| 1 | Schedule \"A\" |
| 2 | Dismantling of boards of any description fixed in any position with nails/screwincluding cover fillets complete all as specified and directed by Engr-in- Charge. |
| 3 | S&F in repairs forexposed GI powder coated snap grid frame work for false ceiling of grid size 600X600mm comprising of wall /cleat angle of size 24X 38X0.70mm with 4mm dia GI providing 4mm thick \"E\" board in ceiling with galvanised iron snap frame of \"T\" Section 24x38x0.70mm wall/cleat angle 25x25x0.35mm thick and hanging with 2mm GI wire all fixed arrangement will be done as per manufacture instruction and including two coat of oil bound distemper over a coat of primer complete all as specified and directed. |
| 4 | M&L for RAJSHRI brand insulated PVC wall panelling consisting of PVC insulated panels having wall thickness of 2mm (+or -0.2) PVC sheet opf density 600 Kg /CbmManufactured by an ISO-9001-2015 certified company, and the desired thickness of EPS ( Dependent on the insulation required) screwed into the wall using screws of adequate length. The screws shall be placed at a distance of 150mm and shall be 25mm from theedge of the insulated panelon all four sides of the panel. The PVC strips of 5mm ( + or - 0.25) thick PVC sheet of width 75mm feathered at the edges shall be stuck using solvent cement adhesive at the places where two panels are joined, so as to cover the screw of both panels, using solvent cement 900heat bent strips of 5mm thick PVC sheets of width 75mm x75mm feathered at the edges shall be stuck at wall joints / pillars etc. complete as per direction of Engineer -in- Charge, manufactures specification and drawings |
| 5 | M&L for RAJSHRI brand 22mm thick flase ceiling made of PVC insulated panels of size 600mm x600mm, wall thickness of panel 1.5mm (+ or -) 0.1 on both side on 22mm EPS panel 1.5mm (+ or -) Plain PVC sheet of density 600 kg / Cbm manufactured by an ISO -9001-2015 certified company is stuck on both side with adhesive . The panel is inserted in a frame made of anodised Aluminium T section of size 1\"x 1\" ( 25mm x25mm)in square type grid of size 2\"x2\" (600mm x600mm). The aluminium framework is supported from the ceiling with the help of \"j\" hook and G.I wire /6mm M.S. rods of required sizes to maintain proper level. The aluminium framework is supported on side wall with the help of aluminium \"L\" section size 1\"x1\" (25mm x25mm) angles complete as per direction of Engineer -in- Charge, manufacture\"s specification & drawings. |
| 6 | M&L for RAJSHRI Brand of 50mm thick semi height solid PVC partition consisting of 40mm sandwitch PVC panel made out of 36mm high density expanded polystyrene sheet ( EPS thermocol) stuck on both side with 2mm ( + or - 0.2mm) thick plain PVC foam sheets of density 600 kg /Cbm manufactured by an ISO -9001-2015 certfied company reinforced with frame work made from 35mm x 5mm M.S Angle in between two M.S. angle 5mm ( + or - 0.25mm) thick plain heat moulded PVC \"C\" Channel of size 50 x 100 mm with feathered edges shall be fixed on the floor & 50x75mm with feathered edges plain PVC \"C\" channel shall be fixed in top M.S frame work. Sandwich PVC panel shall be inserted in the top & bottom PVC \"C\" channel in between adjoining EPS sandwiched PVC partitions panel 5mm ( +or - 0.25mm) thick x 75mm width plain PVC sheet feathered at edges shall be stuck on front & back face using solvent cement etc in places where two partitions meet to from an \"L\" shape the panels are joined 5mm ( + or - 0.25mm) thick plain heat moulded PVC sheet \"L\" section of size 45mm x75mm with feathered edges shall be fixed on front & back side. This is done to maintain the symmentry of design. An additional 5mm (+ or - 0.25mm) thick PVC strip of 40mm width is to be stuck on the interior side of the \"C\" channel using PVC solvent adhesive complete as per direction of Engineer -in- Charge. |
| 7 | M&L for false ceiling with 12mm thick 600 x 900 mm size gypsum board fixed with machine screws on GI channel 18 gauge , thick grid work, main joists placed at 750mm centers , secondary joists placed at 450mm centers, GI angle suspenderd from roof and treating the sheets with Gypsum binder, sanding the surfaces till smooth surface is obtained including preparation of surface and applying two coats of luster paint over a coat of primer all as directed by Engineer - in - Charge. |
| 8 | Material and labour for plaster of paris decorative cornices/ moulding to the pattern as approved, cross sectional area exceeding 13 Sq.cm and not exceeding 25 Sq.cm and fixed in decorative pattern including preparation of surfaces and applying two coats of oil bound distemper over a coat of primer matching with the colour of ceilingincluding dismantling existing complete all as specified and as directed. |
| 9 | S&F in repairs 4mm thick ply wood grade BWR (type BB) fixed with nails to the timber frame work asin ceilingcomplete all as specified and as directed. |
| 10 | M&L forSecond class hardwood Weather boarding, clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give20mm laps and fixedcomplete all as specified and as directed. |
| 11 | Material and labour in repairs for 18mm thick plywood, grade BWR, type BB, number of ply 9 Nos, fixed with fevicol and nails for working table/ storage almirah,cabinets, cupboards, racks and wall panelling, to the size and pattern as directed including fixing on walls, floors etc. complete all as specified directed. |
| 12 | Material and labour inrepairs for 12mm thick plywood, grade BWR, type BB, number of ply 7 Nos, fixed with fevicol and nails for working table/ storage almirah, cabinets, cupboards, racks and wall panelling to the size and pattern as directedincluding fixing on walls, floors etc. complete all as specified and as directed. |
| 13 | Material and labour for 0.90mm thick decorative laminate type 1 of surface finish, colour, pattern and size as approved, fixed with approved adhesive as per manufacturer’s instructions on horizontal and vertical surfaces etc. complete all as specified and as directed. |
| 14 | Material and labour for 4mm thick one side decorative group match veneer complete all as specified and as directed. |
| 15 | Dismantling wrought iron or mild steel work of any description not otherwise provide complete all as specified and directed. |
| 16 | S&F Steel work in tubular trusses of any shape or size including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1998 grade St.-240 complete all as specified and directed. |
| 17 | S & Froof trusses(framed) trusses purling crane gantries of any shape or size, rails and fastenings and heavy bracket framing (beams,teeangle,channel or flate sections) including distance pieces,cleats confirming to fe 410-w(gde E-250quality etccomplete all as specified and directed. |
| 18 | M&L for Rolled Mild steel sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. complete all as specified and directed. |
| 19 | Demolition of cement concrete of any description and in any position not otherwise specifically providedcomplete all as specified and directed. |
| 20 | M& L for Making good under cills orover arches, lintels and bressummers. including all pinning, dismantlled portion of any typein CM 1:4 or plain cement concrete 1:2:9 as required thickness when necessarycomplete all as specified and directed. |
| 21 | M&L for providing cement concretetype B1 1:2:4 (20mm graded stone aggregate) as in roof kerbs or mud stops rounded or chamfered on edges and other similar bands ,plinth coureses parpets and railingup to 60 cm in height ,and as in copingscomplete all as specified and directed. |
| 22 | M&L for Cement concrete, (1:4:8) type D2 (using40mm graded stone aggregate)as in foundations, filling and mass concrete complete all as specified. |
| 23 | Taking down cement plaster of any thickness on brick or stone walls etc including raking out joints, hacking for key and scrubbing down with water built in cement mortar complete all as specified and directed. |
| 24 | M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layer of (10mm+5mm)mixed with water proofing compound in top layer @ 2% by the weight of cement or as per manufacture\"s instructions finishing the surface fair and even without using extra cement complete all as specified and as directed. Note :-(1) Use ofDimapur Sand to plaster.(2) WPCshall be measured and paid separately. |
| 25 | M&L for 10mm thick rendering in cement mortar 1:4 on plaster/concrete surfaces finished even in smooth without using extra cement complete all as specified and directed by Engr-in- Charge. |
| 26 | Supply only integral water proofing compound complete all as specified and directed. |
| 27 | Dismantling of plain or corrugated steel sheeting any gaugethickness including nainital or similar pattern on roof covering complete all as specified and directed. |
| 28 | S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mmthick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 29 | S&F pre- painted galvatume aluminum zinc coating GI basedsteel sheet 0.50mmthick of an colour having tensile strength of 550 Mpa as in ridge, fixed with self tapping screws complete all as specified and directed. |
| 30 | S&F 0.63 mm thick plain galvanised mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashing ofcoating 275 complete all as specified and directed. |
| 31 | M&L for Preparation of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote oilcomplete all as specified and directed. |
| 32 | M&L for preparation of new plastered surfaces of wall and applying two coats of Cement Base Paintover a coat of white wash complete all as specified and directed. |
| 33 | M&L for preparation of new plastered surfaces of walland applying two coat of Oil bound distemper over a coat of alkali resistant primer complete all as specified and directed. |
| 34 | M&L for preparation of old painted steel surfaces on roof (CGI/PGI) of any description and applying one coats of synthetic enamel paint over a coat of aluminiumred oxide paint complete all as specified and directed. |
| 35 | M&L for preparation ofold (existing) untreated surface of ceiling boardbysoft wire brushing rubbing down & applying one coat of Oil bound distemper complete all as specified and directed |
| 36 | M&L for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new or previously untreated wood surfaces of any description not other wise described over 10 cm with or girth complete all as specified and directed. |
| 37 | Dismantling of timper scantling40 sq .cm and over in section,in any position complete all as specified and directed |
| 38 | Dismantling timber scantlingsunframed works in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm complete all as specified and directed by Engr-in- Charge. |
| 39 | M&L for second class hard wood in scantling wrought, timber framed & fixed complete all as specified and directed. |
| 40 | Fixing only second classhard wood in scantling clean sawan , timber framed & fixed complete all as specified and directed. |
| 41 | S&F 2nd class hard wood plain fillets, square, rectangular in section, sectional areaexe 13 sqcm & n. exe 25 sqcm clean sawn, secured with nails or bradscomplete all as specified. |
| 42 | S&F 2nd class hard wood plain fillets, square, rectangular in section, sectional areaexe 6 sqcm & n. exe 13 sqcm clean sawn, secured with nails or bradscomplete all as specified. |
| 43 | Demolition of Brickwork or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars , etc, but excluding ashlar facings, dressed stone-work complete all as specified and as directed |
| 44 | M&L brick work with sub class ‘B’ bricks ( locally available best quality) old size bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 completeall as specified and directed. |
| 45 | M&L for brick work with sub class ‘B’ bricks ( locally available best quality) old size bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 completeall as specified and directed. |
| 46 | M&L for preparation of surfaces and applying Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqmcompleteall as specified and directed. |
| 47 | M&L for applying two coats of luster paint with roller finish over a coat of primer including removal of existing treatment with scrapping, rubbing , washingcompleteall as specified and directed. |