| 1 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete. |
| 2 | Supplying and filling in foundation andbasement with filling m-sand in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification. |
| 3 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 4 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation - Plinth Beam |
| 5 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification |
| 6 | Plain Cement Concrete 1:2:4 (one cement, two fine aggregates and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour chargesetc., complete as per standard specification |
| 7 | Fabricating supplying and fixing of pre painted galvanized iron sheets with the following specification. The materials should be of PPGI tile profile with a red colour or any other approved design 0.47 mm thick 24 guage having width 1050 mm. The sheet should be G.I.base pre painted hot dipped galvanized iron sheet and to be fixed with shelf tapping screws,plastic washer.The washer and screws to be fixed by using minute power machine drilled with out damaging the sheets paint coating to be regular modified polyster coat with zinc coating of Z 120 GSM paint thickness the finish should be terra cotta finish like malabar mangalore tiles finish optional matt finish. The sheet to be fixed with making suitable corrugated,cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers. |
| 8 | Supplying and laying Rubberised interlocking Paver blockM40 grade Providing and laying of83mmthick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with stone dust cushion below the uniform shap of approvednon skitting surface in the top and the rate including levelling the base preparation ofpavers as sub base, stone dust cushion 150mm thick layingout of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,. |
| 9 | Brick work in CM 1:5 (one cement & five sand) using III class countrybricks of size 8 3/4\"X4 1/4\" X 2 3/4\" including finishing, curing, etc., complete complying with standard specification. |
| 10 | Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 11 | Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 12 | Dadooing walls withGlazed tiles of sizes 305mm X200mm X 6mm size of approved make and quality and colour l Set in cement mortar 1:2 (one cement ,two sand) over 10 mm base layer plastering and pointing with white cement neatly as directed. |
| 13 | Supplying and fixing in position White Glazed European Water Closet of best quality and approved make with 100mm \"P\" os \"S\"\" trap with Double flapped rigit P.V.C. seat cover with C.P. brass hinges with 12.5 litres PVC Low Level Flushing Tank with all internal fittings etc., complete complying with standard spoecifications,labor inclusive of fixing lowlevel flushing tank. |
| 14 | White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification. |
| 15 | Painting two coats with approved cement paint over existing painting wall surface.including all cost of materials,labours,cleaning, preparing the surface,etc.,Complete as directed by the departmental officers. |
| 16 | Painting two coats with Ready Mixed Enamel Paint over the old iron surface of approved quality and colour without priming coat.including the cost all materials,labours,etc.,complete, in all floors. |
| 17 | Renovation and moderenization Work For the Existing of LPG Crematorium With using of Existing Chimney and Trolley.The following tasks are included in it,the details of work items are as follows.including all cost of materials,labours,conveyance charges of materials at work site,etc..,complete as directed by the departmental officers. |
| 18 | Supply and fixing of High Pressure Tube Burner made of Heat Resistant Stainless Steel |
| 19 | Supply and Fixing of Manifold Suitable For 10 Nos of cylinders Connection |
| 20 | Supply and Fixing of Non-Return Valve For the LPG Cylinders |
| 21 | Supplyof High Pressure Hoses to connect Between the Regulator and Manifold |
| 22 | Supply and Fixing of Regulator suitable for LPG Cylinders |
| 23 | Supply and Fixing of High Pressure Regulator To control the pressure of the LPG |
| 24 | Supply and Laying of Pipe Lines from the Manifold to Burners |
| 25 | Supply and Fixing of 3 Nos High Pressure Leak proof stainless Steel Shut of Valves |
| 26 | Supply and Fixing of High Pressure Leak proof Brass flow control Butterfly type Needle Valves |
| 27 | Supply and Fixing of Fully Automatic monoblock Burner inbuild with combustion blower, Ignition Transformer, Flame Sensor and Solinoid Valve etc, |
| 28 | Replacement of Venturi Wet Scrubbing System with double stage and maintained the water column in the flue Duct |
| 29 | Duct Line from the Furnace to Scrubbing unit with using of insullation of 40mm thick for the heat desipation of the Duct Line |
| 30 | Duct Line from the Scrubber Unit to Induced Draft Blower with mild Steel Construction |
| 31 | Duct Line from the Induced Draft Blower to Chimney with mild Steel Construction |
| 32 | Replacement of 2Hp High presure Water Pump for the Scrubbing System with Water Line Works |
| 33 | Construction of Stainless Steel Tank for the Scrubbing System. The Capacity of Tank will be 2000 ltrs |
| 34 | Replacement of Damaged Main Door of the Cremation Chamber will be replaced with New Door including Insulation, and Front Covering of the Door |
| 35 | Removal of Damaged ID Blower and Replaced with 5Hp Induced Draft Blower |
| 36 | Demolishing of Damaged Cremation chamber and Re-Construction of Primary Cremation Chamber and Secondary Chamber with using of New Refractory Fire Bricks, Hot face Insulation bricks, Cold face insulations bricks, and top covering Slabs etc,.. The Primary Chamber Inner Size will be 940mm X 1100mm X 2300mm and the Secondary Chamber inner size will be 300mm X 300mm X 1200mm. The 7 Nos Body Resting Bricks will be Cast Iron Shapped Solid Stone |
| 37 | Painting of 100 feet height Chimney with heat resisting Aluminum paint (OR) Red and White Enamal Paint including Material Cost and Labour Charges. The Existing Cowl is Damaged Condition the same will be replaced with New Stainless Steel Cowl. |
| 38 | Add GST 18% |