| 1 | For Feeders/BC/BT Ratio(800-400-200/1-1-1 A) |
| 2 | For 20 MVA T/F Ratio(400-200-100/1-1-1A) |
| 3 | 145 KV C.T. Junction Boxes |
| 4 | 36 KV Current Transformers |
| 5 | For Feeders Ratio(400-200/1-1A) |
| 6 | For 20 MVA T/F Ratio(800-400/1-1-1A) |
| 7 | 36 KV Junction Boxes |
| 8 | 145 KV Potential Transformers |
| 9 | 145 KV PT Junction Boxes |
| 10 | 36 KV Potential Transformers |
| 11 | 36 KV PT Junction Boxes |
| 12 | 145 KV Isolators (MOTORISED) without Post Insulators |
| 13 | 145 KV Line Isolators with earth switch MOTORISED |
| 14 | 145 KV Bus Isolators without earth switch MOTORISED |
| 15 | 145 KV Tandem Isolators without earth switch MOTORISED |
| 16 | 36 KV Isolators with Post Insulators |
| 17 | 36KV Line Isolators with one earth switch |
| 18 | 36KV Bus Isolators without earth switch |
| 19 | 36 kV Drop Out Fuse Set with Post Insulators |
| 20 | 145 KV Post Insulators |
| 21 | 33 KV Post Insulators |
| 22 | 120 KV Surge Arrestors |
| 23 | 30 KV Surge Arrestors |
| 24 | Rotational under frequency relay panel as per Technical Specification of SAS |
| 25 | Simplex type Control & Relay Panels as per Technical Specification of SAS for 20 MVA, 132/33KV Power Transformer |
| 26 | Simplex type Control & Relay Panels as per Technical Specification of SAS for 132 KV Transfer Bus Coupler |
| 27 | Simplex type Control & Relay Panels as per Technical Specification of SAS for 132 KV Bus Coupler |
| 28 | Simplex type Control & Relay Panels as per Technical Specification of SAS for 132 KV Feeder |
| 29 | Triple Simplex type Control & Relay Panels as per Technical Specification of SAS for 33KV Feeders |
| 30 | Simplex type Control & Relay Panels as per Technical Specification of SAS for Substation Automaton Panel |
| 31 | Optical fibre required for SAS as per specn |
| 32 | Battery & Battery charger |
| 33 | 110 V, 200 AH Batteries Complete set |
| 34 | Battery Charger for 110V 200AH Batteries |
| 35 | 110V DC Distribution Board |
| 36 | 415 V AC Distribution Board |
| 37 | 415 V AC Lighting Distribution Board |
| 38 | Capacitor Bank and its Accessories |
| 39 | 2x5 MVAR, 33KV Capacitor Bank Unit |
| 40 | 36 KV VCB |
| 41 | 30 KV Surge Arrestor |
| 42 | 3-Phase Reactor |
| 43 | 36 KV CT Ratio (400-200/1-1A) |
| 44 | 36 KV Isolators with Post Insulators (LI) |
| 45 | 36 KV Isolators with Post Insulators (BI) |
| 46 | 36 KV NCT Ratio 5/1A |
| 47 | Simplex Type Control & Relay Panel |
| 48 | 36 KV, 3-Phase PT |
| 49 | 1.1 KV PVC FRLS Copper Control Cable |
| 50 | 2 core* 2.5 sq. mm. |
| 51 | 4 core* 2.5 sq. mm. |
| 52 | 6 core* 2.5 sq. mm. |
| 53 | 1.1 KV PVC FRLS AlluminiumPowerCable |
| 54 | 3.5 core * 400 sq. mm |
| 55 | 3.5 core * 95 sq. mm |
| 56 | 3.5 core * 50 sq. mm |
| 57 | Main & Aux Structures with MS angles, channels, plates, nuts, bolts, step bolts, U bolts, spring washers, etc.,and any other required material |
| 58 | 40mm MS Rod for MainEarthmat |
| 59 | 40mm diaMS Electrodes (3 M Long) |
| 60 | MS Flat for earthing |
| 61 | 75x10mm |
| 62 | 50x6mm |
| 63 | 25x6mm |
| 64 | ABT Energy metering panel with one main & one check rack |
| 65 | 0.2s accuracy class ABT Energy Meters |
| 66 | Conductors |
| 67 | ACSR Moose |
| 68 | ACSR Panther |
| 69 | 70 KN antifog disc insulators |
| 70 | Single Tension Fittings Suitable for |
| 71 | ACSR Moose |
| 72 | ACSR Panther |
| 73 | Single Suspension Fittings Suitable for |
| 74 | ACSR Moose |
| 75 | ACSR Panther |
| 76 | PG clamps suitable for - |
| 77 | Moose / Moose |
| 78 | Moose / Panther |
| 79 | Panther /Panther |
| 80 | Bus Post Clamps suitable for- |
| 81 | Panther |
| 82 | Twin Panther |
| 83 | Moose |
| 84 | Twin Moose |
| 85 | Fire Fighting equipments |
| 86 | Portable AFF mechanical foam type Fire Extinguisher complete with initial charge hose pipe and all other accessories and fittings as as per IS 1024 trolley mounted 45/50 lit. cap. |
| 87 | Supply of following fire extinguisher carbon dioxide as per IS specn. No. 2878/1986 and tech. specn. Enclosed. |
| 88 | 22.5 kg |
| 89 | 9kg |
| 90 | 4.5 kg |
| 91 | Supply of sand buckets as per tech. specn. |
| 92 | Supply of Stands for sand buckets suitable for 6 buckets as per tech. specn. |
| 93 | 63 KVA DG Set |
| 94 | G.I. perforatedtrays of various sizes for all cable trenches in switchyard, control roomincluding fixing. |
| 95 | Bay Marshlling Kiosk for 132kV Switchyard |
| 96 | Lighting and Luminaires |
| 97 | Supply of Complete fitting of Street Light Luminairs with LED Lamp 110 to 130 Watt, with all accessories (make Philips/CGL/Bajaj) Confirming to IP:65 |
| 98 | Supply ofComplete fitting of Post Top Lantern with all accessories with LED Lamp 40 to 45 Watt(make Philips/CGL/Bajaj) Confirming to IP:65 |
| 99 | Supply of 15W LED Lamp (make Philips/CGL/Bajaj) |
| 100 | Supply of Complete fittings of 18/20 Watt LED Tube Light (make Philips/CGL/Bajaj) |
| 101 | TESTING EQUIPMENTS (UPPTCL Approved make) |
| 102 | Digital Insulation Tester (provision for measurement of PI) |
| 103 | Earth Fault Detection Meter |
| 104 | Digital Multimeter |
| 105 | Fiber Optic Terminal Equipment (FOTE) SDH (STM-16) |
| 106 | Base equipment suitable for 04 directions in subrack fully equipped with all necessary common cards, power supply cards, other hardware & accessories including 10 Nos. optical patch cords of lengths as per site requirements, DDF etc. with redundant CPU. |
| 107 | Optical Base Card for 04 directions (STM-16) , should also support STM-1 & STM-4 interfaces. |
| 108 | Short Haul, STM-16, 1310nm SFP Transceiver - S16.1 |
| 109 | Long Haul, STM-16, 1310nm SFP Transceiver- L-16.1 |
| 110 | Long Haul, STM-16, 1550nm SFP Transceiver- L-16.2 |
| 111 | E1 Interfaces (120 Ohm) ( 32 Interfaces with 2 Cards) |
| 112 | L2Etherner Interfaces 10/100 Base T (16 Interfaces withminimum 2 cards) |
| 113 | VOIP Phone |
| 114 | Equipment cabinet for SDH and DTPC 2200mm (h) including 100mm base, w x d should be suitable for 19\" or23\" Rack(Alongwith 110V to 48V DC-DC Converter) |
| 115 | MDF (200 Pairs), mounted in cabinet |
| 116 | Air Conditioner (AC) Unit (Hitachi/LG/O\"Gen/Daikin/Voltas/Bluestar make) |
| 117 | 2 Ton, Window AC along with Stabilizer (5kVA) |
| 118 | 2 Ton, Split AC along with Stabilizer (5kVA) |
| 119 | TOTAL |
| 120 | Seal of Company |