Tender For Soundproofing Paneling, Flooring Etc. At Community Centre, Sector 15, Chandigarh
Tender Value
3.16 Lakhs
Estimated cost
Bid Submission
21 Jun 2023
0 days left
EMD
6340
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Soundproofing Paneling, Flooring Etc. At Community Centre, Sector 15, Chandigarh
BOQ
| Sl. No. | Item Description |
| 1 | G.I. Earth pipe electrode without salt/ Charcoal:Supply and laying of earth electrode made out of ISI marked \"B\" class earthing with G.I. earth pipe 4.5 mtr long, 40mm dia including accessories, G.I. pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (without charcoal or coke and salt) as required. The earth electode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the Engineer-in-charge. |
| 2 | P/F 6 SWG GI earth wire in pipe: Providing & laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode, as required. |
| 3 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including 25 mm X 5 mm• G.l. strip in 40 mm dia G.l. pipe from earth electrode including connection with G.l. nut, bolt, spring, washer excavation and refilling etc.with charcoal/ coke and salt as required. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 4 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required |
| 5 | Wiring in existing conduit:Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. Universal/ Finolex/ Polycab/ KEI/ Havell\"s/ Cirtina or Technically equivalent. The specifications complete in all respect and to the entire satisfaction of Engineer-in-Charge. Size 1 x 1.5 mm2 |
| 6 | PVCCON S/F PVC Conduit:Supplying & Fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. The work shall be executed to the entire satisfaction of Engineer in charge. |
| 7 | 20 mm |
| 8 | 40 mm |
| 9 | Supply & Erection of of Brick Masonary Haudi of Internal finished size 2’ x 2’ x 2’ (deep) with Ist Class burnt bricks in cement sand mortar 1:5 ratio having 4½” thick wall. The top of the Haudi will be provided at the floor level with angle iron frame of size 40mm x 40mm x 6mm and shall be covered with a cover fabricated with Angle Iron Frame of size 35mm x 35mm x 5mm RCC casted with 8 Nos.MS Bar of suitable size. The haudi will be provided with 12.5mm thick cement plaster in 1:4 ratio complete in all respect as approved by the Engineer-in-Charge. The job also includes curing of the cemented/brick masonary work as per CPWD specification. |
| 10 | Supply and Erection of Double door type LT panel board (LOAD BANK 4 Way) of suitable size, dust and vermin proof, fabricated out of 1.6 mm thick CRCA sheet steel, powder coated with 7 tank process, for better environment protection. MCCB panel board should be manufactured and supplied by ISO-9001 certified OEM of MCCB. The bus bar system should be duly type tested at NABL accredited Lab for short time withstand current of 1 second. The panel board should be suitable for floor or wall mounting and should be of robust construction Type panel board should have cable alleys on both sides for easy cable termination and should be complete with Ammeter, Voltmeter, Selector Switches, Fuses, Indicating Lamps etc. of Make Havells Cat No- IHVG02500400 or its equivalent in ABB/ Schneider/ Legrand. The panel board should comprises of the following items (1) Copper Bus Bar of rating equal or higher than the incomer MCCB Current rating. (2) INCOMER - MCCB 100Amp, 3 pole, 26kA breaking capacity with adjustable thermal magnetic release -01 no. of make Havells CAT No. IHDA6OBT0100or its equivalent in ABB/Schneider/Legrand complete in all respect including incoming and outgoing spreader links.(3) OUTGOING- MCCB 63 Amp, 3 pole, 26kA breaking capacity with adjustable thermal magnetic release -04 nos. of make Havell\"s CAT No. IHDA6TBT0063 or its equivalent in ABB/Schneider/Legrand complete in all respect including incoming and outgoing spreader links.(4) Cable Alley on Both sides of make Havells Part no. ISSBOU0690 or its equivalent in ABB/ Schneider/ Legrand.(5) Digital Meter Module with Ammeter, Voltmeter, Selector Switches, Fuses and indicating lamps etc. of make Havell\"s Part No.ISSBOU0707 or its equivalent in ABB/Schneider/Legrand |
| 11 | S&E of Mouled Case Circuit Breakers (MCCB) of rating 100 Amp with Breaking Cap 16 kA, 415 Volts.Supply & Erection of 3 pole, 16 kA, 100 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge |
| 12 | F TPN MCB Supply and Fixing following rating, four pole, 415 volts, MCB TPN with box complete with connections tensing and commissioning etc as required. Make of Anchor, Havells, Legrand, ABB, L&T, Siemens. The work shall be executed to the entire satisfaction of Engineer in charge. 63 Amps |
AI Tender Summary
Tender Timeline
Jun 14, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedJun 21, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJun 21, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender