New Construction Of Gazipur Bazar Sulav Sauchagar Kulpi Gazipur Gazipur Under Kulpi Ps (2Nd Call Of Nit-41 Of 22-23 For Sl. 12
Tender Value
11.88 Lakhs
Estimated cost
Bid Submission
22 Jun 2023
0 days left
EMD
23765
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kulpi → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
New Construction Of Gazipur Bazar Sulav Sauchagar Kulpi Gazipur Gazipur Under Kulpi Ps ( 2Nd Call Of Nit-41 Of 22-23 For Sl. 12
BOQ
| Sl. No. | Item Description |
| 1 | Sulav Souchagar |
| 2 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. |
| 3 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation. |
| 4 | (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 5 | Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. |
| 6 | Ordinary cement concrete ( mix 1:2:4 ) with graded stone chips ( 20 mm. nominal size ) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. ( For PCC ) |
| 7 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor)25 mm 30 mm thick wooden shuttering. Foundation upto P.L. |
| 8 | In Gr. Floor |
| 9 | Ordinary cement concrete ( mix 1:1.5:3 ) with graded stone chips ( 20 mm. nominal size ) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. |
| 10 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary) cutting to requisite length, including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.II. ( JSW /JPSL/ SRMB / SHYAMETC) |
| 11 | Brick work with 1st class bricks in cement mortar( 1 :6) a) In foundation & plinth |
| 12 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 13 | Plaster (to wall, floor, cellingetc)withsand andcement mortarincludingrounding off or chamferingConrners asdirectedand raking outjointsincludingthroating, nosing and dripdourse, scffolding/staging where necessary (gorund floor) (excluding cost ofchippingoverconcretesurface)(i) With 1:6 cement mortar (c)15 mm thick plaster, Outside |
| 14 | (b)20 mm thick plaster, inside |
| 15 | (ii)With (1:4) cement mortar.(c)10 mm thick plaster, Celling |
| 16 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i)Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. ( F.F.) |
| 17 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) FloorWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(b) Area of each tile above 0.09 Sq.m(i) Coloured decorative |
| 18 | (B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(b) Area of each tile above 0.09 Sq.m(i) Coloured decorative |
| 19 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finishacrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. Two coat |
| 20 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor)i) Water based interior grade Acrylic Primer Two coat |
| 21 | Acrylic Distemperto interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface. Two Coats |
| 22 | Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost ofprimer. Two Coats In Ground floor |
| 23 | (b) Priming one coat on steel or other metal surface with synthetic oilbound primer of approved quality including smoothening surfaces bysand papering etc. (a) One coat in Ground Floor. |
| 24 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: |
| 25 | On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white) |
| 26 | Anodised aluminium barrel / tower / socket bolt (full covered)of approved manufactured from extruded section conformingto I.S. 204/74 fitted and fixed with cadmium plated screws: (iii) 100mm long x 10mm dia. bolt. |
| 27 | Supplying, Fitting & Fixing Factory made P.V.C. door frameof size 50 mmx47 mm with a wall thickness of 5 mm, madeout of extruded 5 mm, PVC sheet miter cut at two corners and joined with two nos of 1.5 mm long brackets of 15 mm x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19 mmx 19 mm M.S. Square tube of 19gauge, weather seal to be provided through out the frame. The door frame shall be fixed with the wall using 65/100 mmlong M.S. Screws through the frame by using P.V.C fasteners. A minimum of 4 Nos of screws to be provided for eachvertical member and minimum 2 Nos for horizontal member etc. complete as per Manufacturer’s specification anddirection of Engineer-in-Charge. |
| 28 | Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make ......................... shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th. both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channelusing PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge. In ground floor |
| 29 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugsset in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. |
| 30 | Sanitary & Plumbing : Supplying , fitting and fixing of UPVC pipes conforming to I.S. 13592 and UPVC fittings conforming to I.S. 13591 - 1992, including all necessary clips, lubricant and rubber gasket, etc makign holes in wall\"s floors, cutting conc. Structures if necessary and mend. |
| 31 | a)110 mm dia pipe |
| 32 | UPVC Fittings |
| 33 | a) Door Tee - 110 mm dia |
| 34 | b) Plane Bend - 110 mm dia |
| 35 | c) Vent Cowl - 110 mm dia |
| 36 | d) Pipe Clip - 110 mm dia |
| 37 | Supplying , fitting & fixing PVC Pipes of approved make of (medium duty) conforming to ASTMD-1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials Viz socket , band, bend, tee, union, cross, elbow, nipple, long screw, reducing socket, reducing tees, short piece etc. fitted with holder bats clamps, including |
| 38 | a)50 mm dia |
| 39 | b)32 mm dia |
| 40 | c)20 mm dia |
| 41 | Supplying, fitting and fixing with cement jointing (3:1) salt glazedstoneware pipe including excavation of earth upto 1.50 metre depth in allsorts of soil both mixed or unmixed and refilling (but excluding concretingat bottom and sides) |
| 42 | iii) 150 mm |
| 43 | Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. |
| 44 | b) with S Trap.With Vent |
| 45 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete. |
| 46 | iv) Bestolite (solid type) white |
| 47 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. |
| 48 | ii) C. P. Flush Pipe |
| 49 | Supplying, fitting and fixing 10 litre porcelain low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internnal PVC fittings.A) White |
| 50 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.(ii) 550 mm X 400 mm size |
| 51 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.i) 635 mm X 395 mm X 420 mm |
| 52 | Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately).i) 450 mm X 350 mm |
| 53 | Supplying , fitting and fixing wheel valve gunmental of approved brand & make tested 21 kg sq.cm (for water liens only)a) 32mm |
| 54 | Supplying , fitting and fixing C. P. Bib cock / stop cock /pillar cock of approved make & brand tested Delux heavytype (Essco) a) C. P. Bib cock |
| 55 | b) C. P. Stop cock |
| 56 | Supplying, fitting and fixing towel rail with two brackets.ii) 25 mm dia. and 600 mm long |
| 57 | Supplying, fitting and fixing soap holder. (a) PTMT (Prayag or equivalent) |
| 58 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thickwith silvering as per I.S.I. specifications supported on fibre glass frame ofany colour, frame size 550 mm X 400 mm |
| 59 | Supplying P.V.C. water storage tank of approved quality with closed topwith lid (Black) - Multilayera) 500 Lt. Capacity. |
| 60 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thickR.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick ..................................... weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part I.(iv) For 100 user1)With Pakur variety. ( JSW / JSPL/SHYAM / SRMB |
| 61 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with drybrick work upto 1.6 metre from the bottom having 150 mm intermediate cement brickwork (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with20mm thick cement plastering (1:4) to inside face ....................................slab with necessary fittings, making nacessary arrangements for pipe connections,excavation of well including shoring, dewatering and removing the exess earth fromthe premises as per direction complete in all respect with all costs of labour andmaterials.With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and1.00m inside dia. ( JSW / JSPL/SHYAM / SRMB |
| 62 | p- 49 / 1 dLabour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. |
| 63 | (A) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia. |
| 64 | (i)50 mm dia. boring etc. |
| 65 | (ii) 100 mm dia. boring etc. top enlargement |
| 66 | (B) For depth more than 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia. |
| 67 | (i)50 mm dia. boring etc. |
| 68 | P- 13 / It.- 19 (III) Supply of PVC Pipes & Fittings Schedule 80 ( medium duty ) conforming to ASTMD - 1785and threaded to match with the existing GI pipe |
| 69 | (a) 50mm dia |
| 70 | (b) 100mm dia |
| 71 | P- 52 / It.-5(ii) Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications. |
| 72 | (ii) 50 mm dia. |
| 73 | 100 X 50 Each 171.00 |
| 74 | Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. |
| 75 | (i) 50 mm dia. |
| 76 | P- 53 / It.- 10 (ii) Supplying, fitting and fixing plug of approved make conforming to I.S. |
| 77 | (ii) 50 mm |
| 78 | Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with \"V\" notch including hire and labour charges for all tools and plants and scaffolding as required. |
| 79 | Supplying and installation of submersible pump 1no , 3.0 H.P MS 66 (Pump type) ST 037 motor type approved brand, all complete, as per direction of EIC (Local cotation rate , excluding GST) |
| 80 | Supplying, fitting & fixing Name Plate /Photography |
| 81 | Add 18% GST |
| 82 | Add 1% L&W cess |
AI Tender Summary
Tender Timeline
Jun 06, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedJun 22, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJun 26, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender