}

Tender For Repairs And Maintenance Of Sanitary Workers Living Room At Thiruneermalai In Tcmc Zone-1, Chengalpattu-Tamil Nadu

Pammal Municipality-agecode007 has published Tender For Repairs And Maintenance Of Sanitary Workers Living Room At Thiruneermalai In Tcmc Zone-1. Submission Date for this Tender is 21-06-2023. Labour Work Tenders in Chengalpattu Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

38206660
Tender For Repairs And Maintenance Of Sanitary Workers Living Room At Thiruneermalai In Tcmc Zone-1
Open Tender
Indian
Tamil Nadu
Chengalpattu
21-06-2023

Tender Details

Repairs And Maintenance Of Sanitary Workers Living Room At Thiruneermalai In Tcmc Zone-1

Key Value

Document Fees
Refer document
EMD
INR 5500.0 /-
Tender Value
INR 5.50 Lakhs /-

BOQ Items

Name of work: Repairs and Maintenance of Sanitary Workers Living Room at Thiruneermalai
Sl. No. Item Description
1Dismantling, clearing away and carefully stacking materials useful Floor finish and dadooing walls in Cement Mortar with mosaic tiles/ glazed tiles/ cuddapah slabs.
2Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Municipal Engineer before use on work.
3Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification.
4Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good for PVC Open light point / Fan point (For Electronic regulator) etc, complete as per standard specifications. SD 22
5Supply and fixing 18W 4 Feet LED Fitting with LED complete with Electronic ballast and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting etc, complete as per standard specificationsSD 87
6Wiring with 2 x 4sqmm (56 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for15A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire for Open PVC power plug point.SD 41
7Wiring with 2 x 4sqmm (56 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for5A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire for Open PVC power plug point.SD 135
8AC Ceiling Fan complete 1200 mm (48") Sweep with 300mm Down Rod and Regulator( 1366+232.60) including Cost and conveyance of charges etc, complete as per standard specifications.
9Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coatincluding the cost all materials etc.,complete, in all floors.
10Paintingwith Ready Mixed Enamel Paint over the new wood works of approved quality and colour without priming coatincluding the cost all materials etc.,complete, in all floors.
11Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rebate for housing the shutter.
12Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights. The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc. The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147. Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer
13Supply , delivery and fixing of following items
1420mm dai PVC Tap
1532mm dia PVC Pipe
1632mm dia PVC Coupling
1732mm dia PVC Elbow
18Reducer 32mmx25mm
1925mm dia PVC pipe
2025mm dia PVC Coupling
2125mm dia PVC Elbow
2225mm dia PVC End Cap
231000 Liter Syntex tank
2432 mm Dia Ball Valve
25Provision for letter writing front side of building including painting cost labour cost all other materials etc complete.
26Supplying and laying Rubberised interlocking Paver blockM40 grade 80mmthick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with stone dust cushion below the uniform shap of approvednon skitting surface in the top and the rate including levelling the base preparation ofpavers as sub base, stone dust cushion 150mm thick layingout of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail