Tender For Repair And Maintenace Of Winter Appliances Like Electric Geyser, Solar Water Heater And Misc Other E/M Items At Af Stn Bhuj, bhuj-Gujarat

Military Engineer Services-MES has published Tender For Repair And Maintenace Of Winter Appliances Like Electric Geyser, Solar Water Heater And Misc Other E/M Items At Af Stn Bhuj. Submission Date for this Tender is 11-07-2023. Solar Heater Tenders in bhuj Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

38193796
Corrigendum : Tender For Repair And Maintenace Of Winter Appliances Like Electric Geyser, Solar Water Heater And Misc Other E/M Items At Af Stn Bhuj
Open Tender
Indian
Gujarat
bhuj
11-07-2023

Tender Details

Repair And Maintenace Of Winter Appliances Like Electric Geyser, Solar Water Heater And Misc Other E/M Items At Af Stn Bhuj

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR AND MAINTENACE OF WINTER APPLIANCES LIKE ELECTRIC GEYSER, SOLAR WATER HEATER AND MISC OTHER E/M ITEMS AT AF STN BHUJ
Sl. No. Item Description
1Servicing of solar water heater upto 100/200 Ltrs capacity including checking serviceability of individual components and replacement of worn out fastners,gaskets,washers accessories,inspection of the entire system,cleaning of Sacrificial anode,rectification of any leaks,tightening of electric loose connections etc. and making system operationalcomplete all as specified and directed by Engineer-in-Charge.
2Material & labour for removing old broken/damaged solar water evacuated vacuum tube and supply and fix in replacement solar water evacuated vacuum tube model no. 58*1800 mm,inner tube of outer surface coated with (Al-N-Al) for excellent solar radiation and absorption high efficiency three layers tube for 100 LPD with proper airtight rubber white o ring and black o ring washer and whichever be required to make servicable of this item complete all as specified and directed by Engineer-in-Charge.
3Supply & laying of 20mm outer dia CPVC pipes SDR 11 including plain CPVC fittings on walls/ceiling or laying in floors complete all as specified and directed by Engineer-in-Charge.
4Supply & laying GI pipe "medium grade" with all fittings and fixed to walls and ceiling or laid in floors of size 15 mm dia complete all as specified and directed by Engineer-in-Charge.
5Supply & fix in replacement PVC tank of capacity 200 ltr (cylindrical vertical with closed top) fixed in position complete all as specified and directed by Engineer-in-Charge.
6Supply & fix in replacement 20mm bore float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screw for iron pipe brass ferrule (Minium weight 210 gm complete with all fittings complete all as specified and directed by Engineer-in-Charge.
7Supply & fix in replacement of 15mm bore bib taps ISI marked cast copper alloy fancy type chroumium plated with crutch butterfly handle screw down for iro n pipe or brass ferrule complete all as specified and directed by Engineer-in-Charge.
8Supply & fix in replacement of 15mm bore angle cock ISI marked cast copper alloy fancy type chroumium plated with crutch butterfly handle screw down for iro n pipe or brass ferrule complete all as specified and directed by Engineer-in-Charge.
9Material & Labour for disconneting electrically and mechanically the existing geyser of any description, any capacity and make/type and in any position for repair/replacement/painting/cleaning etc including disconneting existing cold and hot water pipe connections, strip opening of geyser for descaling of tank element, thermostate,inlet/outlet water pipe connection etc using suitable chemical/wire brush,replacement of unserviceabe parts, re-assembling the same after,repair/descaling, fixing in position including, connecting inlet/outlet water pipe connection, electrical connections any testing of geyser complete all as specified and directed by Engineer-in-Charge.
10Supply & fix in replacement electric heating element of the following ratings at site including rubber ring washers ISI marked complete all as specified and directed by Engineer-in-Charge.
112.00 KW
123.00 KW
132.00 KW suitable for racold/ bajaj geysers
14Supply & fix in replacementthermostat 40-90 degree centigrade vering capacity for the geyser of the following capacity 25/50 ltrs duly ISI marked complete all as specified and directed by Engineer-in-Charge.
15Supply & fix in replacement apparatus plate assy with inlet, outlet and thermostat pipes with drain plug and screws for fixing the element inclusive of clamps for holding the elementwith nut and bolts (Syphon assebly) suitable complete all as specified and directed by Engineer-in-Charge.for following :-
1603 ltrs
1725 ltrs
1835/50 ltrs
19Supply & fix in replacement for safety valve/high pressure valve ISI marked for geyser 25/50 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge.
20Supply & fix in replacement for PVC connection with brass nipple 15 mm x 450 mm long for geyser 25/50 ltrs capacity as per sample complete all as specified and directed by Engineer in Charge.
21Supply & fix in replacement for indicating lamp round / flat type as requiredfor geyser 25/50 litres capacity as per sample complete all as specified and directed by Engineer-in-Charge.
22Supply & fix in replacement storage tank made out of SS tank (inner tank) suitable for following size of vertical geyser not less than 2mm thick complete all as specified and directed by Engineer-in-Charge.for following :-
2303 ltrs
2425 ltrs
2535/50 ltrs
26Supply & fix in replacement top cover /bottom cover for Geyser 25/50 Ltr capacity,as required on site duly painted with white enamel paint complete all as specified and directed by Engineer-in-Charge.
27Material & labour for gas welding /brazing/soldering to the inner storage tank /apparatus palte assembly to stop the leakage including testing complete all as specified and directed by Engineer-in-Charge.
28Material & labour for taking down rusted rag bolts from walls and supply and fix new MS rag bolts 6" long 10mm dia half threaded fixed with cement complete all as specified and directed by Engineer-in-Charge.
29Supply & fix in replacement metal plug top 20Amps 3 pin complete all as specified and directed by Engineer-in-Charge.
30Supply & fixing in replacement of LED Lamp, 5W ,type of cap B22, wideoperating Range 140 V -280V, Input current 15mA- 40mA, lumen 350-500, UV and IR free light, color temperature 6500K,Cool Day light, up to 85 % Energy saving over GLS,Life time > 20000 hr complete all as specified and directed by Engineer-in-Charge.
31Supply & fixing in replacement of LED Lamp, 7 W ,type of cap B22, wideoperating Range 140V -280V, Input current 08mA- 30mA, lumen 180-300, UV and IR free light, color temperature 6500K, Cool Day light, up to 80 % Energy saving over GLS complete all as specified and directed by Engineer-in-Charge
32Supply & fixingin repairs wall mounted decorative ultra slim LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 10 W 2 ft indoor decorative with 2 core copper wire from ceiling rose to light fitting etc complete all as specified and directed by Engineer-in-Charge
33Supply & fixingin repairs wall mounted decorative ultra slimLED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution18 W 4 ft indoor decorative with 2 core copper wire freom ceiling rose to light fitting etc complete all as specified and directed by Engineer-in-Charge.
34Supply & fix double doorSheet metal enclosures factory made DBsprotection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 Single pole and neutral 8 ways with 200 Amp rated bus bar 415 volts powder coated complete all as specified and directed by Engineer-in-Charge.
35Supply & fix double doorSheet metal enclosures factory made DBsprotection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 Single pole and neutral 4 ways with 200 Amp rated bus bar 415 volts powder coated complete all as specified and directed by Engineer-in-Charge.
36Supply & fix in replacement of isolators, MCBs, etc. In distribution board of the following rating and capacities and complete all as specified and directed by Engineer-in-Charge.
37MCB TPN 415 volts 100 Amps Capacity, 10 KA
38MCB TPN 415 volts 63 Amps Capacity, 10 KA
39MCB SPN of 240 volts 20/32/40 Amps Capacity, "C" series, 10 KA
40MCBSP of 240 volts 6-32 Amps Capacity, "C" series, 10 KA
41Material & labour for disconnecting,taking down & removing carefully the existing ceiling fan ,exhaust fans,wall mounted fans,pedestal fans of any description,any sweep and from any position/location,sealing the cable end,for repairs/servicing/overhauling properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust rust and assembling and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076, including replacement ofbushes, bearing and fan blades with new and testing after refixing at site complete all as specified and as directed by Engr-in-Charge. Note:Bushes, bearing, and fan blade measured and paid separately.
42Material & labour for taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire as approved by Eng-in-charge including insulating material such as illuminous paper,Letherized paper,cotton tape,glass sleeving,insulating varnish etc.and transportation to site after testing at workshop,connecting and testing on full load ,hanging/fixing the repaired fans in same position or at position as directed by engr-in-charge. as directed for the following fans:- (a) Rewinding of motor of ceiling fans 1200/1400 mm sweep complete all as specified and directed By Engr-in -Charge.
43Material & labour for taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire as approved by Eng-in-charge including insulating material such as illuminous paper,Letherized paper,cotton tape,glass sleeving,insulating varnish etc.and transportation to site after testing at workshop,connecting and testing on full load ,hanging/fixing the repaired fans in same position or at position as directed by engr-in-charge. as directed for the following fans:- (a) Rewinding of motor of exhaust fans of 300/450 mm Sweep complete all as specified and directed By Engr-in -Charge.
44supply & fix in replacement ballbearing suitable forceiling fan/exhaust fan/wall mounte fan/pedestal fan etc complete all as specified and directed by Engineer-in-Charge.
45Supply & fix in replacement gun metal bushes suitable forceiling fan/exhaust fan/wall mounte fan/pedestal fan etc complete all as specified and directed by Engineer-in-Charge.
46Supply & fix in replacement capacitor 2.5 mfd 250 volts complete all as specified and directed by Engineer-in-Charge.
47Supply & fix in replacement energy saving, evironment friendly, long life, corrosion resistent, impact proof, Mini LED building securitylight made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LEDs with secondary optics and IP 65 protection with LED 20 W light source including material & labour for suitable bracket made of 20 mm dia light grade GI pipe & MS clamps complete with nuts and bolts and washers complete all as specified and directed by Engineer-in-Charge.
48Supply & fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cablein flexible steel conduict with flame proof cable glandss complete all as specified and directed by Engineer-in-Charge.
49Supply & fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cablein flexible steel conduict with flame proof cable glands etc complete all as specified and directed by Engineer-in-Charge.
50Supply & fix flame proof and weather proof rotary type switch,16 Amps,230 Volts, AC single pole, (LM-6) aluminium alloywithflame proof cable entry glands CMRS certified,ISI marked complete all as specified and directed by Engineer-in-Charge.
51Pulling down the existing U/S wires of any type from concealedwiring carefully of aluminium point wiring (light, fan, bell, socket, power point etc.) with or without conduit, along with all connected accessories such as ceiling rose, switches, sockets, switch boards, fan regulator etc complete all as specified and directed by Engineer-in-Charge.
52Pulling outsub main wiring only any size of aluminium conductor cable PVC insulated with or without condiut complete all as specified and directed by Engineer-in-Charge.
53Material and labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through and including PVC CASING & CAPPING INCLUDING accessories etc including fixed to wall/ceiling including provision of 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed as earth wire continuity with wooden board (1st class teak wood) with laminated sheet top cover, 3mm thick complete all as specified and directed by Engineer-in-Charge. for:-
54One light point controlled by one, one way switch single pole piano type
55One Fan point controlled by one, one way switch single pole piano type
56One 3 pin 5 Amp socket outlet on the same board .
57One 3 pin 5 Amps socket out let on independent board
58One bell point controlled by one bell push on independent board.
59All as per item No.40 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board complete all as specified and directed by Engineer-in-Charge..
60Material & labour for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through and including PVC casing capingISI marked with accessories and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed.(Note: Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit)
61All as per item No 42 but with 4 sqmm copper conductor in existing conduit complete all as specified and directed by Engineer-in-Charge.
62Supply & fix metal clad enclosure pole and neutral with a two pin and earth plug and socket complete with one single pole MCB of 20 Ampscomplete all as specified and directed by Engineer-in-Charge.
63Supply & fix in replacement, switch piano type, 5 Amp. SP, one way complete all as specified and directed by Engineer-in-Charge..
64Supply & fix in replacement switch socket outlet, 5 pin, 5 Amp, piano type complete all as specified and directed by Engineer-in-Charge
65Supply & fix in replacement switch socket combination 2 in 1, 6 pin 5 and 15 Amp flush type universal complete all as specified and directed by Engineer-in-Charge.
66Supply & fix in replacement switch bell push, flush type, 5 Amp complete all as specified and directed by Engineer-in-Charge.
67Supply & fix in replacement of ceiling fan regulator electronic step type 1 to 5 steps complete all as specified and directed by Engineer-in-Charge.
68Supply & fix in replacement bell, AC, 230 V, SP, ding dong typecomplete all as specified and directed by Engineer-in-Charge.
69Supply & fix in replacement of LED garden light / post top of 25 Watt Integral pole mounted decorative LED with IP-65 protection complete fixed on existing post/New post with all assembly and electric connection with service wire complete all as specified and directed by Engineer-in-Charge.
70Supply & fixing in replacement of water heater storage type 25 Ltr, ratted wattage -2000 W, Voltage: -230V, ACfrequency (HZ): -50 phase: -Single auto cutoff,rust proof external body suitable for highrise building suitable for water pressure head upto 8 bars star rating (BEE): -5 complete all as specified and directed by Engineer-in-Charge. Note: Old unserviceable Water Heater will be deposited in MES store yard.
71Supply & fixing in replacement including testing of water heater/geyser of vertical type of capacity 6 Ltr, Rated 3000W,230V AC, 50Hz Auto cutoff with a high tech adjustable thermostat,multifuction saftey valve,Magnesium anode coated heating element, rust proof external body with unique polymer protective coated inner tank, red and green indicator lamp, suitable for highrise building suitable for water pressure head upto 8 bars ,high density & thick PUF that ensures energy efficiency and reduced electricity bills ,15 Amps heavy duty plug complete all as specified and directed by Engineer-in-Charge Note:-(i) The rate quoated shall be in including hanging of Geyser in wall with 2/4 nos of stainless steel fastner of suitable size no extra payment will be allowed to contractor in this regard. (ii) Old u/s ceiling fan to be deposited at AGE E/M store yard
72Supply & fix framed work as in stand,doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing as per required at site complete all as specified and directed by Engineer-in-Charge.
73One skilled electrician for attending emergent complaints i.e no light ,earth leakage,short circuit,neutral break,mains/submain/internal circuit of existing system for,making continious electric supply including carrying out minor repairs etc as required at sitefor making in order/functional complete all as specified and directed by Engineer-in-Charge. Note:- 1.Minimum One skilled electrician to be present daily during the contract period for rectified the above type complaints ,if complains are not rectified within same day Rs-200 per complaint will be deducted pertained to geyser.
Disclaimer :