Water Resources and Irrigation Government Departments Closing in 0 days TDR #38194635

Solar Powered Mdtws (4 Pts) At Abhayapuri South (Sc) Lac Under Ridf-Xxviii(Nabard) For The Year 2022-23 Under Abhayapuri South-Bilashipara East Division(I), Abhayapuri

Issued by Government Departments · abhayapuri, Assam
Tender Value
1.18 Crore
Estimated cost
Bid Submission
04 Jul 2023
0 days left
EMD
2.36 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
abhayapuri → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Solar Powered Mdtws ( 4 Pts ) At Abhayapuri South ( Sc ) Lac Under Ridf-Xxviii ( Nabard ) For The Year 2022-23 Under Abhayapuri South-Bilashipara East Division ( I ) , Abhayapuri

BOQ

Name of Work:Solar powered MDTWS (4 Pts) at Abhayapuri South (SC) LAC under RIDF-XXVIII(NABARD) for the year 2022-23 under Abhayapuri South-Bilashipara East Division(I), Abhayapuri.
Sl. No. Item Description
1Construction Approach Road(Qnty. for 4 Pts)
2Item No. 1: Earthwork in filling in Marginal bund / Guide bank / Afflux bund / Canal embankment etc. to the design section and grade by obtaining earth from outside borrow pits and filling in uniform layer not exceeding 15cm thick including clearing light jungle, removing trees upto 15 cm dia and uprooting roots and stumps from the seat at embankment and borrow pit area, breaking clods not more than 10mm cube, ramming, watering, dressing and roughening the seat of embankment, profiling etc. Paying compensation of earth borrowed from private or forest land if any, lead upto 30 M and lift upto 1.5 M complete as directed.A) Ordinary soil
3Item No. 2 : Collection and supply of sand and gravel (40% sand and 60% gravel) of size 13mm to 38mm from approved quarry including loading, unloading and stacking in measurable stacks at work site up to a height of 1.00m including payment of forest royality etc.
4Item No.3:- Carriage of boulders, gravels, metel screening, stacking in measurable stacks at site complete as directed.A) For 1st KM of quarry road
5B) For normal Road up to 25 KM
6Item No. 3: Labour charge for spreading hard river shingles/sand gravels to required thickness over approach subway etc including ramming, dressing the seat before laying the materials lead up to 30M and lift 1.5M complete as directed.
7Boring and Installation of Tube Well (Qnty. for 4 Pts)
8Item No. 1 : Movement of drilling Rig , Tools & Plants, Accessories including drill pipes, casing pipes etc. to drilling site and back.
9Item No. 2 : Boring of DTW of bore hole up to 450mm dia and up to a depth of 70 M or up to required depth by RC/DR Drilling Rig including supply and transportation of all required tools & Plants, materials & labour to site to perform the job in complete as directed in alluvium areas ( means areas where the strata comprises of loose, unconsiolidated materials like clays, silts, sands gravels, pebbles, cobbles and boulders) as per IS:2800 (part-1) of 1991. ( soil sample must be collected & keep properly at every 3.00 M interval of depth in boring. The job also include movement of rig by making temporary approach road etc. to the field up to distance of 1000M)
10Item No. 3 : Supply, lowering & installation in tube well 200mm PVC housing pipe / blind pipe of wall thickness of 10.0 mm to 11.2 mm for casing assembly including supply of well cap, sockets, reducer, MS housing clamps etc. as required as per IS : 12818-1997 of length 3.00 M of Departmental Empanelled Brand &as directed.( Litholog Assembly diagram must be approved by Engineer-in-Charge of the work prior to installation)
11Item No. 4 : Supply, lowering & installation in tube well 200mm PVC Ribbed Screen Filter pipe of wall thickness of 10.00 mm to 11.2mm for casing assembly including supply of sockets, reducer etc. as required as per IS : 12818-1992 of length 3.00 M/2.00 M of Departmental Empannelied Brand and as directed.
12Item No. 5 : Shrouding the DTW assembly by river pea gravel of size 4 mm to 8 mm free from sand / dust and any other foreign materials after screening / stacking at site including supply, transportation, labour etc. complete as directed. (Additional pea gravel required if any during development may be extra subject to due approval from the ordering authority).
13Item No. 6 : Developing the tube well assembly by Air-Compressor of capacity 8-12 kg/cm2 and CFM=450 M3/min so as to get sand free discharge of water with supply of all required materials at site complete as directed including furnishing of litho-log / draw down data etc. as per IS : 11185 of 1999. ( For new DTW minimum 72 hours development is compulsory. Additional pea gravel required if any, during development would be extra )The following data should be reflected in the report of development1. Static water level2. Drawdown at various discharge3. Available average discharge
14Item No. 7: Supply & Installation of Solar Pumping System: (a) Solar Submersible Standalone Pump set with 7.5 HP AC Induction motor and Solar Power Controller Unit ( Conform IEC 6168311:1999) with overload, over-under voltage, short circuit protection, suitable for 200 mm bore well and discharge capacity approx 1400 LPMat10 M head (Dynamic Head Range 10-20 Mtr and Shut off head 30 M) working at 8000 Wattpof solar power along with Cables, Inverter external box, surge suppressor, DC MCB & all necessary accessories like, 2(two) pairs of Assembly support clamps, 10(ten) nos. of Cable clamp / clip, 1 (one) no. of Delivery bend, 20(twenty) mtr. column pipe, 1(one) no. of Short pipe of 1.5 Mtr. length of required diameter, 40(forty) mtr.(approx.) Flat flexible cable (motor to controller) as per latest MNRE norms and as per IS. (b) Supply, fitting-fixing and testing & commissioningof Solar PV modules conforming to IEC 61215 specification or equivalent National or International standards consisting of solar panels framed in anodized aluminium frame of 8000 Wp (approx.) considering 7.15 kWh/ M2/ Day of solar insolation under standard test condition on horizontal surface with tolerance (+/-) 15% and hot dipped galvanized(minm 80 micron thickness) mounting mild steel structure of rectangular hollow sections, angles, heavy duty pipes of dia 150 mm (all materials duly IS marked ) for providing sufficient strength with dual axis manual tracking arrangement which can withstand load of modules and high wind velocities upto 150 Km/hr including RCC foundation designed against all possible loads (Dead, Live and imposed load), Controller conform to IEC 61683–1999 & IEC 60068-1-2, IEC 60068 – 2- (2, 14, 30, 78) ( The series and parallel combination of Solar Modules to be done in such a way that Jalverter/ Controller input voltage requirement is met i.e. System Vmp> 587 V &System Voc< 800 V) and necessary connection cables, pipes to the water trough and other accessories, etc. complete in all respect as directed (Controller to be installed with suitable arrangement on the body of the pole of mounting structure with rain proof provision. SPV panel should be of reputed make like TATA/Bikram/ Waaree etc. and carry at least 20 years warrenty&comprehensive maintenance for 1 year and should installed preferably above HFL) (c) Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. Below the ground level as below: (a) By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanized (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. (d) Lightning protection (Arrestor)(pole mounted)(: Lightning protection with 3\" X 1.5\" G.I pipe of 4 mts. height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia. 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia. 6 mm thick GI base plate at bottom incl. necessary holes etc. including supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the/Roof with GI Saddles 1100 mm apart.
15Item No. 8 : Supply, fitting-fixing of Heavy duty CIDF sluice valve inside screw, non raising, vertical spindle type with hand wheel operation need of water purpose. The rotation of closing should be counter clock wise. The holes of the flange should be drilled as per BSS No. 10 , Part-I, Table-D. All materials construction and components should strickly conform to IS : 14846-2000 and having marked with manufacturers name and trade mark in the delivery pipe layout as directed / as per drawing along with HD GI flange, pipe joining materials and painting in complete as directed.(i) 100mm dia
16Item No. 9 : Supply, fitting-fixing of Heavy duty CIDF Reflex valve, swing check type with bypass arrangement, horizontal operating. The holes of the flange to be as per BSS No. 10, Part-I, Table-D and the material, construction and all components should strictly conform to IS : 5312 (Part-I)-2004 and having arked with manufacturers name and trade mark in the delivery pipe layout asdirected / as per drawing along with HD GI flange, pipe jointing set and painting in complete as directed.(i) 100mm dia
17Item No. 10 : Supply, fitting-fixing of delivery pipes of 80/100 mm dia GI / fabricated GI pipes ( HD of repute brand with ISI marked) with flange at both end / wherever required with pipe jointing sets, including painting in complete as per drawing / specification including temporary pipe support as required and as directed.
18Item No. 11 : Ftting-fixing of MS / GI bend of 150mm dia x 450 / 900 / 1200 with GI / fabricated GI pipes with flange at both end and pipe jointing sets, including painting as per drawing / specification as directed.
19Item No.12:-Supply of GI Equal Tee of 80/100 mm dia complete as directed.
20Item No.13:-Fitting, Fixing of G.I. equal Tee of 80/100mm dia complete as directed.
21Item No. 14 : Supply, fitting-fixing of surge tank of size 900m dia x 1250mm long made of 4mm MS plate with raiser assembly of size 75mm dia x 6.0m long and S-band of size 200mm x 1600mm long made of 4mm MS plate including painting the above with one coat of synthetic enamel primer fllowed by 2 (two) coats of successive synthetic enamel/ bituminous black paint and made provision for mounting the surge tank on a specified foundation by nuts & bolts of suitable size as per drawing & specification as directed.
22Underground PVC Pipe Distribution System (Qnty. For 4 pts)
23Item No. 1: Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
24Item No. 2 : Supplying, fitting, fixing PVC Pipes (IS 12818, 6 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).a) Main line160 mm dia
25b)Branch line 110mm dia
26Item No. 3 : Supplying, fitting, fixing PVC unequal tee joining with pipes with solvent cement, testing leakages etc. complete as directed.Size 160 mm x 160 mm x 110 mm
27Item No. 4 : Supplying, fitting, fixing PVC reducer joining with pipes with solvent cement, testing leakages etc, complete as directed.Size 160 mm x 110 mm
28Item No. 5 : Supplying, fitting, fixing, 110mm dia NTP valve at the top of PVC rising pipe of spout chamber as per specification includinglocal carriage, testing leakage etc.complete as directed.Size : 110mm
29Construction ofSpout Chamber (Qnty.for 4 pts. @ 7Nos./Pt.)
30Item No. 1 :Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
31Item No. 2 :C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
32Item No. 3 : 1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. (In proportion 1:4)
33Item No. 4 : 12 mm cement plastering including clearing surface and curing complete as directed. In prop. 1: 4
34Item No. 5 : Supplying, fitting, fixing 110 mm dia PVC Rising pipe from the toe of main line includinglocal carriage, testing leakage etc.complete as directed.
35Item No. 6 : Supplying, fitting, fixing PVC bend pipe sizejoining with pipes with solvent cement,testing leakages etc. complete as directed.110 mm / 900
36Item No. 7 : Supplying, fitting, fixing PVC Pipes (IS 12818, 4 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).110mm dia
37Construction of Boundary Wall(Qnty. for 4 pts)
38Item No. 1 : Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
39Item No. 2: Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing. Flat brick soling
40Item No. 3 :C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid.separately).i) wall post ii) Gate post
41Item No. 4 : R.C.C work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:2:4 (M15) with hard river shingles of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering, scaffolding etc. where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).i) wall post ii) Gate postiii) Tie beam
42Item No. 5 : Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).(a) Shuttering (Column)
43(b) Shuttering (Beams) with out props ,Tie beam
44Item No. 6 : 1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete.(a) In proportion 1:4i)Tie beam
45Item No. 7 : 12 mm cement plastering including clearing surface and curing complete as directed. In proportion 1:4i)Gate postii)Wall
46Item No. 8 : Supplyingfitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed.10mm dia.
47Item No. 9 : Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 40mm x 40mm x 6mm M.S. angle and with M.S. flat of 40mm x 6mm size as per approved design.Necessarylocking arrangement for temporary closing the gateand 2nos.( minimum) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embedded in C.C brick pillers as necessary including a red oxide painting to all iron works as directed and specified.(Separate payment will be made for posts).
48Construction of supporting pillars (For 4Pts)
49Item No. 1: Earth work in excavation of foundation of canal structures in all types of soil as per design and drawing dressing the foundation, shoring, etc. removing the surplus spoils by head load to a safe distance from the working place and depositing required spoils in uniform layers dressing, watering, breaking clods to not more than 10mm cube with compaction complete as directed at site (including bailing out stagnant water where necessary). a. All type of soil except soil mixed with gravel and bouldersFor normal lead of 30m and lift of 1.50m
50Item No. 2 : Soiling in foundation floor at all levels including filling interstices,ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
51Item No. 3:C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
52Item No. 4 : R.C.C. work in slab, abutment cap and above abutment, pier cap,pedestals, dirt wall etc.in proportion 1:2:4 with hard broken stone aggregateof size 6mm to 20mm with proper reinforcement as per designincluding necessary curing etc. complete as directed with necessary timber shuttering ,scaffolding etc. where necessary complete as directed.( shuttering, scaffolding will be paid separately).
53Item No. 5: Centering and shuttering including propping etc. where necessary and removal of forms after completion of C.C. and R.C.C. works as directed complete (measurement to be taken on the face area timbered). i)Column
54Item No. 6 : Supplying, fitting, fixing and laying reinforcement (TATA approved quality ) in position in R.C.C. work,including cutting, bending, cranking with two plies 0.91mm (20 BWG) annealed wire hooking tying complete as directed. 10mm dia12mm dia6mm dia
55Item No. 7:12 mm thick cement plasteringincluding clearing surface and curing complete as directed in prop. 1:4
56Construction & fixation of Sign Board (Qnty. for 4 pts)
57Item No. 1 :Supply of sign board made of 1.60mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75m fixed with 2 Nos. 50mm dia GI (medium) pipes 2.10m above and 0.60m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed.

AI Tender Summary

OUR REF NO 38194635
AUTHORITY Government Departments
TENDER VALUE 1.18 Crore
LAST DATE 04-07-2023
Authority
Authority Name Irrigation Department
Work Description Solar Powered Mdtws ( 4 Pts ) At Abhayapuri South ( Sc ) Lac Under Ridf-Xxviii ( Nabard ) For The Year 2022-23 Under Abhayapuri South-Bilashipara East Division ( I ) , Abhayapuri
Basic Detail
Tender No 03 _RIDF_XXVIII NABARD_ 2023_24 Dt 12_06_2023
Bidding Type Tender
Location
City abhayapuri
State Assam
Key Dates
Publish Date 15 Jun 2023
Submission Date 04 Jul 2023
Open Date 05 Jul 2023
Finance
Tender Value 1.18 Crore
Tender Fee 3000
EMD 2.36 Lakhs
Exemption Not Available
Document List
ee1d1911-3093-42a4-86dd-063823e46a5f.html
bid.pdf
BOQ_49949.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 15, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 04, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 05, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

ee1d1911-3093-42a4-86dd-063823e46a5f.html

pdf

bid.pdf

xls

BOQ_49949.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail