Tender For Repairs/Maint To Lt External Electrification At Zones I, Ii And Iii Of Likabali, Repairs And Maint Of Security/ Perimeter Light/ High Mast Light/ Solar Lights/ Garden Lights And Connected Items At Likabali And Repairs/ Maint To Exter -Nal, likabali-Assam

Military Engineer Services-MES has published Tender For Repairs/Maint To Lt External Electrification At Zones I, Ii And Iii Of Likabali, Repairs And Maint Of Security/ Perimeter Light/ High Mast Light/ Solar Lights/ Garden Lights And Connected Items At Likabali And Repairs/ Maint To Exter -Nal. Submission Date for this Tender is 26-06-2023. Electrification Work Tenders in likabali Assam. Bidders can get complete Tender details and download the document.




Tender Notice

38115715
Corrigendum : Tender For Repairs/Maint To Lt External Electrification At Zones I, Ii And Iii Of Likabali, Repairs And Maint Of Security/ Perimeter Light/ High Mast Light/ Solar Lights/ Garden Lights And Connected Items At Likabali And Repairs/ Maint To Exter -Nal
Open Tender
Indian
Assam
likabali
26-06-2023

Tender Details

Repairs/Maint To Lt External Electrification At Zones I, Ii And Iii Of Likabali, Repairs And Maint Of Security/ Perimeter Light/ High Mast Light/ Solar Lights/ Garden Lights And Connected Items At Likabali And Repairs/ Maint To Exter -Nal Electric An

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 86600.0 /-
Tender Value
INR 43.30 Lakhs /-

BOQ Items

NAME OF WORK : REPAIRS/MAINT TO LT EXTERNAL ELECTRIFICATION AT ZONES I, II & III OF LIKABALI, REPAIRS & MAINT OF SECURITY/ PERIMETER LIGHT/ HIGH MAST LIGHT/ SOLAR LIGHTS/ GARDEN LIGHTS & CONNECTED ITEMS AT LIKABALI AND REPAIRS/ MAINT TO EXTERNAL ELECTRIC & WATER SUPPLY AT TECH AREA OF LIKABALI MIL STN UNDER GE 872 EWS
Sl. No. Item Description
1EARTH WORKS
2Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Water Mains, Cables, Electric Poles, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
3Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Metre for Electric Poles, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
4Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in layers not exc. 25 Cm, Providing Heaps along the Route of the Water Mains, Cable Lines, etc. with surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
5Removing Excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.
6Drilling/Making Hole (Horizontally) under Roads/ Hardstanding, etc. by any means suitable for Passing GI Tubing 40mm to 80mm bore (dia), complete all as specified and as directed.
7M&L Cutting on Existing Road not exc. 1.00 Metre in Depth and not exc. 0.50 Metre in Width including Making Good the Same with Cement Concrete 1:3:6 (40mm graded stone aggregates) not exc. 200mm thick on Top Layer after necessary Returning, Filling in, Well Ramming and Levelling in Layers to match the Existing Surface Levels, complete all as specified and as directed. NOTE : Cement Concrete 1:3:6 (40mm graded stone aggregates) not exc. 200mm thick will be Measured & Paid separtely under appropriate Item.
8REPAIRS & MAINT TO LT EXTERNAL ELECTRIFICATIONS
9Dismantling Unserviceable LT Steel Tubular Pole of any description and any Size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed. NOTE : Unserviceable Pole will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earthwork, Demolition Cement Concrete, etc. will not be Measured and Paid separately.
10Dismantling Cross Arms, Mild Steel Channel, Angle Section, Flat Iron, Mild Steel Rod, etc., complete all as specified and as directed.
11Taking down Unserviceable Insulator of any Size and any description from LT Electric Poles or from any Situations, complete all as specified and as directed.
12Taking down ACSR Conductor of any Size including Line Spacers of OH Electric Lines from LT Electric Poles, complete all as specified and as directed.
13Taking down Unserviceable/ Rusted GI Earth Wire, Cradles Guards of any Size from LT Electric Poles of any Size and capacity, complete all as specified and as directed.
14Dismantling Stay Assembly complete of any description, complete all as specified and as directed. NOTE : Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earth Works, Demolition of Cement Concrete, etc. will not be Measured & Paid separately.
15M&L Cement Concrete 1:4:8 (40mm graded stone aggregates) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed.
16M&L Cement Concrete 1:3:6 (40mm graded stone aggregates) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed.
17M&L Cement Concrete 1:2:4 (20mm graded stone aggregates) in Copping of Electric Poles, etc., Weathering slightly rounded or Chamfered angle and throating, finishing all Exposed Faces of Concrete including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed.
18M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One coat of Red Oxide Zinc Chrome Primer, providing 3 No. Band/ Strap with Paint Black/ Yellow Colour 300mm apart from Plinth Block and numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed. NOTE : Necessary Earth Work & PCC will be Measured and Paid separately under relevent Items.
19M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or Size as indicated or directed and applying Two Coats of Aluminium Paint over a Coat of Aluminium Oxide Primer after preparation of Surfaces, complete all as specified and as directed.
20S&F Insulator Pin type, 100mm height, 65mm dia for 1100 Volt grade, Porcelain, Vitreous, white, brown or green including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut, complete all as specified and as directed.
21S&F Insulator Shackle type, Porcelain, Vitreious, white brown or green of Size 100mm High & 115mm dia including Galvanised Mild Steel Straps of Section 31x5.0mm, 14mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 1100 Volt grade, complete all as specified and as directed.
22S&F Insulator Loop type, Small in Size, Vitreous Porcelain, white, borwn or green with Overall Dimensions 65x90mm, Clearance of Hole 16mm 1100 Volt grade, complete all as specified and as directed.
23M&L ACSR Conductor of any Size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed. NOTE : Sizes of Conductor will be as per Site requirement/ as directed.
24M&L Restretching, Tightening & Fixing of ACSR Conductor of any Size on LT Electric Poles including necessary Aluminium Binding Wire including Refixing of Connectors, PVC Sleeves for Jumper, etc. complete all as specified and as directed. NOTE : Each Length of ACSR Conductor will be measured for Payment.
25M&L Jumper made out of ACSR Conductor of suitable Size and binding with and including Aluminium Binding Wire properly on the existing LT OH Line including Taking down Unserviceable Jumper, complete all as specified and as directed.
26S&F PVC Fibre Separator for LT Line 1100 Volt Over Head Conductor 3-4 Wire System for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed.
27S&F PVC Fibre Separator for LT Line 1100 Volt Over Head Conductor 5-6 Wire System for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed.
28M&L Galvanised Iron Wire 4.0mm dia (8 SWG) as Continuous Earth Wire, Guards and Cradles (hexagonal/rectangular), etc. and binding with and including GI Binding Wire 1.6mm dia, complete all as specified and as directed.
29M&L Stay Assembly complete with all Accessories including earth work such as Mild Steel Galvanised Flat Iron Stay Clamp, Galvanised Stay Wire 7/4.0mm stranded, One Insulator Loop type Porcelain Vitreous (white, brown or green) Overall Dimensions 90x140mm and Clearance of Hole 25.5mm, Stay Grips, Mild Steel Galvanised Stay Bow, Thimbles Galvanised steel 14mm dia & 400mm long, 20mm dia Mild Steel Galvanised Stay Rod 1900mm long and Mild Steel Galvanised Stay Plate of Size 300x300x6.0mm all as shown in Electrical Plate No. 1 of MES Schedule Part-I including necessary Earth Works (as per Site requirment), complete all as specified and as directed. NOTE : Cost of Labour for necessary Earthworks will deemed to be included in the Quoted Unit Rate.
30S&F Danger Notice Plate of Size 25x20 Cm for LT, made of 1.6 mm thick Mild Steel Sheet, Vitreous Enamelled White, Letters, Figures and Conventional Skull & Bones in Signal Red Colour and fixed with Mild Steel Vlamps, Bolts & Nuts of appoved Size including Taking down Unserviceable Danger Notice Plate, complete all as specified and as directed.
31REPAIRS & MAINT TO STREET LIGHTS
32M&L Taking down Street/Perimeter Light Fitting of any type and any capacity from any Height after Disconnecting, Opening Cover and Checking of Light Fitting, Repairing as required, Re-fixing the Light Fitting after repaired in Original Position and Providing Connections including Replacing Defective/ Unserviceable Spares/ Parts, complete all as specified and as directed. NOTE :- (a)Cost of Minor Items/Parts/Spares such as Wiring, Mild Steel Bolts, Nuts & Washers, etc. will deemed to be included in the Quoted Unit Rate. (b)New Parts/Spares, Driver, etc. (Quantites are Provisional) will be Measured & Paid separately under respective Items as "Supply only".
33Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 30/35 Watt, complete all as specified and as directed.
34Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 45 Watt, complete all as specified and as directed.
35Supply only Driver (as approved) suitable for LED Street Light Fitting 60 Watt, complete all as specified and as directed.
36M&L Lowering down High Mast Lights, Repairing High Mast Light by apply Greasing, Oiling, etc., Repairing as required, Re-hoisting High Mast Lights after Repaired including Replacing Defective/ Unserviceable Spares/ Parts, complete all as specified and as directed. NOTE :- (a)Cost of Minor Items/Parts/Spares such as Wiring, Mild Steel Bolts, Nuts & Washers, Greases, etc. will deemed to be included in the Quoted Unit Rate. (b)New Parts/Spares, Driver, etc. (Quantites are Provisional) will be Measured & Paid separately under respective Items as "Supply only".
37Supply only Driver (as approved) suitable for LED Flood Light Fitting 120 Watt, complete all as specified and as directed.
38Supply only LED Flood Light 1x120 Watt (as approved), complete all as specified and as directed.
39M&L Taking down Solar Light Fitting of any type and any capacity from any Height, Replacing Defective/ Unserviceable Spares/ Parts, Applying Mineral Jelly to the Battery Terminal(s), Tightening of All Connections, Cleaning of Solar Panel throughly, Filling Distilled Water to Solar Light Batteries, Re-fixing the Solar Light Fitting in Original Position, complete all as specified and as directed. NOTE :- (a)Cost of Minor Items/Parts/Spares such as Wiring, Mild Steel Bolts, Nuts & Washers, Greases, etc. will deemed to be included in the Quoted Unit Rate. (b)New Parts/Spares, Battery, Battery Terminals, Distilled Water, etc. (Quantites are Provisional) will be Measured & Paid separately under respective Items as "Supply only".
40Supply only Solar Battery 12 Volt, 75 AH, Dry Gel (as approved) suitable for 3 Days Backup capacity, complete all as specified and as directed.
41Supply only Tinned/ Copper Battery Terminals (as approved), complete all as specified and as directed.
42Supply only Distilled Water suitable for Solar Light Batteries, complete all as specified and as directed.
43S&F LED Street Light Fitting 35 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.
44S&F LED Street Light Fitting 45 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.
45S&F LED Street Light Fitting 60 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.
46S&F BAMBOO Light Fitting 8 Watt, 1000mm in Height (as approved) New Generation Environmental Friendly, Energy Saving, Long Life, Aesthetically Designed, Aluminium Landscape Luminaire for Diffused Lighting with High Power LED as Light Source, IP-65 protected, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.
47S&F LED Post Top Light Fitting 20 Watt (as approved) New Generation, Energy Saving, Environmental Friendly, Long Life, Aesthetically Designed with Symmetrical Light Distribution, Spun Aluminium Landscape Luminaire with High Power LEDs as Light Source, IP-65 protected, suitable for Pole 50/76mm dia, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.
48S&F LED Post Top Light Fitting 40 Watt (as approved) New Generation, Energy Saving, Environmental Friendly, Long Life, Aesthetically Designed with Symmetrical Light Distribution, Spun Aluminium Landscape Luminaire with High Power LEDs as Light Source, IP-65 protected, suitable for Pole 76mm dia, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.
49M&L Restretching, Tightening & Fixing of ACSR Conductor of any Size on LT Electric Poles including necessary Aluminium Binding Wire, Connectors, PVC Sleeves for Jumper, etc. complete all as specified and as directed. NOTE : One Length will be measured for complete Span comprising of any numbers of ACSR Conductor(s) & GI Wire(s).
50M&L Trimming/Cutting of Tree Branches of any girth/Size and Clearing of LT OH Lines (any Nos. of ACSR Conductors, Earth Wire, etc.) upto 3.0 Metre distance, Removing Tree Branches from the Sites, complete all as specified and as directed.
51M&L Painting LT Pre-stressed Concrete Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with Two coats of Cement Based Paints and Numbering of Code in letter Size not less then 50mm in Black Paints and Painting of Pole with Strips 300mm high (5 Nos.) around the Pole with Two different Colour SyntheticEnamelled Paint for Pole 7.5 Metre height above Ground Level, complete all as specified and as directed.
52M&L Painting LT Steel Tubular Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with One coat of Aluminium Paints and Numbering of Code in letter Size not less then 50mm in Black Paints and Painting of Pole with Strips 300mm high (5 Nos.) around the Pole with Two different Colour SyntheticEnamelled Paint for Pole 7.5 Metre height above Ground Level, complete all as specified and as directed.
53S&F PVC insulated Aluminium Wire 1.5 Sqmm, 3 Core for Providing Connection from Overhead Line to Street Light Fitting including Taking down Unserviceable Wire of any description, complete all as specified and as directed.
54REPAIRS & MAINT TO LT UG CABLE WORKS
55Disconnecting & Taking down/out Unserviceable LT Cable of any Size and any description from Trenches, Floors, Walls, GI Pipes, etc. incuding Serviceable (if any) Cables, Cable Joints, Bricks/Cable Protection Cover, etc. keep in Safe Custody for re-use, complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid under appropriate Items.
56M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 10 Sqmm, 2 Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GIPipe, etc. will be Measured and Paid separately under relevent Items.
57M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 16 Sqmm, 4 Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GIPipe, etc. will be Measured and Paid separately under relevent Items.
58M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 25 Sqmm, 4 Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GIPipe, etc. will be Measured and Paid separately under relevent Items.
59M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 35 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GIPipe, etc. will be Measured and Paid separately under relevent Items.
60M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 50 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GIPipe, etc. will be Measured and Paid separately under relevent Items.
61M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 70 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GIPipe, etc. will be Measured and Paid separately under relevent Items.
62M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 95 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GIPipe, etc. will be Measured and Paid separately under relevent Items.
63M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 120 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GIPipe, etc. will be Measured and Paid separately under relevent Items.
64M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 150 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GIPipe, etc. will be Measured and Paid separately under relevent Items.
65M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 185 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GIPipe, etc. will be Measured and Paid separately under relevent Items.
66M&L Taking down Unserviceable LT Cable, Cross-sectional Area upto 25 Sqmm, 3½/4.0 Core of any description, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as Ordered, Relaying/ Re-fixing the Cable after Rectification, complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GIPipe, etc. will be Measured and Paid separately under relevent Items.
67M&L Taking down Unserviceable LT Cable, Cross-sectional Area exc. 25 Sqmm and not exc. 120 Sqmm, 3½/4.0 Core of any description, 1100 Volt grade from any Situ-ation, finding out Cable Fault and Rectification of Cable Fault as Ordered, Relaying/ Re-fixing the Cable after Rectification, complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GIPipe, etc. will be Measured and Paid separately under relevent Items.
68M&L Taking down Unserviceable LT Cable, Cross-sectional Area exc. 120 Sqmm, 3½/4.0 Core of any description, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as Ordered, Relaying/ Re-fixing the Cable after Rectification, complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GIPipe, etc. will be Measured and Paid separately under relevent Items.
69M&L Cable Jointing Kit, Straight Through, Heat Shrink type complete with Jointing Materials and Accessories suitable for 1100 Volt Grade XLPE Armoured Aluminium Conductor Cable, Cross-sectional Area 25 Sqmm to 50 Sqmm, 3½/4.0 Core and Testing, complete all as specified and as directed.
70M&L Cable Jointing Kit, Straight Through, Heat Shrink type complete with Jointing Materials and Accessories suitable for 1100 Volt Grade XLPE Armoured Aluminium Conductor Cable, Cross-sectional Area 70 Sqmm to 95 Sqmm, 3½/4.0 Core and Testing, complete all as specified and as directed.
71M&L Cable Jointing Kit, Straight Through, Heat Shrink type complete with Jointing Materials and Accessories suitable for 1100 Volt Grade XLPE Armoured Aluminium Conductor Cable, Cross-sectional Area 120 Sqmm to 185 Sqmm, 3½/4.0 Core and Testing, complete all as specified and as directed.
72M&L Sand Cushioning (Dry) in Trenches/Ducts for protection of UG Cables (below, above & around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
73Supply & laying Sub-class ‘B’ Bricks of Size 230x115x75 mm, Kiln burnt, for Covering to UG Cable as Protection, laid Flat, Transversally Width Equal to the Length of the Cable, complete all as specified and as directed.
74Supply & Laying Unreinforced Pre-cast Concrete Cable Cover of Size 250x150x40mm thick, Class LV, Type 1, Flat, Concrete grade M-20 minimum, complete all as specified and as directed.
75M&L Galvanised Steel Tubing Pipe 40mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable Size Mild Steel Flat Iron 40x4.0mm Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
76M&L Galvanised Steel Tubing Pipe 50mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable Size Mild Steel Flat Iron 40x4.0mm Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
77M&L Galvanised Steel Tubing Pipe 80mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable Size Mild Steel Flat Iron 40x4.0mm Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
78M&L UG Cable Route Indicator, Comprising of Mild Steel Round Bar 20mm dia as Leg 600mm long and welded to Mild Steel Plate 5.0mm thick of 100mm dia for writing "1.1 KV LTUG CABLE" with ARROW mark, fixing with and including Cement Concrete 1:2:4 (20mm graded Stone aggregates) Block of Size 300x300x 400mm, grouting in Natural Ground along the Cable Route including necessary Earth Works (as per Site requirment), complete all as specified and as directed. NOTE : Cost of Labour for necessary Earthworks will deemed to be included in the Quoted Unit Rate.
79REPAIRS & MAINT TO LT PANEL BOARDS & EARTHING
80S&F Air Circuit Breaker 630 Amp, 4 Pole, 415 Volt, 50 Hz, Front Operated with Thermal Magnetic Realease (Manual Drawout type) and fixing to existing Panel Board including Taking down/ out Unserviceable ACB of any description, complete all as specified and as directed.
81S&F Change Over Switch 63 Amp rating, On Load, 4 Pole, 415 Volt (Side Handle Operated) in Sheet Metal Enclouser and Connecting up including Taking down/ out Unserviceable Change Over Switch, complete all as specified and as directed.
82S&F Change Over Switch (Front Operated), On Load, Open Execution, 100 Amp rating, 4 Pole, 415 Volt and Connecting up including Taking down/out Unserviceable Change Over Switch, complete all as specified and as directed.
83S&F Change Over Switch 100 Amp rating, On Load, 4 Pole, 415 Volt (Side Handle Operated) in Sheet Metal Enclouser and Connecting up including Taking down/ out Unserviceable Change Over Switch, complete all as specified and as directed.
84S&F Change Over Switch 200 Amp rating, On Load, 4 Pole, 415 Volt (Side Handle Operated) in Sheet Metal Enclouser and Connecting up including Taking down/ out Unserviceable Change Over Switch, complete all as specified and as directed.
85S&F MCCB 63 Amp rating, 4 Pole, 16 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
86S&F MCCB 100 Amp rating, 4 Pole, 16 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
87S&F MCCB 125 Amp rating, 4 Pole, 16 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
88S&F MCCB 160 Amp rating, 4 Pole, 36 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
89S&F MCCB 200 Amp rating, 4 Pole, 36 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
90S&F MCCB 250 Amp rating, 4 Pole, 36 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
91S&F MCCB 400 Amp rating, 4 Pole, 36 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/ out Unserviceable MCCB, complete all as specified and as directed.
92M&L Repairing Broken Door, Locking Arrangements, Hinges, etc. of LT Panel/ Feeder Pillar, Indoor/ Outdoor type of any Size including Locking Arrangements, Hinges, etc. (as ordered/ required at Site of Work) and necessary welding, drilling as required, complete all as specified and as directed. NOTE : Cost of Minor Items viz Locking Arrangements, Hinges, Mild Steel Bolts, Nuts & Washers, Greases, etc. will deemed to be included in the Quoted Unit Rate.
93M&L Cleaning, Scraping of Exposed Surfaces of LT Panel/ Feeder Pillar /Pole Box, Indoor/ Outdoor Type and applying One coat of Synthetic Enamel Paint (Paint & Shade as approved) with Spray Painting Machine including Writing MES No. and Machine No. with Black Paint, Letters 50mm High and 15mm Wide, complete all as specified and as directed.
94S&F Synthetic Insulation Mat of Size 2000x1000x2.5mm thick (as approved), ISI marked and suitable for 1100 Volts Grade including Taking out Unserviceable Insulation Mat of any description, complete all as specified and as directed.
95Supply, Installation & Commissioning LT Feeder Pillar Box, Factory Made (CPRI Tested Manufacturer), made out of 3.15mm thick CRCA Sheet with Angle Iron Frame 50x50x6.0mm, Outdoor type, Double Doors, Front & Rear Opening with Locking Arrangements, suitable for 415 Volt, 3 Phase, 4-Wire System, 50 Hz Supply having 4 No. Copper Bus-bars 200 Amp rated, installed on Porcelain/ Epoxy Insulator, Dust Proof and Vermin Proof (IP-54), Feeder Pillar Box Painted with Two Coats of Synethetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer and Fixing with Mild Steel Bolts, Nuts, Washers, etc. on Cement Concrete 1:2:4 (20mm graded Stone aggregates) Platform (minimum 600mm in Height from Natural Ground Level) and grouting Mild Steel Angle Iron Legs in Floor, Providing all Electric Connections and Testing, Comprising with and including following Accessories including Taking down/ out Unserviceable Feeder Pillar Box of any description, complete all as specified and as directed :- INCOMMER :- (a) MCCB 250 Amp, 4 Pole, 36 kA, 415 Volt-01 No. OUT-GOINGS :- (b) MCCB 160 Amp, 3 Pole, 36 kA, 415 Volt-01 No. (c) MCCB 100 Amp, 3 Pole, 16 kA, 415 Volt-02 No. (d) Digital Ammeter 0-300 Amp with suitable Size CT"s and -01 No. Selector Switch (e) Digital Volt Meter 0-500 Volt with Selector Switch -01 No. (f) Indicating Lamp LED type in Incomming Phase -02 Set (g) Internal Wiring with PVC insulated Copper Conductor Multi-stranded Cable 1100 Volt grade IS-694 marked of appropriate gauge including Copper Lugs (h) Connection from MCCB to Bus-bars with Solid Copper Conductor.
96Supply, Installation & Commissioning LT Feeder Pillar Box, Factory Made (CPRI Tested Manufacturer), made out of 3.15mm thick CRCA Sheet with Angle Iron Frame 50x50x6.0mm, Outdoor type, Double Doors, Front & Rear Opening with Locking Arrangements, suitable for 415 Volt, 3 Phase, 4-Wire System, 50 Hz Supply having 4 No. Copper Bus-bars 200 Amp rated, installed on Porcelain/ Epoxy Insulator, Dust Proof and Vermin Proof (IP-54), Feeder Pillar Box Painted with Two Coats of Synethetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer and Fixing with Mild Steel Bolts, Nuts, Washers, etc. on Cement Concrete 1:2:4 (20mm graded Stone aggregates) Platform (minimum 600mm in Height from Natural Ground Level) and grouting Mild Steel Angle Iron Legs in Floor, Providing all Electric Connections and Testing, Comprising with and including following Accessories including Taking down/ out Unserviceable Feeder Pillar Box of any description, complete all as specified and as directed :- INCOMMER :- (a) MCCB 160 Amp, 3 Pole, 36 kA, 415 Volt -01 No. OUT-GOINGS :- (b) MCCB 63 Amp, 3 Pole, 16 kA, 415 Volt -01 No. (c) MCB 6 Amp, Single Pole, 10 kA -02 No. (d) Digital Ammeter 0-200 Amp with suitable Size CT"s and -01 No. Selector Switch (e) Digital Volt Meter 0-500 Volt with Selector Switch-01 No. (f) Indicating Lamp LED type in Incomming Phase-02 Set (g) Internal Wiring with PVC insulated Copper Conductor Multi-stranded Cable 1100 Volt grade IS-694 marked of appropriate gauge including Copper Lugs (h) Connection from MCCB to Bus-bars with Solid Copper Conductor.
97Supply, Installation & Commissioning LT Feeder Pillar Box, Factory Made (CPRI Tested Manufacturer), made out of 3.15mm thick CRCA Sheet with Angle Iron Frame 50x50x6.0mm, Outdoor type, Double Doors, Front & Rear Opening with Locking Arrangements, suitable for 415 Volt, 3 Phase, 4-Wire System, 50 Hz Supply having 4 No. Copper Bus-bars 200 Amp rated, installed on Porcelain/ Epoxy Insulator, Dust Proof and Vermin Proof (IP-54), Feeder Pillar Box Painted with Two Coats of Synethetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer and Fixing with Mild Steel Bolts, Nuts, Washers, etc. on Cement Concrete 1:2:4 (20mm graded Stone aggregates) Platform (minimum 600mm in Height from Natural Ground Level) and grouting Mild Steel Angle Iron Legs in Floor, Providing all Electric Connections and Testing, Comprising with and including following Accessories including Taking down/ out Unserviceable Feeder Pillar Box of any description, complete all as specified and as directed :- INCOMMER :- (a) MCCB 125 Amp, 3 Pole, 16 kA, 415 Volt-01 No. OUT-GOINGS :- (b) MCCB 100 Amp, 3 Pole, 16 kA, 415 Volt-02 No. (c) On Load Change Over 125 Amp -01 No. (d) Digital Ammeter 0-200 Amp with suitable Size CT"s and -01 No. Selector Switch (e) Digital Volt Meter 0-500 Volt with Selector Switch -01 No. (f) Indicating Lamp LED type in Incomming Phase -02 Set (g) Internal Wiring with PVC insulated Copper Conductor Multi-stranded Cable 1100 Volt grade IS-694 marked of appropriate gauge including Copper Lugs (h) Connection from MCCB to Bus-bars with Solid Copper Conductor.
98Supply, Installation & Commissioning LT Feeder Pillar Box, Factory Made (CPRI Tested Manufacturer), made out of 3.15mm thick CRCA Sheet with Angle Iron Frame 50x50x6.0mm, Outdoor type, Double Doors, Front & Rear Opening with Locking Arrangements, suitable for 415 Volt, 3 Phase, 4-Wire System, 50 Hz Supply having 4 No. Copper Bus-bars 200 Amp rated, installed on Porcelain/ Epoxy Insulator, Dust Proof and Vermin Proof (IP-54), Feeder Pillar Box Painted with Two Coats of Synethetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer and Fixing with Mild Steel Bolts, Nuts, Washers, etc. on Cement Concrete 1:2:4 (20mm graded Stone aggregates) Platform (minimum 600mm in Height from Natural Ground Level) and grouting Mild Steel Angle Iron Legs in Floor, Providing all Electric Connections and Testing, Comprising with and including following Accessories including Taking down/ out Unserviceable Feeder Pillar Box of any description, complete all as specified and as directed :- INCOMMER :- (a) MCCB 100 Amp, 3 Pole, 16 kA, 415 Volt-02 No. OUT-GOINGS :- (b) MCCB 63 Amp, 3 Pole, 16 kA, 415 Volt-03 No. (c) Digital Ammeter 0-200 Amp with suitable Size CT"s and -01 No. Selector Switch (d) Digital Volt Meter 0-500 Volt with Selector Switch-01 No. (e) Indicating Lamp LED type in Incomming Phase-02 Set (f) Internal Wiring with PVC insulated Copper Conductor Multi-stranded Cable 1100 Volt grade IS-694 marked of appropriate gauge including Copper Lugs (g) Connection from MCCB to Bus-bars with Solid Copper Conductor.
99M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, Connectedto GalvanisedEarth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, Connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregates) and Pre-cast RCC Cover Slab of Size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregates), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Earth Works in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Old Unserviceable Earthing of any description, complete all as per specified and as directed.
100M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, Connected with and including Galvanised Earth Strip of Size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and Connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregates) and Pre-cast RCC Cover Slab of Size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregates), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Old Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
101M&L Earthing with Copper Earth Plate Electrode 600x600x3.15mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, Connected with and including Copper Earth Strip of Size 20x3.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and Connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregates) and Pre-cast RCC Cover Slab of Size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregates), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Old Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
102M&L Chemical Earthing with Solid Rod Technology CPRI Tested Rod dia 17.2mm, 3.0 Metre in Length, having Copper coating of 250 micron along with Poly Plastic Pit Cover and 2 Bags of Ground Enhancement Materials with Exothermic Brazing for Joints as per IS:3034 including all necessary Earth Works and all as shown in MES Schedule Part-I and Testing on Completion including down/out Old Unserviceable Earthing of any description, complete all as per specified and as directed. MAKE : OBO BETTERMAN/ ERICO/ FURSE/ INGESCO/ JMV LPS/ Make approved by E-in-C"s Br./having sufficient Experience in this Field. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail