}

Tender For Repairs To Compound Wall, Drains, Gates, Flooring And, marathahalli-Karnataka

Military Engineer Services-MES has published Tender For Repairs To Compound Wall, Drains, Gates, Flooring And. Submission Date for this Tender is 18-07-2023. Wall construction Tenders in marathahalli Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

38194218
Corrigendum : Tender For Repairs To Compound Wall, Drains, Gates, Flooring And
Open Tender
Indian
Karnataka
marathahalli
18-07-2023

Tender Details

Repairs To Compound Wall, Drains, Gates, Flooring And Repairs To Compound Wall Drains Gates Flooring And Roof Treatment To Certain Buildings At Iam And Vv Camp Under Ge Af Marathahalli Bangalore

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Jun-2023 BOQ AND OTHER CORRIGENDIUM BOQ 06-07-2023
2 06-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-07-2023
3 13-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 74000.0 /-
Tender Value
INR 37 Lakhs /-

BOQ Items

Name of Work: REPAIRS TO COMPOUND WALL, DRAINS, GATES, FLOORING AND ROOF TREATMENTTO CERTAIN BUILDINGS AT IAM AND VV CAMP UNDER GE (AF) MARATHAHALLI, BANGALORE.
Sl. No. Item Description
1Dismantling floor, hearth or wall tiling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
2M&L for glazed ceramic coloured tiles in vertical surfaces350x250 x 7 mm / 450x350x7 mm thick , set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles over and including 15mm thick cement plaster in 1:3 as backing coat complete all as specified and as directed
3M&L for 25mm thick cement concrete, 1:2:4 Type B-1 (20mm graded crushed stone aggregate) as in levelling coarse in flooring finished even and fair under floor finishes.
4M&L for Vitrified Ceramic Colour tiles 9 to 10 mm thick (Square / Rectangular) polished , area of each tiles not exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles over and including cement screed or bedding layer of cement mortar 1 5mm thick in 1:4 complete all as specified and as directed
5M&L for non skid coloured ceramic tiles 7mm thick of size 400mX400mm in floor set and jointed in cement slurry and pointed with coloured cement to match with coloured tiles over and including cement screed or bedding layer of cement mortar 15mm thick in 1:4 complete all as specified and as directed.
6M&Lfor Pre polishedchequred cement concrete tiles of size30cm x 30cm x 25mm thick set and jointed & pointed in neat cement slurry in floor with grey cement and pigment over and including 15mm thick screed bed or bedding layer in cement mortor 1:4 complete all as specified and directed.
7Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons incl granite slab in kitchen platform Laid, bedded and pointed in any mortar etc all as specified and as directed.
8M & L for Machine cut kota stone slab flooring 20mm thick over and including 15mm thick cement screed base laid in mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed
9M & L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms over and including 15mm thick cement screed base laid in mortar 1:4including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed .
10Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed
11Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles all as directed.
12M&L for Pre-cast cement concrete block masonry1:3:6, Type C-1 (20 mm graded crushed stone aggregate) with solid blocks, exc.10cm in width and setting in mortar complete in cement mortar 1:6 all as specified and directed.
13Demolition of cement concrete/ removal of waterproofing membrane/roof tiles (unreinforced) (other than ground floors),roofs and similar suspended work.(Note: Height of the building varies from 3m to 10m from GL)
14M&L for 40 mm thick cement concrete 1:2:4type B-1 (20 mm graded crushed stone aggregate) as inpadding concrete on roofall as specifed and directed.
15Taking down cement plaster on brick work or stone wall etc including racking out joints, hacking for key, scrubbing down with water etc all as specified and directed.
16M & L for Rendering 15mm thick in cement mortar 1:4 on concrete/ masonarysurfaces other than fair face of brick work with water proofing compound finished fair and even without using extra cement.
17M & L for rendering 15 mm thick in cement mortar 1:6 on brick or concrete surfaces finished even and smoothwithout using extra cement all as specified and as directed.
18M& L for rendering 10mm thick cement plaster in cement mortar 1:3 on fair faces of brick work on concrete surfaces on ceilingincluding finished even and smooth all as specified and directed.
19M&L, for rendering 10 mm thick in cement mortar 1:3 on concrete surface on roof top while concrete is greenwith using water proofing compound including to be finished even and smooth surfaces without using extra cement complete all as specified and directed.
20Supply only integralliquid water proofing compound .
21Providing and laying water proofing treatment to the podium slab area with Home shield PU elastoseal AR single component liquid applied,cold applied, moisture cured high tensile elastomeric PU waterproofing membrane @ 1.5 kg per sqm in 2 coats to achieve final DFT of 1.3 to 1.5 mm DFT including prime coat of HS PU Elastoprime @8-10 sqm per ltr of same material.Cost toinclude surface preparation completely as perspecification and direction of engineer in charge.
