including making of necessary Electrical Connectionsas directed. 400 Amps |
| 63 | Supplying and Erection of 3-f 11 kV Drop Out (D.O.) Fuse Unit rated voltage 11 kV R.M.S. To 12 kV R.M.S., highest System Voltage 12 kV, each pole consisting of Polymeric insulator, all current carrying parts made of a highly conductive copper alloy and contact portion are silver plated for corrosion resistance and efficient current flow and the fuse tube made of fibre glass coated with ultraviolet inhibitr on the outer surface and having Arc Quenching bone fibre liner inside conforming to IS 9385/1983 of following current ratings on existing Channels complete with Barrel Fuse and making of necessary Electrical Connections as directed. (150 amp) |
| 64 | Supplying and Erection of Metal Oxide gapless Lightning Arrestor of following specification on MS Channel with Clamps, Nuts & Bolts including drilling of holes and making of necessary connection with Line Conductors as directed. 9 kV, 10 kA with Polymer body |
| 65 | Supply & Erection of C.I. Earth Pipe 100 mm dia × 2.5 Metre long perpendicular to the ground including digging of Earth Pit, putting Salt and Charcoal in alternate layers surrounding the pipe along withfitting of hinged CI top Cover Plate and necessary C.C. work as directed |
| 66 | Supply including Erection of 4 Star ON-AN (Oil Natural, air Natural) Cooled Al/ CU-wound Distribution Transformer conforming to IS specifications 2026 (with latest amendments) with all standard accessories erected on double pole structure/ transformer pad including transportation and handling, loading and unloading etc,, securing it on existing Channel firmly with necessary clamps, nuts & bolts . as required, and making necessary connections on HV and LV sides as directed (Cost of DP structure /Pad extra ) Capacity : 25 kVA, 11 kV/0.433 kV (4 Star Dyn) (A) Cost including Supply of Transformer |
| 67 | Supply & Erection of G.I. Earth Wire and Earthing of different Substation Items by connecting the existing Earth Pipes with G. I. Lugs as directed. 6 SWG G.I.Wire |
| 68 | Supply & Erection of Anti Climbing Barbed Wire on Poles at a height of about 3 Metres and covering a length of 1.5 Metre as directed |
| 69 | Supplying including erection of powder coated LT Feeder Panel for 25 kVA DTR (800mm × 1000mm × 400mm) made of 16 SWG CR sheet and 40mm × 40mm × 6mm MS angle having CR sheet roofing containing Cu Busbar and 1 no 63 A 415 V FP MCCB, making necessary connection through copper cablecomplete as directed. |
| 70 | Supply including Laying of PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor of size 35 Sq mm × 3 core in single line, Conforming IS 7098(Part I) 1988, direct in ground including digging of tren ch of 0.3 Mtr wide × 0.75 Metre deep including Sand Cushioning (7.5cm + 7.5cm) and refilling alongwith fitting, fixing of Brass Compression Gland and Aluminium Cable Lug etc. as directed |
| 71 | Danger plate suitable for 11KV line conforming to IS:2552/1963 of size 200mmX200mm |
| 72 | Providing Security fencing around the S/S with GI chain link net, woven with 10 SWG wire with mesh 7.5cm × 7.5cm to be erected on GI angle 40 mm × 40mm × 5mm, with necessary C C grouting, with a fencing height of 1.8 mtr, having a hinged door, fabricated with flat GI strip boundary and cross bracing, complete including supply of all materials, excavation refilling etc as reqd and as directed. |
| 73 | Testing and commissioning of the Substation alongwith obtaining necessary approval for charging from competent authority including payment of Inspection Fee, Arranging for Test Report etc. as required and as directed for following kVA Capacity |
| 74 | Liasoning with APDCL, Forest Department, Electrical Inspectorate etc. right from start till commissioning of the HT Line/ sub-station, preparation of all necessary documents like Agreement and Affidavit reqd. for power connection, obtaining No Objection Certificate from Forest Department where necessary to complete all arrangement for charging the installation as reqd. and as directed. |
| 75 | Testing and commissioning of the 11KV Line including making necessary inspection fee and obtaining charging approval from competent authority making requisite payment of Inspection Fee to the APDCL/ Electrical Inspectorate, arranging for Test Report etc. as reqd and as directed. upto 1 kM |
| 76 | Erection & Commissioning LT Whole Current Electronic Energy Meter including making necessary payment to APDCL for Meter Cabinet, Meter Security etc as reqd and as directed. |
| 77 | Load Security to be paid to APDCL (Approx.) |
| 78 | LT control panel |
| 79 | L.T. CONTROL PANEL: Supplying, installation, testing& commissioning of indoor type floor mounted, cubicle type compartmental, dust and vermin proof (as per IP-54) main LT Control Panel Board of following capacity and size made out of 16SWG CR sheet and 40mm X40mm X 6mm angle having four nos. of legs 400mm long at the bottom with folded and welded construction having dismantled doors at the back, surface chemically treated and Siemen’s grey powder coated, containing Al. strip Bus-bar having minimum current density of 1.2 Amps/sq.mm, R-Y-B-N colour coded with heat shrinkable insulating sleeves containing all incoming and outgoing electrical accessories as specified, neatly installed and internally wired with best quality multi-strand, PVC insulated single core unsheathed, HRFR Copper Wire( Switch gears above 100Amps rating to be connected to the Bus-bar through Al. strip of suitable size) having cable incoming and outgoing provision at the bottom through gland plates complete including necessary excavation of trench and C.C. Work as directed.1. FP 415V, 63 Amps MCCB with short circuit & overload protection, Breaking capacity 35/36KA-12. TP, 63A, 415V, AC Motor Control Switch (SDF) with 63 A HRC fuse-13. Air Break Contactor, TP, 32A, 415V AC for Capacitor Duty-14.TP, 415V, 32A, MCB for Power Capacitor-15. M.I. Voltmeter (0-500V), 1% accuracy 96 mm X 96 mm size-16. Voltmeter Selector Switch, 4 position, 10/15 A-17. Ammeter Selector Switch, 4 position, 10/15 A-18. Analog Power Factor Meter, 96mm x96mm size 1% accuracy-19. Current Transformer for metering purpose accuracy Class-I, ratio 60/5 A-610. LED Type Pilot Indicating Lamp, 25 mm-311. SP, 250V, 1A MCB with breaking capacity 10 KA for Meter protection -112. Aluminium Bus- bar, 40mm X5 mm -113. On and Off Push Button Switch -1Total Cost of Panel Board |
| 80 | Supplying, fitting, fixing of LT Power Capacitor, 415V, AC, 3 Ph (single unit) of 6KVAR rating and making connection with Bus-bar in the existing panel. The capacitor is to be placed in existing platform. |
| 81 | Supplying, fabrication and erection of Iron Angle Stand for erection of LT Power Capacitor made of MS Angle of size 30 mmX 30mm X5 mm with 4 Nos of legs 400mm high and cross pieces having Bakelite Sheet horizontal platform as directed Size of Frame: 300mm |
| 82 | Supplying including fitting, fixing and connection of TPN Main Switch (SDFU- SwitchDisconnector Fuse Unit) with HRC fuses, 415V AC, Open Execution, Panel Mounting type of following rating in already fabricated Control Panel Board housing , along with lugs, connecting cable and all other necessary materials as directed, 100 Amps |
| 83 | Supplying including fitting, fixing and connection of three pole 415V, AC 50 Hz Motor Protection Circuit Breaker (MPCB) with adjustable thermal and magnetic setting with rotary handle of followingcurrent/HP ratings in already fabricated LT Control Panel Board housing along with lugs, connection cable andall other necessary materials for connection as directed. |
| 84 | Laying of PVC/XLPEinsulated Armoured LT Power Cable 1.1KV grade with Aluminium conductor in open trench/ in air including fitting with necessary necessary clamps etc. in wall/pole /other support as reqd. and as directed.Size of Cable: 35 Sq.mm X3 Core for Starter Connection:a)Cost of Cable |
| 85 | EARTHING:- |
| 86 | Supplying and erection of Pipe Earth Station including supply of all materials with GI Pipe of following size perforated all over the body with 12mm dia hole at standard spacing with necessary reducing socket , locking arrangement with hinge cover plate, funnel, GI nuts& boltsetc with necessary enclosure on the top including excavation and refilling as directed. 40mm dia X2.5 Mtr long GI Pipe along with salt and charcoal |