| 1 | De-watering of septic tanks and soakage wells by manually or with pumping set and draining out the same out of cantt area complete all as specified and directed. |
| 2 | Taking out sludge from septic tanks incl inlet and outlet chambers, removing and depositing the sludge in a pit at a distance of minimum 50m from nearby living accn and covering the sludge in the pit with earth and finally spraying unslaked lime, dry, around the septic tank and over the pit complete all as directed Note:-Cost of earth work in the pit is deemed to be included in the unit rate quoted by the tenderer against this item). |
| 3 | Cleaning of blocked drain pipes (SGSW/humepipe) up to 100/150 /200mm bore by rodding from manholes and well flushing with water after cleaning the same all as required including disposing off the deposited sludge, etc inside pipes to a distance exc 50m & n exc200 m, burried under ground (minimum 30 cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.20 kg / Sqm and dressing of surplus soil around slope complete all as required and directed. |
| 4 | Cleaning of manholes including taking out accumulated semi liquid, sludge and other deposits such as broken bricks , silt etc from manholes of depth n.exc 1.5 m, cleaning as directed and removing the same to a distance n. exc 50 m and burried under ground (minimum 30 cm below ground level) including necessary excavation of pits in soft /loose soil and returnig, filling in including sprinking of bleaching powder at the rate of 0.20 kg / Sqm and dressing of surplus soil around to slope complete all as required and directed. |
| 5 | Demolition of brick work, built in cement mortar complete all as specified and directed. |
| 6 | M&L brick work with sub class \"B\" bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar (1:4) using old size bricks complete as in manholes, etc all as specified and directed. |
| 7 | Plain Cement Concrete 1:2:4 type B1(using 20 mm graded crushed stone aggregate) as in cills, benching and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified and directed. |
| 8 | M&L rendering 15mm thick in cement mortor 1:4 on fair faces of brick work and finishing surface even and smooth without using extra cement complete all as specified and directed. |
| 9 | Demolition of RCC n.exc 15cm thickness complete all as specified and as directed. |
| 10 | M&L precast reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cover slab of manholes, septic tank etc,set in cement mortar (1:4) including necessary form, moulds etc and including taking out/removal of existing unserviceable cover slab from manholes /septic tank complete all as specified and directed. (Note :- Reinforcement shall be measuredand paid separately) |
| 11 | M&L for Mild steel TMT bars 6 to 8mm dia and over as in reinforcement cut to length bent to shape required including cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia, complete all as specified and directed. |
| 12 | Demolition and breaking up 150 mm bore drain pipes (SGSW/AC/RCC) set in cement mortor complete all as specified and directed. |
| 13 | Demolition and breaking up 100 mm bore drain pipes (SGSW/AC/RCC) set in cement mortor complete all as specified and directed. |
| 14 | Cleaning of blocked EWC by using rubber hand pump and opening the eye and making the line clear for smooth function all as directed. |
| 15 | Cleaning of blocked IWC by using rubber hand pump and opening the eye and making the line clear for smooth function all as directed. |
| 16 | Cleaning of blocked nahani trap in bathroom / kitchen or blocked gully trap by using rubber hand pump and opening the eye and making the line clear for smooth function all as directed. |
| 17 | S&F in repairs, 75 mm bore PVC (SWR) vent cowl |
| 18 | S&F in repairs, 110 mm bore PVC (SWR) bends of any radius. |
| 19 | S&F in repairs, 110 mm bore, PVC (SWR) junction single, (Single T)equal or unequal. |
| 20 | S&F in repairs, 110 mm bore, PVC (SWR) junction double, (Double T)equal or unequal. |
| 21 | S&F in repairs 110 mm bore, PVC (SWR) Soil, waste and vent pipes single socketed, in any length with rubber ring joints laid in floors or trenches etc complete as required and as specified and directed. |
| 22 | S&F in repairs 75 mm bore, PVC (SWR) Soil, waste and vent pipes single socketed, in any length with rubber ring joints laid in floor or trenches etc complete as required and as specified and directed. |
| 23 | All as per Item No 22 above but fixed to walls. |
| 24 | S&F in repairPVC valveless, syphonic action type, flushing cistern 10 Ltr capacity, low level, white, with inlet, ball valve, float and handle including bracket etc complete all as specified and direted. |
| 25 | S&F in repairsvitreous china squatting pan, \"Orissa\" pattern, size 580mm x 440mm, white, with integral foot rests with \"P; or \"S\" trap, connection to trap, and to flushing pipe, anti-syphonage pipe, etc. alongwith making good to floor completeall as specified and directed. |
| 26 | S&F in repair Vitreous China wash down water closet pan (Pedestal Pattern), white including white plastic seat cover with mild steel CP hinging device, suitable brass CP wash jet, flush pipe fixed as in repair complete jointing, connecting and making good the disturbed surfaces all as specified and directed. |
| 27 | Excavation in trenches n exc 1.5 wide and n exc 1.5m deep in Hard/dense soil for foundations etc and getting out complete all as specified and directed. |
| 28 | Returningfilling in incl spreading, levelling watering and well ramming in layers n exc 25cm thick in soft/disintegrated rock all as specified anddirected. |
| 29 | Removing excavated materialto a distance exc 250m and n exc 500m and depositing where directed in soft / disintegrated rocks complete all as specified and directed. |
| 30 | Demolition of cement concrete (un-reinforced) of any description and in any position such as in bed for drain pipe etc complete all as specified and directed. |
| 31 | M&L plain cement concrete 1:3:6 type C2 (using 40 mm graded broken stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore drain pipes all as specified and directed. |
| 32 | M&L 150 mm dia Reinforced concrete pipes, class NP3, laid and jointed complete with collars all as specified and directed. |
| 33 | M&L PVC (SWR) pipes 150mm single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and directed. |
| 34 | S&F 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 35 | S&F 125/110 mm PVC (SWR) gully trap,jointing with solvent cement all as specified and as directed. |
| 36 | S& F Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) all as specified and directed. |
| 37 | Demolition of existing SGSW gully trap including PCC kerb etc and Supply and Fix SGSW gully trap square mouthed 100mm size set in PCC (1:3:6) type C1 block measuring 450mm and 100mm thick bed concrete and jointing to drain pipe in CM (1:1) including 100x150mm high PCC kerb in (1:2:4) type B1 with CI perforated grating 150 x 150mm bituminous coated including disposal of waste/ sludge complete all as specified and directed. |
| 38 | Demolition of PCC around floor trap and dismantling existing floor trap and cleaning the blockage of pipe from floor trap to gully trap and Supply & fix PVC floor/Nahani trap in existing pipe and embedding in CM (1:1) including lowering or raising with vertical piece with PVC pipe for jointing trap and fixing gratings at true level of floor complete all as specified and directed. |
| 39 | Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing), in floors, aprons etc .laid dry or laid dry and pointed including removing of demolished material from work site at any distance outside MD land complete all as specified and directed. |
| 40 | Material and labour for Non Skid ceramic coloured tiles (1st quality) 7 to 8mm thick ( square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tiles over and including 15 mm thick screeding in CM 1:6 complete all as specified and directed. |
| 41 | Material and labour for glazed ceramic coloured tiles of size 350 mm x 250 mm x 7 mm / 450 mm x 350 mm x 7 mm thick on vertical surfaces such as dados , skirting and risers to steps etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tiles over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 42 | Dismantaling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified anddirected. |
| 43 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and directed. |
| 44 | Same as per item No. 43 above but except sheeting (any thickness) complete all as specified and directed . Note :- Old sheet shall be obtaind from item No - 42 above) |
| 45 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed. |
| 46 | All same as per item no. 45 above but except sheeting (any thickness) complete all as specified and directed . Note :- Old sheet shall be obtaind from item No - 42 above) |
| 47 | M&L PCC 1:4:8type D2(using 40 mm graded stone aggregate) as in foundations, filling or as in sub base and mass concrete, complete all as specified and directed. |
| 48 | M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or rectangular) area of each tiles exc 0.11 sqm but not exc 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tiles over and including 15 mm thick screed bed in cement mortar complete all as specified and directed. |
| 49 | M&L for 75mm thick, PCC 1:3:6, Type C-2, using 40mm graded stone aggregate as in plinth protection etc., laid in alternate pannel, surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 50 | M&L for providing, cement concrete 1:2:4 type B0(using 12.5mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, Chajjas, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, neelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, completeall as specified and directed. |
| 51 | M & L for glazed ceramic coloured / printed tiles 450mm x 300mmx7mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tiles over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 52 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc,) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed. |
| 53 | S & F for powder coated GI Snap grid system of size 605 X 605 mm for ceiling fixed to walls with rawl plugs and screws and hang to roof members with 2 mm dia GI wire comprising of the following sections complete all as specified and directed:- (i) Maint Tee 28mmx24mmx0.3mm thick, (ii) Cross Tee 28mmx24mmx0.3mm thick and (iii) Wall angle 24mmx24mmx0.3mm thick complete all as specified and directed. |
| 54 | S & F 4 mm thick designer ceiling (E-board classic tiles) for insulation and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or GI sanp grid or withstaples on snap grid as in ceilingwith and including dusting of surface and applying two coats of oil bond distemper over a coat of primer complete all as specified and directed. |
| 55 | S&F PVC Soffit systemfor False Ceiling / Wall Panelling purpose, to be screw fixed on a GI (GI-0.4mm) Channels or equivalent and standard hardware framework with interlocking between panels, Panel Size: 2700x300mm/; Panel colours : 4 shades of Wooden (Walnut / Winchestar oak / Oak /Golden Oak ) or 3 Shades of Uni Colour (White / Brown / Graphite); to be applied with finishing trims in same colour combination of soffit panel (J - Trim & T – Trim for False Ceilings. Panels to be in strict compliance with PN-EN ISO 527-1:2012 / PN-EN ISO 527-2:2012. Soffit Panels, 340 mm (effective usage area of 300mm) wide, 12 mm deep, 1.2 mm thick PVC sheets, plain / perforated / hidden perforated without non-woven acoustic textile. Panels feature a 11 mm wide flange for interlocking between the panels. Optionally the flange with 11 x 3 mm ventilation holes can be used to achieve a ventilated ceiling. Panels to be manufactured from Solid PVC surfacePanels have a size of 2700x340mm; Effective size for Coverage: 2700x300mm. Panels to be installed using J – Trim along the periphery and to be coupled in longitudinal direction using T – Trim of the same colour combination of the panel for False Ceiling applications all as specified and directed. |
| 56 | Dismantling timber scantlings 40sqcm and over in section, in Unframed work complete all as specified and directed . |
| 57 | M&L Timber framed andfixed secand class hard wood clen sawn secand class hard wood in scantlings completeall as specified and directed. |
| 58 | Dismantling of wrought iron or mild steel work of any description not otherwise provided etc. |
| 59 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) of Fe 410-W (Gde E250) quality-A including distance pieces, cleats etc completeall as specified and directed. |
| 60 | M&L for sunken floor treatment as follows:-(i) The sunken portion shall be tested for leakage/ seepage/ dampness by pounding with water for 72 hours.In case any defect is noticed the portion shall be grouted with cement slurry mixed with suitable chemical & tested again.The process of grouting and testing shall be prepared till leakage/ seepage/ dampness is eliminated.(ii) Demolition of concrete of any description and in any position not otherwise specially provided for in any type of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete all as specified and directed.(iii)Layiong of 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout vertical sides shall be plastered in cement mortar 1:3.(iv) After laying sewage/ plumbing pipes with fixtures in position 2 coats of OMIPLAS EP-101 epoxy compound shall be applied complete all as specified and directed.(v) Test again of water tightness by pounding for 72 hours & rectify defects if any till total elimination of defects complete all as specified anddirected.(vi) Spouts of 25mm dia GI pipe light grade projecting 450mm clear of face outer a wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water including cutting holes and making good if needed complete all as specified and directed.(vii)M& L to fill the sunken floor with PCC (1:5:10) type E-2 using brick aggregate over the treated surface complete all as specified and directed. |
| 61 | S & F75mm bore PVC (SWR) bends of any radius completeall as specified and directed. |
| 62 | Dismatling & Disconnecting old existingPVC water tankexc 250 Ltr and n. exc 500Ltr . And removing to store completeall as specified and directed. |
| 63 | S & F Rotational moulded PVC water storage tanks 500 Ltrs capcity (cylindrical vertical with closed top) hoissted with and including ball valves high pressure of PTMT with epoxy coated Aluminium rod of 20 mm bore & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight210 gms) fixed in position complete all as specified and directed. |
| 64 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required and reconnecting / re-fixing in position after cleaning of water tank, capacity 250 to 500 ltrs with all scales and dirts from inside of tank andmouth of inlet/outlet using bleaching powder and washed with water including supplying and fixing of GI fitting required as per site requirement complete all as specified and directed. |
| 65 | S&F 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) completeall as specified and directed. |
| 66 | Taking up or down steel water tubing and connecting incl cleaning for refixing or removal to stores for 15mm bore, complete all as specified anddirected. |
| 67 | S&F 15mm dia GI pipe medium grade with all fittings and fixed complete to walls or laid in floors complete all as spcified and as directed. |
| 68 | Taking down existing unserviceable roof treatement of any description including cement plaster, any thickness from roof surface, cleaning of roof surface and preparing it for further treatement and removing the debries/ rubbish material from site complete all as specified anddirected. |
| 69 | Supplying and laying APP based modified water proofing polymeric membrane, reinforcemed with nonwoven polyester fabric matt (weight not less than 150 gms/sqm) ofminimum 3 mm thick and minimum weighing not less than 3 kg/sqm,laid over bituminous primer on 15mm thick plastered sufaces layer in CM 1:4 with water proofing compound (WPC )@3% by weight of cement on concrete surface roof / parapet, overlap of minimum 75 mm on longitudinal direction and 100 mm on the transverse direction by thermo-fused torchflame application method and top surfaces to be treated with two coat of aluminium paint @0.15 Kg/Sqm or as per manufacturers instructionscomplete all as specified and directed . |
| 70 | Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc.&removing rubbish to a disance not exc 250mcomplete all as specified and directed. |
| 71 | M&L for rendering 15 mm thick on fair faces of brick work or stone masonry or concrete surfaces in cement mortar 1:4and finished fair and even without using extra cement incl; mixing of water proofing compound of approved makecomplete all as specified and directed. Note :-WPC shall be measured and paid separatly. |
| 72 | M&L for rendering 15 mm thick on fair faces of brick work or stone masonry or concrete surfaces in cement mortar 1:6and finished fair and even without using extra cement complete all as specified and directed |
| 73 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 finished smooth and even in ceiling without using extra cement completeall as specified and directed. |
| 74 | S&F in repair of‘L’ type or ‘J’ type or cranked hook bolts with double bitumen washer with proper arrengement in roof or wall and making good Completeall as specified and directed. |
| 75 | S&F monkey protection lid made out of galvanised plane sheet 16 gauge semi circular of dia 56 cm alongwith reveted nails 2 inches including all necessary locking arrengements all as specified and directed. |
| 76 | S&F Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union fordischarge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) all as specified and directed. |
| 77 | S& F in repair 6 mm thick Plywood, grade BWR, type BB, fixed with nailsto timber frame work or in roof for monkey protection. Note : This may be executed in patch work also. |
| 78 | Supply only Integral water proofing compound ISI marked complete all as specified and directed. |
| 79 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |