Proposed Construction Of 8(Eight) Nos. Staff Quarters Building[Type-I Quarter-04 Units (One Block - Twin Double Storey), Type-Ii Quarter-02 Units (One Block-Double Storey) And Type-Iii Quarter-02 Units (One Block Double Storey)] At Kanika Memorial Primary
Tender Overview
Project Description
Proposed Construction Of 8 ( Eight ) Nos. Staff Quarters Building [ Type-I Quarter-04 Units ( One Block - Twin Double Storey ) , Type-Ii Quarter-02 Units ( One Block-Double Storey ) And Type-Iii Quarter-02 Units ( One Block Double Storey ) ] At Kanika Memorial Primary Health Center ( Phc ) In Kailashahar Under Unakoti District, Tripura Under Nhm / Sh: Building Portion Including Internal Water Supply And Sanitary Installation, Sewage And Drainage Works. / Sh:- Providing E.I Thereof
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required:-(As per TSR 2021 Item no-101) |
| 2 | Short point:- |
| 3 | Medium point:- |
| 4 | Long point:- |
| 5 | Providing and fixing of 3 pin 5/6 amps plug point withpianotype 5/6ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required:-(As per TSR 2021 Item no-103) |
| 6 | Providing and fixing of 3/6 pin15/16 amps plug point withpianotype 15/16ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required:-(As per TSR 2021 Item no-104) |
| 7 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required(TSR-2021, SL-205) |
| 8 | 2 X 1.5 sq mm |
| 9 | 2 X 2.5 sq mm |
| 10 | 2 X 4 sq mm |
| 11 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- (As per TSR 2021, Sl.no.503) |
| 12 | 1 X 2.5 sq mm |
| 13 | 1 X 4 sq mm |
| 14 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required.(As per TSR 2021 Item no-604) |
| 15 | Electrinic 5 step fan regulator:- |
| 16 | Ding Dong Call Bell |
| 17 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\"x 12\" having locking arrangement including CC work, holes on earth pipe etc. as required.(As per TSR 2021, SL No:-701) |
| 18 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required.(As per TSR 2021, SL No:-702) |
| 19 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of4.06mm (8SWG) dia G.I./ Copper wire forearth connection from earth electrodes etc as required. (As per TSR 2021, SL No:-710) |
| 20 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.(As per TSR 2021, SL No:-706) |
| 21 | Providingearthing systemwith maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminalsize 32mmx 6mm including accessories with masonry enclosure of CIcover plate size 12\"x 12\" having locking arrangement including CC works etc as required:- (As per TSR 2021, SL No:-717) |
| 22 | Supply and fixing of 25mm x 5 mm GI strip on walls/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals.(As per TSR 2021, SL No:-712) |
| 23 | Supply and fixing of the following sizes GIprongwith necessary nuts & bolts etc as required grouted on roof for Lightning protection.(As per TSR Item 2021 no-716) |
| 24 | GI Prong 1000 mm long: - |
| 25 | Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W)(As per TSR 2021 Item no-802) |
| 26 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:-(As per TSR 2021, SL No:-816) |
| 27 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-(As per TSR 2021, SL No:-821) |
| 28 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:-(As per TSR 2021, SL No:-831) |
| 29 | Supplying and fixing of following luminaries complete withnecessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):-(As per TSR 2021, SL No:-1001) |
| 30 | Box type single FTL fittings of CRCA steel sheet housing complete with 36/40 W FTL,electronic ballast and high quality reflector cover : - |
| 31 | Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) : - |
| 32 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-(As per TSR 2021 Item no-1103) |
| 33 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 34 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR 2021 Item no-1101) |
| 35 | Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 36 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-(As per TSR 2021, SL No:-1202) |
| 37 | 32 amps 240 volts DP main switch (rewireable):- |
| 38 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required.(As per TSR 2021 Item no-1208) |
| 39 | 2+4/6 way MCB DB (single door):- |
| 40 | 2+6/8 way MCB DB (single door):- |
| 41 | 2+10/12 way MCB DB (single door):- |
| 42 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required:-(TSR-2021, SL-1215) |
| 43 | 6 to 32 amps SP MCB:- |
| 44 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:-(TSR-2021, SL-1217) |
| 45 | 40 amps DP isolator:- |
| 46 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required:-(As per TSR 2021, Sl.no.1502) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender