Tender For Illumination Improvement Works At Fsd Budhlada U/D Bathinda..
Tender Value
28.53 Lakhs
Estimated cost
Bid Submission
19 Jun 2023
0 days left
EMD
57080
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
budhlada → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Illumination Improvement Works At Fsd Budhlada U/D Bathinda..
BOQ
| Sl. No. | Item Description |
| 1 | Sub Head -I( Conduit laying )Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 2 | 25 mm |
| 3 | Sub Head -II ( Wiring ) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 4 | Sub Head -II ( Wiring )S/D of following sizes of FRLS PVC insulated copper conductor ISI marked single core cable in the existing surface/recessed steel/PVC conduit as reqd. 3 X 1.5 sq mm |
| 5 | 4 X 1.5 sq mm |
| 6 | 5 X 1.5 sq mm |
| 7 | 6 X 1.5 sq mm |
| 8 | 7 X 1.5 sq mm |
| 9 | 8 X 1.5 sq mm |
| 10 | 9 x 1.5 sq mm |
| 11 | 3 X 2.5 sq mm |
| 12 | 6 X 2.5 sq mm |
| 13 | 3 X 4 sq mm |
| 14 | Sub Head -III(Switchgear and earthing)Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.6 Module (200mmX75mm) |
| 15 | 12 Module (200mmX150mm) |
| 16 | Sub Head -III(Switchgear and earthing) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 17 | 15/16 A switch |
| 18 | 3 pin 5/6 A socket outlet |
| 19 | 6 pin 15/16 A socket outlet |
| 20 | Sub Head -III(Switchgear and earthing)Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 A switch |
| 21 | Sub Head -III(Switchgear and earthing)Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 22 | Sub Head -III(Switchgear and earthing)Supplying and fixing of horizontal type three pole and nuetral sheet steel MCB distribution board, 415Volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc., as required (but without MCB/RCCB/Isolator ) 4 way (4 + 12), Double door |
| 23 | Sub Head -III(Switchgear and earthing)Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way , Double door |
| 24 | Sub Head -III(Switchgear and earthing)Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,\"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DBomplete with connections, testing and commissioning etc. as required. Single pole |
| 25 | Single pole and neutral |
| 26 | Triple pole and neutral |
| 27 | Sub Head -III(Switchgear and earthing)Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A |
| 28 | Sub Head -III(Switchgear and earthing)Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 29 | Sub Head -III(Switchgear and earthing)Dismantling the existing switch cover/plate alongwith damaged tumbler type switches and Providing and fixing of phenolic laminated sheet suitable for existing metal box including switch cutting extra as required. |
| 30 | Sub Head -III(Switchgear and earthing)Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 31 | Sub Head -III(Switchgear and earthing)Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. |
| 32 | Sub Head -III(Switchgear and earthing)Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.. |
| 33 | Sub Head -III(Switchgear and earthing)Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 34 | Sub Head -III(Switchgear and earthing)Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 35 | Sub Head -III(Switchgear and earthing)Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from FRLSom earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 36 | Sub Head -III(Switchgear and earthing)Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 37 | Sub Head -III(Switchgear and earthing)Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 38 | Sub Head -IV ( Fittings )Supplying, installation, testing andcommissioningof 2 x 20W Retrofit type Photon Ultra bright LED polycarbonate tubelight along withIndustrial Box type Luminaire batten suitable for TwinT8 LED Tube on wall/truss for fixing LED tube including connection, testing as required. |
| 39 | Sub Head -IV ( Fittings )Supplying, installation, testing andcommissioningof 20W LED tube alongwith Industrial Batten of Environmental friendly, long life, corrosion resistant, impact proof, surface mounting IP66 luminaire with PC housing & opal finish cover suitable for LED tubes and fixing on wall/truss by using necessary clamps and also dismantling the existing fitting. |
| 40 | Sub Head -IV ( Fittings )Supplying, installation, Testing and commissioning of 45 watt LED 5700K type LED streetlight made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection with impact resisitance of IK07 and fixing on truss /wall/ pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required. |
| 41 | Sub Head -IV ( Fittings )Supplying, installation, Testing and commissioningof70 watt LED LED Well Glass fitting of Environmental friendly, energy saving long life corrosion resistant, vertical/horizontal surface mounting pressure die-cast aluminium well glass luminaires with high power LED as light source and fixing on truss /wall/ pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required. |
| 42 | Sub Head -IV ( Fittings )Supplying, installation, Testing and commissioning of 35 watt LED 5700K Post top lantern type- IP65 with high power LEDs as light source and fixing on pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required. |
| 43 | Sub Head -IV ( Fittings )Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 44 | Sub Head VI - Cabling WorksSupply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required.2 x 16 sq.mm |
| 45 | 2 x 10 sq.mm |
| 46 | 4 × 16 sq.mm |
| 47 | 4 x 25 sq.mm |
| 48 | Sub Head VI - Cabling WorksProviding, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required100 mm dia |
| 49 | Sub Head VI - Cabling WorksSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 16 sq. mm (22mm) |
| 50 | 2 X 10 sq. mm (19mm) |
| 51 | 4 X 16 sq. mm (28mm) |
| 52 | 4 X 25 sq. mm (28mm) |
| 53 | Sub Head VI - Cabling WorksLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Up to 35 Sq mm |
| 54 | Sub Head VI - Cabling WorksLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.up to 35 sq.mm.Up to 35 Sq mm |
| 55 | Sub Head VI - Cabling WorksLaying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Up to 35 Sq mm |
| 56 | Sub Head VI - Cabling WorksLaying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) (DSR 2022 -Item no.7.7.1) |
| 57 | Sub Head VI - Cabling WorksSupplying and fixing street light loop in loop out boxes with PVC outdoor weatherproof Box of size 8\"x6\"x4\"with 1 No. 6A SP MCB, 2/4 way strip connector i/c testing as reqd. |
| 58 | Sub Head VI - Cabling WorksSupplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 meter length along the pole for protection of under ground cable as required |
| 59 | Sub Head VI - Cabling WorksSupply and installation of 400x400x250 mm 16SWG MS sheet fabricated loop in loop out box with 4 strip of 100 A aluminium bus bar to the required location with proper electrical connections. |
| 60 | Sub Head VI - Cabling WorksS/F of 200 Amp Kit Kat fuse complete set for main board in switch room. |
| 61 | Sub Head VI - Cabling WorksProviding and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.200 A,36KA,FPMCCB |
| 62 | Sub Head VI - Cabling WorksSupply and fixing 5.0 mtrs of 40 mm GI pipe (medium grade) on truss for light fixtures with necessary clamping at both the ends of the pipe as required. |
| 63 | Sub Head VI - Cabling WorksSupplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish Paint etc. as required. |
| 64 | Sub Head VI - Miscellaneous worksRemoving the existing aluminium wire from conduit, main board, sub-main boards, switch boards, tube light fittings etc., and shifting the same to stores etc., as required.( for shed no 1,2 and 3) |
| 65 | Sub Head VI - Miscellaneous worksProviding and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 66 | Sub HeadVII - Credit ItemsLess credit for dismantaled old damaged metal scrap |
| 67 | Sub HeadVII - Credit ItemsLess credit for dismantled old damaged PVC insulated Al wire |
| 68 | Sub HeadVII - Credit ItemsLess credit for dismantaled old damagedSingle pole MCB 6 to 32 Amp |
| 69 | Sub HeadVII - Credit ItemsLess credit for dismantaled old damagedSingle SPN 6 to 40 Amp |
| 70 | Sub HeadVII - Credit ItemsLess credit for dismantaled old damaged 5/6Amp piano/round type switch |
| 71 | Sub HeadVII - Credit ItemsLess creditfor dismantaled old damaged70/150W street light HPSV fitting |
| 72 | Sub HeadVII - Credit ItemsLess creditfor dismantaled old damaged40W Flourescent fitting |
AI Tender Summary
Tender Timeline
Jun 09, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedJun 19, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJun 20, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender