Proposed Construction Of 24(Twenty Four) Nos Staff Quarter Building At Ratan Moni Ashram School, Kanchanpur, North Tripura/Sh: Construction Of 12(Twelve) Nos Type-I Quarter, One Block, Four Unit At Each Floor G+2 Storied, 12(Twelve) Nos Type-Iii Quarter,
Tender Overview
Project Description
Proposed Construction Of 24 ( Twenty Four ) Nos Staff Quarter Building At Ratan Moni Ashram School, Kanchanpur, North Tripura / Sh: Construction Of 12 ( Twelve ) Nos Type-I Quarter, One Block, Four Unit At Each Floor G+2 Storied, 12 ( Twelve ) Nos Type-Iii Quarter, One Block, Four Unit At Each Floor G+2 Storied. / Building Portion Including Internal Water Supply, Sanitary Installation, Sewage & Drainage Work / Sh: Providinge.I Thereof.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required (As per TSR 2021,sl-101) |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Wiring for 2 way controlling lightpoint with 3 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type 2 way switch including connection etc as required. (as per TSR 2021 Sl.102) |
| 6 | Long Point |
| 7 | Providing and fixing of 3 pin 5/6 amps plug point withpianotype 5/6ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required.(as per TSR 2021 Sl.103) |
| 8 | Providing and fixing of 3/6 pin15/16 amps plug point withpianotype 15/16ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. (as required.(as per TSR 2021 Sl.104) |
| 9 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. (As per TSR 2021,sl-205) |
| 10 | 2 X 1.5 sq mm |
| 11 | 2 X 2.5 sq mm |
| 12 | 2 X 4 sq mm |
| 13 | 2 X 6 sq mm |
| 14 | Wiring for Circuit/Sub-main wiring with the following sizes of PVC insulated copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required.(as required.(as per TSR 2021 Sl.503) |
| 15 | 1 X 1.5 sq mm |
| 16 | 1 X 2.5 sq mm |
| 17 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\"x 12\" having locking arrangement including CC work, holes on earth pipe etc. as required. (As per TSR 2021, Sl.no.701) |
| 18 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. (As per TSR 2021, Sl.no.702) |
| 19 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.(As per TSR 2021, Sl.no.706) |
| 20 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of4.06mm (8SWG) dia G.I./ Copper wire forearth connection from earth electrodes etc as required.(as per TSR 2021 Sl.710) |
| 21 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick i/c accessories and providing masonry enclosure withCIcover plate Size 12\"x 12\" having locking arrangement, alongwith20 mm dia (medium gauge) watering pipe including CC work etc as required. (as per TSR 2021 Sl.704) |
| 22 | Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required. (as per TSR 2021 Sl.705) |
| 23 | Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. (as per TSR 2021 Sl.712) |
| 24 | Supply and fixing of 32mm x 6 mm GI strip on walls/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. (as per TSR 2021 Sl.713) |
| 25 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.( As per TSR 2021 Sl-602) |
| 26 | 19/20 mm dia |
| 27 | Supply and fixing of the following sizes GIprongwith necessary nuts & bolts etc as required grouted on roof for Lightning protection.(as per TSR 2021 Sl.716) |
| 28 | G.I Prong 450 mm long |
| 29 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required.(as per TSR 2021 Sl.604) |
| 30 | Electronic 4 Step Fan Regulator |
| 31 | Musical call bell. |
| 32 | 32 amps DP kit kat switch. |
| 33 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-(As per TSR 2021,sl-1202) |
| 34 | 32 amps 240 volts DP main switch (rewireable):- |
| 35 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required.(As per TSR 2021,sl-1208) |
| 36 | 4 way SPN MCB DB (single door): |
| 37 | (2+6) / 8 way MCB DB (single door). |
| 38 | (2+10) / 12way SPN MCB DB (single door). |
| 39 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required:-(As per TSR 2021,sl-1215) |
| 40 | 6 to 32 amps SP MCB |
| 41 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:-(As per TSR 2021,sl-1217) |
| 42 | 40 amps DP isolator:- |
| 43 | Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W)(As per TSR 2021 Item no-802) |
| 44 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required. (as per TSR 2021 Sl.817) |
| 45 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required. (as per TSR 2021 Sl.821) |
| 46 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required. (as per TSR 2021 Sl.831) |
| 47 | Supplying and fixing of following luminaries complete withnecessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours). (as per TSR 2021 Sl.1001) |
| 48 | Box type single FTL fittings of CRCA steel sheet housing complete with 36/40 W FTL,electronic ballast and high quality reflector cover. |
| 49 | Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) |
| 50 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required. (as per TSR 2021 Sl.1103) |
| 51 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink . |
| 52 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR 2021,sl-1101) |
| 53 | Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser. |
| 54 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt).(as per TSR 2021 Sl.1102) |
| 55 | 60 watt LED street light fixture with integral driver and secondary lens (IP 66). |
| 56 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required. (as per TSR 2021 Sl.1501) |
| 57 | 40 mm dia. |
| 58 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering,shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) (as per TSR 2021 Sl.1509) |
| 59 | Neat cement punning . (as per TSR 2021 Sl.1522) |
| 60 | Supplying & installation of astronomical time switch including necessary connection etc as required.(as per TSR 2021 Sl.1513) |
| 61 | Supplying & installation of following power contactors including necessary connection etc as required. (as per TSR 2021 Sl.1514) |
| 62 | 3 pole 9 amps (AC3)power contactors with 1NO+1NC Aux. Contact. |
| 63 | Supplying and laying of the following XLPE insulated PVC sheathed alluminum armoured cable including connection etc as required. (as per TSR 2021 Sl.1301) |
| 64 | 3 core4 Sq mm. |
| 65 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable. (as per TSR 2021 Sl.1405) |
| 66 | 1.5 sqmm - 4 sqmm Cable. |
| 67 | Drawing of armoured/un-armoured cable with proper saddling etc as required. (as per TSR 2021 Sl.1511) |
| 68 | Supplying of 25 cm long ‘L’ hook made with 40mm x 6mm MS flat and fixing with necessary fasten nuts including finishing, painting etc as required.(as per TSR 2021 Sl.1508) |
| 69 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required:-(As per TSR 2021, Sl.no.1502) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender