Housing Urban and Rular Development Government Departments Closing in 0 days TDR #38207079

Proposed Construction Of 8(Eight) Nos. Staff Quarters Building[Type-I Quarter-04 Units (One Block - Twin Double Storey), Type-Ii Quarter-02 Units (One Block-Double Storey) And Type-Iii Quarter-02 Units (One Block Double Storey)] At Kanika Memorial Primary

Issued by Government Departments · kailashahar, Tripura
Tender Value
5.11 Lakhs
Estimated cost
Bid Submission
06 Jul 2023
0 days left
EMD
10223
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kailashahar → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Proposed Construction Of 8 ( Eight ) Nos. Staff Quarters Building [ Type-I Quarter-04 Units ( One Block - Twin Double Storey ) , Type-Ii Quarter-02 Units ( One Block-Double Storey ) And Type-Iii Quarter-02 Units ( One Block Double Storey ) ] At Kanika Memorial Primary Health Center ( Phc ) In Kailashahar Under Unakoti District, Tripura Under Nhm / Sh: Building Portion Including Internal Water Supply And Sanitary Installation, Sewage And Drainage Works. / Sh:- Providing E.I Thereof

BOQ

Name of Work:-Proposed Construction of 8(eight) Nos. staff quarters building[Type-I quarter-04 Units (One block - twin double storey), Type-II quarter-02 units (One block-double storey) and Type-III quarter-02 units (One block double storey)] at Kanika Memorial Primary Health Center(PHC) in Kailashahar under Unakoti District, Tripura under NHM /SH: Building portion including internal water supply and sanitary installation, sewage and drainage works./SH:- Providing E.I Thereof.
Sl. No. Item Description
1Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required:-(As per TSR 2021 Item no-101)
2Short point:-
3Medium point:-
4Long point:-
5Providing and fixing of 3 pin 5/6 amps plug point withpianotype 5/6ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required:-(As per TSR 2021 Item no-103)
6Providing and fixing of 3/6 pin15/16 amps plug point withpianotype 15/16ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required:-(As per TSR 2021 Item no-104)
7Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required(TSR-2021, SL-205)
82 X 1.5 sq mm
92 X 2.5 sq mm
102 X 4 sq mm
11Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- (As per TSR 2021, Sl.no.503)
121 X 2.5 sq mm
131 X 4 sq mm
14Supplying and fixing of the following electrical accessories including necessary connection etc. as required.(As per TSR 2021 Item no-604)
15Electrinic 5 step fan regulator:-
16Ding Dong Call Bell
17Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\"x 12\" having locking arrangement including CC work, holes on earth pipe etc. as required.(As per TSR 2021, SL No:-701)
18Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required.(As per TSR 2021, SL No:-702)
19Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of4.06mm (8SWG) dia G.I./ Copper wire forearth connection from earth electrodes etc as required. (As per TSR 2021, SL No:-710)
20Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.(As per TSR 2021, SL No:-706)
21Providingearthing systemwith maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminalsize 32mmx 6mm including accessories with masonry enclosure of CIcover plate size 12\"x 12\" having locking arrangement including CC works etc as required:- (As per TSR 2021, SL No:-717)
22Supply and fixing of 25mm x 5 mm GI strip on walls/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals.(As per TSR 2021, SL No:-712)
23Supply and fixing of the following sizes GIprongwith necessary nuts & bolts etc as required grouted on roof for Lightning protection.(As per TSR Item 2021 no-716)
24GI Prong 1000 mm long: -
25Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W)(As per TSR 2021 Item no-802)
26Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:-(As per TSR 2021, SL No:-816)
27Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-(As per TSR 2021, SL No:-821)
28Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:-(As per TSR 2021, SL No:-831)
29Supplying and fixing of following luminaries complete withnecessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):-(As per TSR 2021, SL No:-1001)
30Box type single FTL fittings of CRCA steel sheet housing complete with 36/40 W FTL,electronic ballast and high quality reflector cover : -
31Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) : -
32Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-(As per TSR 2021 Item no-1103)
339 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
34Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR 2021 Item no-1101)
35Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:-
36Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-(As per TSR 2021, SL No:-1202)
3732 amps 240 volts DP main switch (rewireable):-
38Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required.(As per TSR 2021 Item no-1208)
392+4/6 way MCB DB (single door):-
402+6/8 way MCB DB (single door):-
412+10/12 way MCB DB (single door):-
42Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required:-(TSR-2021, SL-1215)
436 to 32 amps SP MCB:-
44Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:-(TSR-2021, SL-1217)
4540 amps DP isolator:-
46Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required:-(As per TSR 2021, Sl.no.1502)

AI Tender Summary

OUR REF NO 38207079
AUTHORITY Government Departments
TENDER VALUE 5.11 Lakhs
LAST DATE 06-07-2023
Authority
Authority Name Public Works Department
Work Description Proposed Construction Of 8 ( Eight ) Nos. Staff Quarters Building [ Type-I Quarter-04 Units ( One Block - Twin Double Storey ) , Type-Ii Quarter-02 Units ( One Block-Double Storey ) And Type-Iii Quarter-02 Units ( One Block Double Storey ) ] At Kanika Memorial Primary Health Center ( Phc ) In Kailashahar Under Unakoti District, Tripura Under Nhm / Sh: Building Portion Including Internal Water Supply And Sanitary Installation, Sewage And Drainage Works. / Sh:- Providing E.I Thereof
Basic Detail
Tender No 17/EE-IED/AMB/2023-24
Bidding Type Tender
Location
City kailashahar
State Tripura
Key Dates
Publish Date 16 Jun 2023
Submission Date 06 Jul 2023
Open Date 07 Jul 2023
Finance
Tender Value 5.11 Lakhs
Tender Fee 1000
EMD 10223
Exemption Not Available
Document List
3fca032f-2837-4602-b739-ef917bab414e.html
BOQ_39995.xls
DNIeT17.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 16, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 06, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 07, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

3fca032f-2837-4602-b739-ef917bab414e.html

xls

BOQ_39995.xls

pdf

DNIeT17.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders