Military Engineer Services-MES has published Tender For Repair/Maint Of Summer Appliances, Cooling Appliances And Ac Plants Alongwith Connected Works At Certain Different Locations Under Ge (Utilities) Udhampur. Submission Date for this Tender is 14-07-2023. Air Conditioner Tenders in udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

38194287
Corrigendum : Tender For Repair/Maint Of Summer Appliances, Cooling Appliances And Ac Plants Alongwith Connected Works At Certain Different Locations Under Ge (Utilities) Udhampur
Open Tender
Indian
Jammu And Kashmir
udhampur
14-07-2023

Tender Details

Repair/Maint Of Summer Appliances, Cooling Appliances And Ac Plants Alongwith Connected Works At Certain Different Locations Under Ge (Utilities) Udhampur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Jun-2023 Other Other 07-07-2023
2 07-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 97000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repair/Maint of summer appliances, cooling appliances and AC plantsalongwith connected works at certain different locations under GE(Utilities) Udhampur.
Sl. No. Item Description
1M&L for Carry out Servicing, Oiling, Greasing and Cleaning of window type/ split type AC from authorised rep or service engineer from the manufacturer with high pressure pump of 1.0/1.5/2.0 ton capacity, checking of defects/ leaking and adjusting setting to work and testing complete all as specified and directed by Engr-in-Charge.
2M & L for cutting of suction line and discharge line tubing of AC, de-scaling of front scaled unit flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 1.0/1.5/2.0 ton Split/W/T type AC complete all as specified and directed by Engr-in-Charge.
3M&L for detection/rectification of leakage of gas by vacume the system, charging with Nitrogen gas and vacume the system after detaction of lekage and gas charging in the system with appropriate quantity of gas as per OEM Recomentation including testing for smooth functioning of Split type/ Window type AC of capacity 1.0/1.5/2.0 Ton complete all as specified and directed by Engr-in-Charge.
4Supply and topping up of refrigerant gas R-22 in Split air conditioner of capacity 1.5/ 2TR complete all as specified and directed by Engr-in-Charge.
5Supply and topping up of refrigerant gas R-410 in Split air conditioner of capacity 1.5/ 2TR complete all as specified and directed by Engr-in-Charge.
6Supply and topping up of refrigerant gas R-600in refrigerantor complete all as specified and directed by Engr-in-Charge.
7Supply and topping up of refrigerant gas R-134 in Water Cooler and Referigerator complete all as specified and directed by Engr-in-Charge.
8S&F in replacement of new indoor unit ofsplitACof capacity1.5 ton with compitable for existing out door unitfrom authorized dealers of company complete all as specified and directed by Engr-in-Charge.
9S&F in replacement of new indoor unit ofsplitACof capacity 2.0ton with compitable for existing out door unitfrom authorized dealers of company complete all as specified and directed by Engr-in-Charge.
10S&F in replacement of new outdoor unit ofsplitACof capacity 1.5 (w/o compressor) ton with compitable for existing indoor door unitfrom authorized dealers of company complete all as specified and directed by Engr-in-Charge.
11S&F in replacement of new outdoor unit ofsplitACof capacity 2.0 ton(w/o compressor) with compitable for existing indoor door unitfrom authorized dealers of company complete all as specified and directed by Engr-in-Charge.
12S&F in replacement of Electronic control Board(PCB)of Existing Make duly ISI marked for split type AC 1.0/1.5/2.0 Ton capacity complete all as specified and directed by Engr-in-Charge.
13S&F in replacement of Electronic control Board(PCB)for inverter type split AC of existing makes duly ISI marked for 1.5 /2.0Ton capacity complete all as specified and directed by Engr-in-Charge.
14S&F in replacement of Electronic control Board(PCB)of Existing Make duly ISI marked for window type AC 1.0/1.5/2.0 Ton capacity complete all as specified and directed by Engr-in-Charge.
15S&F in replacement of Thermostat switch of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and directed by Engr-in-Charge.
16S&F in replacement blower motor of Split type AC 1.5/2.0 Ton of existing make & modelcomplete all as specified and directed by Engr-in-Charge.
17S&F in replacement new rotary type AC compressor of existing split type/window type AC with New compressor from authorized dealers of OEM capacity 1.5 Ton complete all as specified and directed by Engr-in-Charge.
18All as per serial item No.17.00 here-in-before but of size 2.0 ton capacitycomplete all as specified and directed by Engr-in-Charge.
19S&F in replacement new Reciprocating type AC compressor of existing split type /window type AC with New compressor from authorized dealers of OEM capacity 1.5 Ton complete all as specified and directed by Engr-in-Charge.
20All as per serial item No.19.00 here-in-before but of size 2.0 ton capacitycomplete all as specified and directed by Engr-in-Charge.
21S&F in replacement of Evaporator coil 1.5 / 2.0 Ton complete all as specified and directed by Engr-in-Charge.
22Supply & fix in replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakagetesting with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump complete all as specified and directed by Engr-in-Charge.
23S&F in replacement of Copper tube cover(insulation) complete all as specified and directed by Engr-in-Charge. Note: insulation of 1/4" & 1/2" dia pipe measured as one unit.
24Material and labour for drain pipe rigid and flexible 20mm dia with clamps of suitable size as per site requirement complete all as specified and directed by Engr-in-Charge.
25Supply and fix in replacement ofunsv Reverse cycle valve for window type AC/ Split Type AC of capacity 1.5 Ton /2.0 Ton including welding, brazing complete all as specified and directed by Engr-in-Charge.
26Carry out Servicing, Oiling, Greasing and Cleaning of water cooler of capacity 40/80 ltr from authorised rep or service engineer from the manufacturer with high pressure pump, checking of defects/ leaking and adjusting setting to work and testing complete all as specified and directed by Engr-in-Charge.
27M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of capacity 40/80 Ltr complete all as specified and directed by Engr-in-Charge.
28S&F compressor reciprocating type (hermetically) sealed for capacity 40/80 litre water cooler complete all as specified and directed by Engr-in-Charge.
29M&L in replacement ofstarting relay and overload relay suitable for existing size and make water coolercomplete all as specified and directed by Engr-in-Charge.
30Carry out Servicing, Oiling, Greasing and Cleaning of Deep freezer of capacity 300/320 ltr from authorised rep or service engineer from the manufacturer with high pressure pump, checking of defects/ leaking and adjusting setting to work and testing complete all as specified and directed by Engr-in-Charge.
31S&F of starting relay of deep freezer of any sizecomplete all as specified and directed by Engr-in-Charge.
32M&L for gas chargingin deep freezer any make and capacity including testing of leakage complete all as specified and directed by Engr-in-Charge.
33S&F in repair replecement newsealed compressor suitable forDeep Freezer ofsingle phase, 230 Volt, 50 Hzof Deep Freezer of any Size in and including refrigerant gas filling up to required levelcomplete all as specified and directed by Engr-in-Charge.
34S&F in repair replecement newsealed compressorofsuitable forRefrigerator ofsingle phase, 230 Volt, 50 Hzof Refigerator of any Size in and including refrigerant gas filling up to required levelcomplete all as specified and directed by Engr-in-Charge.
35S&F of thermostat switch for refrigerator any make & capacity complete all as specified and directed by Engr-in-Charge.
36Supply and fixing water tap internal threaded /external threaded suitable for water cooler complete all as specified and directed by Engr-in-Charge.
37Taking out old existingunsvcoilSenser supply and fix newcoil senser of existing shape and sizesuitable for 1.5/2 Ton Split Type ACcomplete all as specified and directed by Engr-in-Charge.
38Taking out old existingunsv heating Senser supply and fix newheating senser of existing shape and sizesuitable for 1.5/2 Ton Split Type ACcomplete all as specified and directed by Engr-in-Charge.
39Taking out old unsv blower supply and fix new blower(plastic body)of 1.5/2.0 Ton Split/Window type AC (as per sample approved by GE) complete all as specified and directed by Engr-in-Charge.
40Supply & fixing in replacement of L -Shape thimble brass in pk(50Nos in one pkt) complete all as specified and directed by Engr-in-Charge.
41Supply & fixing in replacement ofthimble brass(50Nos in one pkt) suitable for all type of AC,Watercooler, Referigerator,Deep freezer in pkt complete all as specified and directed by Engr-in-Charge.
42Taking out old existingunserviceable and supply and fix new swing motor 0.3HP, 220 volts complete with Louvers, base ,clamps, nuts, bolts of size/shape suitable for 1.5/2.0 Ton Splt/window type AC of capacity 1.5 Ton. complete all as specified and directed by Engr-in-Charge.
43Fan motor1/20 HP single shaft for water cooler as per the original make of complete fan motorcomplete all as specified and directed by Engr-in-Charge.
44Fan Motor 1/35HP single shaft for water cooler complete all as specified and directed by Engr-in-Charge.
45Fan Motor 1/70HP single shaft for water cooler side holder, bushes with main lead. complete all as specified and directed by Engr-in-Charge.
46Supply and fixing in replacement of Fan motor with fan suitable for LG double door 286ltr / 310 Ltr refrigerators complete all as specified and directed by Engr-in-Charge.
47Supply and fixing in replacement of fan motorof 165/170 Litre Refrigerator and supplyand fix new fan motorof existing make, shape and sizecomplete all as specified and directed by Engr-in-Charge.
48All as per serial item No. 47.00 here-in-before but suitablefor single door 310 Litre Refrigerator complete all as specified and directed by Engr-in-Charge.
49Supply and fix in replacement & testing ofFan Motor of same model and type, single phase 230V complete with base and clamps, nuts and bolts of suitable size etc. against burnt/ defective motorof capacity 1/8 HP double shaft for 1.5 /2.0 Tonwindow type AC including base, frame, side clamps complete all as specified and directed by Engr-in-Charge.
50All as per serial item No. 49.00 Fan motor 1/7 HP for cooling coil of Split Type AC as per the original make of split type AC complete with base, frame, clamps, side holders, rubber bushes with main lead suitable complete all as specified and directed by Engr-in-Charge.
51Taking out old existing unsv Starting Capacitor of capacity 50+6 mfd supply and fixnew Multi purpose Running Capacitor of capacity 50+6mfd for window /split type AC complete all as specified and directed by Engr-in-Charge.
52All as per serial item No. 51.00 here-in-before but Starting Capacitor of capacity 40+80 mfd for water cooler complete all as specified and directed by Engr-in-Charge.
53All as per serial item No. 51.00 here-in-before but Starting Capacitor of capacity 40+60 mfd for water cooler complete all as specified and directed by Engr-in-Charge.
54All as per serial item No. 51.00 here-in-before but Starting Capacitor of capacity 80+100 mfd for water coolercomplete all as specified and directed by Engr-in-Charge.
55All as per serial item No. 51.00 here-in-before but Starting Capacitor of capacity 45+5 mfd for window /split type ACcomplete all as specified and directed by Engr-in-Charge.
56All as per serial item No. 51.00 here-in-before but Starting Capacitor of capacity 36+6 mfd for window /split type ACcomplete all as specified and directed by Engr-in-Charge.
57All as per serial item No. 51.00 here-in-before but Starting Capacitor of capacity 120+150 mfd for window /split type ACcomplete all as specified and directed by Engr-in-Charge.
58Taking out old existing unsv Multi purpose running Capacitor of capacity 10 mfd supply and fixnew Multi purpose running Capacitor of capacity 10 mfd for water coolercomplete all as specified and directed by Engr-in-Charge.
59All as per serial item No. 58.00 here-in-before but Starting Capacitor of capacity 4 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge.
60All as per serial item No. 58.00 here-in-before but Starting Capacitor of capacity 20 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge.
61Repair/replacement of water pump motor of desert cooler including electric connection and testing for better performance complete all as specified and directed by Engr-in-Charge.
62Replacement of "T" junction for desert cooler for watering the three side of the desert cooler with nozzels complete all as specified and directed by Engr-in-Charge.
63Replacement of Khas khas set for the doors of desert coolers complete all as specified and directed by Engr-in-Charge.
64Disconnecting and taking down unserviceable overload/PTC relay for water cooler ,Deep freezer and referigerator supply and fix new over load relay/PTC relay and testing for water cooler ,Deep freezer and referigeratorsatisfactory performance commissioning complete all as specified and directed by Engr-in-Charge.
65Disconnecting and taking down unserviceable overload/PTC relay for window / split AC 1.5/2.0 ton, supply and fix new over load relay/PTC relay and testing for window / split AC 1.5/2.0 ton, satisfactory performance commissioningcomplete all as specified and directed by Engr-in-Charge.
66Taking out old existing unserviceable diacharge valveand supply and fixnew discharge valve of 1.5/2 ton split type ACof any capacitycomplete all as specified and directed by complete all as specified and directed by Engr-in-Charge.
67Taking out old existing unserviceable suctionvalveand supply and fixnew suction valve of 1.5/2 ton split type ACof any capacitycomplete all as specified and directed by complete all as specified and directed by Engr-in-Charge.
68Taking out old existing unserviceable capillary and supply and fixnew capillary of 1.5/2 ton split type /window type AC.of any capacitycomplete all as specified and directed by Engr-in-Charge.
69Taking out old existing unserviceable dead Nut and supply and fixnew dead nut of 1.5/2 ton split type /window type AC.of any capacity complete all as specified and directed by Engr-in-Charge.
70Taking out old existing unserviceable NRVand supply and fixNRV of 1.5/2 ton split type /window type AC.of any capacity complete all as specified and directed by Engr-in-Charge.
71Supply and fix in replacement ofunserviceable remote control unitSuitable for 1.5 / 2.0Ton split type ACworking on both ( Hot & Cool) complete all as specified and directed by Engr-in-Charge.
72Taking out & re-fixing after repair to roof/building at same location / other location including shifiting where required, of split /window/casttee type AC by making hole, drilling , cutting on wall and necessary gas pipe connection , electric connections and insulations complete all as specified and directed by Engr-in-Charge. Note:- All items including gas, copper pipe and electric cable if required will be measured and paid separately in relevent items of contract complete all as specified and directed by Engr-in-Charge.
73Taking out old existing unserviceablemetal plug socket and supply and fix new metal plug and socket board complete enclosurewith single pole & neutral and earth plug with MCB SP 32 Amps, 220 Volts completesuitable for window/ Split type complete all as specified and directed by Engr-in- Charge.
74Taking out old existing unserviceable DB two Way and MCB SPN 40 Amps and Supply and fix Sheet Metal Enclosure with DBs single pole and neutral 2 Way, 240 volts bywith one SPN MCB of capacity 40 Ampscomplete all as specified and directed by Engr-in- Charge.
75S&F in replacement of MCB SPN 63 Amps, 10 KA,240V, 50Hz, "C" Seriescomplete all as specified and directed by Engr-in- Charge.
76Taking out old existing unserviceable front show grill and supply and fixnew front show grill for LG/Voltas /Sidwal/Godrejwindow type AC 1.5 Ton complete all as specified and directed by Engr-in- Charge.
77Disconnecting from electrical system carrying to workshop & back to store/site after repair dismantling the voltage stabilizer of capacity 7.5KVA,5KVA,2KVA thoroughly checking,cleaning all parts by brushing and assembling after repalcement of required burnt unserviceable parts / componenets, testing and comminssioning complete after necessary repair / replacement of components as belowcomplete all as specified and directed by Engr-in- Charge.
78M&L rewinding of main coil (primary/secondary) of voltage stailizer with super enameled copper wire of existing size including varnishing and insulation material of capacity 7.5KVAcomplete all as specified and directed by Engr-in- Charge.
79All as per serial item No.78.00 here-in-before but of capacity 5KVA complete all as specified and directed by Engr-in-Charge.
80All as per serial item No.78.00 here-in-before but of capacity 2KVA complete all as specified and directed by Engr-in-Charge.
81M&L in replacement of relay for 7.5KVA & 5KVA,30amp 24volts DC complete all as specified and directed by Engr-in-Charge.
82M&L in replacement of Step down transformer for voltage stailizer 24 volts 2Amp for 7.5 KVA & 5KVA complete all as specified and directed by Engr-in-Charge.
83M&L in replacement of circuit plate for voltage stailizer with connection wire complete all as specified and directed by Engr-in-Charge.
84M&L in replacement of relay for voltage stailizer 0.5KVA, 1KVA & 2KVA,16Amp 24V DC complete all as specified and directed by Engr-in-Charge.
85M&L in replacement of Voltmeter 0- 300V, AC 75 Sqm complete all as specified and directed by Engr-in-Charge.
86M&L in replacement of Ampre meter 0- 30Amp, AC 75 Sqm complete all as specified and directed by Engr-in-Charge.
87M&L in replacement of push switch complete all as specified and directed by Engr-in-Charge.
88M&L in replacement of time delay circuit for voltage stailizer complete all as specified and directed by Engr-in-Charge.
89M&L in replacement of connector switch 30amp 220volts AC complete all as specified and directed by Engr-in-Charge.
90Repairing /Servicing and rewinding of motor 3 phase 400-440 volt complete disconnecting the electric supply removing of pully and fan and opening of both end covers taking out Bearings and rotor checking of air gap, checking of rotor field winding, replacement of bearings, greasing fo bearings including rewiring with superior quality copper winding wire insulating material, vanishing binding of winding etc complete all as directed by Engr -in-Charge reassembling, replacing rusted nut, bolts, washers, checking and adjusting the alignment, connecting electric connection completed complete all as specified and directed by Engr-in-Charge.For the following :-
91Electric motor 3 phase 70 HP of AC Plant complete all as specified and directed by Engr-in-Charge.
92Electric motor 3 phase 15 HP of AC Plant complete all as specified and directed by Engr-in-Charge.
93Electric motor 3 phase 10 HP of AC Plant complete all as specified and directed by Engr-in-Charge.
94Electric motor 3 phase 5 HP of AC Plant complete all as specified and directed by Engr-in-Charge.
95Electric motor 3 phase 3 HP of AC Plant complete all as specified and directed by Engr-in-Charge.
96Repairing/ servicingof water pump including removing of old gland packing, gland bolt and fixing of new gland packing , gland bolt, cleaning of impeller/Replacement of impeller complete all as specified and directed by Engr-in-Charge for the following :-
97Monoblock pumping set 10.0 HPcomplete all as specified and directed by Engr-in-Charge.
98Monoblock pumping set 3.0 HPcomplete all as specified and directed by Engr-in-Charge.
99Descaling of condenser after opening of both end cover, circulation of descaling solution forcibly using pump for circulating decaling solution and rubbingmanually using nylon brush of size 1/4,3/8,1/2,5/8 inch descaling rod etc without damaging copper tubing and re-fixing of side cover using new gasket of rubber insulation sheet of 3mm thick and replacement of rusted nuts bolts etc complete all as specifiedand directed by Engr-in-Charge for the following:-
10047.5TR cap Condenser complete all as specified and directed by Engr-in-Charge.
1017.5TR cap Condenser complete all as specified and directed by Engr-in-Charge.
102Repairing serving of cooling coil tower of AC plat FRP Type by dismantling ad taking out the one comb PVC files complete ad PV Nozzles the PVC files by suitable descaling solution including bruising and cleaning complete with cleaning solution and water replacing the defective PVC flange along with rubber gasket and rusted bolts nuts and washer etc cleaningthe water sump ad XMP wire mesh with suitable cleaning solution re-assembling the same including replacing the defective water filter flanges of pipe joints etc and testing complete all as specifiedand directed (PVC Files will be measured ad paid separatelyfor the following:-
10395 TR Capacity plant installed at CHNC A/C Plant complete all as specified and directed by Engr-in-Charge.
10450 TR Capacity plant installed at OPS room A/C Plant complete all as specified and directed by Engr-in-Charge.
10512.5 TR Capacity plant installed at 37AMSD A/C Plant complete all as specified and directed by Engr-in-Charge.
106Supply and fixing in replacement of 110 Amp,3pole, 415 Volts, 50 Hz Power contactor (MNX110) auxiliary contact 2 NO + 2 NC, of coil voltage 440 Volts, complete all as specified and directed by Engr-in-Charge.
107Supply and fixing in replacement of 32 Amp,3pole, 415 Volts, 50 Hz Power contactor (MNX32) auxiliary contact 2 NO + 2 NC, of coil voltage 440 Volts,complete all as specified and directed by Engr-in-Charge.
108MCCB Three pole 415 Volt 50 Hz 160 Amps wit breaking capacity 25 KA type DT complete all as specified and directed by Engr-in-Charge.
109MCCB Three pole 415 Volt 50 200 Amps with breaking capacity 25 KA type complete all as specified and directed by Engr-in-Charge.
110Supply and fixing in replacement of Single phase priventer (minilec VSP D2/240 VAC Phase Failure relay) complete all as specified and directed by Engr-in-Charge.
111Over load relays MK 1 Type relays range 75 to 110 Amps complete all as specified and directed by Engr-in-Charge.
112Over load relays MK 1 Type relays range 44 to 75 Amps complete all as specified and directed by Engr-in-Charge.
113Over load relays MK 1 Type relays range 14 to 23 Amps complete all as specified and directed by Engr-in-Charge.
114Supply & fix HEPA filter 10 to 20 microns static wove both side DPE mesh in aluminium frame efficiency 90% of sizes as per site requirement complete all as specified and directed by Engr-in-Charge.
115Supply & fix factor made performance HEPA filters of 99 micro down to 5 micro of standard sizewith multiple pockets & self supporting filters bags with MS/GI anodised aluminium frame suitable for central AC Plant including replacement of bolts & nuts & taking down unserviceable complete all as specified and directed by Engr-in-Charge.
116Provide skilled technician for attendingofanybreakdown of VRF type AC Plant of capacity 25 HP / 16 HP whenever required round the clock ,rectify the fault and restart the plant within three hour after receipt of complaint of any nature i.e. Compressor, Condenser,control panel etc complete all as specified and directed by Engr-in-Charge. Note -(i) The cost ofreplaced spare parts will be paid and measured separately.(ii)If complaint is not attended by contractor with in five hour the penalty of Rs 500 / per hourto be imposed and amount of penalty will be deducted from RAR. (iii) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specifythe telephone no who willreceive the complaint round the clock.
117M&L for servingof air VRF type AC Plant of capacity 24 HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasketcomplete all as specified and directed by Engr-in-Charge. Note :Necessary Nut, Bolts, washers, pickings are included in quoted rate.
118M&L for servingof air VRF type AC Plant of capacity 20 HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasketcomplete all as specified and directed by Engr-in-Charge. Note :Necessary Nut, Bolts, washers, pickings are included in quoted rate.
119M&L for servingof air VRF type AC Plant of capacity 16 HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasketcomplete all as specified and directed by Engr-in-Charge. Note :Necessary Nut, Bolts, washers, pickings are included in quoted rate.
120M&L for serving of air VRF type AC Plant of capacity 16 HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasketcomplete all as specified and directed by Engr-in-Charge. Note :Necessary Nut, Bolts, washers, pickings are included in quoted rate.
121M&L for serving of air VRF type AC Plant of capacity 8HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasketcomplete all as specified and directed by Engr-in-Charge. Note :Necessary Nut, Bolts, washers, pickings are included in quoted rate .
122M&L for serving of air VRF type AC Plant of capacity 8HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasketcomplete all as specified and directed by Engr-in-Charge. Note :Necessary Nut, Bolts, washers, pickings are included in quoted rate.
123M&L for serving of air Handling Unit of capacity 2500 CFM by opening of both side cover taking out the Fresh air filter cleaning the External & Internal surface of AHU, Primary air filter, wire mesh filter, Tumble Blower fan and re-fixing the side covers head covers after painting & necessary welding including replacing the suitable gasketcomplete all as specified and directed by Engr-in-Charge. Note:Necessary Nut, Bolts, washers, pickings are included in quoted rate.
124M&L for serving of air Handling Unit of capacity 25000 CFM by opening of both side cover taking out the Fresh air filter cleaning the External & Internal surface of AHU, Primary air filter, wire mesh filter, Tumble Blower fan and re-fixing the side covers head covers replacing the suitable gasket if required complete all as specified and directed by Engr-in-Charge. Note:Necessary Nut, Bolts, washers, pickings are included in quoted rate.
125All as per serial item No 12.00 here-in-before but for 5000 CFM complete all as specified and directed by Engr-in-Charge.
126Supply and fix V Belt of following sizes complete all as specified and directed by Engr-in-Charge.
127V-Belt B-67 complete all as specified and directed by Engr-in-Charge.
128V-Belt B-68 complete all as specified and directed by Engr-in-Charge.
129V-Belt B-70 complete all as specified and directed by Engr-in-Charge.
130V-Belt B-124 complete all as specified and directed by Engr-in-Charge.
131Supply & Fix in replacement PVC sheathed 6 sqmm 3 core copper conductor cablecomplete all as specified and directed by Engr-in-Charge.
132Supply and charging refrigerant gas R-410 complete all as specified and directed by Engr-in-Charge.