Tender For Repair Maint Of Central Package Ac Plants And Connected Works At North Side Runway Under Ge Nw Vasco, vasco-Goa

Military Engineer Services-MES has published Tender For Repair Maint Of Central Package Ac Plants And Connected Works At North Side Runway Under Ge Nw Vasco. Submission Date for this Tender is 15-07-2023. Air Conditioner Tenders in vasco Goa. Bidders can get complete Tender details and download the document.




Tender Notice

38116332
Corrigendum : Tender For Repair Maint Of Central Package Ac Plants And Connected Works At North Side Runway Under Ge Nw Vasco
Open Tender
Indian
Goa
vasco
15-07-2023

Tender Details

Repair Maint Of Central Package Ac Plants And Connected Works At North Side Runway Under Ge Nw Vasco

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Jul-2023 CORRIGENDUM-1 Date 08-07-2023
2 03-Jul-2023 CORRIGENDUM-2 Other 08-07-2023
3 08-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

NAME OF WORK: REPAIR /MAINT OF CENTRAL / PACKAGE AC PLANTS AND CONNECTED WORKS ATNORTHSIDE RUNWAY UNDERGE (NW) VASCO
Sl. No. Item Description
1M&L forcleaning of shell and tube water cooled condensersof the A/C plants of followingcapacities afterdismantling the water lines and headers and cleaning with suitable wire brush and washing soda to remove the dirt andwater scaling and refixing the water lines and headers including provision of new gaskets, etc for following AC plants complete all as specified and directed.
2(a) 02X30 TR capacity at OLD BMF AC plant
3(b) 03X48 TR capacity at EHU/ERS AC plant
4(c) 03X 20 TR capacity at EHU MIG AC plant
5(d) 02X37.7 TR capacity at BSF AC plant
6(e) 02X7.5 TR NAY (G) Store room AC Plant
7(f)04X60 TR capacity at Mig Simulator AC plant
8(g) 06X24 TR capacity at Mag Guard AC plant
9(h) 02X12.5 TR capacity at EHU NAY (G) AC plant
10Supply and charging compressor oil Servo manufacturedby Indian Oil Corporation or Equivalventapproved make including flushing/cleaning of oil chamber etc complete all as specified and directed.rge.
11Supply and fillingRefrigerant gas R-22 /Mafron -22 for AC plant compressor
12Supply and fillingRefrigerant gas R-407 for AC plant compressor
13Supply and fix in repairs ball /roller bearing for pumps and motors of following capacity including taking down old bearing and re installation at site including testing on completion complete all as specified and directed.
14(a) Upto10 HP capacity
15(b) 12.5 to 15 HP capacity
16(c) 20 HP to 30 HPcapacity
17(d ) 40 HP to 75 HPcapacity
18M&L for servicing monoblock pumps including dismantling and openingthe pump, repair/replacement of defective impeller,replace the worn out bearing impeller,stuffing box, back plates, gland packing mechincal seal and rusted nut, bolts etcassembling property , greasing all movable parts, fixing in position, testing and commissioning all as directed for the following HP pumps.
19(a) 3 HP to 5 HP Pump
20(b) 7.5 HP to 10 HP Pump
21(c) 12.5 HP Pumps to 20 HP pump
22Supply and fixing in repair power assembly expansion valve for 60 TR capacity at Mig Simulator AC plantas per sample and complete all as specified and directed.
23Supply and fixing in repair power assembly expansion valve for 30 TR capacity at Old BMF AC plant as per sample and complete all as specified and directed.
24Supply and fixing in repair power assembly expansion valve for 37.7 TR capacity at BSF AC plantas per sample and complete all as specified and directed.
25Supply and fixing in repair power assembly expansion valve for 24 TR capacity at Mag Guard AC plantas per sample and complete all as specified and directed.
26Supply and fix ofV-beltsize C 2650/ C-102 including taking down old belt .
27All as per item No- 11 as above but of size B-112 .
28All as per item No- 11as above but of size B- 82.
29All as per item No- 11 as above but of size B- 78.
30All as per item No- 11 as above but of size B- 88.
31All as per item No- 11 as above but of size B- 108.
32All as per item No- 11 as above but of size B-54
33All as per item No- 11 as above but of size B-52
34All as per item No- 11 as above but of size B-68
35Supply and fix in replacement of tyre type coupling suitable for 75 HP motor coupled with 60 TR Compressor all as specified and directed by Engr-in-Charge
36Supply and fix in replacement of High pressure control switch as per existing make and type at site complete all as specified and directed.
37Supply and fix in replacement oil pressure control switch as per existing make and type at site complete all as specified and directed.
38Supply and fix in replacement low pressure control switch as per existing make and type at site complete all as specified and directed.
39Supply and fixing in replacement of power contactor assemblycomplete 63 Amp , 50 KA, 415 V, complete all as specified and directed.
40Supply and fixing power contactorassemblycomplete MNX-25 as per cat No CS 94110 complete all as specified and directed.
41Supply and fixing power contractor assemblycomplete MNX-12with one NO and NCas per Cat No : CS94108 complete all as specified and directed.
42Supply and fixing power contactor assemblycomplete MNX 32
43Disconnecting wiring carefully and removing defective auxillary power contactor assemblycomplete and replacing by new one of same make and model , reconneting wiring and testing on completion .
44Disconnecting wiring carefully and removing defective auxillary power contactor assemblycomplete and replacing by new one of same make and model , reconneting wiring and testing on completion :
45All as per item No - 29 but as per cat No : 3U A 52-00-2B 12.5 to 20 amps type 3 NA with 1 NO+NC .
46Supply andfixing in replacement of ML1.5 power contactor with 2NO +2NC Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 robust and suitable for hostile applications, including standard Coil of operating voltage110V, 240V and 440V, 50 Hz .
47All as per item No 31.00 but ML 2 powercontactor.
48All as per item No 31.00 but ML 3 powercontactor.
49All as per item No 31.00 but ML 4 powercontactor.
50Overvload relay range 9-15 amps . L&T (MRP) suitable for ML-1/ML-1.5 contactor
51Overvload relay range 20-33 amps . L&T (MRP) suitable for ML-2/ML-3 contactor
52Overvload relay range upto 7.5 amps. L&T (MRP) suitable for MNX contactor
53Supply and fixing electronic timer ST 100 (3 to 10 Sec) 240V or as per existing . Make – L & TST80328OOOO or equivalent make as C & S. including taking down of old one.
54Supply and fixing in repair single phasing preventor Relay (Auto / Manual / Remote Reset Adj.preeventor complete all as specified and directed.
55Supply and fixingsingle phasing protection Relay 415 VAC, 3 PH 3 W,1 C/O complete all as specified and directed.
56Supply and fixing under voltage/overvoltage relay .240 VAC, 3 PH4 W,1 C/O complete all as specified and directed.
57Supply & fixing digital type ammeter panel mounting three phase LED type 96 x 96 mm square including taking down old meter complete all as specified and directed.
58Supply & fixing digital typervoltmeter panel mounting three phase LED 96 x 96 mm square including taking down old meter complete all as specified and directed.
59Supply and fixingcurrent transformer secondary current 5 Amps and primery current up to 60 Amps including taking down old current transformer complete all as specified and directed.
60Supply and fixingcurrent transformer secondary current 5 Amps and primery current up to 30 Amps including taking down old current transformer complete all as specified and directed.
61Supply and fixing in repair themometer suitable for condenser water line with suitable housing to mount in pipe line 0 – 100 deg C including taking down old themostat complete all as specified and directed.
62Supply and fixing indicator lamp assembly complete LED type suitable for the existing system supply voltage for the existing system supply voltage 230V / 440 V AC including taking down old lamp assembly complete all as specified and directed.
63Supply and fixing in repair of MCCB3 pole415 volts AC , 100 Amps breaking capcity 16 KA complete all as specified and directed.
64Supply and fixing in repair of MCCB3 pole415 volts AC , 125 Amps breaking capcity 25 KA complete all as specified and directed.
65Supply and fixing in repair of MCCB3 pole415 volts AC , 200 Amps breaking capcity 25 KA complete all as specified and directed.
66Supply and fixing in repair of MCCB3 pole415 volts AC , 250 Amps breaking capcity 25 KA complete all as specified and directed.
67Supply and fixing in repair of MCBTP40 to 63 Amps 10 KA complete all as specified and directed.
68Supply and fixing in repair of MCBSP06 to 323 Amps 10 KA complete all as specified and directed.
69Dismantling and removing the electric motor,capcity 3 phase 415 Voltsfrom base frame, transporting to workshop checking of winding / leads for any loose connection, varnishing and baking in winding properly after dismantling and then re-assembling proerly transporting back to site re-installation, re-alignment and testing complete all as directed.
70(a) Capacity 30 HP to 75 HP
71(b) Capacity 10 HP to 20 HP
72(c) Capacity upto 7.5 HP
73Dismantling the unserviceable electric motor any type or of any capacity and transporting to reputed workshop, taking out old and burnt winding wire and rewinding with super enameled copper winding wire of existing gauge andsize with insulating materials, varnishing andbaking etc,re-fixing the same at site andre-alignment,testing and commissioning complete all as specified and directed.
74Taking out old and unserviceable PVC fins of cooling tower of anycapacity AC plant and replacing with new one includingsetting complete all as specified and directed.
75Supply and fixing in reapir fabricated micro filter upto 90 micron made out of GI channel frame overall size 55 cm x 55 cm x 5 cm including nylon micro filter and wire mesh covered front and back all as per sample given including taking down old micro filter complete all as specified and directed.
76All as per item No 57 above butoverall size 60 cms x 60 cms x 5 cm .
77All as per item No 57 above butoverall size 63 cms x 50 cms x 5 cm .
78All as per item No 57 above butoverall size 52 cms x 47 cms x 5 cm .
79All as per item No 57 above butoverall size 100 cms x 120 cms .
80Supply and fix in repairDOL starter suitable for 5HP motor capacity 9 to 14 Ampcomplete with over load relay , single phasing preventer under volt release in existing enclosure etc complete all as specified and directed.
81Supply and fix in repair DOL starter suitable for 10 HP motor capacity 14 to 23 Ampcomplete with over load relay , single phasing preventer under volt releasein existing enclosure etc. complete all as specified and directed.
82Nitrogen testingfor the following capacity of compressorsincluding condensing unit and gas piping completeas per the manufacturer instructiions and entire satisfaction of the Engineer in Charge. Note :-Nitrozen pressure should be held with out any dropin pressure inside the unit continue for 24 hours.
83(a) 02X30 TR capacity at OLD BMF AC plant
84(b) 03X48 TR capacity at EHU/ERS AC plant
85(c) 03X 20 TR capacity at EHU MIG AC plant
86(d) 02X37.7 TR capacity at BSF AC plant
87(e) 02X7.5 TR NAY (G) Store room AC Plant
88(f)04X60 TR capacity at Mig Simulator AC plant
89(g) 06X24 TR capacity at Mag Guard AC plant
90(h) 02X12.5 TR capacity at EHU NAY (G) AC plant
91Preparation of old painted surfaces by removing dust, rust etc and, applying two coats of synthetic enamel paint with spray gun of approved make and colour for cooling tower, condensing pipe line condenser water pumps including all pipe line valves etc. of 5 TR to 20 TR Capacity Plant.
92Preparation of old painted surfaces by removing dust, rust etc and, applying two coats of synthetic enamel paint with spray gun of approved make and colour for cooling tower, condensing pipe line condenser water pumps including all pipe line valves etc. of 24 TR to 60 TR Capacity Plant.
93Supply and fix CT fan (with hub and fan blade) of capacity 75 TR to 150 TRcooling tower all as specified and directed by Engr-in-Charge
94Supply and fix CT fan (with hub and fan blade) of capacity upto 60 TRcooling towerall as specified and directed by Engr-in-Charge
95Supply and fixing of union 40 mm of water tower all as specified.
96Supply and fixing of union 32/25 mmof cooli ng tower all as specified.
97Supply and fixing of gate valve 40 mmof cooling tower all as specified.
98Supply and fixing of gate valve 32/25 mm of cooling tower all as specified.
99S & F in repair chilled water sesor for AC Plants of various capacity
100S & F loading/unloading switch assembly for compressor of capacity upto 15 TR.
101S & F loading/unloading switch assembly for compressor of capacity from 20 TR upto 30 TR.
102S & F loading/unloading switch assembly for compressor of capacity from 45 TR upto 60 TR.
103S & F pressure gauge for neon gases 0 to 25 kg .
104S & F pressure gauge for freon gases 0 to 16 kg .
105S & F microprocessor for compressor of capacity from 20 TR to 37.7 TR
106S & F microprocessor for compressor of capacity from 45TR to 60 TR
107S & F cooling tower nozzles 1/4"" size
108S & F block bearing for air handling unit of any size
109Realignment of compressor and motor of anycapacity on existing foundation.
110S&F in repair pre-filter capsule suitable for accommodating five units of corrosion & scale inhibitor sealed refill of 51.0cm for cooling tower application.
111S&F in replacement of strip heater 2 KW capacityincluding making electrical connections with main supplycompleteall as specified and as directed.
112All as per item No 85.00 above but strip heater capacity 3 KW capacity.
113Evacuation of gas/ Refrigerantfrom the system into the empty cylinders before dismantling of old unserviceable compressorfromcondensing or chiller unit M & L for dismantlingUNSVcompressor , and Supply, installation, testing & commissioning of scroll compressor of capacty 12.5 TR , 3 Phase, 415 V , model No.SM185S4RC (Make- Danffoss) , self lubricating completeincluding HP and LPsensors with control wiring,connecting and rewiring with microprocessor based control panels andall as specified & directed by Engineer-in-Charge . Note:- The rate quoted by the contractorfor the above item shall be deemed inclusive of the following:- (i) Refrigerant storage containers. (ii) Refrigerant pumping system. (iii) Recharging of refrigerentrequired to top up into the system to achieve desiredsuction and discharge pressure (iv) Rewiring / reconnection of the system with Microprocessor based control panel from authorised manufacturers.
114S&F in replacement of oil pressure sensor suitablefor voltas 5H-60 compressor as per sample available at site complete all as specified and directed.
115S&F in replacement of High pressure sensor suitablefor voltas 5H-60 compressor as per sample available at site complete all as specified and directed.
116S&F in replacement of Low pressure sensor suitablefor voltas 5H-60 compressor as per sample available at site complete all as specified and directed by Engr-in-Charge
117S&F in replacement of unloading solenoid assembly suitablefor voltas 5H-60 compressor as per sample available at site complete all as specified and directed.
118S&F in replacement of magnetic coil for unlaoding solenoid suitablefor voltas 5H-60 compressor as per sample available at site complete all as specified and directed.
119S&F in replacement of extension pipe with closing valve 1/4"X1/4"as per sample available at site complete all as specified and directed.
120M&L for oil diffrential pressure control high pressure and low pressure switch, rewiring of the control and connecting to starter panel complete all as specified and directed.
121S&F in replacement of HDPE make up water tank of 1000 litre capacity with air vent, drain, overflow and make up connectionwith PVC High Pressure float valvecomplete all as specified and directed.
122M & L for taking out old worn out cladding and supply and rapping glass wool andaluminium cladding to cover the GI tubing 100/80/65 mm bore to avoid heat condution.
123S & F in repairs liquid line drier 5/8" x 5/8" all as directed
124All as per item No 97.00 above but of in suction side of size 1/2" all as directed
125S & F in repairs cooling tower fan blade assy of sixe 24 to 30" (MN 2 model of M/s Mihir Engineers) complete all as specified and directed.
126S & F in repairs water line strainer 2 1/2" dia size with GI flange including necessary joint arrangement complete at NDT Ejection Bay AC plants all as directed
127S & F in repairs condensor monoblock water pump set 3 HP 3 phase capacity with suitable head and discharge ammunator store including necessary PCC foundation work and electric/ water connection complete all as directed.
128Supply only Pressure Gauge 0 x 300psi (100mm) all as directed
129M & L Overhauling/ repair of all refrigertion line valve of any size, globe valves angle way valves including replacement of Teflon seat, "O" ring packing glands etc all as directed
130M & L for replacement of tarpaulim canvas cloth connecting the air outlet and main duct of AHU as per existing size and thickness inclusing provision of chain with Zip for taking Wet/ Dry Bulb reading, angle iron complete, including taking out unserviceable as directed
131M & L for side/ lower tray panels for coil section masde out of Mild steel plain sheet of thickness 1.60 mm, cut yo sixe, holes punched, including round headed screws, or rivets and fixed to steel framing as required and painting with two coat of synthetic enamel grey paint over a coat of red oxide primer for Air handling all as specified
132S & F in repairs Electronic New Micro processor suitable for 8.5 TR package type AC plant including electrical connection etc all as directed
133S & F in repairs Thermal over load relay 2.5 to 9 Amp complete all as specified and directed.
134S & F in repairs Pedestal Bearing Model : NTN F- of any size AHU blower shaft all as directed
135Dismantling carefully and removing of old U/S compressor"s sealed unit of 5.5Ton capacity from package type Air conditioner and supply anf fix new sealed unit of 5.5 Ton capacity complete with all standeard accessories as per existing AC plant complete all as specified and directed. Note:- Sealed unit shall be purchased from authorised dealers/agents
136Dismantling carefully and removing of old U/S compressor"s sealed unit of 8.5Ton capacity from package type Air conditioner and supply anf fix new sealed unit of 8.5 Ton capacity complete with all standeard accessoriesa as per exisitingAC plant complete all as specified and directed. Note:- Sealed unit shall be purchased from authorised dealers/agents
137Rewiring of all electrical controls inclsuing Micro- processor, electric contractor, supply and fix in replacement of auxiliay contractor for one of central AC plant package type AC plant of any capacity complete all as specified and directed.
138S & F fix in repairs fabricated micro filter upto 90 micron made of HDPE overall size 100 cm x 120 cm(as per sample) complete all as specified and directed.
139S & F in repiars of Thermostatic Expansion Valve assembly complete Model : MVE -7 suitable for gas F-22 of complete all as specified and directed.
140S & F in repairsThermostatic Expansion Valve assembly complete Model : MVE-5 siuitable for gas F-22 of complete all as specified and directed.
141Dismanting of damaged cooling coil of 5TR to 20 TR AC plantcapacity and repairing of coling coil to distributor and nrow paralleled 5/16 size and from distributor to expansion valve and room expansion value to compressor suction line with 11/8" size of coopwer pipe including following items :- (a) Expansion value 5 TR-02 Nos (b) Distributor -02Nos (c) Filter drier 5/8x5/8-02 Nos (d) Hand shut off value 5/8"-02Nos
142All as per item No 115 above but20 TR to 60 TR AC plant .
143S & F in repairs DOL starter MK-1 complete with over load relay, SPP under volt release etc complete all as specified and directed.
144S & F in reapairs DOL starter suitable for 5HP TO 10HP motor MK-1 complete with over load relay, single phasing preventer under volt release etc all as directed.
145Supply and fix Starter box suitable for 5.5 TR package type unit including suitable accessories like power contactor three phase, 415 volts, MCBs, connector single preventer over load reley, control wiring with arrangement of auto/mannual control ON/OFF switch and including sheet metal enclosure of 2 mm thick CRCA sheet of adequate size with powder coated for enclosing with necessary fixing arrangements in AC plant unit by providing nuts, bolts, washers etc complete all as specified and directed by Engr-in-charge.
146Supply and fix pipe MS ERW steel including all specialheavy duty duly welded with 16 mm thick MS flange and drilled for fixing 16 mm dia bolt & nuts washer including rubber gasket etc all as specified and directedof following sizes :-
147(a)100 mm dia
148(b)80 mm dia
149(c)50/63 mm dia
150(d)32/40 mm dia
151Charges for attending break down of AC plant of 5 TR to 20 TR capacity by only auth OEM rep / team for fault finding incl attending repairsas and when required such as No start condition of AC plant and repairing, starting the AC plant till smooth running and setting up the alighnment/required paramenters of all major parts such as fan belt, compressor, gas charge, cooling tower, power contactor, starter, MCCBs, Micro processor based control panel, pumps etc as required in ground/as ordered by EIC all as directed. Note:-The payment for the above shall be made to Contractors after submitting the original invoice only
152Ditto all as per item No 121 here in before but of AC plant capacity 20 TR to 60 TR.
Disclaimer :