Tender For Periodical Services To Certain Building Repair Cleaning To Sewer Line Repair Maintenance Of Dg Sets Centrifugal Pumps Sets Submersible Pumps Water Supply Lines And Allied Works In Sila Grn Hq 14 Sectt And Rr Units Under Age Reasi Of Ge N, nagrota-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Periodical Services To Certain Building Repair Cleaning To Sewer Line Repair Maintenance Of Dg Sets Centrifugal Pumps Sets Submersible Pumps Water Supply Lines And Allied Works In Sila Grn Hq 14 Sectt And Rr Units Under Age Reasi Of Ge N. Submission Date for this Tender is 08-07-2023. Diesel Generators Tenders in nagrota Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

38135764
Corrigendum : Tender For Periodical Services To Certain Building Repair Cleaning To Sewer Line Repair Maintenance Of Dg Sets Centrifugal Pumps Sets Submersible Pumps Water Supply Lines And Allied Works In Sila Grn Hq 14 Sectt And Rr Units Under Age Reasi Of Ge N
Open Tender
Indian
Jammu And Kashmir
nagrota
08-07-2023

Tender Details

Periodical Services To Certain Building Repair Cleaning To Sewer Line Repair Maintenance Of Dg Sets Centrifugal Pumps Sets Submersible Pumps Water Supply Lines And Allied Works In Sila Grn Hq 14 Sectt And Rr Units Under Age Reasi Of Ge Nagrota

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 82000.0 /-
Tender Value
INR 41 Lakhs /-

BOQ Items

PERIODICAL SERVICES TO CERTAIN BUILDING , REPAIR / CLEANING TO SEWER LINE , REPAIR/MAINTENANCE OF DG SETS CENTRIFUGAL PUMPS SETS, SUBMERSIBLE PUMPS, WATER SUPPLY LINES, & ALLIED WORKS IN SILA GRN, HQ 14 SECTT AND RR UNITS UNDER AGE REASI OF GE NAGROTA
Sl. No. Item Description
1SCHEDULE ‘A’ PART-I M &L Cleaning of sewage lines which are blocked /filled with sludge, semi solid/ material etc by roding manholes to manholes manually or by sewage cleaning machine without causing any damage to sewage line / manholes manholes covers taking out and refixing the covers and removing the sludge to a non inhabitant area or buried into ground all as specified for the 150mm internal dia of pipe complete all as speciffied & directed
2Cleaning of sewage lines which are blocked /filled with sludge, semi solid/ material etc by roding manholes to manholes manually or by sewage cleaning machine without causing any damage to sewage line / manholes manholes covers taking out and refixing the covers and removing the sludge to a non inhabitant area or buried into ground all as specified for the 100mm internal dia of pipe complete all as speciffied & directed
3M &L Cleaning of septic tanks, soakage well of any capacity andmanholes by Desludging / dewateringincludinginlet/ outlet chambers, removing out all scum, silt, residuals sludge (both organic and inorganic nature) after plugging the incoming sewage lines through combined high pressure water jetting cum suction (Vacuum) type machine mounted on LCV/HCV facility of high pressure vacuum and removing the same in the tank to a place outside cantonment at the place meant for the purpose by local municipality complete all as speciffied & directed
4M &L Cleaning of blockage of any type of WC (Indian/pedestal) from WC pan to Ist manhole in single storied bldg including resetting/ refitting of asccess door in soil pipe where opened without causing any damage to the wc pan "P" or "S" trap and pipe including fitting complete all as speciffied & directed
5M &L Cleaning of blockage of any type in Nahani trap provided in bath room, kitchen and indoor waste water pipe of kitchen sinks and WHB and removing all the sludge and foreign material from the trap and waste pipe from blocked trap to gully trap/ surface drain wherever opened or without causing any damage to the trap and pipecomplete all as speciffied & directed
6Taking up or down steel tubing and connection for 15mm tubing incl cleaning for refing or remova complete all as speciffied & directed .
7S&F GI tubing 15mm bore medium grade with all fittings fixed to wall, ceiling / floorcomplete all as speciffied & directed
8Taking up or down steel tubing and connection for 20 mm tubing incl cleaning for refing or removal complete all as speciffied & directed .
9S&F GI tubing 20 mm bore medium grade with all fittings fixed to wall, ceiling / floorcomplete all as speciffied & directed
10M &L Cleaning of service PVC service/over head tank cleaning process as under (a)Dewatering using submerssible pump/bailing out of water to dispose the minimum level of dirty water from the tank. (b)Cleaning the tank/ UG sump bottom, walls and ceiling using high pressure water jet to dislodge the algae calcinations, dirt etc. (c)Disposing the dirt water sludge etc., using specially designed sludge removal pump. (d)Cleaning the tank inside throughly by using industrial grade vaccum pump to make the tank inside free from dirt, algea and sludge etc. (e)Treating the inside walls, bottom, ceiling of tank including all nooks and corners by using and spraying anti bacterial agent such as hydrogenperoxide (bio degradable) for disinfection of tank inside. (f)Total disinfection and sterlisation of tank hyginecally cleaned and bacteria free and safeby Eco-Friendly for storage of water. Note :- Qty of tank are consider for cleaning twice in a Year and Date of cleaning to be written over head tank after cleaning.
11(a) For exc250 ltrsand not exc 500 ltrs capacity
12(b) For exc501 ltrsand not exc 1000 ltrs capacity
13(c) For exc 1001 ltand not exc 2000 lt capacty
14(d) For exc 2001 ltand not exc 5000 lt capacty
15S & F Rotational moulded polyethylene water 500 ltr Capacity storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I incl Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe 20mmdia . (Minimum weight2 0 m m - 2 1 0 g m s).Including taking down existing water tank and float valve complete all as speciffied & directed .
16S & F Rotational moulded polyethylene water 1000 ltr Capacity storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I incl ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe 20mm dia . (Minimum weight 210 gms).Including taking down existing water tank and float valve complete all as speciffied & directed .
17Supply & Fix in repairs brass of bore 20 mm bore float valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to iron pipe complete all as speciffied & directed .
18Supply & Fix in repairs brass of bore 15mm bore float valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to iron pipe complete all as speciffied & directed .
19S & F PVC (SWR) branch bends any radius 110mm bore of pipe in repairs complete all as speciffied & directed .
20S & F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or floors in repairs complete all as speciffied & directed .
21S&L in repair20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as speciffied & directed
22S&F as in repair Vitreous China Squatting pan, "Orissa" pattern, size 580 x 440 mm white with integral foot rests complete all as speciffied & directed .
23Supply & fixPVC flushing cisternlow level of capacity of 10 ltr, white, valve less symphonic action type complete with inlet ball valve float and handle or Push button type including brackets and fixed in repair complete all as specified & directed.
24S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm complete all as speciffied & directed
25Excavation in trenches in soft/ loose soil exc 1.5 m deep and getting out including forming bottom to required level or slop for laying pipe, concrete bed manhole etc n.exc 10 Sqm on plan complete all as specified (pipe and concrete bed shall be measured and paid separately ) complete all as speciffied & directed
26Returning filling in soft/ loose soil including spreading levelling ,watering and well ramming in layers not exc 25 mm thick complete all as speciffied & directed
27Removing of excavated surplas materials to a distanceexc 50 m but nexc 100 mm and depositing where directed a level n.exc 1.5 mtrs above the starting point complete all as speciffied & directed
28Demolitionorbreaking up 150 mm dia drain pipe including fittings of any desciption in any position and removing rubbish upto a distance of n. exc 50 mtr all as specified
29M&L for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 for 150 m bore of pipe complete all as speciffied & directed
30M&L Reinforced concrete pipes, class NP3, laid and jointed complete with collars 150 mm bore laid in trenches and jointed with CM 1:1 complete all as specified
31Demolition of brick work of any description and in any position built in CM and removing rubbish upto a distance of n exc 50 mtr complete all as speciffied & directed
32M&L for brick work built in CM 1:4 with sub class "B" bricks straight or curved on plan exc 6 m mean radius complete all as specified
33M&L for rendering 15 mm thick on fair faces of brick work internal faces in manhole in CM 1:4 using WPC as per manufacturer instruction incl finishing the surfaces even & smooth without using extra complete all as speciffied & directed
34M&L rendering 15 mm thick on other than fair faces of brick surfaces or concrete surfaces and finished surfaces even & fair in CM 1:6 complete all as speciffied & directed
35Supply only integral water proofing compound ISI marked complete all as speciffied & directed
36Demolition of reinforced cement concrete as in cover slabs of any description, removal of debris to beyond MD land complete all as speciffied & directed
37M&L for precast RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in manhole cover slab with plain fair faces and set in CM 1:4 all as specified
38M&L TMT mild steel bars 6 mm to 8 mm dia cut to length, bent to shape required, including cracking, bending,spirally for hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as speciffied & directed
39All as per Srl itrem No 38 above but10 mm dia MS round bar as in handle
40Taking down cement plaster on brick wall including racking out joints, hacking for key, scrubbing down with water etc,complete all as specified
41M &L Rendering 10mm thick on fair faces of brick work in cement mortar 1:6 finishing even and smooth without using extra cement upto any height, as in patches complete all as specified and directed.
42M &L Rendering 15mm thick on fair faces of brick surface in cement mortar 1:4 finished evenandsmooth without using extra cement, upto any height from GL, work to be carried out in patches complete all as specified and directed.
43M &L Rendering 10mm thick in CM 1:3 asin ceilings or concrete surfaces such as chajjas, upward facia, downward facias and similar items finished even and smooth including dubbing coat without using extra cement complete all as specified and directed.
44M &L Preparation of newly plastered surfaces of ceilling,upward facias etc and applying three coats of white wash complete all as specified and directed.
45M &L Preparation of newly plastered surfaces of wall and applying two coats of Oil bound distemper over one coat of primer complete all as specified and directed.
46M&L for preparing the external newlyPlasteredsurfaces of walls and applying twocoat of Cement base paint over one coat of chalk whiting complete all as specified and directed.
47M &L Preparation of old decorated surface of wallincluding brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, greasy spots and applying One coat ofOil Bound Distemper on wall complete all as specified and directed.
48M &L Preparation of old decorated surface of wallincluding brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, greasy spots and applying two coat ofOil Bound Distemper on wall complete all as specified and directed.
49M &L 3mm thick wall care putty on wallcomplete all as specified and directed.
50M &L Preparation of old decorated surface including brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, greasy spots and applying two coat of cement base paint on wall complete all as specified and directed.
51M &L Complete removal of existing treatment and applying two coat of apex exterior quality over a coat of primer complete all as specified and directed.
52Preparing Old steel painted surface to receive painting, including washing and cleaning, etc. over 10cm in width or girth, not otherwise described & applying one coats of synthetic enamel paint in any pattern complete all as specified and directed
53M &L Preparing Old wood and wood based surface to receive painting,including washing and cleaning, etc. over 10cm in width or girth, not otherwise described & applying one coat of synthetic enamel paint complete all as specified and directed.
54M &L Writing Building No/Block No with letters or figures (Block ,Roman,Italic or Indian ) N.exc 30 cm high including Oblitering old writing of any description n.exc 0.10 Sqm with synthetic enamel paint to match the existing surfaces complete all as specified and as directed by Engr-In-Charge. Note : Each Job Includes painting on required surfaces and writing of building/Block No Like P-5/01,NP-3/04,T-35
55M&L for maintenance and servicing of DG Set complete 62.5 KVA, Make: Kirloskar / Crompton Greeves installed at Mahore, Gool & Bagga at 58 RR including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draing out engine oil from the sump, flushing the sump thoroughly and replacing the fuel filter elements,oil filter element and cleaning of air filter all as required and filling the starting batteries with elecrtrolite to maintain the required specific gravity, applying the petrolium jelly in battery terminal poles, replacing the diesel tank level tube, cleaning the entire DG Set , checking of voltage, Hz, amps and adjusting fuel/ oil as required,overhauling of radiator assembly, Tightening the all bolts and nuts with replacement of warnout hose pipes and testing the DG set complete.
56All as per item No. 55 abovebut for DG set 30 KVA, Make: Kirlosker/ Mahindera &Mahinderainstalled atMahora, Bagga,Gool at units under HQ 58 RR. complete as specified and directed.
57Supplying and fixing in renewal sealed maintenance free lead acid battery 12 volt, 150 AH for DG sets installed at units under 58 RR. complete as specified and directed. Make - Exide Genplus or AMCO Insta Power or Amaron Quanta as approved.
58Supply and filling engine oil SAE 20 w- 40for DG setsat units under HQ 58 RR. complete as specified and directed.
59Supply and filling radiator coolant oil for DG setsat units under HQ 58 RR.
60Overhauling Fuel Injection Pump & Injectors by replacing the elements, D - Valves, O- rings, nozzles, bearing and gaskets and reassembling the new parts and calibrating in MICO test bench as per manufaturer specification all as directed for DG Set 30 KVA DG Sets installed at units under HQ 58 RR.
61All as per item No 60 abovebut for DG Set 62.5 KVA DG set installed at .units under HQ 58 RR.
62S& F in replacement of old unserviceable set of V-Belts and Supply and fix set of V-Belts for DG Sets30KVA to62.5 KVA installed at units under HQ 58 RR. complete all as specified and directed.
63S& F in replacement of old U/S Air cleaner elementof DG set 30 KVA-62.5KVA at units under HQ 58 RR. complete all as specified and directed.
64Supply and fix in replacement of old U/Shigh pressure copper tubes of required size from FIP to injectors for DG set 30- 62.5 KVA installed at units under HQ 58 RR. complete all as specified and directed.
65Supply and fix in replacement self starter assembly 12 volt suitable for 30 KVA DG set installed at units under HQ 58 RR.. complete all as specified and directed. Make: Kirloskar /Cummins
66All as per item No 65 above but for DG Set 62.5 KVA at units under HQ 58 RR.complete all as specified and directed. Make: Kirloskar/Cummins.
67Disconnecting the U/S burnt out self starter from DG set assembly,cleaning the slots,Rewinding with super enamelled copper winding wire of of suitable gauge,varnishing,drying and insulating with insulating materials and refixing the same and testing complete all as required and directed for DG sets 30 KVA to 62.5 KVA at units under HQ 58 RR.complete all as specified and directed.
68Disconnect,removing and Strip openingthe unserviceceable burnt out winding of the Stator of alternatorassembly of DG Set and rewinding complete with super enamelled copper winding wire of suitablesize including insulating material,drying,varnishing etc including transportation from site to contractor"s workshop and back to the site and refixing with engine all as required and directed for DG Sets 30KVA installed at at units under HQ 58 RRat any locations. complete all as specified and directed.
69All as per item No 68 abovebut of capacity 62.5 KVA .
70Supply and fixing in replacement on load change over switch 4 pole, 415 volt, 250 amps complete including making all incomming and outgoing connections complete all as specified and directed.Make -Havells Cat No. IHCNFO0200 or equivalent in L&T/Standardas approved.
71Supply and fixing in replacement on load change over switch 4 pole, 415 volt, 160 amps complete including making all incomming and outgoing connections complete all as specified and directed..Make -Havells Cat No. IHCNFO0200 or equivalent in L&T/Standardas approved.
72Supply and fixing in replacement automatic voltage regulstor (AVR) electronic suitable for DG set 30KVAinstalled at units under HQ 58 RR.at any locations.as per existing specifications complete all as specified and directed.
73Supply and fixing in replacement automatic voltage regulator (AVR) electronic suitable for DG set 62.5 KVA at units under HQ 58 RR at any locations.as per existing specifications complete all as specified and directed.
74Replacement of door hinges cast alloy of suitable sizefor silent DG set doors of capacity 30 KVA at units under HQ 58 RRas per existing specifications complete all as specified and directed.
75Supply and fixing in replacement of door lock cast aluminium of suitable sizefor silent DG set doors of capacity 30 KVA & 62.5 KVA installed at units under HQ 58 RR at any locations.as per existing specifications complete all as specified and directed.
76Supply and fix in replacementcontrol assembly (digital display) of DG set Panel of capacity 30 KVA &62.5 KVA any makeinstalled at units under HQ 58 RRat any locations complete with necessary electric connections including checking of all electric connections and make functional complete all as specified and directed.
77Supply and fix LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 / IP 66 protection complete all as specified and directed.
78Supply and fix LED floodlight fitting 120 Watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection with impact and corrosion resistant complete all as specified and directed.
79S&F in repair LED batten (1.2 m) made of CRCA sheet housing with a PC glossy difusser and mounting accessories duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 22 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95complete all as specified and directed.
80S&F in repair LED fixture 18 watt including connection all as per Philips LEDcat ref no. BN 021C LED20S PSU CDL/NW GR or equivalent in other specified make as approved. complete all as specified and directed.
81S&F in repair LED fixture 10/9 watt including connection all as per Philips LEDcat ref no. BN 021C LED20S PSU CDL/NW GR or equivalent in other specified make as approved. complete all as specified and directed.
82S&F energy efficient recessed mounted LED luminaire suitable for 2"x2" grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire as required. complete all as specified and directed.
83Material and labour for earthing with galvanised steel earth plate electrode60cmX60cmX 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to GI strip 32 x 6 mm with mild steel nuts bolts checknuts & washers and connected to equipment as directed incl funnel with Gi medium grade watering pipe 20 mm bore , wire mesh , charcoal or coke and commn salt in alternate layers of 15 cm compacted thickness all around the earth electrode with concrete pit in PCC 1:3:6 type C-1 with 50 mm thick precast RCC cover in PCC 1:2:4 type B-1 cover slab reinforced with 8 mm dia deformed bars @ 15 cm c/c with suitable handle of 10mm dia round bar , 40mm bore medium grade pipe for earth strip protection inclnecessary excavation and earth wok in soft / loosesoil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of MES SSR Part-I complete all as specified and directed.
84S&F in repairs tubes medium grade galvanised with required all new fitting ISI marked fixed on wall/floor with fixing arrangement of following sizes:-
8515 mm bore
8620 mm bore
8725 mm bore
8840 mm bore
8950 mm bore
9080 mm bore
91100mm bore
92S&F in repairs gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for iron pipes of following sizes :-
9315 mm bore
9420 mm bore
9525 mm bore
9640 mm bore
9750 mm bore
98M&L for framed work such as grill, gratings etc with ends of bars shoulders and/or riveted or forged into spikes, framed guardbars,barred iron doors, ladders,framed balusers, walk ways railings, framework or water tanks and similar work confirming to fe 290, Gde-E-165 complete as specified and directed.
99Supply and fixing in replacement of cast iron sluice valve class PN-1.0ISI marked, both ends flanged, stainless steel spindle, with iron wheel and necessary jointing materials, nuts & bolts, washers etc for making two flanged joints of following sizes as required complete as specified and directed.
10080 mm bore
101100 mm bore
102Supply and fixing CI foot valve80-100 mm size including lifting of pipes from sump and replacement of rusted flanges, nuts etc and refixing the same complete as specified and directed. Make: Kirloskar/Upadhyaya /Zoloto as approved.
103Construction of brick masonry valve pit chamber with 3 mm thick MS sheet cover and 40 x 40 x 6 mm angle iron frame embedded in PCC coping 1:3:6 type C-1 using 20 mm graded stone aggregates with locking arrangements of size 1200 mm x 1200 mm x1200 mm(internal size), depth 500 mm, brick work in cement mortar 1:4 using sub class ‘B’ (old size) bricks, internal walls plastered with 15 mm thick cement mortar 1:4 and finishing the surface even and smooth using extra cement, 40 mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate in coping, PCC 1:4:8 type D-2 using 40 mm graded stone aggregates in foundation 75 mm thick with and including necessary excavation & earth work in soft / loose soil complete as specified and directed.
104M&L forDisconnecting and liftingthe existing non functional submersible pump sets with dismantling existing bend from non return valve, removing and lifting out submersible pump sets of any description and capacity and in any position alongwith existing column pipe 80mm dia and submesible cable of any size from borewell 150/200mm (approx 30mtr depth of pumpset from GL) complete as specified and directed..
105M&L forLowering down the serviceable submersible pump sets of any description and in any position and in any capacity in borewell alongwith the column pipe 80mm dia and submersible cable of any size complete all as directed and making necessary electric connection and testing complete after lowering complete as specified and directed..
106M&L forDismantling and strip opening of submersible pump and motor of any description and in any position, transporting to workshop for servicing, overhauling, cleaning,greasing,removing andreassembling the pump and motor with proper alignment of both pump and motor, fixing in position connecting to existing system and testing at site on full load to the entire satisfaction of the Engr-in-charge for thepumps 20/25 HP, 3 phase, 415volts,50Hz AC Supply.Note : (I)The replacement of defective non functional parts shall be measured and paid for separately under respective item of sch A. (ii) The rate of above item shallbe deemed to include transportation to and from of pump, motor to workshop as approved by Engr-in-charge for necessary repair, alignment and testing of pump and motor at workshop.
107Supply only following parts of submersible motor of any description of capacity 20/25HP complete as specified and directed.
108Gun metal bush
109Rubber bush
110Brass thrust plate
111CI thrust bearing
112CI thrust casing
113Water seal
114CI lower/upprr housing of shaft
115Rotor sleeve
116Supply and fix in replacement the following parts of submersible pump of any description 20/25 HPcapacity complete all as specified and as directed.
117Coupling set with key of stainless steel
118Discharge outlet CI
119Stage casing CI
120Gun metal sand guard
121Gun metal neck ring
122Gun metal impeller
123M&L for repair to impeller of submersible pump of any description by breazing, welding, metalling, turning and polishing ofcapacity 20-30 HP complete as specified and directed.
124M&L for rewinding of submersible motor 20-30 HP with PVC insulated copper winding wire of existing size and approved make after taking down burnt winding, cleaning of slots with CTC solution, transportation at site, fixing in position and testing complete all as specified and as directed.
125M&L for GI Bend suitable for 80 mm bore column pipe heavy duty flanged and drilling at both the ends with having arrangement of mounting pressure gauge complete as specified and directed.
126M&L for column pipe 80 mm bore heavy duty ISI marked confirming to IS-1239 for column pipe 3 mtr length, both end flanged. complete as specified and directed.
127Dismantling and removing existing non functional 20-30 HP centrifugal pumpsets of any description, dismantling and strip opening,overhauling , cleaning, greasing and replacement of unserviceable/worn out spare parts and reassembling, re installation at site and testing complete all as specified and as directed. Note :-Replacement of U/S parts will be measured and paid separately under respective item of sch A
128M&L for rewinding of centrifugalmotor of any make and capacity 20-30 HP with super enamelled copper conductor of existing size of approved make after dismantling from foundation, cleaning slots with CTC solution including transportation to workshop and return to site after repair, refixing in position and testing on full load complete all as specified and as directed.
129Supply only following spare parts of 20-30 HP centrifugal pump.
130CI gland plate set
131Ball bearing for pump/ motor 20-30 HP Make: TATA/SKF/NBC
132CIcoupling set flanged type with rubber insertition and suitable bolts complete all as spd
133MS stud with nuts & bolts size 3/8"X2
134Turning and polishing of pump shaft
135CI Impeller
136Supply and fixing in replacement of following parts of booster motor capacity 20-30 HP complete as specified and directed..
137PVC fanincluding tapping for fixing of fan
138MS terminal box with insulated plate and studs
139M&L forCleaning of underground sump, removing sludge / dirt / sand by means of manual wash out, outlet cleaning from inside with bleached water and washing with sodium hydrochloride liquid, drying and applying one coat of lime wash internally and spraying anti bacteria liquid, writing date of cleaning on outer wall of sump with white paint on black base for 45000 litre capacity complete as specified and directed.
140M&L forCleaning of Steel Over Head Reservoir (OHR) approximately 18 mtr staging, 32000 Ltr capacity, removing sludge / dirt / sand by means of manual wash out, outlet cleaning the overhead reservoir from inside with bleached water and washing with sodium hydrochloride liquid,spraying anti bacteria liquid, writing date of cleaning on outer wall of overhead reservoir with white paint on black base complete as specified and directed.
141M&L forTesting of collected water sample from NABL lab from Peer baba in period of one quarter from all necessary perameters as directedcomplete as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail