| 1 | On-site Repair / Maintenance and Servicing of RO/filteration plants by dismantling, checking all parts i.e. Pre-filter, granular activated carbon block filter, membrane, UV disinfection / filtration system, adaptor, pressure pump set, main pump motor, solenoid valve, flow controller, all gauges, filling of anti-scalent liquid, checking functioning of all type meters, electric wiring, contactors & relay, switches, valves and replacement of old unserviceable parts, checking of leakages of any part of plants and pipe line by new parts and pipe line including re-assembling the same as original and reinstalling at same place includingre-connecting with the existing water supply systemand testing at full capacity discharge of filtered water complete all as specified and as directed of the following description :-(a) RO Plant of 25 Ltrs/Hours capacity |
| 2 | (b) RO Plant of 50 Ltrs/Hours capacity |
| 3 | (b) RO Plant of 100 Ltrs/Hours capacity |
| 4 | (e) RO Plant of 2500 Ltrs/Hours capacityNotes for Serial Item No 1 :- (i). Spare parts required for replacement of the defective parts to make the RO Plant fully functional shall be measured and paid separately under appropriate item of this Schedule as \"Supply only\". (ii). The Contractor will ensure that all RO plants are functional throughout the contract period by detailing his technical team once in each quarter though out the contract period for servicing and maintenance. |
| 5 | (iii). In the eventually of any RO plants not working after the last service and before the next service, the contractor will attend the complaint within 72 hours of intimation of the complaint through SMS / e-mail / WhatsApp message from JE (E/M) / AGE (E/M). The Visit charge due to any such complaint shall be deemed to be included in the quoted rates against Serial item No 36 & 37 and nothing extra shall be admissible on this account.(iv). In case the Contractor fails to attend the complaint and does not make the plant serviceable within stipulated time frame of 72 hours, a Panel Recovery of `500.00 per day per plant will be deducted for each day of delay. (v). The Contractor may claim part payment for each quarter as per the work done. Contractor shall produces Job card duly indicating details of parts replaced duly signed by the User Rep, JE (E/M) & AGE (E/M). |
| 6 | Supply only Bib tap 20mm bore standard of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 125 grams), complete all as specified and directed. |
| 7 | Supply only Bib tap 15mm bore standard of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 90 grams), complete all as specified and directed. |
| 8 | Supply only Stop Valve, cast copper alloy, 20mm bore, screweddown, high pressure with crutch or butterfly handle, both ends screwed for iron pipe orfor union etc., complete all as specified and directed. |
| 9 | Supply only Stop Valve, cast copper alloy, 15mm bore, screweddown, high pressure with crutch or butterfly handle, both ends screwed for iron pipe orfor union etc., complete all as specified and directed. |
| 10 | Supply only PVC tubing of 14mm bore, complete all as specified and directed.Make :Renuka/ Kent / Eureka Forbes |
| 11 | Supply only PVC tubing of 12mm bore, complete all as specified and directed.Make :Renuka/ Kent / Eureka Forbes |
| 12 | Repair / Maintenance of feeding Pump of 0.37KW to 0.5HP installed in RO plant at various location by disconnecting of RO plant carefullyfor repair, rewindingwith super enamelled copper winding wire of suitable size, greasing, change of capacitor, bearing etc and reassembling of pump at its original position, complete all as specified and directed. |
| 13 | Repair / Maintenance of Pressure Pump of 1 to 2 HP installed in RO plant at various location by disconnecting of RO plant carefullyfor repair, rewindingwith super enamelled copper winding wire of suitable size, greasing, change of capacitor, bearing etc and reassembling of pump at its original position, complete all as specified and directed. |
| 14 | Supply only Feeding Pump suitable for small water filtration plant of rating 0.37 KW/ 0.5 HP, 230 volts, 50 Hz, Single Phase, 20 meter head and discharge rate 40 LPM, complete all as specified and directed.Make : Crompton Greaves / Kirloskar / Siemens |
| 15 | Supply only Pressure Pump suitable for small water filtration plant of rating 0.75/1.0 KW/HP, 230 volts, 50 Hz, 3 stage& discharge rate 750 LPH, complete all as specified and directed.Make : Crompton Greaves / Kirloskar / Siemens |
| 16 | Supply only Pressure Pump suitable for small water filtration plant of rating 1/1.50 KW/HP, 230 volts, 50 Hz, 5 stageand discharge rate 750 LPH, maximum head 47 meter, complete all as specified and directed.Make : Crompton Greaves / Kirloskar / Siemens |
| 17 | Supply only Pre-Filter (Micronic Filter) candle of following size, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes)(a) RO Plant of 25 Ltrs/Hours capacity |
| 18 | (b) RO Plant of 50 Ltrs/Hours capacity |
| 19 | (c) RO Plant of 100 Ltrs/Hours capacity |
| 20 | Supply only Carbon block Filter of following size, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes)(a) RO Plant of 25 Ltrs/Hours capacity |
| 21 | (b) RO Plant of 50 Ltrs/Hours capacity |
| 22 | (c) RO Plant of 100 Ltrs/Hours capacity |
| 23 | Supply only Media Cylinder/water treatment vessel of following capacity, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes)(a) RO Plant of 25 Ltrs/Hours capacity |
| 24 | (b) RO Plant of 50 Ltrs/Hours capacity |
| 25 | (c) RO Plant of 100 Ltrs/Hours capacity |
| 26 | (d) RO Plant of 2500 Ltrs/Hours capacity |
| 27 | Supply only Membranes of following capacity, complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes)(a) RO Plant of 25 Ltrs/Hours capacity |
| 28 | (b) RO Plant of 50 Ltrs/Hours capacity |
| 29 | (c) RO Plant of 100 Ltrs/Hours capacity |
| 30 | Supply only new Adaptors of following capacity, complete all as specified and directed. (Make : Renuka / Kent/ Eureka Forbes)(a) RO Plant of 25 Ltrs/Hours capacity |
| 31 | (b) RO Plant of 50 Ltrs/Hours capacity |
| 32 | (c) RO Plant of 100 Ltrs/Hours capacity |
| 33 | Supply only ultra violet rays (UV) panel of RO plant, complete all as specified and directed.Make : Renuka / Kent / Eureka Forbes |
| 34 | Supply only ultra violet bulb (UV)for any capacity of RO plant, complete all as specified and directed.Make : Renuka / Kent / Eureka Forbes |
| 35 | Repair / maintenance / replacement of control panel and its parts inclusive paint, making identification marks of all indicators like pressure gauge, Ammeter, Voltmeter etc all defective parts to be replaced and make in serviceable codition all as specified and directed. (Note:- All required replacement of parts in panel will be inclusive in quoted rate of this job. No extra cost of parts will be pay to contractor) |
| 36 | Supply only distributor handle of following capacity, complete all as specified and directed. (Make : Renuka / Kent/ Eureka Forbes / Hi Tech)(a) RO Plant of 25 Ltrs/Hours capacity |
| 37 | (b) RO Plant of 50 Ltrs/Hours capacity |
| 38 | (c) RO Plant of 100 Ltrs/Hours capacity |
| 39 | (d) RO Plant of 2500 Ltrs/Hours capacity |
| 40 | Supply only flow restrictor adjuster of following capacity, complete all as specified and directed. (Make : Renuka / Kent/ Eureka Forbes)(a) RO Plant of 50 Ltrs/Hours capacity |
| 41 | (b) RO Plant of 50 Ltrs/Hours capacity |
| 42 | (c) RO Plant of 100 Ltrs/Hours capacity |
| 43 | Supply only anti-scalant dosing punp with connecting flexible pipe complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes) |
| 44 | Repair / servicing of chemical dosing electric operated at site replacement of unservieable spares ie. NRV, inlet outlet pipe, strainer, foot valve, regulator, indicator switch as required and make in serviceable codition all as specified and directed. (Note:- All required replacement of parts will be inclusive in quoted rate of this job. No extra cost of parts will be pay to contractor) |
| 45 | Supply only micronic shell (Filter housing) of size 20 inch complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes) |
| 46 | Supply only micronic shell (Filter housing) of size 10 inch complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes) |
| 47 | Supply only Anti-scalant Liquid (membrane protector), complete all as specified and directed. (Make : Renuka / Kent / Eureka Forbes) |
| 48 | Supply only elbow for CPVC of 1/2 inch size, complete all as specified and directed.Make : Renuka / Kent / Eureka Forbes |
| 49 | Supply only elbow for CPVC of 3/4 inch size, complete all as specified and directed.Make : Renuka / Kent / Eureka Forbes |
| 50 | Supply only CPVC union of 1/2 inch size, complete all as specified and directed.Make : Renuka / Kent / Eureka Forbes |
| 51 | Supply only CPVC union of 3/4 inch size, complete all as specified and directed.Make : Renuka / Kent / Eureka Forbes |
| 52 | Supply only capacitor of 10 MFD, complete all as specified and directed.Make : L&T / ABB / Siemens / GE |
| 53 | Supply only Solenoid Valve, complete all as specified and directed.Make : Renuka / Kent / Eureka Forbes |
| 54 | Supply only CPVC pipe Adhesive, complete all as specified and directed. |
| 55 | Supply only Taflon Tape for RO, complete all as specified and directed. |
| 56 | Supply & Filling Chlorine Dosing Tank of RO/Filtration plaant of SUPER CHLOR TOTAL a solution of Hypochlorous Acid (HOCL) for chlorination of drinking water disinfection solution having residual effect, clear colour less and potent germicide non corrosive and non foaming stable upto 100 degree C for drinking water as and when required in HDPE jericane of 35 Ltrs capacity having the following features (Make : Renuka Tech) (a) Potent germicide(b) Slime control (c) High residual effect to avoid contaminator (d) Less Hazardous(e) Work at low dosage in post disinfection(f) No after taste.(g) Most reliable in operation(h)Eco friendly and biodegradable |
| 57 | Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed. |
| 58 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed. |
| 59 | Removing excavated soilsto a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 60 | Galvanised iron pipe of the following size medium grade with all fittings such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc. supplied and laid in trenches/on walls / floors / ceilings wih clamps complete all as specified and directedMake : Jindal / TATA / Prakash Tubes |
| 61 | (a) 50mm bore |
| 62 | (b) 40mm bore |
| 63 | (c) 25mm bore |
| 64 | (d) 20mm bore |
| 65 | (e) 15mm bore |
| 66 | Dismantling and refixing the complete unit of unserviceable solar water heaterCapacity 100 LPD plate with new solar water heater plate of the following installed at various sites complete overhauling, cleaning, servicing all serviceable accessories including repairing/ replacing of all defective parts such as copper tubes, toughned glass, hot water tank, nuts, bolts, wasahers and all other minor accessories as required at site including painting to solar water heater by rubbing the old paint and applying with two coats of synthetic enamelled paint by spray painting and testing the same after repair, complete all as specified and directed(Note: Replacement of spares shall be measured and paid for seperately.) |
| 67 | Supply only the following items / spares in replacement for Solar Heaters of various capacities complete all as specified :-(a) Heating element (Electric rod) of capacity upto 2 KW having rubber washer of size 1 ¼” or 1 ½”complete. |
| 68 | (b) Heating element (Electric rod) of capacity upto 1.5 KW having rubber washer of size 1 ¼” or 1 ½”complete. |
| 69 | (b) Glycol (Anti freezing solution) for filling in copper tubes complete. |
| 70 | (c)Toughened glass 6mm thick for collector for heat transmission including making connection |
| 71 | (d) Make up water tank |
| 72 | (e)Coupling gasket |
| 73 | (f)Temp Gauge 0 degree centigrade to 120 degree centigrade |
| 74 | (g) Dead flange with nut, bolts and washers complete. |
| 75 | (h)Float valve assembly 15mm dia complete. |
| 76 | (j) Thermostat suitable for solar heater complete. |
| 77 | Supply and fixing Gun metal globe / gate valve ISI Marked with and including jointing meterial and taking out old unserviceable valves complete all as specified and directed of following sizes :- Make : Advance / Bir / Leader / Sant/ RAMCO |
| 78 | (a) 40mm bore |
| 79 | (b) 25mm bore |
| 80 | (c) 20mm bore |
| 81 | (d) 15mm bore |
| 82 | MCB SP 6 to 32 Amp 10 KA 240 Volts, 50 Hz, \"C\" curve,fixed in repair complete all as specified and directed. (Make : ABB / Siemens / Legrand/ Havells / Scheinder) |
| 83 | MCB SPN 32 Amp 10 KA 240 Volts, 50 Hz, \"C\" curve,fixed in repair complete all as specified and directed. (Make : ABB / Siemens / Legrand/ Havells / Scheinder) |
| 84 | MCB SPN 40-63 Amp 10 KA 240 Volts, 50 Hz, \"C\" curve,fixed in repair complete all as specified and directed. (Make : ABB / Siemens / Legrand/ Havells / Scheinder) |
| 85 | MCB TPN 25 to 63Amp 10 KA 240 Volts, 50 Hz, \"C\" curve,fixed in repair complete all as specified and directed. (Make : ABB / Siemens / Legrand/ Havells / Scheinder) |
| 86 | Sheet metal enclosure factory made single door for DB 240 volts with 200 Amps rated bus bar SPN 4 Way, fixed in repair and making good disturbed surfaces of walls, complete all as specified and directed. |
| 87 | Sub main wiring with two single core PVC insulated multistranded un-sheathed FRLS cable of size 4.0 Sqmm with stranded copper conductor, drawing into PVC ccasing caping of size 20/30mm and accessories) with continuous PVC insulated multistranded unsheathed FRLS cable earth wire of 2.5 Sqmm dia including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Two run of 4.0 Sqmm wire, one run of 2.5 Sqmm wire and one run of PVC casing caping shall be considered as one unit length. |