22Demolition of cement concrete (unreinforced) in ground floors and paving n.exc. 15cm thickness (below or above ground).
23M&L for 75mm thick PCC 1:3:6 type C-2 using40mm graded crushed stone aggregate as in plinth protection finishing surface even and fair all as specified and directed.
24M & L for Providing, cement concrete1:2:4 , Type B-1(20 mm graded crushed stone aggregate) in lintels/chajjas upto 1.5m clear span, cills, steps;including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and as directed
25Dismantiling wrought iron or mild steel work of any description not otherwise provided for etc comoplete all as specified.
26S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St-240 complete all as specified and as directed
27S&F tubular membersas in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates complete all as specified and as directed
28S&F M S Plate (Plain or chequired ) channels , square but or notched ordinary and counter sunk forming holes with riveted bolted or welded attachment of Fe- 410-W Gde E-250 (quality A) all as specified and as directed.
29Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering
30S&F Pre-laminated galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an approved colour having tensile strength of 550 Mpa as in roof covering in any curvature, fixed with self tapping screws complete all as specified and as directed .
31S&F in repairs aluminium composite panel sheet of 3 mm thick any size and approved colour fixed with self taping screwd on verical surfacesof wall or cladding complete all as specified and directed
32M&L for preparation ofnew steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying 2 coats of synthetic enamel paint over a coat of red oxide primer.
33Dismantling wall and ceiling boards (Fibre, pulp, insulation etc.) or insulation board/slabs/blankets) any thickness including cover fillets
34S& F Anodised aluminium snap grid frame work of size 605 X 605 mm for false ceiling complete all as specified and directed.
35M & L for 8 mm thick Non asbestos fibre cement building board fixed or laid/inserted to timber / GI /Aluminium frame work with screws for indulation and accoustic purpose, 60 x 60 cm in size fixed with nails to framework or stales on snap grid complete all as specified and directed
36Removing by cutting/up rooting plant/tree under surface of wall/celling/roof including pouring of acid on the place and making good the damage portion with cement mortar 1:3 or concrete 1:2:4 type B1using 20 mm graded aggregate complete and removing of material retrived from above work to outside of MoD landall as specified and as directed (Note: Height of bldg is upto 3m)
37Removing by cutting/up rooting plant/tree under surface of wall/celling including making good the damage portion with cement mortar 1:3 or concrete 1:2:4 type B1using 20 mm graded aggregate complete all as specified and as directed(Note: Height of bldg is from 3m to 10m from GL)
38S&Fin repairs 20mm bore(OD) CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/ walls and ceilingall as specified and as directed.
39S&Fin repairs 25mm bore(OD) CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/ walls and ceilingall as specified and as directed.
40S&F in repairs110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed with wall including necessary fixing cleats/ clamps,complete all as specified and directed.
41S&F PVC bends of 110 mm bore complete all as specified and directed.
42Taking down and Refixing of wooden shutters in same opening exceeding 1Sq.m. and not exceeding 2 Sqm each all as specified and as directed. (Note :`refixing" includes taking down, easing and ajusting and also refixing builders hardware as required including renewal of unserviceable screws, etc.) etc all as specified and as directed.
43M&L for Removing material or debries retrives from above demolition or cleaningto a distance exceed 1.5 Km and not exceeding 5.0 Kmand depositing where directedcomplete all as specified and directed
44M&L two coat of cement based paint on undecorated wall surfaces including preparation of new plastered surfaces all as specified and directed.
45M&L for two coats of oil bound distemper over one coat of Priming plastered and other surfaces with alkali resistant priming paint on newly plastered wall surfaces including preparation all as specified and as directed.
46Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
47M & L for Walling of squared rubble,regular coursed, well bonded,bedded and solidly hearted masonarybuilt in CM 1:6 including hammer dressing all as specified and directed.
48All as per above Item No 4 but except material , complete all as specified and directed.
49M&L for raised pointing to rubble or polygonal rubble, uncoursed or brought up to coarse with CM 1:3 complete all as specified and as directed
50M&L for concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) in foundation, filling and mass concrete all as specified and directed.
51M & L for RCC ( Nominal mix ) 1:2:4 Type B-1 using 20mm graded crushed stone aggregate as in foundations, plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified.
52M & L for Formwork to sides of footings, plinth beams; and similar work; vertical or to batter all as specified.
53M & L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified.
54M & L for Mild steel bars 6 to 8mm mm dia for stirrups cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified.
55Material and Labour for PCC (1:2:4) type B1 using20 mm graded crushed stone aggregate as in coping, mud stops, benching, water tank platform etc.on roof, chajja weathering, slightly rounded or chamfered angles and throatingetc. including necessary form work complete as directed.
56M & L for Rendering 15mm thick cement mortar in 1:4 on fair faces of brick work or concrete surfaces even and smooth without using extra cement.
57M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Cement Base Paint of approved tint over a coat of priming on plastered and other surfaces with alkali resistant priming paintcomplete all as specified
58M&L for Preperation of old decorated wall surfaces including brooming down or steel wire brushing, scraping down smokes soot, module, moss and effloroscent salts, trading oil and greasy spots and applying one coat of cement based paint on walls complete all as specified.
59S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengthsi.e. within 20mm of the length indicated) coforming to Fe 410 -W (Gde E-250) Quality -Aall as specified and directed.
60Dismantling barbed wire fencing of any description complete all as specified and as directed
61S & F for Galvanised 2 strand, steel barded wire 2.24mm dia barbed with 2mm dia barbs at 75mmmm spacing and straining and fixing to any type of strandard rails straning bolts, incl, securing or tying at crossings with and provision of galvanised mild steel, wire staples or steel pins etc complete all as specified and directed. (each line wire to be measured separately).
62Restraining and rescuring including making good staple of Galvanised 2 strand, steel barded wire 2.24mm dia barbed with 2mm dia barbs at 75mmmm spacing andincluding securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins,etc complete all as specified and directed. (each line wire to be measured separately).
63S&F for zinc coated Concertina coil (dia appox 610 mm) with core wire of thickness 2.60 mmhaving tensile strength not less than 1650 N/Sqmmand zinc coating 230 GSM and 0.5 mm thick cold rolled carbon striphaving 50 numbers of spiral turns having zinc coating 120 GSM with 125 clips per coil of 1.6 mm thickness .The approximate weight ofConcertina coil shall be 8.50 Kg per Running Metre and could be stretched to cover a distance of 6 to 7 running metres fixed at 3.00 m height wall on angle iron Y shaped which is placed 2.40 m to 3.0 m above the ground level complete all as specified and directed. Note- The measurments shall be recorded for the stretched length of Concertina coil.The contractor shall quote his rate accordingly. (The contractor shall submit test certificate from Govt approved Labortory for Concertina coil)
64Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil all as specified.
65M&L Cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in surface channels, drains etc.
66Extra for forming fair finished drain or channel up to 55 cm inner girth in cement concrete, using extra cement incl forms, moulds, mitred/stopped ends etc.
67M & L for framed work such as grill, gratings, etc with ends of bars shoulderedand /or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work corn-conforming to Fe.290. Gde -E-165, complete all as specified and directed.
68Demolition of Concrete of any description (reinforced) and in any position not otherwise specifically provided for all as specified.
69M & L for Providing precast cement concrete type B1 1:2:4 (20mm graded aggregate) set in cement mortar 1:4 incover slabs (for man holes etc.) and similar articles with plain faces all as specified and as directed.
70M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade with grey cement and pigment complete all as specified and directed.
71M&L for chequered cement concrete tiles 30cmx30cmx25mm thick,set,jointed in neat cement slurry in floors with grey pigment cement and pigments.
72Supply only chain link fencing ,any size or type
73Fixing only chain link fencing including line wires,any mesh,size and type to any type of standards,rails,starining bolts,etc. including provission of binding wire.
74S&F MS works in posts and struts in fencing including cutting tops to shape as directed,drilling holes,including all necessary drilling,bolting or reveting,etc,and similar wark conforming to Fe-290 Gde E-165 complete all as specified and directed.
75Returning, filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm thick each complete in hard/dense soil.
76Removing excavated material n,exc 50 Mtrand depositing where directed at a level of n,exc 1.5 m above the strating point in soil.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail