Rural Development Government Departments Closing in 0 days TDR #38166386

Tender For Internal Electrification For Construction Of Balicherra Village Committee Office Under R.D. Kanchanpur Division During The Year 2023-24.

Issued by Government Departments · North Tripura, Tripura
Tender Value
88992
Estimated cost
Bid Submission
30 Jun 2023
0 days left
EMD
1780
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
North Tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Internal Electrification For Construction Of Balicherra Village Committee Office Under R.D. Kanchanpur Division During The Year 2023-24. Internal Electrification

BOQ

Name of the work: INTERNAL ELECTRIFICATION FOR CONSTRUCTION OF BALICHERRA VILLAGE COMMITTEE OFFICE UNDER R.D. KANCHANPUR DIVISION DURING THE YEAR 2023-24.
Sl. No. Item Description
1Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-.a) Short Point :-
2Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-Medium Point :-
3Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-Long Point :-
4Providing and fixing of 3 pin 6/10 amps plug point withmodulartype 6/10ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modularswitch board, earthing the 3rd pin etc. as required:-
5Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.2 X 1.5 sq mm
6Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. 2 X 2.5 sq mm
7Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.2 X 4 sq mm
8Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:-1 X 1.5 sq mm
9Supplying and fixing of the following sizes wooden switch boards with 3mm thick bakelite cover etc. as required.300mm x 380mm (12\" X 15\") :-
10Supplying and fixing of the following modular accessories including necessary connection etc. as required.4 step fan regulator (1M):-
11Supplying and fixing of the following modular accessories including necessary connection etc. as required.Blank plate (1M):-
12Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick i/c accessories and providing masonry enclosure withCIcover plate Size 12\"x 12\" having locking arrangement, alongwith20 mm dia (medium gauge) watering pipe including CC work etc as required:-
13Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required.
14Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.
15Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of4.06mm (8SWG) dia G.I./ Copper wire forearth connection from earth electrodes etc as required.
16Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W) : -
17Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:-
18Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-
19Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:
20Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-25 watt LED street light fixture with integral driver and secondary lens (IP 66):-
21Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
22Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
23Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-32 amps 240 volts DP main switch (rewireable):-
24Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required.(2+6) / 8way SPN MCB DB (double door):-
25Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required:-6 to 32 amps SP MCB:-
26Supplying & installation of RCCB (sensitivity 30mA to 300mA) of following ratings in the existing MCB DB including connection etc as required:-16 to 40 amps DP RCCB:-
27Supplying and laying of following sizes XLPE insulatedPVC sheathed copper conductor Un-armoured cableincluding necessary connection etc as required.3 core 1.5 Sq mm
28Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-25 mm dia

AI Tender Summary

OUR REF NO 38166386
AUTHORITY Government Departments
TENDER VALUE 88992
LAST DATE 30-06-2023
Authority
Authority Name Rural Development Department
Work Description Internal Electrification For Construction Of Balicherra Village Committee Office Under R.D. Kanchanpur Division During The Year 2023-24. Internal Electrification
Basic Detail
Tender No eDT35/EE/RD/KCP/DIV/2023-24
Bidding Type Tender
Location
City North Tripura
State Tripura
Key Dates
Publish Date 14 Jun 2023
Submission Date 30 Jun 2023
Open Date 30 Jun 2023
Finance
Tender Value 88992
Tender Fee 1000
EMD 1780
Exemption Not Available
Document List
dcf05b2f-199c-4804-b485-c5b79eb41fa6.html
35EEDNIT.pdf
BOQ_39950.xls
DRAWING.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 14, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 30, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 30, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

dcf05b2f-199c-4804-b485-c5b79eb41fa6.html

pdf

35EEDNIT.pdf

xls

BOQ_39950.xls

pdf

DRAWING.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender