Rural Development Government Departments Closing in 0 days TDR #38091960

Construction Of Paccs Building At Badgaon, Block - Tandwa, District - Chatra

Issued by Government Departments · tandwa, Jharkhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Jun 2023
0 days left
EMD
49000
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tandwa → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Paccs Building At Badgaon, Block - Tandwa, District - Chatra

BOQ

Name of Work: Construction of PACCS Building at Badgaon, Block - Tandwa, District - Chatra
Sl. No. Item Description
1Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil itemA) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
2Earth filling infoundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earthobtainedfrom excavation offoundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I.(mode of measurement compacted volume)
3Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
4Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
5Providing designation 75B brick work inC.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
6Providiag designation 75B brick work in Cement Mortar (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing taxes and royalty all complete job as per building specificition and direction of E/l.
7Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
10Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated andgroutedwithfinesand,includingnecessaryexcavation,levelling& dressing & finishing the top smooth.
11Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
12Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
13Reinforcedcementconcreteworkinbeams,suspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).In Lintel Band
14Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete.
15Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and platform.
16Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
17Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts.
18Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges.
19Providing TMT steel reinforcement as per approved design and drawing excluding carriage of M.S bar to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.8mm dia bar
20Providing TMT steel reinforcement as per approved design and drawing excluding carriage of M.S bar to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.10mm dia bar
21Providing TMT steel reinforcement as per approved design and drawing excluding carriage of M.S bar to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.12mm dia & above bar
22Supplying, Fitting and fixing M.S grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site hoisting as per building specification and direction of E/I.
23Providing and fixing fan hook of 16mm dia TMT M.S. bar 1 meter long bent to required size and shape placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I.
24Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I.
25Supplying, fitting and fixing 20 gauge G.C.I. sheet gate fitted on. M.S. angle frame of size 60 x 60 x 6mm including cost of fabrication providing necessary locking arrangement with haskal end dommy duly fixed in P.C.C. (1:2:4) block of required size, applying a priming red lead paint over steel work taxes all complete as per drawing specification and direction of E/I.
26Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622/ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (Size of Tile 600 x 600mm)
27Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete.
28Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
29Providing 12 mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes androyalty all complete as per specification and direcition of E/l.
30Providing 6mm cement plaster (1:4) in ceiling with clean coarse sand of F.M 1.5 including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I.
31Providing 12 mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 1.5 mm cement punning including screening, curing with all leads and lifts of water, scaffolding, taxes androyalty all complete as per specification and direcition of E/l.
32Providing 12 mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 with 1.5 mm cement punning including screening, curing with all leads and lifts of water, scaffolding, taxes androyalty all complete as per specification and direcition of E/l.
33Providing 12mm water proof cement plaster (1:3) with clean coarse sand of F.M 1.5 with 5% cico or any other approved water proofing compound including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I.
34Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
35Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty where required, scaffolding, washing of floors and taxes all complete as per specification and direction of E/I.
36Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
37Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly, scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
38Providing 150mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
39Supplying, fining and fixing viterous white glazed earthen ware I.W.C of Parry Hindustan or any other I.S.S approved make with 100mm H.C.I \"p\" trap 15 liters C.I. or C. pull and let go flushing cisternofnames or other I.S.S equivalent make, complete with all fittings. C.I or C.Cbrackets 32mm alkathene/P.V.C telescopic flush, pipe about 2M long with one brass coupling and clamps G.I chain and pull includingsupplyingand fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I body brass spindle stope cock of weight not less than 50 grins. 15 mm P.V.C connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.580mm long with 10 litre low level P.V.C. cistern
40Supplying, fining and fixing 40mm high viterous white glazed earthen ware E.W.C with P-trap of Parry, Hindustan or any other I.S.S. make including supplying and fixing 15 ltr. C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle or R.S. brackets with telescopic flush pipe with brass coupling and plumber joints spindle stop cock of approved quiality weight not less than 450 grams, 15 mm P.V.C alkathene pipe 45cm long with brass coupling at both ends and white/black plastic solid state seal and lead of Commander/Cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern wtc. with two coats of approved paint over a coat of red oxide primeing, all complete as per specification and direction of E/I.
41Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware Urinal of Parry Hindustan or any other I.S.S approved make with 5 liters capacity C.I. outomatic flushing cistern ofReliance or other I.S.S approved make with all fittings with C.I or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15 mm C.I body brass spindle stop cock of approved quality weight not less than 400 grams, 15 mm P.V.C./Alkethene pipe 450mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint over a primer coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/I.
42Supplying, fitting and fitting vitreous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed C.I. or M.S. brackets 32m C.I. brass waste, 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
43Providing and fixing male ended 15mm dia brass bib cock of approved quality (wt. not less than 350 gms.) with extra socket all complete as per specification and direction of E/I.
44Providing and fixing brass/C.I. stop cock of approved quality as per specification and direction of E/I.Brass stop cock - 15mm dia
45Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.20mm dia
46Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.32mm dia
47Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) 110mm dia Single socketed pipes.
49Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee with door - 110mm
50Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° - 110mm
51Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain) - 110mm
52Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
53Carriage of materials by diesel truck including loading at source, unloading at work site and stacking properly, labour etc. all complete as per direction of E/I.Cement
54Sand
55Stone Chips
56Steel
57Bricks
58Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.Group B
59Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
60Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire
61Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
62Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
63Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm dia
64Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm dia
65Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
66Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
67Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
68Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way, Double door
69Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"B\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
70Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"B\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and neutral
71Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required.
72Supplying and laying 8 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
73Providing and fixing 1200mm Ceiling fan.
74Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
75Providing and fixing of LED Bulb - 9/10 watt
76Cost of drilling 200mm x 165mm x 100m deep bore well in all kinds of soil and rock in rural area for installation of pump set with D.T.H. rig all complete! including supplying all materials, labours, tools, drilling rig, air compressor and equipment as well as fuel, lubricants for making boring and cost of transporting/charges of rig machine & other vehicles up to site of the work as per specification and direction of E/l.Up to 50 mtr Below G.L.
77Cost of drilling 200mm x 165mm x 100m deep bore well in all kinds of soil and rock in rural area for installation of pump set with D.T.H. rig all complete! including supplying all materials, labours, tools, drilling rig, air compressor and equipment as well as fuel, lubricants for making boring and cost of transporting/charges of rig machine & other vehicles up to site of the work as per specification and direction of E/l.Beyond 50 mtr. up to 125 mtr. Below G.L.
78Supplying all materials, labours, equipments for lowering 200mm dia M.S. ERS pipes as casing of well thickness 6mm for protecting the sites from falling during the process of drilling ail complete including carriage to work site.
79Supplying labour and equipments including 200mm dia. M.S. Cap and fitting and fixing over the tube well properly and taking it out as per direction of E/I.
80Supplying all tools, labours, equipments for lowering 32mm dia P.V.C. pipe in 3 mtr. length in the drilling bore of tube well etc. all complete job as per direction of E/I.
81Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sand content(beyond permissible limit), with required capacity air compressor, all as per requirement and direction of Engineer-in-charge.
82Supplying fitting and fixing of KSB/KIRLOSKER/CRI make 1.50 HP Submersible pump set having head of 135 metre including all taxes, royalty, etc.all complete job as per direction of E/I.
83Supplying fitting and fixing of 5 H.P. standard make starter panel board with arrangement of all necessary protection including all taxes,royalty etc all comlete job as per direction of E/I.
84Supplying fitting and fixing 3 core 4mm2 flat copper submersible cable FINOLEX/HAVELS make including all taxes,royalty etc all complete job as per direction of E/I.
85Goods & Services Tax (G.S.T.) @ 18%
86Labour Cess @ 1%

AI Tender Summary

OUR REF NO 38091960
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 16-06-2023
Authority
Authority Name Rural Works Department
Work Description Construction Of Paccs Building At Badgaon, Block - Tandwa, District - Chatra
Basic Detail
Tender No EE/NREP/CHATRA/15/2023-24
Bidding Type Tender
Location
City tandwa
State Jharkhand
Key Dates
Publish Date 09 Jun 2023
Submission Date 16 Jun 2023
Open Date 19 Jun 2023
Finance
Tender Value Ref. Documents
Tender Fee 5000
EMD 49000
Exemption Not Available
Document List
BOQ_97050.xls
SBD.pdf
1bb227b9-dfa7-4cb1-8272-f1b6f009fddc.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 09, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 16, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 19, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_97050.xls

pdf

SBD.pdf

html

1bb227b9-dfa7-4cb1-8272-f1b6f009fddc.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender