Tender For Regular And Breakdown Maintenance Works To Be Carried Out In Electrical Division And Mechanical Maintenance Works During The Year 2023-2024 At Bbgtps, chennai-Tamil Nadu

Tamil Nadu Generation And Distribution Corporation Limited-TANGEDCO has published Tender For Regular And Breakdown Maintenance Works To Be Carried Out In Electrical Division And Mechanical Maintenance Works During The Year 2023-2024 At Bbgtps. Submission Date for this Tender is 26-06-2023. Electrical Maintenance Tenders in chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

38094977
Tender For Regular And Breakdown Maintenance Works To Be Carried Out In Electrical Division And Mechanical Maintenance Works During The Year 2023-2024 At Bbgtps
Open Tender
Indian
Tamil Nadu
chennai
26-06-2023

Tender Details

Regular And Breakdown Maintenance Works To Be Carried Out In Electrical Division And Mechanical Maintenance Works During The Year 2023-2024 At Bbgtps Regular And Breakdown Maintenance Works To Be Carried Out In Electrical Maintenance, Meter And Relay Test, Control And Instrumentation In Electrical Division And Mechanical Maintenance Works During The Year 2023-24 At Bbgtps

Key Value

Document Fees
Refer document
EMD
INR 70000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: AMC/Maintenance for BBGTPS
Sl. No. Item Description
1MRT - PREVENTIVE MAINTENANCE WORKS
2Replacement / maintenance of worn out carbon brushes in Unit III/ Unit IVGenerator shaft Earthing & Rotor E/F sensing carbon brush.
3Works in110KV Breakers /Generator Transformers/ Battery Chargers /Diode Voltage Regulator panel.
4Works inStation Transformers.
5Works in Station battery / Unit III & IV Generator & CO2 protection battery / Unit I,II,III, IV battery / CC battery / D.G.set battery.
6Works inCT/ PT/ CVT/ Wave Trap/ LAS/ Isolators
7Works in Earth Switch
8Works onConnectors / Fittings in 110KV Bus .
9Works in Station Battery DCDB Module
10MRT - ROUTINE MAINTENANCE WORKS
11Calibration of Protection relays (Generator / 11KV SWGR / 415VLT SWGR / Unit III & IV 415V MCC/ FWPH).
12Calibration of Power Relays (Generator /415V LT SWGR)
13Servicing of MCC modules and calibration of Meters.
14Testing of station transformer / Generator transformer/ WTI/ OTI/ UAT/AC Exciter and permanent magnet generator/ D.G set alternator power circuit / Breaker contact resistance/ AVR panel/ LT &HTBreaker circuits.
15Winding Resistance and IR value of Generator Transformers/IR value of11KV LT Bus duct/ IR value of Generator stator.
16Checking of Diode wheel in Exciter for Unit I to IV / Testing of Switch yard interlock circuits.
17Testing ofUnit I to IV Generator space heater and panel heater / Terminal tightness of 110KV SWYD equipment boxes.
18Terminal tightness and cleaning of control panels (CCR/11KV SWGR /LT SWGR /SCR /FWPH/CVT)
19Servicingof Station (52AS) & UAT (52AR) Breakers / Terminal tightness of change over circuit/ MCC modules/ GT protection panel/ GT Marshalling boxes.
20Servicing of 415V LT & 11KV HT Breakers, and testing Auto/Manual circuits
21Terminal tightness of RTCC Panel /OLTC panel / draw out type CT/PT of GAC / DG set control panel.
22Cleaning of Cable Gallery trays etc.
23Cleaning / Terminal tightness of AVR Panel of Unit I to IV.
24Testing of IR value, BDV oil test, silica gel replacing works inGenerator Transformer/ Station transformer
25Collecting & sending of oil samples from Generator Transformer & Station Transformer to R&D lab for DGAtest& BDV test
26Generator Transformer OLTC gear box mechanism and Tap Position Indicator mechanism servicing work.
27110KV Breaker open/close timetesting works.
28Calibration of pr.gauge/pr.switch/Meters
29Generator Transformer Tan Delta test
30Earth pit cleaning, tightening of earth contacts and resistance value measuring.
31Conducting Load test on 125 Volt and 220 Volt Battery set.
32MRT - BREAKDOWN ANDGENERAL WORKS
33Checkingof control circuits and replacing the defective contactors in Unit I to IV MCC modules/ GT Marshalling box/ control panels/ 415V SWGR/ RTCC, OLTC panels/ SCR, AVR panels.
34Checking of protection circuits and replacing the defective relays / Timers after testing in Unit I to IV panels/ GT Marshalling box/ 415V SWGR/ SCR, SCB and AVR panels/ Synchronising Trolley
35Testing of control / Indication / Annunciation circuits and replacing the defective control switches/ push button/ Hooters/lamp holders in Unit I to IVMCC modules/ GT Marshalling box/ HT SWGR/ 415V SWGR/ RTCC / OLTC panels.
36Testing and replacing the defective Annunciation bulbs / indicating bulbs in various panels of Unit I toIV MCC modules/ GT Marshalling box/ control panels/ 415V SWGR/ RTCCpanels.
37Testing and replacing the defective AVR panel cards / Annunciation cards of Unit 1 to IV
38Rectification of DC cable fault.(Unit I to IV/ 11 KV SWGR/ FWPH/ DG Set/ RTCC/OLTC / AVR Panels / 110 KV switch yard.)
39Attending to defect in HT Breakers/ LT Breakers / FWPHbreaker / DG Set Starting Motor
40Testing of 110 KV CT & PT/Generator Transformer.
41Testing of LT CT & PT and control Transformer.
42Testing of Unit 52AS and 52AR LT Breaker and itschange over circuits.
43Replacementwork of Limit Switch/Pressure Switch /Pressure Gauge/Spring Charging Motor/Carbon Brush in spring chargingmotor.
44Replacement workof defective trip coil/Closing coil/Control contactor of 110KV Breaker &Cooler fan/OTI/WTI/Bearing replacement in cooler fan of Generator Transformer/Topping up of SF6 gas.
45Replacementwork of defective oil pump/OLTC motor in Gen.Transformer/OLTC gear box worn out bearing changing.
46Replacement work of defective contactor /Relays/ timers and Oil line Valve leak attending works
47Replacementwork of defective battery/Battery connector,relays,Timer,Thyristor,condenser/Choke/ Transformer/PCB/Meter/Switches in Battery charger.
48Replacementwork of defective Moving contact/Fixed contact of isolator or Earth switch with spare one/Mechanism stud/Limit switch/Isolator motor/Contactor/Castle key/Interlocks in Isolator MOM box.
49Toppingup of Transformer oil with filtering arrangements including rental and transporting charges of filter machine.
50Replacementwork of defective ‘T’ clamps/ Breaker clamps/ P.G.clamp/ switch end clamp/CT clamp/PT clamp.
51Replacement work of defectiveconductor inMain Buses &Strung buses.
52Replacementwork of defective conductor interconnecting the CT, Isolator & Breakers.
53Painting of MOM box/ marshalling box/ CT, PT, earth switch box and other panels.
54Cable laying work.
55110KV CT / PT oil leak attending work by replacing the worn out ‘O’ rings , gaskets and topping up of transformer oil & Nitrogen gas
56Handling of materials at site/stores of Weight above 150 Kg
57Handling of materials at site/stores of Weight between 100 to 150 Kg
58Handling of materials at site/stores of Weight upto 100 Kg
59C & I - FREQUENTLY OPERATING WORKS
60Works in Batteries and Battery Charger in C&I Control Panels
61Works in Control Panel for CO2 Fire Fighting System in Unit I to IV.
62Cleaning of all Field Instruments like Gauges, Switches, Indicators, Speed Pick-ups, Solenoid Valves, Scanners, Spark Plugs ,Vibration Sensors and Smoke Detectors in Unit I to IV and Auxiliaries.
63Cleaning of Cards in Mark-IV of UnitI to IV.
64Carrying out works in Mark- IV of Unit I to IV such as cleaning, checking and allied modules works
65Terminal tightness checking in Junction Boxes and Modules, Ignition Transformers in Unit I to IV and auxiliaries.
66Works in Intercom Instruments, Intercom Exchange Cards, Junction Boxes healthiness checking.
67Works in Page & Party System in the plant includes Instruments, Junction Boxes healthiness checking and checking the healthiness of all lines.
68Works in CCTV System in the plant includes Cameras, Junction Boxes healthiness checking and checking the healthiness of all lines, Displays & DVRs.
69Carrying out works in field instruments such as Pressure gauges & Switches for any leakage of oil, air, water & fuel and checking readings for correctness and analysis if necessary and attending the defects noticed if any.
70Cleaning, Checking the terminal tightness in Lighting Distribution boards and pillar boxes.
71Cleaning, Checking the terminal tightness of street light pole junction boxes.
72Cleaning, Checking terminal tightness in junction boxes ofSwitchyard tower light fittings and High mast tower lights.
73Checking the healthiness of motor terminal blocks, terminal lugs, power fuses, power contactors and end bearing noise of Unit I to IV and Auxiliaries Motors and Modules.
74Taking Energy Meter reading
75Carrying out works in field instruments such as flow meters, level indicators & switches, Temperature gauges & switches for any leakage of oil, air, water & fuel and checking readings for correctness and analysis if necessary and attending the defects noticed if any.
76C & I - RARELY OPERATING WORKS
77Checking the healthiness of RTD’s for Generator Winding Temperatures & indicator in Unit I to IV and related panel.
78Works in Control Panel in Inlet Air Filter of Unit I to IV and Auxiliaries Panels related to C&I Control panels.
79Calibration of Pressure Gauges, Differential Pressure Gauges & Temperature Gauges of Units I to IV and Auxiliaries.
80Calibration of Pressure Switches, Differential Pressure Switches, Temperature Switches, Transducers, Digital indicators of Units I to IV and Auxiliaries.
81Testing of Flame Scanners, Spark Plugs, Level Switches, Limit Switches, Level indicators, Pick- ups, Vibration Sensor, Naphtha Sensors,Smoke Detectorsand Fire Detectors in Unit I to IV and Auxiliaries.
82Testing of Solenoid Coil and Solenoid Valves, Air Diaphram Valves in Unit I to IV and Auxiliaries. System.
83Loop checking the alarms in Mark-IV of Unit I to IV by simulating the necessary parameters.
84Cleaning, Checking terminal tightness and maintenance works in Distribution transformerand Lighting transformer.
85Lubrication of motors by applying grease, testing of IR value, DC resistance of motor windings, load current measurement, Base bolt tightness of Unit I to IV and Auxiliaries Motors.
86Cleaning, checking of tightness, testing of IR value in LT Bus bars.
87Cleaning of Tube light fitting provided in entire locations of BBGTPS
88Checking Earthing connection in Motors, Transformers and Modules, etc.
89C&I- BREAKDOWN/ GENERAL WORKS
90Releasing of old control cable and telephone cable above 4-pair & laying of new cable in a trench/ by clamping / bydiggingthe earth in between unit I to IV and Auxiliary locations.
91Releasing of old telephone and CCTV cable 4-pair and below, laying of new cable in trench / by clamping / by digging the earth in intercom system.
92Replacement of Thermocouple in Unit I to IV.
93Intercom Faultand CCTV fault attending work (including line and junction box faults rectification).
94Page & Party Fault Attending work (line and junction box faults rectification).
95Mark-IV Cards Replacement in Unit I to IV.
96Impulse Line leak attending work by changing the ferrules and tightening in Unit I to IV and Auxiliaries.
97Impulse Line re-tubing work in Unit I to IV and Auxiliaries.
98Removing any Faulty C&I field instruments and calibrating / testing in Unit I to IV and Auxiliariesand Re-fixing the instruments in the system.
99Releasing the batteries, Transporting it to battery shop, servicing, re-charging and bring back to site and re-fixing batteries for C&I Control panels.
100Defect rectification in Control Panels related to Unit I to IV and Auxiliary location panels.
101Defect rectification work in Mark-IV Panels of Unit I to IV.
102Painting of Control Panels, junction boxes, modules in Unit I to IV and Auxiliary location motors and C&I field instruments.
103Handling of Materials to the work spot up to 100 Kg
104Handling of Materials to the work spot up from 100 Kg to 150 kg.
105Releasing of Instruments during shut down or for Mechanicalwork and fixing the same after completion.
106Testing of new materials /equipments.
107Releasing the failed motor (i.e.) decoupling from the air duct / pump, etc. for bearing replacement / rewinding and re-fixing the healthy motor after bearing replacement / rewinding For 55 kW, 45 kW and 37 kW (AOP) capacity motors.
108Releasing the failed motor (i.e.) decoupling from the air duct / pump, etc. for bearing replacement / rewinding and re-fixing the healthy motor after bearing replacement / rewinding. Unit III & IV 88TK motor (37 kW) and 8KW EOP motor (DC) of Unit I & II.
109Releasing the failed motor (i.e.) decoupling from the air duct / pump, etc. for bearing replacement / rewinding and re-fixing the healthy motor after bearing replacement / rewinding. For 30 kW, 26 kW, 22 kW, 18.5 kW and 15 kW capacity motors.
110Releasing the failed motor (i.e.) decoupling from the air duct / pump, etc. for bearing replacement / rewinding and re-fixing the healthy motor after bearing replacement / rewinding. For 11 kW, 10 kW, 9.3 kW, 8 kW, 7.5 kW, 5.5 kW, 5 kW, 3.7 kW and 2.2 kW capacity motors.
111Releasing the failed motor (i.e.) decoupling from the air duct / pump, etc. for bearing replacement / rewinding and re-fixing the healthy motor after bearing replacement / rewinding. For 1.5 kW, 1.1 kW, 1 kW, 0.75 kW,0.55kW ,0.37 kW capacity motors.
112LT cable fault
113LT cable laying work: Removing, Re-laying in cable trench / by clamping / or by Digging 0.6 Meters on the earth - Power cable laying upto 25 sq.mm.
114LT cable laying work: Removing, Re-laying in cable trench / by clamping / or by Digging 0.6 Meters on the earth - Power cable laying above 25 sq.mm. to 120 sq.mm.
115Attending to the defect in Motors and modules (Power Circuit) of Unit I to IV and Auxiliary location motors.
116Replacement of tube light bulb, choke, starter, MCB and attending to defects in Stabilizer, fan at various locations.
117Rectification of Switch Yard tower lights, Unit I to IV Air craft warning lights, Flame proof fittings and Street light fittings.
118New Wiring for Wall Mounted Tube Light, Fan points, plug points, street light fittings, etc.
119Extension of Power supply for lighting, welding, drilling, grinding,etc. for other agency.
120Replacingof worn out Earthing connection in Equipments / Motors.
121Testing of New lighting materials, power contactors, etc.
122Attending to the defect in Distribution Transformer and Lighting transformer.
123MECHANICAL MAINTENANCE WORKS
124Cleaning of Accessory compartments
125Cleaning of Turbine compartment
126Cleaning of Load Gear & Exciter Compartments
127Cleaning works in GT auxiliaries
128Cleaning the outer areas of GTs
129Cleaning the outside surfaces of drain tanks
130Turbine lube oil/Naphtha Lubricity additive top up
131Lubrication in GT auxiliaries
132Emptying the lube oil drain tank in units 1 / 2
133Emptying fuel from units 1 / 2 drain tanks and moving, filling up this fuel into unit-3 drain tank
134Grease/OilLubrication of valves
135Flex seal checking & bolts tightening
136Removing guard for inspection of the starting clutch and refixing
137Cooling water makeup work in GTs
138Removing manhole door of inlet air/exhaust ducts for inspection and re-fixing
139Unforeseen maintenance works for 2 hours period
140Unforeseen maintenance works for 4 hours period
141Unforeseen maintenance works for one dayperiod
142Inlet air filters cleaning works units I / II
143Inlet air filters cleaning works units III / IV
144Cooling water radiator cleaning with Air/ water in GT units
145Removal of Fuel check valves/Water Injection Check Valves for checking and refixing
146Removal of Fuel Nozzle assemblies, cleaning and refixing
147Removal of Generator Air Filters, cleaning and refixing
148Cleaning/Replacement of lube oil filter / lube oil in Diesel Engines
149Cleaning/Replacement of Fuel filters/Air Filters in Diesel Engines
150Rectification works involving Gas Cutting / Welding
151Cleaning & Painting pipelines/equipment at ground level per Sq.m
152Cleaning& Painting pipelines/equipment above ground level per Sq.m
153Handling of materials at site/store of weight above 150 Kg
154Handling of materials at site/store of weight between 101 to 150 kg
155Handling of materials at site/store of weight upto 100kg
156Moving and installing mobile pump for dewatering
1571 CUM R.O and D.M plant filters cleaning