Tender For Repairs Replacement Of Ceiling Exhaust Fans Hot Water System With Connected Works And Summer Appliances Under Ge (C) Bangalore, bangalore-Karnataka

Military Engineer Services-MES has published Tender For Repairs Replacement Of Ceiling Exhaust Fans Hot Water System With Connected Works And Summer Appliances Under Ge (C) Bangalore. Submission Date for this Tender is 03-07-2023. Electrical Maintenance Tenders in bangalore Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

38194880
Corrigendum : Tender For Repairs Replacement Of Ceiling Exhaust Fans Hot Water System With Connected Works And Summer Appliances Under Ge (C) Bangalore
Open Tender
Indian
Karnataka
bangalore
03-07-2023

Tender Details

Repairs Replacement Of Ceiling Exhaust Fans Hot Water System With Connected Works And Summer Appliances Under Ge (C) Bangalore

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Jun-2023 CORRIGENDUM TO TENDER BOQ BOQ 26-06-2023
2 26-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 91500.0 /-
Tender Value
INR 45.75 Lakhs /-

BOQ Items

Name of Work:REPAIRS /REPLACEMENT OF CEILING/ EXHAUST FANS HOTWATER SYSTEM WITHCONNECTED WORKS &SUMMER APPLIANCES UNDER GE (C) BANGALORE
Sl. No. Item Description
1Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc.
2Point Wiring with 1.5 Sqmm (Nominal Area) PVC insulated unsheathed 1100 Volts Grade Stranded Copper Conductor Cable (Red Colour Cable for Phase and Black Colour Cable for Neutral), laid in and including PVC Casing and Capping with Accessories (size of Casing and Capping as required at Site) including 1.50 Sqmm PVC ins-ulatedStranded Copper Conductor Cable (Green Colour) as Earth Continuity Conductorand connected to Common Earth Dolly or as directedand MS terminal box with 3mm thick masonite laminated sheet top cover fixed on Wallfor one light and fan point controlled by one switchcomplete all as specified and as directed for One light /fan point controlled by one 5 Amps switch one way
3All sameas per itemNo 2 here-in-above but One 3 pin socket point 5 Amp on independent board
4All sameas per itemNo 2 here-in-above butOne 3 pin socket point 5 Amp on same board with other switches.
5All sameas per itemNo 2 here-in-above but with 2.5 sqmm ( Nominal area ) cable with 2.5 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
6M&L, Switch piano, flush button single pole, 5 Amps one way
7S&F Switch socket combination flush type 5 Amp 2 in 1
8S&F Switch socket combination flush type 5/16 Amps5 in 1
9Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC square blocks.
10S&F in replacement of sheet metal enslosure single pole and neutral with a two pin & earth plug and socket complete with 1 single pole MCB20 Amps "C" series 10 KA breakingcomplete all as specified and directed. Make- Legrend/Standard/Havells.
11S&F in replacement of metal clad plug top protected type 20 Amps 230 volts complete all as specified and directed. Make-Std/Havells/Bajaj
12S&FLED tube light fitting Mirror type ,2 Feet of10 watts, 230 volt, withaluminium extruded channel powder coated with diffuser for glare free light complete with wall mountingall fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Shakti/Crompton Greaves/Bajaj
13S&F in replacement LED tube light fitting of20 watts 6000K , 230 volt, withaluminium extruded channel powder coated with diffuser for glare free light complete with wall mounting all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm with all as specified and directed by Engr-in-charge. Make : Shakti/Crompton Greaves/Bajaj
14Taking down old existing sub main wiring and provide new submain wiring with 2 runs of 6 Sqmm single core PVC insulated, unsheathed, multi strandedcopper conductor and one single core 6 Sqmm PVC insulated , unsheathed , multi strandedcopper cable as earthing lead as per IS : 694 / 1990 drawn through and includingnon-metallic PVC rigid conduit/casing caping of size as orderedin walls / ceilings etc with all accessories such as Tees, Elbows, junction box, reducers etc and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note :- 2 runs 2.5 Sqmm cable , one run2.5 Sqmmcableand one run of PVC Conduit /Casing caping shallbe measured as oneunit length) .
15Allas per itemNo 14 here-in-above but 2 runs with 4 Sqmm single core cable and 4 Sqmm single core as earth contunity wire -do-. (Note :- 2 runs 4 Sqmm cable , one run4 Sqmmcable and one run of PVC Conduit/Casing capingshallbe measured as oneunit length)
16REPAIR TO CEILINGFAN : Taking down ceiling/exhaust fan dismantling and painting ofceiling/exhaust fan complete at site with synthetic enamel paint by spraying incl (fittings with filler) one coat after cleaning all dust etc incl connecting up.Provn of twin core cable of suitable size for ceiling rose to connector connecting of earth wire incl replacement of fan capacitor 2.5/3.15 MFD,canopy, bearing/bush, rubber bushes minor nuts bolts screws washers greassing in fan bearing & refix same complete all as directed
17Rewinding of ceiling fan 1200/1400mm sweep with super enameled copper wire of existing specification, guage and weight including insulating material all as directed by Engr-in-Charge
18Supply & fix in replacement fan capacitor 2.5 MFD including necessaryconnection all as directed.
19Supply & Fix in replacement U clamp with rubber reel insulator with nuts bolts of size 10mm dia 75mm long including necessary washer and split pin.
20Supply & Fix in replacement ceiling fan hook any shape&size including nuts, bolts and rubber reel. angle,
21M&L for overhauling of ceiling fan of any make and sweep including dismantling, cleaning internally and externally and oiling, greasing, checking of electric connection.Replacement of worn out check nuts, split pins, nut,bolts,washers, socketsfan capacitor 2.5/3.15 MFDandetc including assembling and testing complete all as specified and directed.
22REPAIR TO EXHAUST FAN : Rewinding motor of exhaust fan 450 to 200 mm sweep with supr enamelled copper wire of existing specification, guage and weight including insulating material all as directed by Engr-in-Charge.
23Supply & fix in replacement ball bearing of existing exhaust fan suitable for 450 to 200 mm sweep including necessary greasing all as directed. Make : SKF/NBC/Norma
24Supply & fix in replacement mounting legs with rubber suitable for any type of exhaust fan.
25REPAIR TO GEYSER :Taking down of storage water heaterany capacity, type any, make (Geyser) of any size 50/35/25 ltrs capacity from existing position by disconnecting from water supply pipe line and electric connection mains to carryout necessary repairs or to deposit to E/M store yard as directed including refixing on same position after repair and making electric/water connections complete all as specified and directed by Engineer-in-Charge.
26M&L for opening of storage water heater any size/make and taking out inner tank from the geyser body brazing inner tank with suitable welding rod, testing of inner tank for leakage under water pressure after brazing, reassembling geyser including repair/replacement of worn out rubber gasket nuts,bolts and testing complete and refixing in original position as specified and directed by Engr-in-Charge.
27S&F in replacement 2 KW, 230 volts AC of Heating elementfor geyser any capacity, type any make(Round head, or Triangular head type (,Big, small,Medum )as per types requirement at site) including rubber gasket/washer (ISI marked) complete as specified and as directed. Make: All Models of Bajaj l / Havells /Racold / venus / shakthi .Note : As per at site requirement.
28S&F in replacement 1.5 KW, 230 volts AC of Heating elementfor geyser (Round head, or Triangular head type (,Big, small,Medum ) as per types requirement at site) including rubber gasket/washer (ISI marked) complete as specified and as directed. Make: All Models of Bajaj l / Havells /Racold / venus / shakthi .Note : As per at site requirement.
29S&F geyser packing rubber for fixing inlet and outlet complete all as specified and directed.
30S&F in replacement of stud bolt with nuts and washers set of three by brazing on inner tank of geyser complete all as specified and directed.
31S&F in replacement of Thermostat/auto cut off chromium plated brass ends9 / 11 inch in lenth desinged to controlling the temperature ofstorage water heater(Geyser) to any type single phase 230 V all as specified .
32S&F in replacment of indicator lamp red and green (round/rectangular shape )suitable for any type & any size of geysers complete all as speified and directed.
33S&F in replacement of 450 to 600 mm long PVC connection pipefor HOT & COLD water supply with chromium plated brass screwed nuts at bolt ends with washers for making water connections for storage water heater(Geyser) to GI pipe 15mm complete as directed .
34S&F in replacement of 600 to 900 mm long PVC connection pipefor HOT & COLD water supply with chromium plated brass screwed nuts at bolt ends with washers for making water connections for storage water heater(Geyser) to GI pipe 15mm complete as directed .
35Supply & replacement of existing u/s bottom cover of the geyser in two halfs.
36Supply & replacement of GI hexagonal nipple 15mm long 15mm dia.
37Supply & fix in replacement Plug top 3 pin 15 Amps ISI marked. Make- Anchor/KONA/Kinjal/Plaza
38Supply and fix in replacement hanger bolt 100mm long and 12mm dia for mounting of geyser
39Remove the unserviceable cooling appliances from the position, transportation only from the site/store to the contractor work shop for replacement of compressor, cooling coil & painting and repair work and refixing the same after repair at the same location all as per direction of Engr-in-Charge for the following :-Window type AC upto 2.0 Ton capacity.
40All sameas per itemNo 39 here-in-above but Split type AC upto 2.0 Ton capacity.
41All sameas per itemNo 39here-in-above but Water cooler upto 150 ltrs capacity.
42All sameas per itemNo 39here-in-above but Refrigerator upto 400 ltrs capacity.
43All sameas per itemNo 39here-in-above but Deep Freezer upto 400 ltrs capacity.
44Disconnect the suction and discharge refrigerant line to the unserviceable compressor, and replace with the new one compressor brough from the factory of the same make and capacity, connect the refrigerant lines, system fusing, vacummising of the entire system arrest all leakages incl M&L charging of required quantity of refrigerant gas adjusting all connected parts, testing and commissioning for Window/Split type AC upto 2 ton capacity.
45All sameas per itemNo 44 here-in-above but Water cooler 150 ltrs capacity
46All sameas per itemNo 44 here-in-above but Water cooler 60/120 Ltrs capacity
47All sameas per itemNo44here-in-above but Water cooler 40/80 Ltrs capacity
48All sameas per itemNo 44 here-in-above but Refrigerator 310/320 Ltrs capacity
49All sameas per itemNo 44here-in-above but Refrigerator 200/280 Ltrs capacity
50All sameas per itemNo 44 here-in-above but Refrigerator 180/185 Ltrs capacity
51All sameas per itemNo 44 here-in-above but Deep Freezer 205/320 Ltrs capacity
52Removing and replacement of blower motor/fan motor of the same make and capacity, connection and testing etc all as per specified and directed for Window type AC upto 1.5 Ton capacity
53All sameas per itemNo 52here-in-above but Split type AC upto 2 ton capacity
54All sameas per itemNo 52 here-in-above but Water cooler upto120/150 Ltrs capacity
55All sameas per itemNo 52here-in-above but Water cooler upto 40/80 Ltrs capacity
56Servicing and maintenance of window type AC/Split AC including compressed air wash, rearranging of wires, studs or evaporator washingto condenor cooling coil/evoporator cooling coil. Air filter, front grill and make the system functional
57Replacement of unserviceable selector switches rotary type of AC upto 2 ton capacity
58Removing the UNSV running capacitor of 40 MFD, supply and fix of running capacitor 40 MFD suitable for 1.5 ton AC make : BHEL or equivalent.
59All as per item No 58 here-in-before, but starting capacitor of 60/80 MFD for water cooler
60All as per item No 58 here-in-before, but starting capacitor of 80/100 MFD for 1.5 TR/2.0 TR AC.
61Replacement of unserviceable thermostate from the cooling appliances Window type AC/Split type AC upto 2.0 Ton capacity
62All sameas per itemNo 61 here-in-above but Water cooler upto 150 Ltrs capacity
63All sameas per itemNo 61here-in-above but Refrigerator upto 310/320 Ltrs capacity
64Dismantle the unserviceable condenser coil, replace new condenser cooling coil for cooling appliances including system fusing vacumising and M&L of gas and charging testing and commissioning as directed for Window type AC upto 1.5 Ton capacity
65All sameas per itemNo 64 here-in-above but Refrigerator upto 310/320 Ltrs capacity
66All sameas per itemNo 64 here-in-above but Deep freezer upto 205/320 Ltrs capacity
67Remove unserviceable fan blade from the condenser cooling motor replace new fan blade of same and type for Water cooler any type
68All sameas per itemNo 67 here-in-above but Window type AC any type
69Remove unserviceable relay box any type and capacity from refrigerator and supply and fix new relay of same make & type
70Servicing/maintenance (at site) of the refrigerator checking complete wires, reconnect cleaning with compressed air to cooling coils, condenser water wash to the internal cabin of refrigerator all as directed by Engineer-in-Charge
71All same as per item No 70 here-in-above but for water coolers any size any type .
72All same as per item No 70here-in-above but for Deep Freezer any size any type.
73Replacement of push tap of same make & type chromium plated
74Replacement of unserviceable float valve of any make 15mm dia
75Replacement of unsericeable PVC flexible pipe inlet 16mm outer dia and 450 mm long with brass nuts & bolts
76Replacement of plug top 16 Amps suitable for water coolers/Refrigerator /Deep Freezer
77Removing and replacement of unserviceable supply cable to the cooling appliances PVC insulated 3 core cable 1.5 sqm multi stranded copper conductor
78Material and labour for body repairs by fabrication and painting to cooling appliances on already painted surfaces incl prepared with two coats of synthetic enamel over a coat of primer after scraping and rubbing the old painted surface all as specified and directed forWater cooler 150 Ltrs capacity
79Material and labour for body repairs by fabrication and painting to cooling appliances on already painted surfaces incl prepared with two coats of synthetic enamel over a coat of primer after scraping and rubbing the old painted surface all as specified and directed forWater cooler 40/80 Ltrs capacity
80Material and labour for body repairs by fabrication and painting to cooling appliances on already painted surfaces incl prepared with two coats of synthetic enamel over a coat of primer after scraping and rubbing the old painted surface all as specified and directed forDeep freezer upto 320/400 Ltrs capacity
81Remove and replacement of unserviceable thermostat for refrigerator/deep freezer
82Remove and repalcement of unserviceable freezer complete incl M&L of gas and charging etc complete all as specified and directed
83Remove and replacement of over load protection for any type of refrigerator/window AC/Split Each AC/Deep Freezer
84Supply and fill R-134 in cylinder for domestic cooling appliance.
85Removing the UNSV voltage stabilizer from position, open the outer covers, removing the burnt out winding from the transformer and rewinding with super quality insulated copper winding wire of suitable size and insulating properly incl replacement of boost buck relays, assembling the stabilizer complete and fixing back in original position and testing and commissioning for 1 KVA capacitiy :-
86All sameas per itemNo 85 here-in-above but 2 KVA
87All sameas per itemNo 85here-in-above but 3 KVA
88Taking out the UNSV sensor/remote unit completely and supply and fix in sensor arrangement/remote unit to suit the following makes carrier/Blue star/voltas for 1.5 Ton Split type AC :-
89All sameas per itemNo 88 here-in-above but 2.0 Ton Split type AC.
90Removing the damaged/unserviceable refrigerator magnetic gasket of door and replacing with new door gasket of same type and size incl making good the surfaces for proper sealing of the door for 165/286 ltrs capacity.
91All sameas per itemNo 90 here-in-above but286/310 ltrs capacity.