Tender For Repair And Replacement Of Vertical Subersible Polder Type Pumps Along With Electrical Control Panels And Generator Complete In All Respects For Pump House Of Gangowal Lift Scheme Off Taking At Rd. 88731 Mtr. L/S Of Kandi Canal Stage-Ii., hoshiarpur-Punjab

Water Resources Department-WRD has published Tender For Repair And Replacement Of Vertical Subersible Polder Type Pumps Along With Electrical Control Panels And Generator Complete In All Respects For Pump House Of Gangowal Lift Scheme Off Taking At Rd. 88731 Mtr. L/S Of Kandi Canal Stage-Ii.. Submission Date for this Tender is 20-06-2023. Electric Generator Tenders in hoshiarpur Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

38029925
Tender For Repair And Replacement Of Vertical Subersible Polder Type Pumps Along With Electrical Control Panels And Generator Complete In All Respects For Pump House Of Gangowal Lift Scheme Off Taking At Rd. 88731 Mtr. L/S Of Kandi Canal Stage-Ii.
Open Tender
Indian
Punjab
hoshiarpur
20-06-2023

Tender Details

Repair And Replacement Of Vertical Subersible Polder Type Pumps Along With Electrical Control Panels And Generator Complete In All Respects For Pump House Of Gangowal Lift Scheme Off Taking At Rd. 88731 Mtr. L/S Of Kandi Canal Stage-Ii.

Key Value

Document Fees
INR 5000 /-
EMD
INR 171170.0 /-
Tender Value
INR 85.58 Lakhs /-

BOQ Items

Name of Work: REPAIR AND REPLACEMENT OF VERTICAL SUBMERSIBLE POLDER TYPE PUMPS ALONG WITH ELECTRICAL CONTROL PANELS AND GENERATOR COMPLETE IN ALL RESPECTS FOR PUMP HOUSE OF GANGOWAL LIFT SCHEME OFF TAKING RD 88731 M/LEFT SIDE OF KANDI CANAL STAGE-II
Sl. No. Item Description
1Supplying, Installing, Testing and Commissioning of 11kV vacuum circuit breaker of 1250Amp. Draw out type panel for incoming 110 VDC operative control wiring, comprising of 3Nos.double core epoxy resin .indicating lamps for ON/OFF TRIP/TRIP CKT Healthy, spring charged, R,Y,B Phase Indicators, draw out type epoxy resin, TP IDMTL microprocessor based relay having 3 over current elements & one earthfault element, 2 nos. instantaneous under voltage relays reset table between 20% to 80% stepped of rated voltage with associated time delay relay, 1No.network analyzer(measuring frequency time counter),breaker control switch, control fuses, panel illumination lamp space heater thermostat S/W, copper bus bar 630A,6.6KV epoxy insulator, cable termination for power cable gland for control cable, control wiring etc complete housed in M.S cubical panel of suitable sizes.Make: Kirloskar/ ABB/ C&S/ Areva /Crompton / SIEMENS /L&T (Replacement of old defective VCB with New VCB as per latest new PSPCL regulations)
2Supplying, Installing ,Testing, Commissioning of 1000kVA ,3 Phase,4 wire,50 cycle, oil immersed, outdoor type, naturally self cooled 11kV/.433kV.Transformer double copper wound. The transformer shall be contained in mild steel plain of radiator cooled tank and temperature shall not exceed 50deg C for winding measurement by resistance shall not exceed 50Deg C over an ambient temperature of 50deg C. Tapings will be on HV windings to obtain a variation as +5% to -10% in steps of 2.5% through OFF LOAD TAP CHANGER. The Transformer is designed and tested to comply with National and International Standards-BIS-2026/IEC-76/BS-171 etc. The transformer shall be finished with epoxy paint of a shade corresponding to IS632/631.Out door type.HV /LV both end cable box. buchloz relay (alarm/trip),winding temperature including cost of RCC foundation as per required size (alarm/trip) Make: Kirloskar/Areva/ABB/Amson/Hindustan/Indian (Replacement of existing transformer not repairable with New transformer as per latest new PSPCL regulations)
3Replacement of damaged 11KV cable from METERS to VCB grade aluminium armoured conductor XLPE (E) 3Core 95 sqmm cable suitable for supplying for 11 kV primary complete in all respects. Make : Havells / BCH / ECKO / ICL
4Supplying of HT VCB Terminals indoor- upto 120 sqmm Make: ISI marked
5Supplying of HT TRF. Terminals outdoor - upto 120sqmm Make: ISI marked
6Labour work for testingall types of existing damaged HT/LTcables from Main starter Panel to TRF /D.G set andTRF to VCB with high voltage and low voltage magger values and earth testing for any leakages and removing defects by replacing the defective part and making new joints , glands, thinmbles etc for making it same as for operational use ( labour work only )
7Providing of Cable Connection outgoing and Incoming terminals of the Alu and copper thimbles etc complete in all respect.
8Supplyingof 400 sqmm 3.5 core Aluminium cable armouredgrade cablesconductor,PVC/XLPE insulated aluminium conductor armoured,extruded outer PVC sheathed 1100V,grade cables. Make : Indian Cable CCI / Universal cables / ICL / Havells. /Polycab
9Supplying of 2.5 sqmm 3 core copper cable armoured in PVC rigid flexible cable Make :Havells /Polycab
10Providing and Fixing of flat Submersible3 corecopper conductor cable confirming to IS:694 flexible 1100 V size 70 sq.mmMake B.C.H/ L&T/Finolex/Havells/Polycab/KEI
11Supply & laying of GI earthing strip 50 mm x 6mmand earthing Cable inside pump chamber for earthing.
12Repair & Replacement OF MINOR COMPONENTS incluiding dehydration, chemical cleaning, X-terminator along with labour work for taking out springs mechanisms of ACB and replacing with new components to make main control panel operationalized consisting of 1 NO. Motorized ACB 1250A. 3 Pole 50 KA Microprocessor Based with O/L, S/C & E/F protections; 1 NO. Ammeter 0-1250A; 1NO. Volt Meter 0-500 V; 1NO. Ammeter Selector Switch; 1 NO. Voltmeter Selector Switch; 3 NOS. Indication Lamp R Y B; 3 NOS. Control MCB 2A; 4 NOS. CT"s 1250/5; 4 NOS. Control Terminals; 1 NO. 16 A Neutral Link; 4 NOS. CT Shorting 1no. 1600A. 3 Pole 50 KA Microprocessor Based Motorized ACB with O/L, S/C &E/F protections; 1 NO. AM Meter 0-1600A; 1NO. Volt Meter 0-500 V; 1NO. Ammeter Selector Switch; 1 NO. Voltmeter Selector Switch; 3 NOS. Indication Lamp R Y B; 3 NOS. Control MCB 2A; 4 NOS. CT"s 1600/5; 4 NOS. Control Terminals; 1 NO. 16 A Neutral Link; 4 NOS. CT Shorting Link
13Repair & Replacement of minor components inculding dehydration,cleaning taking out softstarters fixing in main panel for operationlize for use of repcaking of terminations of control wiring replacement of defective components and re-programming150 HP SOFT STARTER; 250A , MCCB with Adjustable overload protection soft starter 150 HP 3-wire suitable for inline connection with LCD display for precise motor start, stop, monitor, control and protection having adjustable settings like initial voltage output between 30-70% of the nominal voltage, Soft starter must have integrated motor and load protection features like overload protection with dual overload class settings, high current protection, locked rotor protection, under load protection and torque control feature
14Replacement of new 150 HP SOFT STARTER; Adjustable overload protection soft starter 150 HP3-wire suitable for inline connection with LCD display for precise motor start, stop, monitor, control and protection having adjustable settings like initial voltage output between 30-70% of the nominal voltage, Dual current limit between 200% and 500% of the soft starter"s rated full load current with timer, adjustable Ramp in and ramp out time, kick start etc. Soft starter must have integrated motor and load protection features like overload protection with dual overload class settings, high current protection, locked rotor protection, under load protection and torque control feature for precise pump control compateable with SCADA and PLC Make of softstarters- ABB/Schnider/Seimens
15Repair & Replacement OF MINOR COMPONENTS incluiding dehydration, chemical cleaning, X-terminator along with labour work for taking out damaged capacitors and replacing with new capacitors to make main 150 KVAR APFC panel operationalized 5 Nos. 25 KVAR capacitor feeder; 5 nos. 63 amp 3P MCCB 10 KA; 5 nos. 73 amp power contactors: 10 nos. start/stop push buttons; 10nos. indicating lamps ON/OFF: 5 nos. Auto/Manual Selector switch, Control MCB 2A; Neutral Link; Capacitor should be MPP heavyduty 1 Nos. 15 KVAR capacitor feeder: 1 nos. 40 amp 3P MCCB 10 KA; 1 nos. 40 amp power contactor; 2 nos. start/stop push buttons; 2nos. indicating lamps ON/OFF; 1 nos. Auto/Manual Selector switch, Control MCB 2A; Neutral Link; Capacitor should be MPP heavy duty 1 Nos. 10 KVAR capacitor feeder; 1 nos. 40 amp 3P MCCB 10 KA; 1 nos. 32 amp power contactors; 2 nos. start/stop push buttons; 2nos. indicating lamps ON/OFF: 1 nos. Auto/Manual Selector switch, Control MCB 2A: Neutral Link; Capacitor MPP heavy duty make of Capcitors EPCOS/ L&T/ SIEMENS/SCHINDER/ABB
16Repair & Replacement OF MINOR COMPONENTS incluiding dehydration, chemical cleaning, X-terminator along with labour work for taking out damaged capacitors and replacing with new capacitors to make main 200 KVAR APFC panel operationalized 7 Nos. 25 KVAR capacitor feeder; 7 nos. 63 amp 3P MCCB 10 KA; 7 nos. 73 amp power contactors; 14 nos. start/stop push buttons; 14nos. indicating lamps ON/OFF; 7 nos. Auto/Manual Selector switch, Control MCB 2A; Neutral Link; Capacitor should be MPP heavy 1 Nos. 15 KVAR capacitor feeder; 1 nos. 40 amp 3P MCCB 10 KA; 1 nos. 40 amp power contactor; 2 nos. start/stop push buttons; 2nos. indicating lamps ON/OFF: 1 nos. Auto/Manual Selector switch, Control MCB 2A; Neutral Link; Capacitor should be MPP heavy duty 1 Nos. 10 KVAR capacitor feeder; 1 nos. 40 amp 3P MCCB 10 KA; 1 nos. 32 amp power contactors; 2 nos. start/stop push buttons; 2nos. indicating lamps ON/OFF; 1nos. Auto/Manual Selector switch, Control MCB 2A; Neutral Link; Capacitor MPP heavy duty make of Capcitors EPCOS/ L&T/ SIEMENS/SCHINDER/ABB
17Repair, Replacement and Dismantling of ExistingConnected 400 KVR alternator 3 Phase ,415 V ,50 Hz Voltage 380-440V Frequency 50Hz ,Voltage 380-440V ,Current @ 0.8P F (Amps) 556.5 ,Type 4 Pole , Rotating field Temperature rise 125 Deg. C (Class H),Sealed Coupling Flexible disc closed coupledalternator mounted on a common base frame, along with microprocessor based electronic control panel with indicators and MCCB ofsuitable capacity, for displaying and protection of various electronic, electrical and mechanical parameters via Frequency, current, RPM, Cumulative Run hours, Lube oil pressure, coolant temperature, Charging current (DC), under and over voltage, under over speed, Low fuel shout down system, unbalanced load protection and emergency off including other accessories i.e. silencer and any other accessory required to meet the latest standard guidelines of CPCB, Anti vibration pads Make caterpillar/kirloskar /Greaves/ Crompton/ cummins . • Manual control Panel, • Battery 2 Nos. 12 V 180 AH Maintenance free with leads •Brushlessalternator • Self-excited, self-regulatedClass ‘H’ insulation limited to temperature rise of class H •Salient pole revolving field •Single bearing •Automatic voltage regulator
18Providing and fixing of HT panel battery bank and battery charger 24 VOLT DC supply capacity for 1250 Amb VCB safety protection, metering, annunciation, charger cabinet, wiring etc complete in all respect as per site requirement
19Supply and Fixing of Single monorail along with chain pulley block lift of 10 mtr capacity of 3 ton span on existing MS structure and welding at site along with repairing oiling and greasing in all respect to make unity in running condition.
20Repair and rewinding of existing VERTICAL SUBMERSIBLE POLDER TYPE PUMPS 150 HP along with lifting shipping to workshop and back lowering to site including making of water proof cable joints from inside of pump casing and changing of lubricants and replacement of defective parts if any inside the pump like Bushes, wear rings, bush sleeves and thrust plate and bearings, carter couplings and mechanical seal complete in all respects
21Supply & laying of shock proof HT rubber matting for control panel room in 2 SQM sheet as per site requirement
22Rent of Diesel Gen. set including cost of diesel etc.complete in all respects for execution of work for reparing at site
23Repairing including providing of MS ladders, framed grills, gratings, iron doors, widows shutter repairs, and gate repair panels room etc. including cost of fixing and grouting complete re fixing in position
24Any Other Items (CSR)