Tender For Infrastructure Development Works Small Shed 125 Mtr Godown Drain Service Roadalong With Electrification At Chanchal Krishak Bazar Dist Malda
Tender Value
3.75 Crore
Estimated cost
Bid Submission
04 Jul 2023
0 days left
EMD
7.50 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
chanchal → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Infrastructure Development Works Small Shed 125 Mtr Godown Drain Service Roadalong With Electrification At Chanchal Krishak Bazar Dist Malda
BOQ
| Sl. No. | Item Description |
| 1 | Godown ,Shed and Drain |
| 2 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soilbut excluding laterite or sandstone) including removing, spreading or stacking the spoils within removing, removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Transport:(a) Depth of excavation not exceeding 1,500 |
| 3 | (b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring |
| 4 | Post Constructional Measures :(a) Anti-termite treatment to the outside of foundations with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1%concentration) with water by weight including cutting shallow channel by excavating soil along and close to the wall face ensuring uniform dispersal of the chemical emulsion to a depth of 300mm. from the ground level by rodding with 12mm. dia. M.S. rod at 150mm.interval in the channel. 1.75 litres of chemical emulsion per metre length shall be used and a balance quantity of 0.5 litres of the chemical emulsion per running metre shall then be used to treat the back fill earth by directing the spray of the imulsion towards the wall surface. The entire work is to be carried out as per specification laid down in para 4.3.1.1 of code IS-6313 (Part-III) 1981. |
| 5 | Pre-Constructional Anti-termite measures:(c)Antitermitetreatmenttothetopsurfaceoftheconsolidatedearthwithinplinthwallswithchemicalemulsionbyadmixingchloropyrofosemulsifiableconcentrates( 1%concentration )withwaterbyweightattherateof5Litrespersq.m.ofthesurfacebeforesandbedorsub-gradeislaid.Holesupto50mm.to75mm.deepat150mm.centretocentrebothwaysshallbemadewith12mm,diametermildsteelrodonthesurfacetofacilitatesaturationofthesoilwiththechemicalemulsion.Theworkshallbecarriedoutasperspecificationdescribedinpara6.4ofcodeIS-6313( part - II )1981.( ModeofmeasurmentwillbeperSq.m.ofplanareaofplinthtreated.) |
| 6 | (A) Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 7 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation. |
| 8 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 9 | Supplying and laying Polythene Sheet (150gm/sq.m) over damp proof course or below flooring or roof terracing or in foundation trenches. |
| 10 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 11 | Cement concrete with graded stone ballast (40 mmsize) excluding shutteringground floor and foundationwith Proportion(6:3:1) |
| 12 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Varietya) For Foundation and Plintha) For Foundation and Plinth |
| 13 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary),cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) Other than SAIL/TATA/RINL(i) For works in foundation, basement and upto roof of ground floor/upto 4 m |
| 14 | Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth |
| 15 | b) Superstructure |
| 16 | Above 4.00m |
| 17 | 125mm thick brick work with 1st class bricks in cement mortar (4:1) in ground floor. |
| 18 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick toppingUsing grey cement : (iii) 35 mm. thick |
| 19 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](2) With 1:4 Cement morter(a) 15 mm thick plaster ( External)(i) Ground Floor |
| 20 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) With 6:1 cement mortar 20 mm thick plaster. Ground Floor. |
| 21 | (i) Ground Floor |
| 22 | ii) Internal plasterb)Above 4.0 Mtr. |
| 23 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary With 1:6 cement mortar 15 mm. thick plaster. Ground Floor |
| 24 | (a) Upto 4mtr |
| 25 | b)Above 4.0 Mtr. |
| 26 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface], (2) With 1:4 Cement morter, (a) 15 mm thick plaster ( External) |
| 27 | Neat Cement Punning about 1.5mm thick in wall dado, floor, drain etc.Partion wall |
| 28 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.In Ground Floor: (b) Two Coats |
| 29 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat)a) Normal Acrylic Emulsion |
| 30 | Painting with ready mixed red lead paint of approved make and brand :(a) One coat |
| 31 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :(iv) Two coats (with any shade except white) |
| 32 | Supplying,Fitting & Fixing UPVC pipes A- Type and fittings confirming to IS : 13592 - 1992 with all necessary clamps nails,including making holes in wall, Floor etc. cutting trenches in any soil through masonry concrete structures etc. if necessary and mending good damags including joining with jointing materials (Spun Yarn,Valamoid/Bitumen/M-Seal etc.)Complete. |
| 33 | A) UPVC Pipes |
| 34 | (ii) 110 mm dia |
| 35 | © Bend 87.5 degree |
| 36 | (ii) 110 mm dia |
| 37 | (d) Shoe |
| 38 | (ii) 110 mm dia |
| 39 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or partthereof. Ii) For roof truss worksc) Spanup to 15 Mtr |
| 40 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colourcoated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lapand one corrugation minimum side lap. (Payment to be madeon area of finished work).(i) In Roof:-a) With 0.5 mm thick sheet |
| 41 | Galvanised iron sheets valley gutter with perimeter not less than 750 mm with 225 mm lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley guttermade of 0.63 mm. thick sheets. (300mm End lapping) |
| 42 | Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping)A) 300 mm lapping each way(a) With 0.60 mm sheet |
| 43 | Holding down bolt with nut including 100 x 100 x 6 mm plate washerat bottom fitted complete and packing the hole with cement concreteor cement grout as directed.(ii) 20 mm dia bolt.(c) 600 mm long |
| 44 | (a) Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rollingshutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. |
| 45 | Protective and decorative acrylic exterior emulsion paint of approved quality as per manufacturers specification and as per EIC to be applied over acrylic primer as required. The rate includes cost of materials, labour, scaffolding and all incidental charges but excluding the cost of primer. In ground floor( two coats) a) Normal Acrylic Emulsion |
| 46 | Applying Interior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. ii) Solvent based interior grade Acrylic Primer |
| 47 | Applying Acrylic Emulsion paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two Coats)i) standard Quality |
| 48 | Supplying, fitting & fixing 1.5mm thick Trapezoidal profile corrugation Polycarbonate clear sheet made of national brand, excluding the supporting frame work, fitted and fixed with 10mm dia x 55mm Self-driving screws, EPDM washers and putty complete with 150mm end lap and one corrugation minimum side lap complete as per specification & direction of Engineer-incharge including materials, labour, taxes and all other incidental charges (Payment to be made on area of finished work).In Roof5%Area of Zn-Al alloy (55% Al & 45% Zn) |
| 49 | Supplying,fitting and fixing Turbine Air Ventilator is made of good quality stainless steel jindal made and neck dia. 24 inch, Turbine dia. 31 inch, Height 18 inch, centre shaft 30mm dia. SS outer jacket & 12mm dia. SS shaft, nett weight 6.5kg with 42 nos vanes & MOC- SS430 : 6.1 inch including 1.5mm thick Metal base Mounting base plate (3 feet x 3 feet & weight 4kg), Inner & ouer ArmsMS withElectro zinc plating. |
| 50 | Service road |
| 51 | Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1 for Rural Roads of MORD. (Borrow pit /pre work post work measurement) |
| 52 | Supplying ,spreading,consolidating stone dust etc . |
| 53 | Construction of Sub Base using Local Materials:Construction of Sub Base using Local Materials, spreading in uniform layers with Motor grader on prepared surface, including screening the metal as necessary, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, lighting, guarding and barricading including cost and carriage of all materials and making necessary earthen bundh of one metre wide on each side to protect the edges complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).(i) For Construction of Sub Base by compacting 1stclass brick aggregates (40 mm down) and sand (in proportion of 60:40). |
| 54 | Water Bound Macadam Base CourseProviding, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate watering including lighting, guarding, barricading and making necessary earthen bundh of one metre width on each side and preparing the bed by necessary cutting or filling, including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density.(i) Grading-II Aggregate (53mm to 22.4 mm) Using Stone Screening Type B. |
| 55 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 56 | Hire and labour charges for Shuttering with or without staging upto 4.0 m height using approved stout props with wooden planks/ply wood/steel sheet plate with required bracing for any kind of plain or reinforced concrete works in all sorts of minor structure including culvert, box culvert, crossdrain etc. The rate is inclusive of fitting, fixing and striking out after completion of work as per specification and direction. b) Where staging is not required. |
| 57 | (I) Cement concrete with graded stone ballast (40 mm size excludingshuttering)(a) 1:3:6 proportion(A) [Pakur Variety] |
| 58 | Ordinary Cement Concrete (mix 1:1.5:3) with graded stone chips (20mm nominal size) exc. Shuttering & reinforcement if any ,in ground floor as per relevant IS code. (A) [Pakur Variety] |
| 59 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary),cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) Other than SAIL/TATA/RINL(i) For works in foundation, basement and upto roof of ground floor/upto 4 m |
| 60 | Bituminous filler of approved type in expansion joints of dummy joints including finishing the top surface as directed. |
| 61 | Electrical |
| 62 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required4 x 36/0.3 (2.5 sqmm) + 2 x 22/0.3 (1.5 sqmm) ECC |
| 63 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\"(Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated &unsheathed copper wire for ECC, to light points with 2 no. 2 way Piano Key type switchfixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mm x 100mm x 62.5mm inspection box making earthing attachment, painting the MS box and mending good the damages to original finishAverage run 12 mtr |
| 64 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm)single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Keytype switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finishOn Board |
| 65 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthingattachment. 2+6 way |
| 66 | Supplying and fixing 240V MCB Isolator on din rail of existing DBs and necessary connection.40 Amp |
| 67 | Supplying and fixing 6-32 A 240 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection |
| 68 | Supply of 35 Watt PHOTON ULTRA PLUS High efficacy wellglass which consumes lesser energy and maintains high lighting levels. Luminaire efficacy of 140Lm/Watt to reduce quantity/wattage thereby reducing operational cost. Ingress protection of IP66. Available in Clear PC. Model No.CIP-311-35-57-HL4-CP-NSG.Make-Crompton or equivalent. |
| 69 | 15. Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length. |
| 70 | Supply of 2 Core 4 Sq mm Alluminium XLPE /PVC Armoured cable for 16 A DP main switch to Out side DP Main Switch and Out Side DP Main Switch to Different Wall Bracket Light Point. |
| 71 | Laying of cable2 core 4 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 72 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables of 2 core 4 sqmm |
| 73 | Finishing the end of 2 core 4 sqmm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials |
| 74 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamp with bolts, nuts etc. including painting with anticorrosive paint |
| 75 | Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite / Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. Supply & Fixing 240 V 16A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 76 | Supply of45 watt RAPTOR PRO street lights are aerodynamically designed for all weather conditions with excellent thermal management,made up of pressure die cast housing with toughened glass andhigh power LED\"s with secondary optics and IP66 protection.Efficacy = 110/125/135LPW, 10KV SPD Included. Model No-CRP-409-45-57-SL-GL-NSG. Make-Crompton or equivalent |
| 77 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 78 | Excavation of soil for installation of Earth Electrode and filling & ramming for soft Soil. |
| 79 | Earthing with 50mm dia G.I. pipe (TATA-M) 3.64mm thick * 3.04 Mtrs. Long and 1*4 WG wire (4 Mtr. Long) 13mm dia * 80mm long G.I. bolts double washers incl. S&F dia pipe protection (1Mtr long) to be filled with bitumen partly under the G.L. and partly above G.L. driven to an average depth of 3.65Mtrs .below the G.L. and restoring the surface duly remmed |
| 80 | Extra treatment of soil by using salt and charcoal for pipe electrode as required. |
| 81 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 82 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete withGI bolts, nuts, washers, spacing insulators etc. as required |
| 83 | Connecting the equipments to early busbar incl. S&F No. 8 SWG G.I. wire onwall /floor with stapels as per G.S. |
| 84 | Supplying of one no 2 core 10 sqmm Alluminiuam armoured cable. |
| 85 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 86 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below For 2 coreupto 10 sqmm |
| 87 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 2 core 10 sqmm cable |
| 88 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required4 x 36/0.3 (2.5 sqmm) + 2 x 22/0.3 (1.5 sqmm) ECC |
| 89 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\"(Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated &unsheathed copper wire for ECC, to light points with 2 no. 2 way Piano Key type switchfixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mm x 100mm x 62.5mm inspection box making earthing attachment, painting the MS box and mending good the damages to original finish Average run 12 mtr |
| 90 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm)single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Keytype switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finishOn Board |
| 91 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthingattachment. 2+6 way |
| 92 | Supplying and fixing 240V MCB Isolator on din rail of existing DBs and necessary connection.40 Amp |
| 93 | Supplying and fixing 2 WayMCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment |
| 94 | Supplying and fixing 6-32 A 240 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection |
| 95 | 15. Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length. |
| 96 | Supply of 2 Core 4 Sq mm Alluminium XLPE /PVC Armoured cable for 16 A DP main switch to Out side DP Main Switch and Out Side DP Main Switch to Different Wall Bracket Light Point. |
| 97 | Laying of cable2 core 4 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 98 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables of 2 core 4 sqmm |
| 99 | Finishing the end of 2 core 4 sqmm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials |
| 100 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamp with bolts, nuts etc. including painting with anticorrosive paint |
| 101 | Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite / Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. Supply & Fixing 240 V 16A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 102 | Supply of45 watt RAPTOR PRO street lights are aerodynamically designed for all weather conditions with excellent thermal management,made up of pressure die cast housing with toughened glass andhigh power LED\"s with secondary optics and IP66 protection.Efficacy = 110/125/135LPW, 10KV SPD Included. Model No-CRP-409-45-57-SL-GL-NSG. Make-Crompton or equivalent |
| 103 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 104 | Excavation of soil for installation of Earth Electrode and filling & ramming for soft Soil. |
| 105 | Earthing with 50mm dia G.I. pipe (TATA-M) 3.64mm thick * 3.04 Mtrs. Long and 1*4 WG wire (4 Mtr. Long) 13mm dia * 80mm long G.I. bolts double washers incl. S&F dia pipe protection (1Mtr long) to be filled with bitumen partly under the G.L. and partly above G.L. driven to an average depth of 3.65Mtrs .below the G.L. and restoring the surface duly remmed |
| 106 | Extra treatment of soil by using salt and charcoal for pipe electrode as required. |
| 107 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 108 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete withGI bolts, nuts, washers, spacing insulators etc. as required |
| 109 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete withGI bolts, nuts, washers, spacing insulators etc. as required |
| 110 | Connecting the equipments to early busbar incl. S&F No. 8 SWG G.I. wire onwall /floor with stapels as per G.S. |
| 111 | Supply of 40 Watt PHOTON ULTRA PLUS High efficacy wellglass which consumes lesser energy and maintains high lighting levels. Luminaire efficacy of 140Lm/Watt to reduce quantity/wattage thereby reducing operational cost. Ingress protection of IP66. Available in Clear PC. Model No. CIP-311-40-57-HL4-CP-NSG. Make-Crompton or equivalent. |
| 112 | Add 18%G.S.T |
| 113 | Add 1% cess |
AI Tender Summary
Tender Timeline
Jun 06, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedJul 04, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 06, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender