Tender For 8736 Repair, Maintenance Of Servo Voltage Stabilizers, Isolation Transformers, Apfc Panels And Other Miscellaneous Items Under Ge (Af) Bareilly, bareilly-Uttar Pradesh

Military Engineer Services-MES has published Tender For 8736 Repair, Maintenance Of Servo Voltage Stabilizers, Isolation Transformers, Apfc Panels And Other Miscellaneous Items Under Ge (Af) Bareilly. Submission Date for this Tender is 03-07-2023. Voltage Stabiliser Tenders in bareilly Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38059582
Corrigendum : Tender For 8736 Repair, Maintenance Of Servo Voltage Stabilizers, Isolation Transformers, Apfc Panels And Other Miscellaneous Items Under Ge (Af) Bareilly
Open Tender
Indian
Uttar Pradesh
bareilly
03-07-2023

Tender Details

8736 Repair, Maintenance Of Servo Voltage Stabilizers, Isolation Transformers, Apfc Panels And Other Miscellaneous Items Under Ge (Af) Bareilly

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Jun-2023 Corrigendum No. 1 BOQ 26-06-2023
2 26-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 39000.0 /-
Tender Value
INR 19.50 Lakhs /-

BOQ Items

Name of Work: REPAIR/ MAINTENANCE OF SERVO VOLTAGE STABILIZERS, ISOLATION TRANSFORMERS, APFC PANELS AND OTHER MISCELLANEOUS ITEMS UNDER GE (AF) BAREILLY
Sl. No. Item Description
1Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 400 KVA, 3 phase, 50 c/s, AC supply of Make- Vintec/ Blue Line or Indian transformer & Electricals and overhauling of the same by cleaning, servicing all serviceable accessories including repairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at site with and including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed. NOTE: - Supply only spare parts shall be measured and paid separately under relevant items of this schedule.
2Supply only following spare parts of 400 KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - (a) AC synchronous motor single phase, 50 Hz, 240 volts Make- UNI STEP.
3(b) Variable auto transformer (Variac).
4(c) Sensing Transformer.
5(d) Carbon brush with holder complete.
6(e) Solid state sensing circuit.
7(f) RC Net work.
8(g) PCB connector.
9(h) Gear big.
10(j) Carbon fingers.
11(k) Variac Control CT.
12(m) Main Bushing with brass rod (insulator & rod).
13(n) High low cut off relay.
14(p) Series transformer.
15(q) Wiring Set.
16(p) Gear small.
17Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 300-320 KVA, 3 phase, 50 c/s, AC supply of Make- Vintec/ Blue Line or Indian transformer & Electricals and overhauling of the same by cleaning, servicing all serviceable accessories including repairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at site with and including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed. NOTE: - Supply only spare parts shall be measured and paid separately under relevant items of this schedule.
18Supply only following spare parts of 300 to 320 KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - (a) AC synchronous motor single phase, 50 Hz, 240 volts Make- UNI STEP.
19(b) Variable auto transformer (Variac).
20(c) Sensing Transformer.
21(d) Carbon brush with holder complete.
22(e) Solid state sensing circuit.
23(f) RC Net work.
24(g) PCB connector.
25(h) Gear big.
26(j) Carbon fingers.
27(k) Variac Control CT.
28(m) Main Bushing with brass rod (insulator & rod).
29(n) High low cut off relay.
30(p) Series transformer.
31(q) Wiring Set.
32(p) Gear small.
33Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 200-250 KVA, 3 phase, 50 c/s, AC supply of Make- Vintec/ Blue Line or Indian transformer & Electricals and overhauling of the same by cleaning, servicing all serviceable accessories including repairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at site with and including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed. NOTE: - Supply only spare parts shall be measured and paid separately under relevant items of this schedule.
34Supply only following spare parts of 200 to 250 KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - (a) AC synchronous motor single phase, 50 Hz, 240 volts Make- UNI STEP.
35(b) Variable auto transformer (Variac).
36(c) Sensing Transformer.
37(d) Carbon brush with holder complete.
38(e) Solid state sensing circuit.
39(f) RC Net work.
40(g) PCB connector.
41(h) Gear big.
42(j) Carbon fingers.
43(k) Variac Control CT.
44(m) Main Bushing with brass rod (insulator & rod).
45(n) High low cut off relay.
46(p) Series transformer.
47(q) Wiring Set.
48(r) Gear small.
49Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 100-125 KVA, 3 phase, 50 c/s, AC supply of Make- Vintec/ Blue Line or Indian transformer & Electricals and overhauling of the same by cleaning, servicing all serviceable accessories including repairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at site with and including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed. NOTE: - Supply only spare parts shall be measured and paid separately under relevant items of this schedule.
50Supply only following spare parts of 100 to 125 KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - (a) AC synchronous motor single phase, 50 Hz, 240 volts Make- UNI STEP.
51(b) Variable auto transformer (Variac).
52(c) Sensing Transformer.
53(d) Carbon brush with holder complete.
54(e) Solid state sensing circuit.
55(f) RC Net work.
56(g) PCB connector.
57(h) Gear big.
58(j) Carbon fingers.
59(k) Variac Control CT.
60(m) Main Bushing with brass rod (insulator & rod).
61(n) High low cut off relay.
62(p) Series transformer.
63(q) Wiring Set.
64(r) Gear small.
65Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 50-75 KVA, 3 phase, 50 c/s, AC supply of Make- Vintec/ Blue Line or Indian transformer & Electricals and overhauling of the same by cleaning, servicing all serviceable accessories including repairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at site with and including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed. NOTE: - Supply only spare parts shall be measured and paid separately under relevant items of this schedule.
66Supply only following spare parts of 50 to 75 KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - (a) AC synchronous motor single phase, 50 Hz, 240 volts Make- UNI STEP.
67(b) Variable auto transformer (Variac).
68(c) Sensing Transformer.
69(d) Carbon brush with holder complete.
70(e) Solid state sensing circuit.
71(f) RC Net work.
72(g) PCB connector.
73(h) Gear big.
74(j) Carbon fingers.
75(k) Variac Control CT.
76(m) Main Bushing with brass rod (insulator & rod).
77(n) High low cut off relay.
78(p) Series transformer.
79(q) Wiring Set.
80(r) Gear small.
81Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 25-40 KVA, 3 phase, 50 c/s, AC supply of Make- Vintec/ Blue Line or Indian transformer & Electricals and overhauling of the same by cleaning, servicing all serviceable accessories including repairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at site with and including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed. NOTE: - Supply only spare parts shall be measured and paid separately under relevant items of this schedule.
82Supply only following spare parts of 25 to 40 KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - (a) AC synchronous motor single phase, 50 Hz, 240 volts Make- UNI STEP.
83(b) Variable auto transformer (Variac).
84(c) Sensing Transformer.
85(d) Carbon brush with holder complete.
86(e) Solid state sensing circuit.
87(f) RC Net work.
88(g) PCB connector.
89(h) Gear big.
90(j) Carbon fingers.
91(k) Variac Control CT.
92(m) Main Bushing with brass rod (insulator & rod).
93(n) High low cut off relay.
94(p) Series transformer.
95(q) Wiring Set.
96(r) Gear small.
97Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 10-20 KVA, 3 phase, 50 c/s, AC supply of Make- Vintec/ Blue Line or Indian transformer & Electricals and overhauling of the same by cleaning, servicing all serviceable accessories including repairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at site with and including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed. NOTE: - Supply only spare parts shall be measured and paid separately under relevant items of this schedule.
98Supply only following spare parts of 10 to 20 KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - (a) AC synchronous motor single phase, 50 Hz, 240 volts Make- UNI STEP.
99(b) Variable auto transformer (Variac).
100(c) Sensing Transformer.
101(d) Carbon brush with holder complete.
102(e) Solid state sensing circuit.
103(f) RC Net work.
104(g) PCB connector.
105(h) Gear big.
106(j) Carbon fingers.
107(k) Variac Control CT.
108(m) Main Bushing with brass rod (insulator & rod).
109(n) High low cut off relay.
110(p) Series transformer.
111(q) Wiring Set.
112(r) Gear small.
113S&F of 15 to 20 mm thick Bakelite sheet of size up to 250 mm X 300 mm including necessary nut-bolts and cutting work for fixing of cable as required at site complete all as specified and directed.
114Supplying and topping up new filtered and tested (not less than 45 KV) transformer oil conforming to IS-33593 in servo stabilizers to the required level complete all as specified and directed.
115Supply and fixing of the following items of Servo Controlled Voltage Stabilizer of any capacity and type as in replacement: - (a) Thimble / lugs of size 16 Sq.mm to 50 Sq.mm.
116(b) Thimble / lugs of size 70 Sq.mm to 120 Sq.mm.
117(c) Thimble / lugs of size 150 Sq.mm to 240 Sq.mm.
118(d) Push switch (Voltage increase / decrease switch).
119(e) Voltmeter as per existing capacity, pattern and size.
120(f) Ampere Meter as per existing capacity, pattern and size.
121(g) Selector switch for Voltmeter as per existing capacity, pattern and size.
122(h) Selector switch for Ampere Meter as per existing capacity, pattern and size.
123(j) Limit switch.
124(k) CT of any ratio as per existing rating as required.
125Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked, LT cable of size 70 Sq.mm 3.5 core (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing and taking down old unserviceable cable complete all as specified and directed.
126All as per item No 18 hereinbefore but cross sectional area of cable 95 Sq.mm 3.5 core complete all as specified and directed.
127All as per item No 18 hereinbefore but cross sectional area of cable 150 Sq.mm 3.5 core complete all as specified and directed.
128All as per item No 18 hereinbefore but cross sectional area of cable 185 Sq.mm 3.5 core complete all as specified and directed.
129M&L for preparation of the steel surface of LT Panel, Feeder pillar box, Pole box, indoor or outdoor type including cleaning, scraping of exposed surfaces and painting with one coat of synthetic enamel paint with spray painting process in approved shade with and including writing MES number and machine number with black paint (Letter size 50 mm high and minimum 15 mm wide) complete all as specified and directed.
130S&F as in replacement 3.15 mm mild steel sheetas in door of electric panel, feeder pillar box by means of suitable electric welding complete all as specified and directed.
131M&L for preparation of old painted surface of steel tubular HT or LT electric pole any height including struts, cross arms, clamp and the like fitted on pole and applying one coat of aluminum paint and writing pole number in letter size not less than 50 mm with black synthetic enamel paint complete all as specified and directed.
132Repair/ maintenance of Isolation transformer of capacity 400 to 630 KVA, 3 phase, 50 Hz, AC Supply by cleaning servicing all serviceable accessories including repair/replacement of all defective parts such rewinding of copper coil,nut-bolt, washers and all other minor accessories as required at site with and including painting with two coats of synthetic enameled paint externally after rubbing providing lugs on existing cable and testing on full load after completion of repair work complete all as specified and directed .
133All as per item No 25 hereinbefore but of capacity 100 to 125 KVA complete all as specified and directed .
134Deduct: Amount of Schedule of Credit b/f from Sl. Page No. 17 of tender document i.e. Rs. 62193.00
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail