| 1 | Material and labour for servicing/maintenance of split type air conditioner 1.5/2.0 ton capacity in situ by cleaning of complete outdoor unit and indoor unit, air blower units, air filter, grills with required chemical solution and using forced air blower or vaccuum cleaner, complete checking serviceability of electrical circuit of outdoor and indoor unit, electronic circuit, airblower unit, condenser, remote control unit, including replacement of unserviceable spares such as relays, capacitors, wiring kit, screws, nuts, bolts & washers, remote control unit and testing after completion to entire satisfaction of Engr-in-Charge as well as user unit.NOTE :- (i) Minor Spares required for replacement shall be measured and paid separately and labour charges shall deemed to be included in the quoted rate. (ii) Screws, nuts, bolts & washers shall be inclusive of quoted rate . |
| 2 | Description all as per item No. 1 above but for window type air conditioner of capacity 1.5/2.0 ton. |
| 3 | Supply only following spares for Split/Window type air conditioner of 1.5 /2.0 Ton cap.MAKE :- Blue Star, LG, Hitachi, Voltas & Samsung, |
| 4 | Running capacitor 45 to 60mfd |
| 5 | Starting capacitor 120-150mfd / 150-200 mfd |
| 6 | Starting relay suitable for reciprocating compressor |
| 7 | Thermostat switch for window type AC |
| 8 | Conderser fan blade for window/split type AC made of plastic/aluminium |
| 9 | Remote control unit as per original MAKE complete with 2 Nos Duracell battery |
| 10 | Plastic grill with louvers front panel for window AC as per existing MAKE and model |
| 11 | Selector switches for window type AC |
| 12 | Air filter suitable for indoor unit of split type AC 1.5 /2.0 tr capacity |
| 13 | Air filter suitable for window type AC 1.5 /2.0 tr capacity |
| 14 | Flexible PVC drain pipe 15/20mm bore |
| 15 | Supply & fix in repair rotary compressor unit suitable for split type AC 1.5 TR Cap with required nuts, bolts & washers,connecting necessary copper tubings by gas welding, gas charging with R-22, replacement of capilary tube and drier filter after dismentling/taking out existing unserviceabl / burnt compressor unit from the split type air conditioner 1.5 Ton cap in situ andtesting after completion to entire satisfaction of Engr-in-Charge .MAKE:- Blue Star/ LG/ Hitachi/ Voltas/Samsung.NOTE :- (i) MAKE of compressor shall be as recommended by OEM. (ii) Gas charging shall be measured and paid separately under relevant item. |
| 16 | Description all as per item No. 15 above but for split AC 2 TR Capacity. |
| 17 | Supply & fix in repair reciprocating compressor unit suitable for Window type AC 1.5 TR Cap with required nuts, bolts & washers,connecting necessary copper tubings by gas welding, gas charging with R-22, replacement of capilary tube and drier filter after dismentling/taking out existing unserviceable/burnt compressor unit from the split type air conditioner 1.5 Ton cap in situ and and testing after completion to entire satisfaction of Engr-in-Charge . MAKE :- Blue Star/ LG/ Hitachi/ Voltas/Samsung. NOTE :- (i) MAKE of compressor shall be as recommended by OEM. (ii) Gas charging shall be measured and paid separately under relevant item. |
| 18 | Description as per item No.17 above but for Window type AC 2 TR Capacity. |
| 19 | Supply & fix in repair blower motor with required nuts, bolts & washers,connecting necessary wires, fixing of fan complete from the window type air conditioner 1.5/2.0 ton cap in situ and testing after completion to entire satisfaction of Engr-in-Charge. |
| 20 | Supply & fix in repair blower motor with required nuts, bolts & washers,connecting necessary wires, fixing of fan complete from the Split type air conditioner 1.5/2.0 ton cap in situ and testing after completion to entire satisfaction of Engr-in-Charge. |
| 21 | Supply and fix in repair electronic circuit board (PCB) suitable for 1.5/2.0 ton Window type AC as per existing MAKE and model including testing complete to entire satisfaction of Engr-in-charge. |
| 22 | Description all as per item no.21 above but for 1.5/2 Ton capacity Split type AC. |
| 23 | Supply and fix in repair condenser coil unit of window type AC of cap 1.5 Ton cap in situ as per existing MAKE and model, connecting necessary copper tubings by gas welding, gas charging with R-22 and testing after completion to entire satisfaction of Engr-in-Charge. Note: Gas charging shall be measured and paid separately under appropriate item of this schedule. |
| 24 | Description allas per item no. 23 above but for window type AC 2 Ton capacity |
| 25 | Supply and fix in repair cooling coil unit of window type AC of cap 1.5 ton cap in situ as per existing MAKE and model, connecting necessary copper tubings by gas welding, gas charging with R-22 and testing after completion to entire satisfaction of Engr-in-Charge.Note: Gas charging shall be measured and paid separately under appropriate item of this schedule. |
| 26 | Description all as per item no. 25 above but for window type AC 2 Ton capacity |
| 27 | Supply and fix in repair outdoor unit of split type AC of cap 1.5 Ton cap in situ as per existing MAKE and model completewith compressor, blower motor, fan, connecting nessary copper tubings by gas welding, gas charging with R-22and testing complete to entire satisfaction of Engr-in-Charge. MAKE :- Blue Star, LG, Hitachi, Voltas & Samsung. |
| 28 | Description allas per item no. 27 above but for Split type AC 2 Ton Capacity. |
| 29 | Supply and fix in repair indoor unit of split type AC of cap 1.5 Ton cap complete with cooling unit, PCB, Blower motor, Swing motor andremote unit in situ as per existing MAKE and model complete, connecting necessary electrically and copper tubings by gas welding, gas charging with R-22 and testing complete to entire satisfaction of Engr-in-Charge .MAKE :- Blue Star/ LG/ Hitachi/Voltas/Samsung. |
| 30 | Description allas per item no. 29 above but for Split type AC 2 Ton Capacity. |
| 31 | Supply and fix in repair louvers swing motor suitable for window type AC of cap 1.5 ton cap in situ as per existing MAKE and model includingnecessary electrical connection and testing complete to entire satisfaction of Engr-in-Charge. |
| 32 | Description allas per item no.31 above but for Window type AC 2 Ton capacity. |
| 33 | Supply and fix in repair louvers swing motor suitable for indoor unit of split type AC of cap 1.5 ton cap in situ as per existing MAKE and model includingnecessary electrical connection and testing complete to entire satisfaction of Engr-in-Charge. |
| 34 | Description allas per item no. 33 above but for Split type AC 2 Ton Capacity |
| 35 | Material and labour for servicing/maintenance of water cooler of cooling capacity 40/60/80/120 LPH any storage capacity in situ by cleaning of complete cooling coil, condenser unit, air blower units, grills, external body surface, internal body surface with required chemical solution and using forced air blower or vaccuum cleaner, cleaning water storage tank, checking serviceability of electrical circuit of unit, airblower unit, condenser, cooling coil, thermostat, copper tubings, operating knobs, push cocks, drain trays, drain pipes, float valves, relays, OL protector including replacement of unserviceable spares such as relays, OL protector, capacitors, thermostat, wiring kit, operating knobs, push cocks, float valves, Screws, nuts, bolts & washers of water cooler of any MAKE and testing after completion to entire satisfaction of Engr-in-Charge. NOTE :- (i) Minor Spares required for replacement shall be measured and paid separately and labour charges shall deemed to be included in the quoted rate. (ii) Screws, nuts, bolts & washers shall be inclusive of quoted rate |
| 36 | Supply only following spares of water cooler of cap 40/60/80/120 LPH. MAKE :- Usha, Voltas, Blue Star |
| 37 | Over load protector (OLP) |
| 38 | Starting relay |
| 39 | Thermostat |
| 40 | Starting capacitor 40/60 mfd |
| 41 | Starting capacitor 80-100 mfd |
| 42 | Running capacitor 4 to 25 mfd |
| 43 | Drain Hose pipe 20mm to 30mmdia plastic |
| 44 | CP push cock 15 mm dia |
| 45 | PVC float valve 15mm dia |
| 46 | PVC/aluminium fan for condenser blower motor |
| 47 | Supply and fix in repaircompany sealed reciprocating compressor unit with required nuts, bolts & washers,connecting necessary copper tubings by gas welding, gas charging with R-22, replacement of capilary tube and oil filterfrom the water cooler 40LPH/80LPH (cooling/Storage) capacity in situ and and testing after completion to entire satisfaction of Engr-in-Charge.MAKE :- Usha, Voltas & Blue Star .NOTE :- (i) MAKE of compressor shall be as recommended by OEM. (ii) Gas charging shall be measured and paid separately under relevant item. |
| 48 | Description allas per item No.47 above but water cooler of capacity 120 LPH/150 LPH |
| 49 | Supply and fix in repair condenser coil unit of water cooler 40/80 Ltr cap as per existing MAKE and model, connecting necessary copper tubings by gas welding, gas charging with R-22 and testing after completion to entire satisfaction of Engr-in-Charge. NOTE :- (i) Gas charging shall be measured and paid separately under appropriate item. (ii) MAKE of item shall be as recommended by OEM. |
| 50 | Description all as per item No.49 above but water cooler of capacity 120 LPH/150 LPH |
| 51 | Supply & fix in repair new condenser fan motor with required nuts, bolts & washers,connecting necessary wires, fixing of fan completefor the water cooler of cooling cap 40/80Lin situ and and testing after completion to entire satisfaction of Engr-in-Charge. MAKE - Usha/Voltas/Bluestar. |
| 52 | Description allas per item No.51above but water cooler of capacity 120 LPH/150 LPH |
| 53 | Supply and fix in repair drain tray of existing size made of stain less steel with required nuts, bolts or screws suitable for any cap of water cooler complete all as specified and directed by Engr-in-Charge . |
| 54 | Material and labour for Base frame as per sample suitable for 40/80 Ltrs water cooler made out of MS angle iron, flats, cut to required length, making necessary shape, screw holes, fixing with necessry electric welding, painting with one coat of red oxide and two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge . |
| 55 | Description all as per item no.54 above but water cooler of capacity 120/150 LPH. |
| 56 | Material and labour for servicing/maintenance of desert cooler of any MAKE of cap 1800/2500 CMH of steel or PVC body in situ by cleaning of complete external surface, internal surface, water trays and grass pad at dry condition, grills, with required chemical solution and using forced air blower or vaccuum cleaner, checking serviceability of electrical circuit of unit, selector knobs, water pump, grass pad, blower motor, fans, blower motor mounting MS clamps, nuts, bolts & washers, float valves including replacement of unserviceable spares such as wiring kit, selector knobs, float valves, nuts, bolts washers, screwsand testing after completion to entire satisfaction of Engr-in-Charge. NOTE :- (i) Minor Spares required for replacement shall be measured and paid separately and labour charges shall deemed to be included in the quoted rate. (ii) Screws, nuts, bolts & washers shall be inclusive of quoted rate |
| 57 | Supply only following spares for desert cooler of any MAKE and capacity:- |
| 58 | Wiring kit |
| 59 | Selector switch |
| 60 | PVC float valve 15mm dia |
| 61 | Natural grass pad (set of 3) |
| 62 | Blower motor of suitable capacity including necessary electric connection, mounting nuts, bolts & washers |
| 63 | PVC fan blade for blower motor |
| 64 | Water spray pump |
| 65 | PVC flexible pipe 6mm to 10mm |
| 66 | Material and labour for servicing/maintenance of Refrigerator of any capacity in situ by cleaning of complete external surface, internal surface, trays, racks with required chemical solution removing all dirt, strains complete checking serviceability of electrical circuit of unit, thermostat knob, fans if provided in frost free model, relays, thermostat, trays including replacement of unserviceable spares such as relays, thermostat, trays and testing after completion to entire satisfaction of Engr-in-Charge. NOTE :- (i) Minor Spares required for replacement shall be measured and paid separately but labour charges shall deemed to be included in the quoted rate. (ii) Screws, nuts, bolts & washers shall be inclusive of quoted rate |
| 67 | Supply only Starting relay for refrigerator of any MAKE and capacity. |
| 68 | Supply only Thermostat for refrigerator of any MAKE and capacity. |
| 69 | Supply & fix in repair new company sealed reciprocating compressor unit for refrigerator of capacity 165 ltr to 310 ltr with required nuts, bolts & washers,connecting necessary copper tubings by gas welding/brazing, gas charging with R-134A and testing after completion to entire satisfaction of Engr-in-Charge. MAKE :- Godrej/Whirlpool/Videocon/LG . NOTE :- (i) MAKE of compressor shall be as recommended by OEM. (ii) Gas charging shall be measured and paid separately under relevant item. |
| 70 | Supply & fix in repair condenser unit for refrigerator of capacity 165 ltr to 310 ltr with required nuts, bolts & washers,connecting necessary copper tubings by gas welding/brazing, gas charging with R-134A in situ and and testing after completion to entire satisfaction of Engr-in-Charge. MAKE :- Godrej/Whirlpool/Videocon/LG. NOTE :- (i) MAKE of Condenser unit shall berecommended by OEM. (ii) Gas charging shall be measured and paid separately under appropriate item. |
| 71 | Material and labour for servicing/maintenance of Deep Freezer of capacity 300L/310L/450L of any MAKE in situ by cleaning of complete external surface, internal surface, trays, racks with required chemical solution removing all dirt, strains complete and checking serviceability of electrical circuit of unit, condenser unit, relays, thermostat, trays including replacement of unserviceable spares such as relays, capacitors, thermostat, trays and testing after completion to entire satisfaction of Engr-in-Charge. NOTE :- (i) Minor Spares required for replacement shall be measured and paid separately but labour charges shall deemed to be included in the quoted rate. (ii) Screws, nuts, bolts & washers shall be inclusive of quoted rate |
| 72 | Supply only following spares forDeep freezer of cap 300/310/450 Ltr of any MAKE :- |
| 73 | Over load protector |
| 74 | Starting relay |
| 75 | Thermostat |
| 76 | Starting capacitor 40/60 mfd |
| 77 | Starting capacitor 80-100 mfd |
| 78 | Running capacitor 4 to 25 mfd |
| 79 | Sliding trays small as per existing MAKE & model |
| 80 | Sliding trays large as per existing MAKE & model |
| 81 | PVC fan for blower motor |
| 82 | Supply & fix in repair new company sealed reciprocating compressor unit with required nuts, bolts & washers,connecting necessary copper tubings by gas welding/brazing, gas charging with R-22, replacement of capillary tube and oil filter unit from the Deep freezer 300/310/450L capacity and and testing after completion to entire satisfaction of Engr-in-Charge. MAKE :- Honeydew/Voltas/Bluestar NOTE :- (i) MAKE of compressor shall be as recommended by OEM. (ii) Gas charging shall be measured and paid separately under relevant item. |
| 83 | Supply and fix in repair condenser coil unit of Deep freezer 300/310/450 L as per existing MAKE and model, connecting necessary copper tubings by gas welding, gas charging with R-22 and testing after completion to entire satisfaction of Engr-in-Charge. NOTE :- (i) Gas charging shall be measured and paid separately under appropriate item (ii) MAKE of item shall be as recommended by the OEM. |
| 84 | Supply & fix in repair blower motor with required nuts, bolts & washers,connecting necessary wires, fixing of fan complete for the Deep freezer of capacity 300/310/450L and and testing after completion to entire satisfaction of Engr-in-Charge. |
| 85 | Material and labour for refrigerant gas charging for split type AC of cap 1.5 TR/2 TR with R-22 gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquid line filter, capillary tube, required soldering/brazing/gas welding to attaing proper cooling level to entire satisfaction of Engr-in-Charge. |
| 86 | Material and labour for refrigerant gas charging for window type AC of cap 1.5/2 TR with R-22 gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquid line filter, capillary tube, required soldering/brazing/gas welding to attaing proper cooling level to entire satisfaction of Engr-in-Charge. |
| 87 | Material and labour for refrigerant gas charging for water cooler of cap 40/80 to 120/150 LPH with R-22 gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquid line filter, capillary tube, required soldering/brazing/gas welding to attaing proper cooling level to entire satisfaction of Engr-in-Charge. |
| 88 | Material and labour for refrigerant gas charging for Deep freezer of cap 300/310/450L with R-22 gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquid line filter, capillary tube, required soldering/brazing/gas welding to attaing proper cooling level to entire satisfaction of Engr-in-Charge. |
| 89 | Material and labour for refrigerant gas charging for Refrigerator of cap 165 L to 310 L with R-134A gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquid line filter, capillary tube, required soldering/brazing/gas welding to attaing proper cooling level to entire satisfaction of Engr-in-Charge. |
| 90 | Material and labour for Painting of water cooler body of any capacity by spray painting after preparation of surface with existing colour complete all as specified by Engr -in-charge. |
| 91 | Material and labour for Painting of outdoor unit of split A/C of any capacity by spray painting after preparation of surface with existing colour complete all as specified by Engr -in-charge. |
| 92 | Material and labour for Numbering of cooling appliances (window/split A/c\"s, w/coolers, Deep freezers, Fridge etc in situ up to 10 M installedHeight with the help of ladder etc ) with white colour in black back ground up to 10 cm width and height all as directed by the Engr-In-Charge. |
| 93 | Material and labour for dismentling unsv voltage stabiliser of capacity 1 KVA to 2 KVA of any MAKE for repair including replacement of relays, electronic voltage sensor, circuit and meter, micro switch, indicating light, RC filter, and other connected items for making functional and rewinding of transformer unit with suitable size of super enamelled coper wire, heating, varnishing and testing complete all as specified and directed by Engr -in- Charge. |
| 94 | Material and labour for dismentling unsv voltage stabiliser of capacity 3 KVA to 5 KVA of any MAKE for repair including replacement of relays, electronic voltage sensor, circuit and meter, micro switch, indicating light, RC filter, and other connected items for making functional and rewinding of transformer unit with suitable size of super enamelled coper wire, heating, varnishing and testing complete all as specified and directed by Engr -in- Charge. |