Tender For Preventive Maint/Servicing Of Dg Sets And Providing Retrofit Emission Control Device Of Dg Set, Amf Panel And Replacement Of U/S Parts Under Ge (East) Agra, agra-Uttar Pradesh

Military Engineer Services-MES has published Tender For Preventive Maint/Servicing Of Dg Sets And Providing Retrofit Emission Control Device Of Dg Set, Amf Panel And Replacement Of U/S Parts Under Ge (East) Agra. Submission Date for this Tender is 01-07-2023. Diesel Generators Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38116330
Corrigendum : Tender For Preventive Maint/Servicing Of Dg Sets And Providing Retrofit Emission Control Device Of Dg Set, Amf Panel And Replacement Of U/S Parts Under Ge (East) Agra
Open Tender
Indian
Uttar Pradesh
agra
01-07-2023

Tender Details

Preventive Maint/Servicing Of Dg Sets And Providing Retrofit Emission Control Device Of Dg Set, Amf Panel And Replacement Of U/S Parts Under Ge (East) Agra

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Jun-2023 Revised BOQ and change tender documents BOQ 01-07-2023
2 05-Jul-2023 Date corrigendum and PS corrigendum Date 06-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work : Preventive maint/servicing of DG sets & providing Retrofit Emission Control Device of DG set, AMF panel and replacement of U/S parts under GE (East) Agra
Sl. No. Item Description
1Servicingandchecking of25 KVA to 30 KVADG Set including supply and replacement of fuel filter ( primary and secondary), supper by pass filter, separator fuel filter,oil filterof suitable size and checking of all safety devicesincluding opening, adjusting, tightening of tappet cover complete by torque wrinch by applying proper pressure, cleaning of fuel and oil tank and refitting to DG set including filling ofengine oil and coolant ,complete cleaning of DG set examining and rectification of engine RPM, monitoring of output voltage and maintaining/adjusting speed governor,refilling the radiator with water and coolant, etc complete all as specified and directed. Note : Engine oil, coolant and safety device shall be measured and paid separately under respective item of Sch "A".
2All as per item No 1.00 above for 40 KVA to 62.5 KVA DG set.
3All as per item No 1.00 above for 125 KVA to 160 KVA DG set.
4All as per item No 1.00 above for 320 KVA DG set.
5All as per item No 1.00 above for400 KVA to 500 KVA DG set.
6All as per item No 1.00 above for 750 KVA DG set.
7Supply only Engine oil15 W / 40 complete all as specified and directed.
8Supply only coolant for radiater of DG sets complete all as specified and directed.
9Supply and filling distilled water suitable for DG set lead acid batterycomplete all as specified and directed.
10Supply and fixing in replacement ofheavy duty batterybrass terminal with nuts & bolts for battery heavy duty complete all as specified and directed.
11Supply and fixing in replacement ofAir Filter element complete set as per existing type samples and replaced the same which is required at site complete ( as primary and secondary filters ) suitable for 25 KVA to 62.5 KVA DG set.
12Supply and fixing in replacement ofAir Filter element complete set as per existing type samples and replaced the same which is required at site complete ( as primary and secondary filters ) suitable for 125 KVA to160 KVA DG set.
13Supply and fixing in replacement ofAir Filter element complete set as per existing type samples and replaced the same which is required at site complete ( as primary and secondary filters ) suitable for320 KVA DG set.
14Supply and fixing in replacement ofAir Filter element complete set as per existing type samples and replaced the same which is required at site complete ( as primary and secondary filters ) suitable for 400 KVA to500 KVA DG set.
15Supply and fixing in replacement ofAir Filter element complete set as per existing type samples and replaced the same which is required at site complete ( as primary and secondary filters ) suitable for 750 KVA DG setDG set .
16M&L for disconnectingand taking down of self starter, 12 volts DCfor DG sets for repairing including replacement of bendex pinion,bush set,winding of armatureandwinding of field coil assembly etc and reassembling the same as original complete self starter and refixing in its original position including testing complete all as specified and directed.
17M&L for disconnectingand taking down of self starter, 24volts DC for DG setsfor repairing including replacement of bendex pinion,bush set,winding of armatureandwinding of field coil assembly etc and reassembling the same as original complete self starter and refixing in its original position including testing complete all as specified and directed.
18M&L for disconnecting, dismantling and overhauling of fuel injector pump of DG set capacity 25 KVA to 62.5 KVA and refixing properly to original position afterreplacement of Nozzle, F.I.P. Elements, Delivery valve, fuel pump gearandunserviceable parts etc.including overhauling, calibration and testing at admissible pressure properly complete all as specified and directed.
19M&L fordisconnecting, dismantling and overhauling of fuel injector pump of DG set capacity 125 KVA to160 KVA and refixing properly to original position afterreplacement of Nozzle, F.I.P. Elements, Delivery valve, fuel pump gearand unserviceable parts etc. including overhauling, calibration and testing at admissible pressure properly complete all as specified and directed.
20M&L for disconnecting, dismantling and overhauling of fuel injector pump of DG set capacity 320 KVA to500 KVAand refixing properly to original position afterreplacement of Nozzle, F.I.P. Elements, Delivery valve, fuel pump gearand unserviceable parts etc. including overhauling, calibration and testing at admissible pressure properly complete all as specified and directed.
21M&L for disconnecting, dismantling and repairing of alternator 12/24 volts DC for battery charging from DG set engine with replacement of carbon bushes-2, Cut-out, Carbon holder,Slip rings, Bearings-02, Rotor assembly, Stator assembly,connection plate etc, reassembling and refixing to DG set engine after necessary repair complete all as specified directed.
22M&L for dismantling of defective water pump assembly by disconnecting of hose pipe connections, fan felt and radiator connection.Supply and fixing of new water pump assembly suitable for DG set capacity of 25 KVA to62.5 KVA complete all as specified directed.
23M&L for dismantling of defective water pump assembly by disconnecting of hose pipe connections, fan felt and radiator connection.Supply and fixing of new water pump assembly suitable for DG set capacity of 125 KVA to160 KVA complete all as specified directed.
24M&L for dismantling of defective water pump assembly by disconnecting of hose pipe connections, fan felt and radiator connection.Supply and fixing of new water pump assembly suitable for DG set capacity of 320 KVA to500 KVA complete all as specified directed.
25M&L for replacement of AVR , voltage variation between +-5% of rated voltage i.e 415 Volts suitable for 40 KVA to62.5 KVA DG setcomplete all as specified and directed.
26M&L for replacement of AVR , voltage variation between +-5% of rated voltage i.e 415 Volts suitable for 125 KVA to160 KVA DG setcomplete all as specified and directed.
27S&F in repair fully automatic battery charger input 230V AC and out put 24V DC, 10 Amp,for 24 Volt battery complete all as specified and directed.
28S&F in repair fully automatic battery charger input 230V AC and out put 12V DC,6 Amp for 12Volt battery complete all as specified and directed.
29Taking down old repairable Radiator by opening nut/bolt from foundation and loading/unloading and transportation to local market. Dismantling, checking, testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process.Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator with loading/unloading and transportation charges for refixing to its old position with proper accuracy and correct situationfor Capacity from 40 KVA to 62.5 KVA DG setsincluding replacement of nut/bolt, hose pipe sets with clamps and testing complete.
30Taking down old repairable Radiator by opening nut/bolt from foundation and loading/unloading and transportation to local market. Dismantling, checking, testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process.Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator with loading/unloading and transportation charges for refixing to its old position with proper accuracy and correct situationfor Capacity from 125 KVA to 160 KVA DG setsincluding replacement of nut/bolt, hose pipe sets with clamps and testing complete.
31Taking down old repairable Radiator by opening nut/bolt from foundation and loading/unloading and transportation to local market. Dismantling, checking, testing for any defects and repairing as below : - Cleaning, washing the copper tubes and Top to bottom Copper Jal Frame of the radiator by acid process.Checking the leakage if any and repairing the same by doing the Soldering and Testing radiator with loading/unloading and transportation charges for refixing to its old position with proper accuracy and correct situationfor Capacity from 320 KVA to 500 KVA DG setsincluding replacement of nut/bolt, hose pipe sets with clamps and testing complete.
32S&F in replacement of Valve solenoid (Shut down valve) sutablefor DG sets complete all as specified and directed.
33S&F in replacement of Thermostat sutableforDG sets complete all as specified and directed.
34S&F in replacement Hose flexible sutableforDG sets complete all as specified and directed.
35S&F in replacement Switch temperature (water safety) sutableforDG sets complete all as specified and directed.
36S&F in replacement Switch pressure(Oil safety) sutableforDG sets complete all as specified and directed.
37S&F in replacementV Belt/Fan belt sutableforDG sets complete all as specified and directed.
38Supply and fixing in repair battery lead, PVC copper wire multistandard 25 Sqmm - 2m long including soldering both endwith lead terminal for live & earth complete all as specified and directed.
39Supply & fixingin replacement of lead acid battery 12 Volts150 AHincluding filling of electrolyte, initial charging of battery etc incl making connection with self starter complete all as specified directed.
40Supply & fixing in replacement of lead acid battery 12 Volts180 AHincluding filling of electrolyte, initial charging of battery etc incl making connection with self starter complete all as specified directed.
41Supply & fixing in replacement ofPULSE ULTRA LITEBattery 12 Volts 160 AH ,maintenance free pure lead tin and valve regulated acid techonolgy,light weight,high starting current capability including initial charging of battery etc incl making connection with self starter complete all as specified directed. Make : CUMMINS PULSE ULTRA LITE MODEL NO-AX1012845 or or equivalent in other makes as approved by GE.
42M&L fordisconnecting, dismantling and repairingof turbo charger assembly for25 KVA to62.5 KVADG set including replacement of Kit Turbo Repair , Shaft, Sleeve Turbocharger, Support Turbocharger Sealetcincludingtestingand refixing to its original position properly complete all as specified and directed .
43M&L fordisconnecting, dismantling and repairingof turbo charger assembly for125 KVA to160 KVADG set including replacement of Kit Turbo Repair , Shaft, Sleeve Turbocharger, Support Turbocharger Sealetcincludingtestingand refixing to its original position properly complete all as specified and directed .
44M&L fordisconnecting, dismantling and repairingof turbo charger assembly for 320 KVA to500 KVADG set including replacement of Kit Turbo Repair , Shaft, Sleeve Turbocharger, Support Turbocharger Sealetcincludingtestingand refixing to its original position properly complete all as specified and directed .
45M & L for taking out old Flywheel ring from DG set and replacement of new flywheel ring with proper setting and alignment for25 KVA to 62.5 KVA DG Set complete all as specified and directed.
46M & L for taking out old Flywheel ring from DG set and replacement of new flywheel ring with proper setting and alignment for125 KVA to 160 KVA DG Set complete all as specified and directed.
47M & L for taking out old Flywheel ring from DG set and replacement of new flywheel ring with proper setting and alignment for320 KVA to 500 KVA DG Set complete all as specified and directed.
48M & L for repairing of automatic battery charger of 24 Volt / 12 Volt including rewinding of transformer unit and replacement ofdiode plates, rectifier plates,auto cut mosfet circuit , fuses etc. and testing all as specifed and directed.
49Supply & fixing new in replacement of MCCB, 100 Amp, 4 pole, 25 KA , 415 Voltincluding taking out existing connections, cable lugs etc all as specified and directed.
50Supply & fixing new in replacement of MCCB, 125 Amp, 4 pole, 25 KA , 415 Voltincluding taking out existing connections, cable lugs etc all as specified and directed.
51Supply & fixing new in replacement of MCCB, 200 Amp, 4 pole, 50 KA , 415 Voltincluding taking out existing connections, cable lugs etc all as specified and directed.
52Supply & fixing new in replacement of MCCB, 400 Amp, 4 pole, 50 KA , 415 Voltincluding taking out existing connections, cable lugs etc all as specified and directed.
53Checking of AMF panel / DG set for detecting any kind of fault in AMF panel/DG set and attending the fault immediately at any time round the clock and carry out certain repairrequired at per site requirement and checking of AMF panel andDG set for power suply from DG set through AMF panel and replacing of worn out parts of AMF panel/DG setbyexpert engineer complete all as directed.Notes :- (a) Unit rate of this item includes "detecting of any kind of fault in AMF panel/DG set" only and cost ofreplacement of worn out parts of AMF panel/DG set shall be measured and paid separately under items of schedule "A".
54Supply & fixing new in replacement of OFF-Load Changeover switch (Side Handle) of 200 Amps, 4 Pole, 415 V, 50 Hz..
55Supply & fixing in replacement of Contactor- 4 Pole, 63 AMPSforDG Set AMF panel withreplacement of lugs and checking of all connections etc. Make:- L &T ( CS97014 ) / SCHNEIDER
56Supply & fixing in replacement of Contactor- 3 Pole, 200 AMPSforDG Set AMF panel withreplacement of lugs and checking of all connections etc.Make:- L &T ( CS94140 )/ SCHNEIDER
57Supply & fixingin replacement of Digital Frequency meter, 96 Sqmm.
58Supply & fixingin replacement of DigitalVoltmeter, 96 Sqmm.
59Supply & fixingin replacement of Digital Ammeter, 96 Sqmm.
60Supply & fixingin replacement of AMF Relay Box for Auto/ Manual functionsuitable for all capacities of DG set complete all as specified and directed.
61Supply & fixingin replacement of MAINS / GENERATOR Voltage Monitor Box for Auto/ Manual functionfor 63 KVAto 200 KVA DG set.
62M & L for replacement of Magnetic Pickup suitable for 25 KVA to62.5 KVA DG set complete all as specified and directed.
63M & L for replacement of Magnetic Pickup suitable for 125 KVA to320 KVA DG set complete all as specified and directed.
64M & L for replacement of Magnetic Pickup suitable for 400 to 500 KVA DG set complete all as specified and directed.
65Supply & fixing new in replacement of SOLENOID STOPPER -12 VOLT DC / 24 VOLT DC suitable for25 KVAto160 KVADG set complete all as specified and directed.
66Supply & fixing in replacement of Voltage monitoring relay 3 phase for AMF PANEL ofall capacities of DG set complete all as specified and directed.
67M & L for repairing of canopy doors complete with renewal of following itmes including denting and necessary welding of doors complete all as specified and directed.
68Stain less SteelDoor lock.
69Stain less Steeldoor handle
70Stain less SteelHinges
71Supply & fixing new in replacement of Three Phase Multifunction Digital meter suitable for all capacities of DG set complete all as specified and directed.
72M&L, all arrangement for shifting ofAny Canopy DG set from Agra Cantt any Area andinstalled the DG setwith PCC Foundation duly providing of all electrical connections in the existing LT Panel complete all as directed by EIC.
73M & L for replacement of existingUNSV sign board withsize of4 X 3 feet of steel sheetboard of 2 mm size heavy dutyincluding writing alphabatic letters computerised with retro refelctive sheets to be madeas all directedof size150mm fonts andfixed with stainless steel pipe heavy dutyof size 40 to 50 mm diaand to be fixed outside the installations duly burried in ground along with required PCC and top of the sign board should be 2.5 mtr high from G.L.complete all as specified and directed.
74M & L for painting of DG set upto 400 KVA , panels, diesel tank, silencer including canopy and painting complete with two coats with super enamel paint and afterone coat of primer for any type ofDG Set.
75Supply of first aid box kit having all necessary items atDG SET installations as specified and directed by Engr-In-Charge.
76Supply installation and testing of retrofit emission control device to reduce the emission limit as per CPCB II norms including all necessary connections required for its installation.Note-The device should have approval of CPCB recgnised lab.