Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-06-2023 | Date Corrigendum | Date | 29-06-2023 |
| Sl. No. | Item Description |
| 1 | APPENDIX-A |
| 2 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar ( D S R2016 ,15.7.4 ) |
| 3 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - inChargeNominal concrete 1:4:8 or leaner mix (i/c equivalent design Mix) ( D S R2016 ,15.2.2. ) |
| 4 | Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.(D S R2018,- 15.3 ) |
| 5 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the crosssectional area of R.C.C. or R.B. work) as per direction of Engineerin-charge. (2018D S R, 15.5) |
| 6 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.(D S R 2016,15.56 ) |
| 7 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including Chowkhats, architrave, hold fasts etc complete and stacking within 50 metres leadOf area 3 sq. metres and below( D S R15.12.1.) |
| 8 | Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm( D S R2016,15.23.1) |
| 9 | Dismantling Aaluminium/Gypsum Partitions,doors, windows, Fixedglazing and False ceiling including disposal of unserviceable surplusmaterial and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. (D SR 15.57) |
| 10 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the materials within 50 metreslead of Asbestos sheet ( 2018 D S R , 15.28.2.) |
| 11 | Dismantling steel work in built up sections in angles, tees, flats and channels including all guzzet plates, bolts nuts, cutting rivets, welding, etc. including dismembering and stacking within 50 metres lead( 2018D S R,15.18.) |
| 12 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. Ordinary rock( D S R2018 ,2.7.1) |
| 13 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.(D S R2016-2.25) |
| 14 | Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade ( OBSEVEDDATALSGD51.2.3) |
| 15 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).( 2018D S R, 4.1.8.) |
| 16 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).(D S R4.1.5) |
| 17 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)( 2018 D S R,5.1.2 . ) |
| 18 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)( 2018D S R , 5.2.2. ) |
| 19 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo - Mechanically Treated bars of Grade Fe 500 Dormore . ( 2018D S R,5.22A.6) |
| 20 | Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). ( 2018D S R , 5.3. ) |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. ( 2018D S R,5.9.1. ) |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers. ( 2018DSR,5.9.5. ) |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts. (2018D S R , 5.9.6. ) |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform.(2018D S R,5.9.3) |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form for : Stairs, (excluding landings) except spiral-staircases. ( 2018 D S R, 5.9.7. ) |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form for :Weather shade, Chajjas, corbels etc., including edges ( 2018D S R, 5.9.19) |
| 27 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete(ObservedDataBuildings 50.6.2.1.) |
| 28 | Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete(ObservedDataBuildings 50.6.2.2.) |
| 29 | 12 mm cement plaster of mix :1:4 (1 cement: 4coarse sand)(D S R13.4.1.) |
| 30 | 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand)D S R13.7.1 ) |
| 31 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : |
| 32 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.( D S R10.2.) |
| 33 | Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes ( D S R10.16.1) |
| 34 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(D S R 12.50) |
| 35 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Flashings/ Aprons.( Upto 600 mm)( D S R12.51.2.) |
| 36 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.(D S R9.48.2) |
| 37 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishingand making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railingwith necessary accessories & stainless steel dash fasteners , stainlesssteel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall beconsidered excluding fixing accessories such as nuts, bolts, fastenersetc.).( D S R10.28) |
| 38 | Providing and fixing plain multipurpose cement board(Hight pressuresteam cured) with suitable screws for cement particle board in ceiling, partitionetc. complete (frame work to be paid seperatately). 8 MM thick Cement fiber board as per IS: 14862(DSR12.26.1) |
| 39 | Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete. 125x65x2.12 mm (2018D S R,9.57.1.) |
| 40 | Providing and fixing aluminium sliding door bolts, ISI marked anodised(anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm( D S R 9.96.1.) |
| 41 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm (D S R9.97.2.) |
| 42 | Providing and fixing Aluminium Handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm(D S R9.100.1.) |
| 43 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (D S R2016, 11.41 .2 ) |
| 44 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxygrout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardenerand 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm ( D S R11.48.2. ) |
| 45 | Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. completeat all levels.Granite of any colour and shade ( D S R8.2.2.2.)Area of slab over 0.50 sqm |
| 46 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: Gypusm Plaster Board of size 1200 x 2400 x 12.5 mm, with all 4 side tapered ( D S R2016 12.45.1. ) |
| 47 | Designing, fabricating, testing, installing and fixing in position CurtainWall with Aluminium Composite Panel Cladding, with open groovesforfor linear as well as curvilinear portions of the building , for all heightsand all levels etc. including: ( D S R25.7. ) |
| 48 | Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface : Water thinnable cement primer (D S R13.43.1 ) |
| 49 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work.( D S R13.60.1.) |
| 50 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work.( D S R13.61.1 . ) |
| 51 | Removing dry or oil bound distemper, water proofing cement paintand the like by scrapping, sand papering and preparing the surfacesmooth including necessary repairs to scratches etc. complete(D S R201813.91 ) |
| 52 | Providing and applying Plaster of paris Putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete.( D S R 13.26) |
| 53 | Finishing walls with Acrylic Smooth exterior paint of required shade:Old work (Two or more coats applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface ( D S R13.111.1 ) |
| 54 | Wall painting with plastic emulsion paint of approved brand and manufactureto give an even shade : One or more coats on old work(2018 D S R 13.98.1) |
| 55 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work. ( 2018D S R,13.99.1 ) |
| 56 | Melamine polishing on wood work (one or more coat). ( 2018D S R,13.114) |
| 57 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work ( D S R2018 , 13.52.1) |
| 58 | Providing and fixing Aluminium work for Doors,Windows,Ventilatorsand Partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, free, straight, mitred and jointed mechanically wherever requiredincluding cleat angle, Aluminium snap beading for glazing / paneling,C.P. brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :For fixed portion - Polyester powder coated aluminium(minimum thickness of polyester powdercoating 50 micron) ( D S R21.1.1.3) |
| 59 | For Shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Polyester powder coated aluminium(minimum thickness of polyester powdercoating 50 micron) ( D S R21.1.2.3 ) |
| 60 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directionsof Engineer-in-charge . (Cost of aluminium snap beading shall bepaid in basic item):With float glass panes of4mm thickness(DSR21.3.1.) |
| 61 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directionsof Engineer-in-charge . (Cost of aluminium snap beading shall bepaid in basic item):With float glass panes of 8 mm thickness(DSR21.3.3.) |
| 62 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge.The elevational area of the scaffolding shall be measured for payment purpose.The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .( D S R14.72 ) |
| 63 | Providing and fixing Double action hydraulic floor spring of approvedbrand and manufacture conforming to IS : 6315, having brand logoembossed on the body / plate with double spring mechanism anddoor weight upto 125 kg, for doors, including cost of cutting floors,embedding in floors as required and making good the same matchingto the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete asper the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mmthickness (D S R21.4.1.) |
| 64 | Supplying and Fixing Good Quality Stainless Steel DoorHandle ForGlass Doorof size45cm Withall necessary screws, nut boltsetccomplete as approved by the Engineer in Charge. ( Observed Data od 46046/2021-2022 ) |
| 65 | Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall(Observed DataBuildings50.18.7.4.2.) |
| 66 | Engaging Labour For Cleaning works / Repair Works - Beldar |
| 67 | Engaging Labour ForDismantling works / Repair Works-FitterGrade 2 |
| 68 | Engaging Labour For Maintenance works / Repair WorksCarpenter |
| 69 | Disposal of building rubbish / malba / similar unserviceable, dismantledor waste materials by mechanical means, including loading,transporting, unloading to approved municipal dumping ground or asapproved by Engineer-in-charge, beyond 50 m initial lead, For all leadsincluding all liftsinvolved. ( D S R201615.60) |
| 70 | Supplying fabricating and fixing in position Sales counterwithGranite /Glasstopof80CM TOP WIDTHANDHEIGHT80 CM ( AV ) ,made with frame work of 16 mm BWR(IS303GRADE )Plywoodincludingcoveringthe front and SIde , Providing inside Racks using16 mmBWR ( IS 303GRADE ) Ply wood,Coveringall the expsedsurface with 1.00 mmthickness decorative Laminatedsheet ofapproved brandwith suitable adhesive ( HEATEXor equvqlent ), the insideof the counter being painted with synthetic enamel paint 2 coat over one coat of wood primerand putty leveling, filling etc.Providing12 mm thicedgepolishedglass/18 mm thickegde polished Granite for the Top area with necessary glasscaps or adhesives, providing8 mm thickedge polished glass for the frontvertical area withsuitableDbrackets , Finishingincludingpolishing all the exposedarea completeas per the approved drawings anddirection of the Engineer in charge..(OBSEVED DATA od3_P100001/2019-2020 ) |
| 71 | Supplying fabricating and fixing in position Sales counterwithGranite /Glasstopof60 CM TOP WIDTHANDHEIGHT80 CM ( AV ) ,made with frame work of 16 mm BWR(IS303GRADE )Plywoodincludingcoveringthe front and SIde , Providing inside Racks using16 mmBWR ( IS 303GRADE ) Ply wood,Coveringall the exposedsurfaceusing 1.00 mmthickness decorative Laminatedsheet with Texture Finishofapproved brandwith suitable adhesive ( HEATEXor equvqlent ), the insideof the counter being painted with synthetic enamel paint 2 coat over one coat of wood primerand putty leveling, filling etc.Providing12 mm thicedgepolishedglass/18 mm thickegde polished Granite for the Top area with necessary glasscaps or adhesives, providing8 mm thickedge polished glass for the frontvertical area withsuitableDbrackets , Finishingincludingpolishing all the exposedarea completeas per the approved drawings anddirection of the Engineer in charge..(OBSEVED DATA od3_P100001/2019-2020 ) |
| 72 | Supplying and fixingModiguardorEquivalentBrand glass Mirror over Frame work of16 mmBWRQualityIS303Grade Play woodframe and covering the rear side with 12MM BWR plywood and finishingall theexposedsurfacewith1.00mmThicknessDecorativeLaminatedSheetsWith Texture Finishofapprovedbrandandshade, FixingonWall etc. complete as per the direction of Engineer in charge. |
| 73 | Providing and Fixingplywood Back groundpanel made out ofFRAMEworkusing16 mmBWRQUALITY( IS303grade )plywoodat suitable spacingboth horizontally and vertically, including making hole in the concrete/ masonry wall, with necessary SS hold fasts or SS screws of necessary size. ThenCommercialplywood12 mm thick B W R grade (IS 303 Grade )of approved make is fixed to the Exposedside of theframe work with screws of necessary size , all the exposed surface coveredby 1.00mmthickness Decorative LaminatedSheetswithsuitable adhesive ( Heatex or Equivalent )includingsealing all the joints and holes all as per the approved drawings andDirection of the Engineerin Charge . |
| 74 | Supplying fabricating and erectingin positionGODOWN RACKof 1.20m x 2.44 m x 0.40 m by using 12mm /16 mm /18mmthick commercial ply wood boardconforming to IS : 303 BWRGrade,16 mmthick 3 nos for vertical members,18 mm thick 5 racks horizontaland12 mm thick forback covring , allExposedsurface should be paintedwith 2 coat of Synthetic Enamelover a coat ofprimeretc. completeas per the approved drawings anddirection of the Engineer in charge. |
| 75 | Providing and fixing Wooden Display shelfwith frame work using16 mm thickIS303GRADEBWRPlywood ,covering the frame workwith16 mm thickIS303GradeBWRQuality ply wood,covering all the exposedsurface with1.00 mmthickness decorativelaminatedsheetwith Texture Finish using goodqualityaddhessive(HeatexorEquivalent)providing12mmthickedgemechinepolishedglass for rackswith necessary supports, all as per the drawing and Direction of theEngineer . |
| 76 | Providing M SDISPLAY RACKSin Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including weldinggrindingand bolted with special shaped washers etc. complete.Hot finished welded type tubes ( D S R10.16.1) |
| 77 | Providing and fixing8.00 mm thick FloatGlasspanesasracksinMSDisplayRacks , Display Standincludinggrindingandpolishing theexposed edgesetccomplete as per the architectural drawings and the directionsof Engineer-in-charge |
| 78 | Providing and fixing TEAK wood frame work consisting of battens 100 x 50mm ForFixed Glasing andDoor , fixed with rawl plug and drilling necessary holes for rawl plug etc. including Polishingcomplete.For Fixed Glased Partitions and Doors |
| 79 | Providing and fixingGlazingin woodenframesusing 12 mm TOUGHNED Glass of approved brandinFixed partitions and glazed shutters for doors, (Area of opening for panel inserts excluding portion inside grooves orrebates to be measured). |
| 80 | Providing and fixing Glazing in Aluminium Partitionsdoor, window and ventilator shuttersetc. with EPDM rubber / neoprene gasket etc. complete asper the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item): With TOUGHNED GLASS panes of 12 mm thickness |
| 81 | Providing and fixingKHADI SHELFHorizontal Spacing90 cmand vertical Spacing30 cm( except bottomshelf of 60 cmspacing)withstainless steel ( Grade 202 )Hollowtubes, channels, plates etc.,and8 mm Glass, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing theShelfto the Wall / Columns with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc.,Providing 8 mm Glass ofof required size, including polishing theexposed edges , allas per the Drawing andapproval ofthe Engineer-in-charge, |
| 82 | Providing and fixingDISPLAYSHELF, Horizontal Spacing90 cmand vertical Spacing45cm with40 MM AND25 MM M SHollowtubes, channels, plates etc.,and8 mm Glass, including welding, grinding, providing2 coats of primerand 2 coat of Epoxy Paint ( SPRAY fiNISH ) etccomplete,includingfixing theShelfto the Wall / Columns with necessary accessories & stainless steel dash fasteners ,Providing 8 mm Glass ofof required size, including polishing theexposed edges , allas per the Drawing andapproval ofthe Engineer-in-charge, |
| 83 | Providing and FixingplywoodSEATING SHELF withdrawyersof size 1.80 x 0.40 x 0.30mmade out ofFRAMEworkusing16 mmBWRQUALITY( IS303grade )plywoodat suitable spacingboth horizontally and vertically, includingcoveringall the exposed surfaceby1.00 mmthickness Decorative LaminatedSheets with Texture Finish withsuitable adhesive ( Heatex or Equivalent )includingproviding seating on topwith Granite of approved qualityall as per the approved drawings andDirection of the Engineerin Charge . |
| 84 | ProvidingTexture Workin Wall , Ceilingwith approvedbrand andDesign as approvedby theEngineer in charge. |
| 85 | ProvidingandFixingWALL PAPEROFAPPROVEDBRANDANDDESIGN asapprovedby theEngineerinCharge. |
| 86 | Providing and FixingplywoodRAISED PLATFORM ( 12 CM) made out ofFRAMEworkusing16 mmBWRQUALITY( IS303grade )plywoodat45 CMC/Cspacingbothways and fixing the same to floorwith necessary SS hold fasts or SS screws of necessary size. ThenCommercialplywood18mm thick B W R grade (IS 303 Grade )of approved make is fixed tocovertheframe work with screws of necessary size includingsealing all the joints and holes all as per the approved drawings andDirection of the Engineerin Charge . |
| 87 | ProvidingandFixingCARPET FLOORINGbywith good qualityandtexture carpet includingcost of all materialsandlabouras per approved Design |
| 88 | Providing Name Board by Vinyle Sticker Work on ExistingACPPANNEL WORK as per approved Design |
| 89 | EngagingLabourforMaintenanceworkElectrician |
| 90 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.GROUPB ( D S RELECTRICAL1.10.2) |
| 91 | Wiring for Twin controllight pointwith 1.5 sq.mm FRLS PVC insulated copper conductor singlecore cable in surface / recessed medium class PVC conduit,with2Way modular switch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable etc. as required. ( D S RELECTRICAL2016 1.11) |
| 92 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). ( D S RELECTRICAL1.31) |
| 93 | SUPPLY AND FIXING 1200 MM BATTEN LED LIGHT 20 WATTS WITH ALL NECESSARY FITTINGS (od15443/2021_2022) |
| 94 | Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. ( ODELECTRICAL90.4.8 ) |
| 95 | SUPPLY AND FIXING 250 MM EXHAUST FAN WITH NECESSARY FITTINGS( od15434/2021_2022) |
| 96 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 MM( D S RELECTRICAL1.21.1) |
| 97 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25MM( D S RELECTRICAL1.21.2) |
| 98 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm (D S RELECTRICAL1.17.3) |
| 99 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm(D S RELECTRICAL1.17.12) |
| 100 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm( D S RELECTRICAL1.17.21) |
| 101 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4x 6 sq. mm( D S RELECTRICAL1.17.31) |
| 102 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)( D S RELECTRICAL1.27.1) |
| 103 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)( D S RELECTRICAL1.27.2) |
| 104 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12Module (200mmX150mm)(D S RELECTRICAL1.27.6) |
| 105 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch(D S RELECTRICAL1.24.1) |
| 106 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TwoWay 5/6 amps switch(D S RELECTRICAL1.24.2) |
| 107 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch( D S RELECTRICAL1.24.3) |
| 108 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet(D S RELECTRICAL1.24.4) |
| 109 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet(D S RELECTRICAL1.24.5 ) |
| 110 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(D S RELECTRICAL1.26) |
| 111 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door(OD ELECTRICAL9.10.1.10 ) |
| 112 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SinglePole( D S RELECTRICAL2.10.1) |
| 113 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required (D S RELECTRICAL2.11) |
| 114 | Supplying and fixing following rating,Four pole,415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps(D S RELECTRICAL2.13.2) |
| 115 | Supplying and fixing following rating,Four pole, ( Three phase and neutral), 415volts, Residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63Amps(D S RELECTRICAL2.15.3.) |
| 116 | Providing and fixingFlexiLEDStrip for Cove Lighting 12 Wwith suitable Driveofaprovedbrand(Wipro/Bajaj/PhilipsOrEqivalent.) |
| 117 | Supply, conveyance installation testing and commissioning ofSleekCompactRecessMounting LEDSlimPanellight fitting3W/4W , square or round,Cool orWarm,size75 mm ( or nearest available)with light Weight Body,energy efficient drive ,complete with all accessories , fixingdirectly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required. |
| 118 | Supply, conveyance installation testing and commissioning ofSleekCompactRecessMounting LEDSlimPanellight fitting 6 W , square or round,Cool orWarm,size 105 mm ( or nearest available)with light Weight Body,energy efficient drive ,complete with all accessories , fixingdirectly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required. |
| 119 | Supply, conveyance installation testing and commissioning ofSleekCompactRecessMounting LEDSlimPanellight fitting 12 W , square or round,Cool orWarm,size 155 mm ( or nearest availablesize)with light Weight Body,energy efficient drive ,complete with all accessories , fixingdirectly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required. |
| 120 | Supply, conveyance installation testing and commissioning ofSleekCompactRecessMounting LEDSlimPanellight fitting 18 W , square or round,Cool orWarm,size 205 mm ( or nearest availablesize)with light Weight Body,energy efficient drive ,complete with all accessories , fixingdirectly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required. |
| 121 | Supply , conveyance, installation, testing and commissioning Wall mounting fan of400mmSweep withOscillation systemand Pull Cord, using mounting brackets supplied along with the fan and giving connection with existing wire. |
| 122 | Supplying installation testing and commissioning of2TonSplitAir conditioner ( INVERTOR AC ,FULL COPPER ) with remotecontrol of make Voltas / Blue Star / L.G /.Carrier or equivalent make with 1unit ofVoltagestabilizer ( V Guard VG500Stabiliseror Equivalent approved makesuitable for 2 Ton invertorAC ) ,providingangle iron / Wall MuntingBracketsupport to the out door and indoor unit , copper tube, cableetc complete. includingcutting andmakinggood of themasonrywall / concrete asdirectedby theEngineerinCharge . |
| 123 | Supplying , installing, testing and commisioningCCTVSystemwithCP Plus –2.40MP AHD IR D/N Dome Camera with 3.6 mm Lens,IR Distance 20 meter. 6 Nos ,CP Plus 8channel. Standalone DVR with TCP / IP / LAN / Eithernet, remote, channeling, playback, motion, mobile imaging, with out HDD.1 unit, A/C D/C Power supply 5 Amps SMPS -1,RCA/BNC Cable Connecters - 12 nos, 2TB HDD-1,1 18.5”Monitor , withCabling with 3+1 control cable and accessoriesas required |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy