Tender For Repair And Maintenance To Water Supply Distribution Pipe, Control Panels, Motors, Pumps Of Water Supply Installations, Bore Well/Shallow Well And Overhead Tanks/Ug Sumps And Connected Works At Ins Kalinga Visakhapatnam Under Ge (P) Navy, visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Tender For Repair And Maintenance To Water Supply Distribution Pipe, Control Panels, Motors, Pumps Of Water Supply Installations, Bore Well/Shallow Well And Overhead Tanks/Ug Sumps And Connected Works At Ins Kalinga Visakhapatnam Under Ge (P) Navy. Submission Date for this Tender is 29-06-2023. Supply of Motor Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38077718
Tender For Repair And Maintenance To Water Supply Distribution Pipe, Control Panels, Motors, Pumps Of Water Supply Installations, Bore Well/Shallow Well And Overhead Tanks/Ug Sumps And Connected Works At Ins Kalinga Visakhapatnam Under Ge (P) Navy
Open Tender
Indian
Andhra Pradesh
visakhapatnam
29-06-2023

Tender Details

Repair And Maintenance To Water Supply Distribution Pipe, Control Panels, Motors, Pumps Of Water Supply Installations, Bore Well/Shallow Well And Overhead Tanks/Ug Sumps And Connected Works At Ins Kalinga Visakhapatnam Under Ge (P) Navy Kalinga

Key Value

Document Fees
INR 500 /-
EMD
INR 68000.0 /-
Tender Value
INR 34 Lakhs /-

BOQ Items

Name of Work : REPAIR AND MAINTENANCE TO WATER SUPPLY DISTRIBUTION PIPE, CONTROL PANELS,MOTORS,PUMPSOF WATER SUPPLY INSTALLATIONS, BORE WELL/SHALLOW WELL AND OVERHEAD TANKS/UG SUMPS AND CONNECTED WORKS AT INS KALINGA VISAKHAPATNAM UNDER GE (P) NAVY KALINGA
Sl. No. Item Description
1Taking down the defective electric induction motor 125 HP capacity of Kirloskar make 415 volt, 3 phase by dismantling the electrical connections, removing the motor from bed, by decoupling with pump, transporting to workshop, dismantling the burnt out winding from rotor/stator and rewinding the rotor or stator with same type super enamelled copper wire of same gauge and with necessary insulating material, varnishing, backing, re-assembling the motor completely transporting back to site and alignment with the pump/compressor with electrical connections including testing and commissioning, complete all as specified and as directed. Note :- (i)Burnt out removed winding wire shall be property of contractor and credited through schedule of credit.
2All as per item No.1 above but electric motor of 100 HP capacity.
3All as per item No.1 here in before but Centrifugal pump motor 60 HP capacity complete all as directed by Engineer-in-Charge. Make : Beacon/ Kirloskar
4All as per item No.1 here in before but mono block pump motor 10 HP capacity complete all as directed by Engineer-in-Charge. Make : Beacon/ Kirloskar
5M&L for overhauling of centrifugal pump set 125 HP to 100 HP capacity of make Kirloskar, by dismantling completely and replacing unserviceable ball bearing, shaft sleeve, gland, neck ring gland rope shield, unserviceable Nut, bolt, washer etc. and reassembling the pump and fixing alignment to the original position and coupling with pump, complete all as specified and directed.
6All as per item No.5 above but 60 HP capacity centrifugal pump set.
7All as per item No.5 above but 10 HP capacity centrifugal pump set.
8Disconnecting and removing of existing mono block pump set 10 HP capacity of make Kirloskar, from the installed position after putting dummy plate to suction and delivery overhauling of the pump sets, replacement of bearing glandbush, gland nut neck ring, gland rope, greasing fixing in original position, and reconnecting the pump set and testing with load complete all as directed by Engineer-in-Charge.
9S&F in repairs, rubber coupling for 125 HP capacity motors/pumps complete all as specified and directed by Engineer-in-Charge.
10All as per item No.9 above but 100 HP capacity motors/pumps.
11All as per item No.9 above but 60 HP capacity motors/pumps.
12All as per item No.9 above but 10 HP capacity motors/pumps.
13S&F in repairs, terminal block for 125 HP capacity motors complete all as specified.
14S&F in repairs, terminal block for 100 HP capacity motors complete all as specified.
15S&F in repairs, terminal block for 60 HP capacity motors complete all as specified.
16S&F in repairs, terminal block for 10 HP capacity motors complete all as specified.
17M&L for repairs to pump shaft of any make with necessary metal filling and machining for 10 HP capacity pump set complete all as specified.
18S&F of DOL starter with no volt coil bimetal overload relay 415 volt 3 phase 50 HZ for 7.5HP capacity motors as in repairs complete all as specified.
19All as per item No.18 above but 10 HP capacity motor.
20M&L for painting to 5 HP capacity mono block/ centrifugal pump and motor with two coats of synthetic enamel paint over and including one coat of red oxide primer, including cleaning and degreasing the surface complete all as directed by Engineer-in-Charge.
21All as per item No.20 above but 7.5 HP to 10 HP capacity.
22All as per item No.20 above but 12.5 HP to 25 HP capacity.
23All as per item No.20 above but 30 HP to 60 HP capacity.
24All as per item No.20 above but 100 HP to 125 HP capacity.
25S&F in repairs rubber gasket for flangedjoints for 100 mm dia suitable for submersible/mono block pump sets & motors complete all as specified & directed.
26Supply only casing ring for centrifugal/mono block pumps 125 HP capacity.
27Supply only casing ring for centrifugal/mono block pumps 100 HP capacity.
28Supply only casing ring for centrifugal/mono block pumps 60 HP capacity.
29Supply only casing ring for centrifugal/mono block pumps 10 HP capacity.
30Supply only CI gland plate for centrifugal/mono block pumps 125 HP capacity.
31Supply only CI gland plate for centrifugal/mono block pumps 100 HP capacity.
32Supply only CI gland plate for centrifugal/mono block pumps 60 HP capacity.
33Supply only CI gland plate for centrifugal/mono block pumps 10 HP capacity.
34S&F pulley muff joint type with necessary foundry work 125 HP capacity centrifugal/mono block pumps.
35S&F pulley muffjoint type with necessary foundry work 100 HP capacity centrifugal/mono block pumps.
36S&F pulley muffjoint type with necessary foundry work 60 HP capacity centrifugal/mono block pumps.
37Disconnecting of electrical connections from the panel board, water outlet connections connected to the bore well, column pipe and lifting the submersible pump set alongwith the motor up to 10 HP capacity of any depth and column pipe of 80mm bore keeping aside carefully and flushing of bore well andlowering remove submersible pump setall item all as specified and directed by Engineer-in-Charge. Note: During taking out process if any pump set is fallen into the tube well contractor has to take out the same at his own cost.
38Taking down the submersible motor of 7.5 HP capacity any make 415 Volt, 3 phase by dismantling the electrical connections, removing the motor with pump from borewell, transporting to workshop, dismantling the burnt out winding from rotor/ stator and rewinding the rotor or stator with same type super enamelled copper wire of same gauge and with necessary insulating material, varnishing, backing, re-assembling the motor completely transporting back to site and alignment with the pump/compressor with electrical connections including testing and commissioning, complete, all as specified and a Note : New material coupler and cables will be measured and paid under respective item of the schedule under supply only rates.
39Supply only coupler heavy duty 100mm long of 50mm bore all as specified and directed.
40Supply only submersible cable PVC insulated sheathed 1100 volts grade multistranded copper conductor flat 3 core 6 Sq.mm. all as specified and directed.
41M&L for repairing of existing star delta starter cleaning of all power contactor terminals replacement if required and renewal of unserviceable perished copper wiring, aluminium/ copper lugs, push buttons and indication lamps etc, including necessary electrical connections and testing the motor with load all as directed by Engineer-in-Charge.
42M&L for cleaning of water supply under ground sump of capacity 2.0 Lakh gallons cleaning and sterilization, inside theUnderground/semi underground Over head/Sedimentation/clear water sumps through bacteriological treatment by using TERBAC G5/ Inchlor-5/ NB 10/ TERBAC G65/ Inoxi-60/ NB-69 and Ultra Violet Ray & Sodium Hypochlorite Solution. Make: Rays Cleantech/ Inus watertech/ Satya enterprise and equivalent as approved by GE. (Note : Item No 42 is here by continued as Srl Item No. 42.1 to 42.2)
43The Stages of cleaning is as follows:- (a) Firstis to drain out the water by using exit valve or high capacity dewatering system. (b) Secondis cleaning all the algae formation inside the tank and UG Sump by using TERBAC G10/ Inoxi-60/NB-69 or an equivalent laboratory tested branded chemical of the company and scrubbing the walls of the tanks. (c) Thirdis fresh water cleaning by high speed jet pump. (d) Fourthand first bacteria screening is decertification by using TERBAC-G5/ Inohlor-5/ NB-10 or equivalent. (e) Fifthis cleaning the floor of water tank by industrial vacuum cleaner. (f) Sixthis the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kills all suspended bacteria. (g) Seventh of cleaning and third bacteria screening is to sterilize the floor of the water tank by usingbranded strong oxidizing agent TERBAC-G65/ Inoxi-60/ NB-69 or equivalent.
44Note:- (i) Before cleaning, fix the sticker mentioning the date of cleaning & name of site and also providethe completion of sterilization of water tanks mentioningdate of cleaning, all the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scales and the same shell be reconnected after cleaning the OHT and the quoted rate is deemed to be included for the provision. (iii) Contractor will be responsible for rectification of complaints occurred during cleaning the tank i.e. no water in tank/ over flow due to broken of float valve/ blockage to be included in quoted rate. (iv) The work shall be carried out through specialized agency such as Rays cleantech/ Inus watertech/ Satya enterprise or equivalent as approved by GE
45All as per item No.42 above but 1.5 Lakh gallon capacity
46All as per item No.42above but 1.0 Lakh gallon capacity
47All as per item No 42 above but for over head tanks of capacity 1.00 Lakh gallons capacity
48M&L for removing of soil and debris from static tank of 3.6 mtr dia and 3.6 mtr depth by removing of debris upto a depth of 3.6 mtr feet from top level and removing debris from bottom of the well including dewateringby usingdiesel pump set cleaning with bleaching powder and wire brush after scrapping the walls and bottom of the sump complete includingrepair of wall /bottomwith PCC/Plastering work , white washing inside and one coat of cement based paint on out side surface of wallsof static tank all as specified and as directed.
49M&L for removing of soil and debris Shallow well of 5.5 mtr dia and 12.0 mtr depth by removing of debris upto a depth of 12.0 mtr from top level and removing debris from bottom of the well including dewateringby usingdiesel pump set cleaning with bleaching powder and wire brush after scrapping the walls and bottom of the sump complete includingrepair of wall /bottomwith PCC/Plastering work , white washing inside and one coat of cement based paint on out side surface of walls & roofof shallow well completeall as specified and directed.
50Cleaning of E/M installation yard (pump houses) by cutting bushes, shrubs/cleaning grass and other wild growth trees of upto satisfaction, complete all as directed by Engineer-in-Charge.
51Demolition of old unserviceable/brokenchamber and M&L for construction of brick masonry valve chamber 1200x900x 600mm sizewith plain cement concrete in 1:4:8 type D2 foundation and 15mm thick plaster in CM 1:4 on brick wall inside and brick chamber built in cement mortar 1:6 including providing of MS Sheet cover 3mm thick with angle iron (40x40x6mm)brackets grouted to brick wall duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with lifting handle and locking arrangement complete all as specified and directed:-
52All as per item No.49 above but 900x900x600mm size.
53M&L for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete as specified and directed
54S&F in repairs power contactors ML-1.5 along with timer switch and overload relaybydisconnecting control wiring from existing panel board including renewal of copper lugs etc. complete all as specified and directed by Engr-In-Charge.
55All as per item No.52 above but ML-2 power contactor.
56All as per item No.52 above but ML-3 power contactor.
57All as per item No.52 above but ML-4 power contactor.
58All as per item No.52 above but ML-6 power contactor.
59S&F 20mm dia. ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) including taking out old valve taking out old valve complete all as specified and directed.
60All as per item No.57 above but 25mm dia.
61All as per item No.57 above but 40mm dia.
62All as per item No.57 above but 50mm dia.
63S&F 200mm dia. cast iron foot valve flanged type as per IS-4038 PN-2 having sheet Gunmetal disc face ring- Nitrile rubber, Hinge pin stainless steel AISI-410 with Cast iron bolted stainer with necessary nut, bolt, washers etc, complete including taking out old valves complete all as specified and directed.
64All as per item No.61 above but 150mm dia.
65S&F 20mm dia. gun metal globe or gate valve with iron wheel head,screwed both ends for iron pipe including taking out old valves complete all as specified and directed.
66All as per item No.63 above but 25mm dia.
67All as per item No.63 above but 40mm dia.
68All as per item No.63 above but 50mm dia.
69Servicing of sluice valve of 80mm dia. including replacement of gland packing, spindle chuck nuts & bolts washers etc complete all as specified and directed.
70All as per item No.67 above but 100mm dia.
71All as per item No.67 above but 150mm dia.
72All as per item No.67 above but 200mm dia.
73S&F in repairs, voltmeter 3 phase 415V,50Hzdigital type (0 - 500 Volt) with necessary electrical connections to suit existing panel etc complete all as specified and directed.
74S&F in repairs pressure gauge (0-14 Kg/Cm²) including necessary specials and provision of suitable ferrule etc., complete all as specified and directed.
75S&F in repairs ammeter 3 phase 415V,50Hz digital type (0-200 Amps) with necessary electrical connections to suit existing panel etc complete all as specified and directed.
76S&F in repairs cast iron gland covers on top of sluice valve suitable for 80mm dia. sluice valves complete all as directed and
77All as per item No.74 above but 100mm dia.
78All as per item No.74 above but 150mm dia.
79S&F 200mm bore Non Return Sluice Valve cast steel, type PN-1.6 both end flanged type with necessary nuts, bolts and washerscomplete all as specified and directed.
80All as per item No.77 above but 150mm dia.
81S&F 200mm bore Air Release Valve cast steel, type PN-1.6 both end flanged type with necessary nuts, bolts and washerscomplete all as specified and directed.
82All as per item No.79 above but 150mm dia.
83Servicing of bore well electrical control panel includes replacement of burnt out lugs, unserviceable ML-1 contactors, cleaning of panel, checking of serviceability of timer and refixing, ensure of panel door closing, checking ofinternal wiringcomplete all as specified and directed by Engineer- in - charge.
84S&F in repairs 80mm dia sluice valve of cast iron body, PN 1.6, with both ends flanged, drilled at both the ends, conforming to IS-780, having gunmetal spindle with iron wheel at top complete with nuts, bolts, washers, rubber gasket champion-20, 3mm thick sheet complete all as specified and directed.
85All as per item No.82 above but 100mm dia.
86All as per item No.82 above but 150mm dia.
87S&F industrial flexible copper cable of size single core 35 Sqmm (80/0.6 dia.) complete all as specified and directed.
88M&L for arresting leaking ofrun lead joints for 150mm dia of CI/MS socket & spigot pipes by Caulking/burning out lead complete all as directed by Engineer-in-Charge.
89M&L for arresting leaking ofrun lead joints for 100mm dia of CI/MS socket & spigot pipes by Caulking/burning out lead complete all as directed by Engineer-in-Charge.
90M&L for arresting leaking ofrun lead joints for 80mm dia of CI/MS socket & spigot pipes by Caulking/burning out lead complete all as directed by Engineer-in-Charge.
91M&L for road cutting including excavation in trenches for laying CI/GI pipe not exc 45 cm wide and n.exc 75 cm depth as per site requirement including making good the disturbed surfaces with cement concrete (1:3:6) type C-1and top surface neatly finished to match with the existingcomplete all as specified and directed.
92Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depthand getting out in soft/ loose soil complete all as specified and as directed.
93Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms of excavated hard/dense soil complete all as directed.
94Removal of excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
95Cutting existing steel water tubing for additions/alterations (Each cut measured)complete all as directedof following bore :-
96(a) 15 mm bore
97(b) 20 mm bore
98(c) 25 mm bore
99(d) 40 mm bore
100(e) 50 mm bore
101Takingup or down steel water tubing and connections from trenches , walls/ floorsof following bore :-
102(a) 15 mm bore
103(b) 20 mm bore
104(c) 25 mm bore
105(d) 40 mm bore
106(e) 50 mm bore
107Refixing old serviceable tubing and connections, obtained from item No 94 above, in new or old position, after cleaning including supply and fixing new GI fittings such as Tee, bends, elbows, sockets, etc of medium grade , all as required at site complete as directedfor following bore :-
108(a) 15 mm bore
109(b) 20 mm bore
110(c) 25 mm bore
111(d) 40 mm bore
112(e) 50 mm bore
113Supply, laying and testing, galvanised iron pipe, medium grade with all fittings such as Tee, bends, elbows, sockets, reducer, tee union etc of medium grade, ISI marked fixed to walls/floors/ceilings/trenches including groove cutting for concealed plumbing as required at site and making good the damaged surfaces complete all as specified and directed for the following bores:-
114(a) 15 mm bore
115(b) 20 mm bore
116(c) 25 mm bore
117(d) 40 mm bore
118(e) 50 mm bore
119M&L for arresting leaking oflead wool joints of CI/MS socket & spigot pipes by Caulking complete all as directed by Engineer-in-Charge for the following bores.
120(a) 150mm dia size.
121(b) 100mm dia size
122(c) 80mm dia size
123M&L forarresting leaking ofrubber fibre board gasket joints of CI/MS flanged pipescomplete all as directed by Engineer-in-Charge for the following bores.
124(a) 150mm dia size.
125(b) 100mm dia size
126(c) 80mm dia size
127Taking up castiron pipe water main of size 150 mm dia. (Including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed
128Taking up castiron pipe water main of size 200 mm dia. (Including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed
129S&F 150 mm dia. cast iron pipes/DI Pipes with spigot and socket ends centrifugally cast, class LA, in any length, laid in trenches complete all as specified and directed.
130S&F200 mm dia. cast iron pipes/ DI Pipes with spigot and socket ends centrifugally cast, class LA, in any length, laid in trenches complete all as specified and directed.
131Supply only Sodium Hypochlorite Solution Available Chlorine Percent by mass by volume (as Cl): 10% Packing: 35 Kg. / 50 Kg. / 100 Kg. plastic recycled jars Availability of Test Report from a laboratory / study centre of any State University (a university established or incorporated by a Provincial Act or by a State Act) OEM must possess the following valid certificates: FSSAI, ISO 9001, ISO 14001, ISO 45001 Make: Decliback and equivalent
132Supply & installation of tank level sensor and indicator for UG Sump of following tech specification :- (i) Volcom srl make submersible tank level transmitter - submersible type, output loop powered 4-20mA, 2 wire output, Accuracy, IP rating : IP 68 upto 10m depth, Marine class approved & Ex approval in case medium is inflammable (ii) Junction box - Anodised aluminium IP 65 enclosure with terminals and cable glands (iii) Cable - 3 core internally shielded cable would be provided (50m) (iv) Indicator - Digital indicator(7 segment display/LCD screen), settable alarm function & power supply 220 50Hz.
133Dismantling of water storage tank of capacity n.exc 500 ltr and removing to store
134Dismantling of water storage tank of capacity Exc 500 but n.exc 1000 ltr and removing to store
135Dismantling of water storage tank of capacity Exc 1000 but n.exc 2000 ltr and removing to store
136S & F of 500 Ltr capacity ofRotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including tank nipple, tank adaptor, union etc complete fitting all as specified and as directed.
137S & F of 750 Ltr capacity ofRotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including tank nipple, tank adaptor, union etc complete fitting all as specified and as directed.
138S & F of 1000 Ltr capacity ofRotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including tank nipple, tank adaptor, union etc complete fitting all as specified and as directed.
139S & F of 2000 Ltr capacity ofRotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including tank nipple, tank adaptor, union etc complete fitting all as specified and as directed.
140Cleaning of PVC tank with bleaching powder and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity exc 250 but n.exc 500 ltrand painting the date of cleaning.
141Cleaning of PVC tank with bleaching powder and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity exc 500 ltr but n.exc 1000 ltr and painting the date of cleaning.
142Cleaning of PVC tank with bleaching powder and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity exc 1000 ltr but n.exc 2000 ltrand painting the date of cleaning.
143Preparing the surface by removing the spalled and loose plaster from existing surface and making it sound and clean by removing all dust particle and washing the surface with jet water. Then allowing the surface to dry and check for any cracks, honeycombing and other foreign particle complete as directed by site engineer
144Supplying, providing, mixing and laying over the prepared surface with cement mortar of average 15 mm thick or as per requirements in proportion 1:3 (1 Cement : 3 Sand) mixed with bonding agent, Nitobond SBR latex @ 5 litre per 50 Kgs of cement and integral waterproofing admixture Conplast WL of Fosroc Chemicals @ 125 ml per 50 Kg of cement complete as specified and directed by the Department.
145M & L for painting of old painted Surfaces of any description, over 10cm in width or girth, not otherwise described priming with red oxide zinc chrome and two coat of synthetic enamel paint all as specified and directed by Engineer-in-Charge
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail