Tender For Repair Maint Of Ceiling Fan Exhaust Fan With Connected Accessories Including Misc Em Services In High Rise Building At Rs Colaba And Repair Maintenance And Servicing Of Dg Sets Amf Panel Earthing Pits Standby Ug Cable Of Lifts And Other Co, mumbai-Maharashtra

Military Engineer Services-MES has published Tender For Repair Maint Of Ceiling Fan Exhaust Fan With Connected Accessories Including Misc Em Services In High Rise Building At Rs Colaba And Repair Maintenance And Servicing Of Dg Sets Amf Panel Earthing Pits Standby Ug Cable Of Lifts And Other Co. Submission Date for this Tender is 12-07-2023. Ceiling Fan Tenders in mumbai Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

38060178
Corrigendum : Tender For Repair Maint Of Ceiling Fan Exhaust Fan With Connected Accessories Including Misc Em Services In High Rise Building At Rs Colaba And Repair Maintenance And Servicing Of Dg Sets Amf Panel Earthing Pits Standby Ug Cable Of Lifts And Other Co
Open Tender
Indian
Maharashtra
mumbai
12-07-2023

Tender Details

Repair Maint Of Ceiling Fan Exhaust Fan With Connected Accessories Including Misc Em Services In High Rise Building At Rs Colaba And Repair Maintenance And Servicing Of Dg Sets Amf Panel Earthing Pits Standby Ug Cable Of Lifts And Other Connected Wor

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-07-2023

Key Value

Document Fees
INR 1000 /-
EMD
INR 160000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR/MAINT OF CEILING FAN, EXHAUST FAN WITH CONNECTED ACCESSORIES INCLUDING MISC E/M SERVICES IN HIGH RISE BUILDING AT RS COLABA AND REPAIR, MAINTENANCE AND SERVICING OF DG SETS, AMF PANEL, EARTHING PITS, STANDBY UG CABLE OF LIFTS AND OTHER CONNECTED WORKS OF GE (NW) NAVY NAGAR, COLABA, MUMBAI.
Sl. No. Item Description
1Taking down ceiling fans of 1200/1400mm sweep from site for repair complete all as specified and directed by Engr-in-Charge.
2Rewinding of ceiling fan/wall mounted fan/pedastal fan any size as per IS-13730 using super enameled copper wire of same guage complete and directed. Note:Canopy, bushes, bearing, capand fan blade measured and paid separately.
3Overhauling of ceiling fan any size and Make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust rust and assembling and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076, including replacement of canopy, bushes, bearing, cap and fan blade with new and testing after refixing at site complete all as specified and as directed by Engr-in-Charge.Note:Canopy, bushes, bearing, capand fan blade measured and paid separately.
4Supply only ceiling fan canopy suitable for 15mm dia rod with fixing Nuts and Bolts as approved by Engr-in-Charge
5Supply only gun metal bush suitable for any sweep fan of any make
6Supply only capacitor 2.5Mfd.Make : USHA /ASIAN/EPCOS
7Supply only ball bearing suitable for 1200/1400mm sweep Ceiling fan. Make : TATA/NBC/SKF
8Supply and Fix and replacement of15mm dia MS clamp assembly with Nut, Bolts & rubber bush suitable for down rods and split pins including taking out old oneas approved by Engr-in-Charge
9Supply and fixing in repair ceiling fan down rod of length 300/450 mm, inner diameter 15mm and thickness not less than 1.5mm with clamps Nuts, Bolts and washers for existing ceiling fan as approved by Engr-in-Charge
10Supply only ceiling fan GI blade suitable to any sweep and makes complete all as specified and as directed. Make : USHA/Kaitan/CG
11M & L for fabrication of fan hook made out ofSS rod and fan Hook bend to shape "S" after taking out old one.
12M & L for preparing ceiling fan surfaces for painting by removing/cleaning dust and deposited material and applying two coats of white enamelled paint by spray to fan blades, body and down rod, canopy of ceiling fans complete all as specified and as directed
13Taking out unserviceable ceiling fan and deposit to MES Store, supply and replacement with ceiling fan 230V, 50 Hz, AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as sepecified. Model : Orient/Usha/Crompton/Havells/Bajaj/Polycab
14Taking down Exhaust fan of any sweep for repairscomplete all as specified and directed by Engr-in-Charge
15Overhauling of Exhaust fan any size and Make, dismantling parts, properly cleaning/removing old existing grease, oil and applying new oil grease, varnishing for winding, cleaning dust, rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover etcand reassembling, connecting with copper conductor multi stranded 3 core wire of size 14/0.0076 complete and testing after refixing at site. Note: Rate of petty items to be replace shall be included in quoted rate.
16Taking down deteriorted louvers and Supplying and fixing new louversmade out of 16SWG GI sheet with machine pressed cut for horizontal ventilation at any height up to (G+14 floor) suitable for 300mm sweep exhaust fan complete all as specified and as directed by Engr-in-Charge.” Note :- Neccessary scaffolding, Safety belt, and netfor G+14 high rise buildings shall be provided by the contractor and cost of the same are deemed in quoted rate.
17M & L for rewinding of exhaust fan with superenamelled copper wire of same size/gauge, no of turns as per existing, varnishing, oiling and greasing of any make of size 230/300/380mm sweep by dismantling its parts andreplacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover andcleaning of exhaust fan body and its blade by cleaning agent, assembling, and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076, and testing after refixing at site. Note: Rate of petty items to be replace shall be included in quoted rate.
18All as per Item No 17.00 above butof size 450mm sweep.
19S & F Exhaust GI fan blade suitable to any sweep exhaust fan and makes complete after taking out old one all as specified and as directed by Engr-in-charge.Make : USHA/Kaitahn/CG
20M&L for preparing exhaust fan of any size surfaces for painting by removing/cleaning dust and deposited material and applying two coats of grey enamelled paint by spray to Exhaust fan body, blades and louvers complete all as specified and as directed by Engr-in-Charge
21Cutting hole in existing concrete or brick wall suitable for fixing 230/300/450mm sweep exhaust fan making good the hole including proper internal plaster work and surface finish in side and outside the hole as per site requirement complete all as specified and directed by Engr-in-Charge
22Taking out unserviceable Exhaust Fan and Supply and fix Exhaust fan, 4 blade, heavy duty, double ball bearing, 230V, 50Hz,300mm sweep having power input 70W speed 1440RPM including connection as required at site with flexible copper cable all as per specified and directed. Make :- Havells/CG/Almonard.Note : Old unserviceable exhaust fan will be deposited in MES store.
23Inspection/ checking of serviceability for ceiling fan to avoid any accident on site a job shall be done as taking down ceiling fan from its position, checking and replacement of minor unserviceable and minor defective spare parts responsible for any accident (i.e. "S" hooks, split pin, cotter pins, rubber bush etc) servicing the fan completely after removing of old grease from bearings and compulsury fixing of safety wire (SWR with self locking nut and screws) from fan motor to Ceiling hook incl hanging it to its same location after complete assurence of any defect and connecting with copper conductor multi stranded 3 core wire of size 0.75 sqmm complete all as specified and as directed by Engr-in-Charge.
24Note 1. : Complaint pertains to unserviceable ceiling fan/Exhaust Fan as given by the Engr-in-Chargeshall be attended within 48hrs from the day of complaint assigned to the representative of the firm as directed by Engr-in-Charge upto the satisfactory level and on failing which the penality shall be imposed @ Rs 250/- per day per item of Schedule.
25Note 2. : The Contractor or the accredited representative of the firm shall report to the JE concerned at the E/M Complaint Cell i.e Sub Station RS-1 Colaba resp for receiving the complaints at 0900 to 1000hrs daily excluding Sunday and Holiday
26Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/ pointscomplete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
27Material and labour for point wiring complete with proper colour coding using, 1100 volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor conforming to IS-694, part-II, ISI marked and including PVC casing and caping not less than 25 mm size, ISI mark with all accessories on wall/ceiling/floor/roof etc, including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following :- NOTE :Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm.
28One light/Exhaust/Ceiling fan point controlled by one switch.
29One 3 pin socket outlet, 5 Amps on the same board with other switches
30One 3 pin socket outlet, 5 Amps, on the independent board
31One bell point controlled by one push button
32All as per item No 25.00above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch.
33S & F in replacement with modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
34S & F in replacement with modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
35S & F in replacement with modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
36S & F in replacement with modular socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
37S & F in replacement with modular stepped type fan regulator, 2 module, single pole one way ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
38S & F in replacement with modular bell push switch, 1 module, single pole one way 6Amp ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
39Supply & Fixing Retrofit LED lamp 7 Watts complete all as specified and directed.
40Supply & Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
41Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F in replacement with modular PVC Gangbox of 12 module, ISI marked for mounting of modular switches and sockets including blank plate for blank module. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
42All as per Item No- 35.00 above but of modular PVC Gangbox, 8 module.
43All as per Item No- 35.00 above but of modular PVC Gangbox, 6 module.
44All as per Item No- 35.00 above but of modular PVC Gangbox, 4 module.
45All as per Item No- 35.00 above but of modular PVC Gangbox, 3 module.
46All as per Item No- 35.00 above but of modular PVC Gangbox, 1/2 module.
47S&F modular white cover plate with frame, 12 module.
48S&F modular white cover plate with frame, 8 module.
49S&F modular white cover plate with frame, 6 module.
50S&F modular white cover plate with frame, 4 module.
51S&F modular white cover plate with frame, 3 module.
52S&F modular white cover plate with frame, 1/2 module.
53Taking down unserviceable FTL/batten fittings with supply and fix LED batten fitting 20 Watt, 240V, 4ft CDL/NW comprises of extruded channel in thermally conductive material with decorative end cap and high translucent serration milky white diffuser of high optically efficient plastic FR grade. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose. The contractor shall provide test certificate from authorized lab. Make of Light Fitting :Wipro/Crompton/Philips/Bajaj/Polycab
54S&F MCB DB SPN conforming to as per IEC 61439-3 and IP 43, IK 09 with acrylic door,8 waycomplete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces by plastering or PCC work inclding distembering to the affetced to walls. Make : Legrand/Havells/Siemens/L&T
55Taking out Old U/S and S&F MCB SPN, 32 Amp, 10 KA, 230 Volt. Make : Legrand/Havells/Siemens/L&T
56Taking out Old U/S and S&F MCB, single pole, upto 20 Amp, 10 KA, 230 Volt. Make : Legrand/Havells/Siemens/L&T
57S & F in replacement with Analog time switch 3P Module, 24 hours program, programmable every 15 min., backup of 100 hours, current capacity 16A for ON/OFF controlling of security lights complete all as directed.
58S & F in replacement with power contactor 3 pole AC, with 240 volt coil, 32 Amp ratingconforms to IS / IEC 60947-4-1 for ON/OFF controlling of security lights complete all as directed.
59Supply and fixing of MCCB DB VTPN 8 way as per IEC 61439-3 Suitable for Flush /Surface mounting with 250 A Copper Busbar for each phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management fully insulated busbar & shrouded Neutral bars improved Pan assembly for ease of installation prefitted masking sheet reversible metalic door for IP 43 & IP 54 DB"s with provision for 100 Amp 4pole MCCB as incomer and SP/TP MCB"s as outgoing complele all as specified and directed. Make : Legrand/Siemens/Schneider/ABB
60Supply and fixing of MCCB 100A, 25kA, 4P, Thermal magnetic release , Ics=100% Icu . Make : Legrand/Siemens/Schneider/ABB
61Supply and fix MCB TP 63A, 10kA, 415V. Make : Legrand/Siemens/Schneider/ABB
62Supply and fix MCB SP 63A, 10kA, 240V. Make : Legrand/Siemens/Schneider/ABB
63S & F in replacement with ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm.
64S & F in replacement with electric bell ding dong, AC, 230V single pole.
65M & L for earthing complete with Galvanised steel earth plate eletrode 60cmx60cmx6mm thick buried directly in ground vertically to (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised Iron Strip of size 32x6mm size, by means of Bolts, Nuts, Check Nuts and washer made of GI or Steel Earth connecting with test point, provision of Charcal and salt in alternate layers, watering pipe 20mm dia medium grade MS funnel with jali, PCC M-15 Type B-1 in pit with XPM not elss than 4Kg per Sqm and Earthpit with cover returning, filling, removing excavated material all as specified in electrical plate No 3 of SSR Part-I making good excavated surfaces such as hard standing refixing machine pressed precast concrete interlocking paver blocks removed during excavation on earthpit to mach existing surfaces after taking out old/unserviceable one complete and testing on completion all as specified and directed by Engr-in-Charge
66M&L for carrying out B check including periodic maintenance & servicing prescribed by the manufacturer of the DG Set from authorized rep of service engineer from the manufacturer of the DG Set of Greaves/Cummins/Kirloskar 100/125/140/160/ 200 KVA capacity installed at R-29 Bldg, Near Tula Bldg, R-12 Bldg, Mithun Bldg, Mulla Auditorium including replacement of engine oil, coolant and replacement of following unserviceable spares complete all as specified and directed by EIC. Note: Spares will be measured & paid separately under respective items here in after.
67Supply only in replacement Diesel fitter as per existing make and model.
68Supply only in replacement Lub oil filter as per existing make and model..
69Supply only in replacement Air filter element as per existing make and model.
70Supply only in replacement Fan belt as per existing make and model.
71Supply only in replacement Carbon bush as per existing make and model.
72Supply only in replacement high pressure oil pipe as per existing make and model.
73Supply only in replacement Lub oil pipe as per existing make and model.
74Supply only in replacement Radiator hose pipe set as per existing make and model.
75Supply only in replacement LLOP Sensor as per existing make and model.
76Supply only in replacement of coupling flanged type as per existing make and model.
77Preventive maintenance and servicing of DG sets 100/125/140/160/ 200 KVA capacities installed at different location at Navy Nagar complete all as directed. The daily maint shall be carried out as under: (i) Cleaning of DG set floor and area (ii) Checking levels of Fuel/Engine Oil/Coolant and top-up the level if required (iii) Checking of Batteries, flexible coupling, injectors, thermostats, monitoring functions, compression, turbo charger clearance of bearings, air and water hoses, Zinc protective pipes, coupling disc of fuel pump drive, "V" Belts (iv) Checking tightening of all nuts and bolts. (v) Checking levels of distilled water in batteries and top-up the level if required. (vi) Checking levels of distilled water in batteries and top-up the level if required. (vii) Cleaning of air filters (viii) Lubricating/Greasing to moving parts (ix) Checking and reset valve clearances. (x) Checking and setting of speed Governor and engine shut down for proper functioning (xi) Checking of carbon bushes of generator and lubricate the bearings (xii) Cleaning of Crankcase ventilation, cooling water spaces, inter cooler (xiii) Checking of replacing carbon bushes and starter pinion
78(xiv) Checking and monitoring of DG set running in condition by switching on mannual position on without load not less than 15 minute twice in week for each DG set and maintaining their running record in Log sheet/PRRB. If any shortcomings found in any DG set, immediately rerport to JE concern as well as to the contractor.Schedule of running for each DG set shall be decided by the Engr-in-Charge. Note : - (a) Spare parts shall be measured and paid separately. (b) Oil, Coolant and distril water will be measured and paid saparately. (c) Complaint pertains to DG Set of the sch A as given by Engr-in-Charge at any time shall be attend within 12 Hour from the time of complaint assined to the representative of the firm as directed by Engr-in-Charge up to the satisfactory level and on failing which the penalty shall be imposed 2500 per day per item / complaint of schedule "A". (d)OneSkilled Technician forDG Set will be Report to JE concern at RS - I Sub station. Tech staff will remain present from 0900 to 0430 Hrs daily excluding Sunday and Holiday.
79M & L for replacement of old engine oil from the sump of DG Setsinstalled at various locations after cleaning the oil sump throughly supply & filling new Lub oil, SAE 15W40 grade complete all as specified & directed by Engineer-In-Charge. Make : Servo super of Indian Oil or Equilent grade of Hindustan Petrolium.
80S&F in replacement ofFuel Pre Filter Suitable for Diesel Engine, TBD 3V 6MK-1/TBD 2V6/TBD 2V 6MK-1/TDL4L. Make : Greaves Ltd.and all as specified and directed by Engineer-In-Charge.Male/Botch/Greaves
81M & L for topping up of water coolent in radiator of DG sets tinstalled at variouslocations complete all as specified & directed. Make : TVS Girling/volvo line or of equivelent make all as approved & directed by EIC.
82M & L for dismantaling of FIP for overhauling and caliberation in authorised workshop including replacement of wornout rings plungers, damper plate, gasket etc and reassembling testing complete for DG sets of capacity 100 KVA to 140 KVAcomplete all as specified & directed.
83All as per Item No 65.00 above but DG sets capacity 160 KVA to 200 KVA
84M & L for repair overhauling of self starter including replacement of worn out clutch assembly bush, spring, plunger assembly, solenoid switch, corbon brushes, spring etc for DG sets of capacity 100 KVA to 140 KVAcomplete all as specified & directed.
85All as per Item No 67.00 above but DG sets capacity 160 KVA to 200 KVA
86Repair/overhaling of dynamo/charging alternator including replacement carbon, brushes holder, spring commutator/slipring assembly bearing regulator its of any make, type and capacity, complete all as directed.
87Cleaning of the fuel tank of DG sets of of capacity 100 KVA to 140 KVA after decaning the diesel, after throughly cleaning with kerosene oil including replacement of level indicator pipe complete all as directed by EIC.
88All as per Item No 70.00 above but DG sets capacity 160 KVA to 200 KVA
89M & L for dismantling and removing of water pump assessmbly complete from the engine repair/overhauling the same by replacing worn components like bearing, impeller, bushes, oil seal, water seal, gaskit etc. reassembling, refixing and testing complete for DG sets of capacity 100 KVA to 140 KVAcomplete all as specified & directed.
90All as per Item No 72.00 above but DG sets capacity 160 KVA to 200 KVA
91M & L for Automatic voltage regulator suitable for DG set of capacity 100 KVA to 140 KVA as per existing Make & model and as directed by EIC.
92All as per Item No 74.00 above but DG sets capacity 160 KVA to 200 KVA
93M & L for replacement of fuel shutdown valve assembly complete testing including replacement of old unsv valves of any capacity DG set, complete all as directed by EIC .
94M & L for replacement of bendix drive pinon assembly of self starter of capacity 100 KVA to 200 KVA DG set complete all as specified & directed .
95M & L for replacement of existing make and model fly wheel ring including heating for press fitting for engine of DG sets of capacity 100 KVA to 140 KVAcomplete all as specified & directed.
96All as per Item No 78.00 above but DG sets capacity 160 KVA to 200 KVA
97M & L for replacement of stop solonoid assembly for DG sets of capacity 100 KVA to 140 KVAcomplete all as specified & directed.
98All as per Item No 80.00 above but DG sets capacity 160 KVA to 200 KVA
99M & L for Dismantling of radiator of DG set of capacity 100 KVA to 140 KVA and transporting to work shop for servicing/cleaning after dismantling twin tanks, replacement of gasket packing, nuts, bolts, washers, descaling with appropriate chemical and elding of copper brazing of damazed fins/tubes and reassembling & refixing in same position after testing complete all as specified & directed.
100All as per Item No 82.00 above but DG sets capacity 160 KVA to 200 KVA
101S&F Tacheometer/speedometer incl dismantling the existing meter suitable for kirloskar and cummins Engine all as directed.
102Supply only ammeter 0 to 300 Amp range 96 x 96 mm flush type 3 Phase 415 Volts AC with CTs Ratio 100/5 A in all Three phases with 4P selector switch to read current in all three phases including dismantling old ammeter.
103Supply only Voltmeter 0 to 500 Volts AC including dismantling old voltmeter with 4P selector switch to read 3 Phase voltage.
104M&L for scraping the peeled oil Paint on 200/160/140/100 KVA DG set including alternator,Engine and Fuel tank,sound proof cover Preparing the surfaces, cleaning the dust, dirt and applying two coats of synthetic enamel paint of approved shade and writing SM No on the DG set and all as directed by Engineer-In-charge.
105M & L for repairing of comlete GENSET engine wiring including extesion of existing PVC insulated , stranderd copper conductor wire of size 2.5 sq mm /1.5 sq mm for control/ signal circuit complete with & including flexible conduit, copper lugs, PVC ties, fasteners & synchronisation and calliberation of AMF panel with engine control panel complete all as specified & directed .
106M & L for General servicing/repair of AMF panel including cleaning, resetting/adjustment of relays of timer relay,overload relay, auto start/stop relay its checking and replacement if required wire,diodes resistor etccomplete for existing make and capacity
107M & L for replacement of SMPS based Electronic Battery Charger suitable for 12 / 24 Volts battery charging system complete all as specified & directed.
108M & L for replacement of contactor 4 pole, not less than 300 Amp, 415 Volt with integrated auxiliary contacts : 2 NO + 2 NC conforming to IS / IEC 60947-4-1 and compitable with existing AMF panel complete all as specified and directed. Make- L&T, Type-MCX-41, cart part No.CS97023 or equivalent model of Legrand/Siemens.
109M & L for replacement of contactor 4 pole, not less than 250 Amp, 415 Volt with integrated auxiliary contacts : 2 NO + 2 NC conforming to IS / IEC 60947-4-1 and compitable with existing AMF panel complete all as specified and directed. Make- L&T, Type-MCX-34, cart part No.CS97022 or equivalent model of Legrand/Siemens.
110M & L for replacement of contactor 4 pole, not less than 200 Amp, 415 Volt with integrated auxiliary contacts : 2 NO + 2 NC conforming to IS / IEC 60947-4-1 and compitable with existing AMF panel complete all as specified and directed. Make- L&T, Type-MCX-33, cart part No.CS97021 or equivalent model of Legrand/Siemens.
111M & L for replacement of spare coil for existing contractor fitted in AMF panel of any capacity & type complete all as specified. Make:- L&T/Legrand/Siemens.
112M & L for replacement of engine start relay 12/24 Volts compitable with existing AMF panel complete all as specified. Make:- PIC /Technica/Indo.
113M & L for replacement of over and under voltage relay 3 phase 415 Volts compitable with existing AMF panel complete all as specified. Make:- PIC / Minilec/ L&T.
114M & L for replacement of Auxiliary relay 8 pin /11 pin compitable with existing AMF panel complete all as specified. Make:- PLA /L&T( Slazer)/Schneider.
115M & L for replacement of timer switch AC/DC compitable with existing AMF panel complete all as specified. Make:- PIC/MINUTE.
116S&F in replacement with newExhaust silencer suitable for Diesel Engine,Model No.TBD 3V 6MK-1/Model No.TBD 2V6/ Model No.TDL4LModel No.TBD 2V 6MK-1. Make : Greaves Ltd.and all as specified and directed by Engineer-In-Charge.
117M & L for replacement of ON Load change over switch 4 Pole, 415 Volt, in sheet steel enclosure of capacity 200 Amps complete all as specified & directed. Make-L&T/Schneider
118Supply and fixing in replacement of Asbestos Rope DG Rating 140KVA to 200KVAand all as specified and directed.
119M & L for replacement of battery terminals brass with steel nuts, bolts & washers and all as directed.
120M & L for replacement of battery lead standred copper conductor of size 50 Sq mm and all as directed.
121M&L for filling / pouring distill water packed in 20 / 25/ 35 litre PVC containers & top up of electrolite for servicing of battery complete all as specified & directed .
122Supply and installation of maintenance free battery lead acid type of capacity 12 Volt 180 AHforDG Setsinstalled at various locations Complete all as specified & directed by Engineer-in-charge. (Make Excide express/ Amron/ Microtek)
123Taking down old existing unserviceable AMF panel of DG set and supply, install, testing and commissioning ofnew AMF panel for DG Set of Capacity 100 to 250 KVA3 phase, 4 wire, 415 volts, with copper busbar strip of suitable capacity with necessary clamps, nuts, bolts and washers, floor mounted type and made with angle iron 40x40x5 mm thick, legs of size not less than 0.60 Mtr Long from floor level and painted with two coats of red oxide primerincl foundation in PCC including multi function meter with LED display with CT"s, LED indicator lamp all as specified & directed. Note : All existing cable connections will be disconnected from old panel carefully and re-connected with new panel by providing glands and thimble all as directed by Engineer-in-Charge.
124M & L for 80 mmdia M S Pipes heavy grade for fixed on ground/floors to used as post/structure for shed including fabrication work like welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
125Same as Item No 107.00 above but 40 mm diaM S Pipes heavy grade.
126M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed.
127M & L for Pre- painted galvalume aluminum zinc coating GI based corrugated sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
128Supply, Fixing, testing and commissioningofXLPE insulated armoured, heavy duty electric cable with aluminium conductorlaid in trenches, fixed on wall, passing through pipes complete including connecting with MCCB/ busbar with the help of proper size thimble, glands,properly as directed by engineer-in-charge and taking out existing damaged unserviceable cable of following sizes:- Note : Excavation, earthwork and cable protection shall be measured and paid separately under relevant items.
129Same as Item No 111.00 above but size 300 Sq mm, 3.5 core
130Same as Item No 111.00 above but size 185 Sq mm, 3.5 core
131Same as Item No 111.00 above but size 120 Sq mm, 3.5 core
132Same as Item No 111.00 above but size 95 Sq mm, 3.5 core
133Same as Item No 111.00 above but size 70 Sq mm, 3.5 core
134Same as Item No 111.00 above but size 35 Sq mm, 3.5 core
135Same as Item No 111.00 above but size 25 Sq mm, 3.5 core
136Same as Item No 111.00 above but size 16 Sq mm, 4 core
137Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables .
138Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils.
139Removing excavated material from the site of work to outside MD land complete all as specified.
140Supply, filling, spreading levelling and well ramming the river sand around cable in trenches for cable cushioning all as specified and directed.Note : Punned thickness shall be measured and paid.
141Supply and laying un-reinforced pecast concete cable covers class LV, Type 1, flat, size 250mmx 150mm x 40mm all as specified and directed.
142Cutting existing road surface or hard standing, bituminous topping 15 cm but n exc 30cm girth for laying of pipes/ cables and making good distrubed surface to match with existing complete.
143M & L for cement concrete 1:4:8 type D2 (using 40mm grade stone aggregate) as in foundations, filling and mass concrete finished fair and even comlpete all as specified
144M&L for GI pipe ,light grade 50mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed.
145M&L for GI pipe ,light grade 80mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed.
146M&L for GI pipe, light grade 100mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
147M & L for fixing of old interlocking paver tiles/blocks of any sizes recovered form item SI. No. 125 including laying over 50 mm thick sand bed compacted complete as specified and directed.
148M & L for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of existing size and existing type and including laying over 50 mm thick sand bed compacted complete as specified and directed.
149M&L for High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 40mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
150M&L for High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 75mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
151M&L for High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 100/110mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
152Material and labour for maintainance free environment friendly earth electrode set comprising of 17.2mm dia, 3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) after taking out old, U/S one complete all as directed by Engineer-in-Charge. Make- JEF Ecosafe or equivalent as approved by GE.
153M&L for taking out existing Panel andshifting of LT panel of any sizewith all accessories and fixing it to other location as directed by Engr-in-Charge at site, connecting cable connection with connecting accessories, incl foundation in PCC 1:3:6 type C2 all as specified and directed.
154Material & Labourfor repairs/Servicing to ExistingLT electric panels or AMF Indoor type of each Gen setincluding checking loose connections and tight connection and cleaning inside/out side all connection,replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors, providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge all as directd and specified. (Note: The tenders quoted rate per unit shall deemed to be inclusive of taking out burnt MCB/MCCB/Voltmeter/Ampiermeter /CT/LED lamps of any type and discription etc and refixing the same, which shall be measured and paid as supply only vide relivent items of this schedule.)
155Cleaning inside the panel and all incoming and out going feedersi.eincludinging MCCB/Changeover switches/Contactors thorouly with help of Vaccum Cleaner.
156Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers
157Replacing the burnt out color coated PVC Sleeve of main and fedders bus bar with appropriated size of New PVC heat shrinkable sleeves
158Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/HRC Fuses.(Note: New items shall be measured and paid separatly)
159Replacing burnt out control wiring of Ammeter/Voltmeter/Indicating lamps and CT"swith 2.5/1.5Sqmm copper single core,1100V grade copper conductor cable
160Replacing Burnt out Bus Bar of incomming and out going feededs with approprieted size of new bus bar ( Note : Bus Bar will measured and paid separately).
161Spray Painting of Panel Board with one coat of synthetic enamel paint.
162S&F Copper Bus Bar stips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed. Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account. (d) Rate of Bolts, Nuts etc shall be included in quoted rate.
163S&F of suitable type and size FRP / DMC bus bar support insulator (Bridge Insulator) for fixing the extended aluminium/copper bars, for cable terminations, duly fixed in the body of the panel boardincluding galvanized steel bolts, nuts, washers etc.and necessary drillings, in the panel body,complete all as specified and as directed.
164Material and labour for fault finding on LT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
165Supply and fix cable jointing kitStraight Through Jointfor 1.1KV grade cable complete with Jointing material (Heat shrinkable) and accessories suitable for 3.5core XLPE armoured, alluminum conductor cable of size 25 to 95 sq mm after taking out and cutting the faulty cable area, inserting 1 mtr Cable of existing size for jointing Cables if required at site and all as directed by Engineer-In-Charge. Make- Denson/3M/M-Seal
166All as per Item No 141.00 above but for 3.5core XLPE armoured, alluminum conductor cable of size 120 to 185 sq mm and all as directed by Engineer-In-Charge. Make- Denson/3M/M-Seal
167All as per Item No 141.00 above but for 3.5core XLPE armoured, alluminum conductor cable of size 240 to 300 sq mm and all as directed by Engineer-In-Charge. Make- Denson/3M/M-Seal
168Supply only, MCCBsthermal magnetic release,lcs=100% lcu in existing FP/panel, connecting to bus-bar with all connecting accessories and modification in busbar (if Necessary), connection complete and testting after complition, all as specified and directed,of following capacities.
169MCCB 63/100 Amps,16 kA,FP, 50 Hz.
170MCCB 160 Amps,25 kA,FP,50 Hz.
171MCCB 200 Amps,25 kA,FP,50 Hz.
172MCCB 250 Amps,25 kA,FP,50 Hz.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail