Tender For City Beautification Works At Bundi, bundi-Rajasthan

Rajasthan Urban Infrastructure Development Project-RUIDP has published Tender For City Beautification Works At Bundi. Submission Date for this Tender is 11-07-2023. Civil Work Tenders in bundi Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

38024080
Corrigendum : Tender For City Beautification Works At Bundi
Open Tender
Indian
Rajasthan
bundi
11-07-2023

Tender Details

Tender For City Beautification Works At Bundi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Jun-2023 Addendum 1 Technical Bid 11-07-2023

Key Value

Document Fees
INR 10000 /-
EMD
INR 1600000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: City Beautification works at Bundi
Sl. No. Item Description
1Civil Work
2Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit to required compaction as per oRT&H specification clause 201. (Measurment of girth to be done at height of 1 m above ground level)Girth from 300 mm to 600 mm
3Clearing and grubbing road land including uprooting rankvegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to a lead of 50 metres from road boundary including removal and disposal of top organic soil not exceeding 150 mm in thickness as directed by Engineer.In area of light jungle
4Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding herever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer.
5Lime Concrete, cement concrete grade M-10 (1:5:10) and below
6Prestressed /Reinforced cement concrete with separating, cleaning, straightening and cutting of bars
7Dismantling Brick / Tile work In cement mortar
8Rubble stone masonry in cement mortar.
9Dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m.
10Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level.In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc.Depth upto 1.5 m
11Add extra for over all depth of excavation above 1.5 m and upto 3.0m over item no 4.10.1.1
12Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceedin 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m.
13Compensation for earth, taken from private land with all lead and lift (Land to be arranged by private negotiations by the Contractor) [MOST Specification : Clause 301 to 305]
14Carriage of Materials by mechanical transport including loading, unloading and stacking ::Earth upto 10 Km
15Supplying Chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified.
16Diluting and injecting Chlorpyriphos/ Lindane E.C. 20% with 1% concentration for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.
17Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
18Centring and shuttering with plywood or steel sheet upto two storiesor height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for
19Foundations, footings, bases of columns, etc. for mass concrete.
20Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
21Columns, Pillars, Piers, Abutments, Posts and Struts
22Suspended floors, roofs, landings, balconies and access platform
23Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix)
24Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix)
25Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement:M-20 Grade Concrete (1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) -As per design mix)
26Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all completeThermo-Mechanically Treated bars
27Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
28Half brick masonry with FPS bricks of class designation 75 in superstructure above plinth level upto two stories. Cement mortar 1:4 (1 cement :4 coarse sand)
29Random rubble masonry with hard stone in foundation and plinth :Cement mortar 1:6 (1 cement : 6 coarse sand)
30Extra for random rubble masonry with hard stone in superstructureabove plinth level and upto two stories.
31Extra for random rubble masonry with hard stone in : Square or rectangular pillars
32Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
33Steel work welded in built up sections/ framed work including cutting,hoisting, fixing in position and applying a priming coat of approvedsteel primer using structural steel etc. as required.
34In gratings, frames, guard bar, ladder, railings, brackets, gates andsimilar works.
3540 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement :5 coarse sand) with joints 3mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortarWhite sand stone
36Kota stone slab flooring 25mm thick over 20 mm (average) thick base laid over andjointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :Area of each slab 2001 to 5000 sqcm
37Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275gm/m²
38Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover
39Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
40Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
41Extra for using Marble printed / Granite shade or dark shadetiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles.
42Extra for using size above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finished tiles in place of 300mm x 300mm size.
43Providing and fixing factory made uPVC door frame made of uPVC profile section having an overall dimension as below (tolerance ± 1mm) with wall thickness 2.0mm ± 0.2mm, corners of the door frame to be mitred and welded of plastic, galvanized brackets and stainless steel screws. The hinge side vertical of the frames reinforced bygalvanized M.S. tube of size 19 X 19mm and 1mm ± 0.1mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge Extruded section Profile size 48x40 mm
4430 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm ± 0.2 mm with inbuilt decorative moulding edging on one side. The styles and rails mitred and joined at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm ± 0.1 mm wall thickness. The lock rail made up of "H" section, a uPVC hollow section of size 100x30 mm and 2 mm ± 0.2 mm wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. "U" cleats. The shutter
45Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Green / Black Above 3601 Cm2 Slabs
46Stone work (machine cut edges) for wall lining etc. (veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid for separately) : White sand stone - Exposed face machine cut and table rubbed with rough backing. 40 mm thick
47Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand) including making the necessary chases in stone and holes in walls wherever required.
48Stone work, plain in copings, cornices, string courses and plinth courses,upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade.
49Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix :1:6 (1 cement : 6 fine/ coarse sand)
50Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : . 1:6 (1 cement : 6 fine/ coarse sand)
51Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
52Distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour complete. as per manufacturer"s specification. Two or more coats on new work.
53Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
54Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
55Random rubble dry stone Kharanja (soling) under floor.
56Providing laying, spreading and compacting stone aggregates of specific sizes as per Table 400-7 to Water Bound Macadam specification including spreading in uniform thickness; hand packing, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening (Table 400-8) binding materials to fill up the interstices of coarse aggregates, watering (with water browser) and compacting to required density, making necessary earthen bund to protect edges as per clause 404 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion complete. Crusher broken - Grade-II (63-45mm)
5711.38.3 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc (A) Category A Denated units to key into each other on four faces zigzag shape as per IRC SP 63:2004
58Add extra over rates of item No. 11.38, A to C if colored paver blocks are used
59S & Laying following size ‘B’ Class G.I. Pipe confirming to IS: 1239P-1 (1990) with accessories for laying earth conductor/ strip/ cable inground/ surface/ recess as required.125 mm dia
60Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work :80 mm dia. nominal bore
61Constructionofembankmentwithapprovedmaterialobtainedfrom borrowpitwithallliftsandleads,transportingtosite,spreading, gradingtorequiredslopeandcompactingbyvibratoryroller8-10 tonnetomeetrequirementoftable300-2includingcostof compensationforearthtakenfromprivatelandcompleteasper MoRT&H specification clause 305. (Lead taken upto 5 km)
62Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications and as per clause 2504 of MoRT&H Specification. With R.R. Stone/ bolder, weighing not less than 40 kg, thickness not less than 150mm, Specific gravity not less than 2.65.
63Supplying and fixing machine cut dressed 75 mm Pink sand stone (Bansi Paharpur) dasa/ coping wth ornamental shape having moulding and "PAN Shape" engraving as per required pattern with engraving depth of 5 mm (average) in single piece of length 90 cm to be laid on cement mortar 1:4 (12 to 20mm thick) including pointing with admixture of pigment matching with the stone shade.
64Ornamental Work Non SOR Item
65Providing and fixing Rectangular shaped bansi paharpur stone chatri with carving carving work having size of 3730 mm x 1500 mm base and height is 4490 mm on top of chatri5 no.of stone kalash placed of size 155 mm x 575 mm rectangular stone dome is placed on the top of stone columns having size of 230 x230 mmhaving height of 1800 mm are madeup of bansi paharpur stone.carving work is as per enclosed drawingand detail and instruction of engineer in charge.
66Providing and Fixing octagonal bansi paharpur stone chatri with carving work having size of 4300 mm x 4300 mm base and height of 7815 mm on top of chatri a stone kalash placed of size 1235 mm x 1500 m stone dome is placed on the top of stone columns having size of 421 x 418 mm having height 1640 mm are made up of bansi paharpur stone carving work is as per enclosed drawing and details and instruction of Engineer in charge
67Providing and fixing of overhead impact sprinkler full/part circle having radius of throw 11.3m - 13.7m & flow of 0.13 0.52 ltr/sec at an operative pressure of 2.5-4.0 kg/cm.sq. The sprinkler is impact driven rotary type having 3/4" bottom inlet. The sprinkler shall be having double weighted arm for slower rotation and increased distance of threw, self flushing inner trip, adjustable arm spring for low pressure operation, hooded bearing, distance controller deffuser pin. The body of sprinkler is of noncorrodible, heavy duty, ABS plastic. The sprinkler shall accept seven inter chargeble, color- coded nozzles. A 3/4" ASTM Raiser (6" long) with sadsle Tee is use to connect the pop up to pipeline. The body of saddle is made of vergin polypropylence in master batch UV stablised, reinforcement O-rings made of Delrin, galvanized nut & bolts and parallel female thread (Pressure tight)
68Providing& fixing of Gear Driven Rain gun sprinkler, grillo (Ajay (Indra)/Rain Bird/Premier-Full/ Part circle) with oscillating arm having radius of 41m and flow of 617lpm at an operative pressure of 5 kg/cm.sq, having 11/2" inlet. The body of sprinkler is made of aluminium alloy duty protected in its main parts by brass stainless steel and techno polymers. The sprinkler is equipped with Jet breaker and four different nozzles.
69Providing and fixing of self closing spring loaded quick coupling 3/4" hydrant (Drip"n"Drip /Whethermetic/ Premier); made of Aluminium alloy doly procted ints main parts by brass stainless steel and techno polymors & having self closing thermoplastic hinged lid, anti rotating device and with requirew no. of 3/4" key for quick coupling hydrant made up of Aluminium alloy ;doly procted. An electro galvanized MS saddle with 3/4" G.I Riser with galvanized nut & bolts and parallel female thread (pressure tight) shall be used to connect the quick coupling hydrant to the pipeline.
70Cast Iron bench of 1800 mm length, 900 mm width, 450 mm seating height, sides made ofcast iron. Seat and back shall be made of 10 strips of M.S. pipes 63 mm x 25 mm of 14 gauge with one M.S. Flat 25 x 10 mm welded at the centre, below and back of the seat and back rest. Spray painted with approved brand paint. (Minimum weight of each bench 105 kg)
71Flooring with white river pebbles of size 25 mm to 75 mm with bidasar green steps laid over cement mortar 1:4 in required pattern including finishing slearing of joints etc complete as per direction of Engineer in charge
72Stone work (machine cut edges) cladding of local avaliable well dressed slate stone in width from 150 to 300 mm and in length 300 to 450 mm with adjustable stainless steel cramps on rcc wall including required fasteners,stainless steel cramps etc complete as per direction of Engineer in charge
73Providing & Fixing HDP Dustbins of 40 Liter Capacity in existing CC foundation with MS pipe frames
74Sanitary Work
75Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. Diameter 900 mm
76Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thickness Diameter 900 mm
77Supply & lowering air line of 25mm dia, G.I. pipe "B" class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc.
78Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge.
79Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids
80Size 9 to 12 mm
81Size 3 to 5 mm
82Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids.
83Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work : 65 mm dia. nominal bore
84Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore
85Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work : 40 mm dia. nominal bore
86Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
8740 mm nominal bore
8865 mm nominal bore
89Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
90Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
91Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
92Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.
93Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete
94Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore
95Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
96Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall.15 mm dia nominal bore
97Providing, lowering, laying, aligning, fixing in position at and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade & PN-6 for potable water as per IS 4984 (amended upto date) in trenches complete with all accessories like Bend, Tee, Reducer, Stub end, End cap etc including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately. 75 mm dia
98Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 20 mm dia. nominal bore
99Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 32 mm dia. nominal bore
100Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately. 100 mm
101Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 178mm.
102Providing and fixing PTMT pillar cock of approved quality and colour 15mm nominal bore, 107mm long. Weighing not less than 110 gms.
103Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks
104Constructing masonry Chamber 120x120x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks
105Electrical Work
106Wiringoflightpoint/fanpoint/exhaustfanpoint/callbellpointas perPWDspecificationforelectricalWorkswithISImarked1.5sq. mmnominalsizeFRPVCinsulatedunsheathedflexiblecopper conductor1.1kVgrade(IS:694)and1.5sq.mmnominalsizeFR PVCinsulatedunsheathedflexiblecopperearthconductor1.1kV grade(IS:694)inrecessedISImarkedMMS(IS:9537P-III) vergin material PVC conduit & it"s all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal, 6 A switch , 3 pin ceilingrose/Lampholder/3pointConnector,3.0mmthickISI markedphenoliclaminatedsheet(IS:2036-1995),Al.alloy/ cadmiumplated iron screws20 mmcupwashers etc.allasper preapprovedbyEngineerincharge,makingconnections,testing etc.completeasrequired.ForspecificationofcopperConductor,PhenolicLaminatedsheet"s&Electrical/Wiringaccessoriesrefer Chapter E - 04, E - 05 & E - 07 .For additional technical parameters of products/ work, referAnnexure "A" attached with this BSR .
107Short point (up to 3 mtr.)
108Medium point (up to 6 mtr.)
109Long point(up to 10 mtr..)
110Wiringoftwincontrollight/fan/callbellpointasperPWD specificationforelectricalWorkswithISImarked1.5sq.mm nominalsizeFRPVCinsulatedunsheathedflexiblecopper conductor1.1kVgrade(IS:694)and1.5sq.mmnominalsizeFR PVCinsulatedunsheathedflexiblecopperearthconductor1.1kV grade(IS:694)inrecessedISImarkedMMS(IS:9537P-III) vergin material PVC conduit & it"s all accessories( J.B. , Bends etc.) , round tiles,2 nos. 18 SWG G.I. box with earth terminal,2 Nos 6 A two way switch,3 pin ceiling rose/ Lamp holder / 3 point Connector, 3.0mmthickISImarkedphenoliclaminatedsheet(IS:2036-1995),Al.alloy/cadmiumplatedironscrews20mmcupwashers etc.allasperpreapprovedbyEngineerincharge,making connections, testing etc. completeas required. Forspecification of copperConductor,Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter E- 04, E - 05&E - 07. . For additional technicalparametersofproducts/work,referAnnexure"A" attached with this BSR .
111Short point (up to 3 mtr.)
112Medium point (up to 6 mtr.)
113Long point(up to 10 mtr..)
114Wiringof3/5pin6amp.LightplugpointasperPWDspecification orelectricalWorkswithISImarked1.5sq.mmnominalsizeFR PVCinsulatedunsheathedflexiblecopperconductor1.1kVgrade (IS:694)and1.5sq.mmnominalsizeFRPVCinsulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessedISImarkedMMS(IS:9537P-III)verginmaterialPVC conduit & it"s all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal of required size,6 Aswitch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 -1995),Al. alloy/ cadmium plated iron screws 20 mm cup washers etc.allasperpreapprovedbyEngineerincharge,making connections,testingetc.completeasrequired.Forspecificationof copperConductor,Phenolic Laminated sheet"s & Electrical/ Wiring accessoriesreferChapterE-04,E-05&E-07.Foradditional technicalparametersofproducts/work,referAnnexure"A" attached with this BSR .
115On board
116Short point (up to 3 mtr.)
117Medium point (up to 6 mtr.)
118Long point(up to 10 mtr..)
119Sub Head - II - Drawing of Wires and Submains
120S&Ffollowingsizes(dia.)ofISImarkedMMS(IS:9537P-III) vergin material PVCconduitas per PWDspecificationfor electrical Works along with its accessories (IS: 3419 ) as requiredinrecess includingcuttingthewall,coveringconduitandmakinggoodthe same as required. All relative and latest acceptance tests reports by anyNABLaccreditedlabfortheconduitshallbesubmittedbefore execution&AllasperpreapprovedbyEngineerincharge.For additional technical parameters of products/ work, referAnnexure "A" attached with this BSR .MMS ( IS:9537 P - III ) PVC conduit
12120 mm
12225 mm
12340 mm
124SupplyinganddrawingFRPVCinsulated&unsheathedflexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire shouldbemadefrom99.99%puritycopper,class5strandingin acc. to IEC 60228 forlower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53,betteramperageratingasperVDE0298part4,,in existingsurfaceorrecessedPVC/MSconduit/casingcapping includingallasperpreapprovedbyEngineerincharge,making connections,etc.asrequired.OEMMusthaveitsowninhouse NABLlabsetupforalltestingfacilitiesforwires.Foradditional technicalparametersofproducts/work,referAnnexure"A" attached with this BSR .
1251x 1.5 sq.mm
1263x 1.5 sq.mm
1271 x 2.5 sq.mm
1282 x 2.5 sq. mm. + 1x1.5sqmm
1292 x 4.0 sq.mm+1x 2.5 sq. mm.
1302 x 6.0 sq. mm. + 1 x 2.5 sq. mm.
1314 x 6.0 sq. mm.
132Providing&Fixingof240/415VACMCBwithpositiveisolationof breaking capacity not less than 10 KA (B/ C tripping characteristic as pertypeofloadandsiterequirement)4KVimpulsewithstand voltage,asperPWDspecificationforelectricalWorkswithISI markedIS8828(1996)/conformingtoIEC60898-12002,IEC 60947-2,lowwattlosses,tripfreemechanisum,energylimitingofclass3asperIEC,minimumphaseterminationcapacityof 35sq.mm. , conductorlineload reversibility, label holding facility , IP 20contactprotectionandfittedwithexistingdistribution board/sheets,min.operation20,000upto32Aratingand10,000 upto63A,5000for80Aratingincludingmakingconnections, testingetc.asrequired..OEMshallhavesubmitNABL/CPRI/ ERDAaccrediatedlabtestreportsbeforeexecution&Allasper preapprovedbyEngineerincharge.Foradditionaltechnical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
133Single pole MCB
1346 A to 32 A rating
135Triple pole MCB
1366 A to 32 A rating
13750-63 A rating
138Four pole MCB
1396 A to 32 A rating
14050-63 A rating
141Providing & Fixing of 240/415 V isolator as per PWD specification for electricalWorkswithISImarkedIS:13947-III/conformingtoIEC 60947-3,suitableforAC22Autilizationcatagory,4KVimpulse withstand voltage,true contact indication,Red colour dolly / lever shallhavesinglemouldcoveringoverallpolesforoperation,two positiondinrailmounting,minimumphaseterminationcapacityof 35sq.mm. , label holding facility , IP 20 contact protection and fitted withexistingdistributionboard/sheetincludingmaking connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
142Double pole isolator
14330 A / 40 A rating
144Four pole Isolator
14563 A rating
146Providing & Fixing of metal clad industrial plug top & socket unit with pinandsleevetypecoppercontactonporcelain/bakelitebase insheetsteel(CRCA)powedcoatedenclosureasperPWD specificationforelectricalWorksconformingtoIs8623&IEC 61439-3(withoutMCB)including,allasperpreapprovedby Engineerincharge,makingconnections,,testingetc.asrequired .OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbeforeexecution&All as per pre approvedbyEngineerin charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure "A" attached with this BSR .
14720 A Double Pole(single phase Three pin )
148Providing&FixingofIK09recessed/surfacemountingheavyduty horizontaltypesheetsteelnotlessthen1.2mmthickDistribution boardasperPWDspecificationforelectricalWorksISImarked conformingtoIS-13032&IS-8623/conformingtoIEC61439-3. Phosphatised/powderpaintedcompletewithsuitablerating insulatedcopperbusbar,shortinglink,neutrallink,earthlink, connectingwireofsuitableratinganddinbar,maskingsheet, including making internal DBterminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated labtestreportsbeforeexecution&Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
149IP-43 Double door (single phase)
15012 Way (12 O/G +2 I/C)
151IP-43 Double door (Three phase)
15212 Way ( 36 O/G + 8 I/C )
153Providing&FixingofIK09ratingrecessed/surfacemountingheavy duty Vertical type sheet steel not less then 1.2 mm thick Distribution boardasperPWDspecificationforelectricalWorksISImarked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3 with provision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing,phosphatised,powderpaintedcompletewithinsulated suitable rating copper bus bar , neutral link, earth link and din bar, maskingsheet,includingmakinginternalDBterminationswith copperlugsandwithdetachableglandplate,testingetc.as requiredcompleteinallrespect.OEMshallhavesubmitNABL/ CPRI/ERDA accrediatedlab testreports beforeexecution &All as per pre approved by Engineer in charge.For additional technical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
154IP-43 Double door
1558 Way(8+24)
15612 Way(8+36)
157Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per PWD specification for electrical Works,made out ofunbreakableandfireretardantverginpolycarbonatewithbrass terminalsandcaptivescrews&silveralloycontacttipwithIP-20 rating,minimumwidthof1moduleswitchtoggle(PUSHPART) shouldnotlessthen20mm,includingallasperpreapprovedby Engineer in charge,making connections, testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
1586 A one way switch
1596 A two way switch
16016 Amp.1 Moduleswitch With LedIndicator
161Providing&FixingofmodulartypelockablefeaturesocketdulyISI marked(IS:1293)asperPWDspecificationforelectricalWorks,madeoutofunbreakableandfireretardantverginpolycarbonate withbrassterminalsandcaptivescrews&silveralloycontacttipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approvedbyEngineerincharge.Foradditionaltechnical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
1626 A3 pin shuttered socket
16316 A6 pin shuttered socket
164Providing&FixingoffollowingmodularaccessoriesasperPWD specification for electrical Works,made out of unbreakable and fire retardantverginpolycarbonatewithbrassterminalsandcaptive screws & silver alloy contact tipwith IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm,includingallasperpreapprovedbyEngineerincharge,making connections,testingetc.asrequired.Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
165RJ-11 telephone jack double two line
166RJ-45 computer jack with shutter
167T.V. coaxial socket
168Providing&FixingofmodulartypeStepFanregulatordulyISI marked(IS:11037)asperPWDspecificationforelectricalWorks,madeoutofunbreakableandfireretardantverginpolycarbonate withbrassterminalsandcaptivescrews&silveralloycontacttipwith IP-20 rating , minimum width of 1 module switch toggle( PUSH PART)shouldnotlessthen20mm,includingallasperpre approved by Engineer in charge,making connections, testing etc. as required.AllasperpreapprovedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
1695 step fan regulator 100 watt 2 Module
170Providing& Fixing offollowing size hotdip galvanized M.S. box of 18 SWG as per PWD specification for electrical Works, with earthing terminalinrecess/surfacesuitableformodularaccessoriesas required.AllasperpreapprovedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
1713 Module
1724/5 Module
17310/ 12 Module
17416/ 18 Module
175Providing & Fixing offollowing size polycarbonate modular boxes as per PWD specification for electrical Works, as per IS 14772-2000 in recess/ surface suitable for modular accessories as required.All as perpreapprovedbyEngineerincharge.Foradditionaltechnical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
1761-2-3 Module
1774-5 Module
1786-8 Module
17910/ 12 Module
18016/ 18 Module
181Makingofholeinwall(brick/stone)ofrequiredsizeforhousing exhaustfanandmakinggoodthesame,withcementplasteras required of following size:
182Up to 457 mm size
183Providing& Fixingof ISOCertified company made BEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanas per PWD specification for electrical Works,Conformtoalltheperformancerequirementslaiddownin IS:374-2019 includingall amendments,as applicable;&CarryBIS licensing(i.e.ISImarking)orQualityCertificationsuchasISO- 9001orabove.withdownrodupto30cmwithsecondarysupport safetycable(steelwire),cotterpinwith3x1.5sq.mmpvc insulatedflexiblecopperconductormakingconnectiontestingetc. as required.Appropriate OEM test certificate shall be submitted by contractor.AllasperpreapprovedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
1841200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
185P&FofHeavydutycapacitorstart,Doubleballbearing 900/1400 RPMsinglephaseISImarkedExhaust fan,IS:2312markedin existing opening including making connections testing etc. as required. Group - 1
186300 mm sweep(900/1400RPM)
187SITCofwall/freestandingfloormounteddustandverminproof compartmentalisedcubicalpanelasperPWDspecificationfor electricalWorks,madeoutofCRCAsheet.Otherparameters requiredas per point (a) ,(b), (c), (d) below:- (a)Thickness of sheet shallnot be less than 1.6 mm up to 600 mm length/widthofanycompartmentandbeof2.0mmabove600 mm.Loadbearingstructureshallbeof2.0mmthicksheet supportedbybaseM.S.channelifrequired.Sidewallsandcable alleycompartmentshavingboltedtypedoorswith/withoutdetachable extension type structure (b) panel shallbe duly treated for derustingin7tank process with dephosphatingand with powder coating of minimum 70 microns on both side of panel in desired shadeThe panel having PU/ Neoprene rubbergasketofnotlessthan3mmthickness,requiredhardware, separatedetachableglandplateM.S.basechannel(min75mm), hinged door with locking arrangement for equipment/switchgear. (c)Interconnection between bus bar and switchgears /cable shall be rigidlysupportedandmadeoutbyflexiblecopperwires(upto125 amp)andbysolidbusbar(>125amp).Alljoints/ interconnections of copper bus bar shall be dully tinned . Clearance betweenmainbusbarandrisers/metalpartsshallbeatleast10 mmadditionaltowidthofbusbarBusbarisinsulatedbyHeat Shrinkablesleeves.EarthandNeutralbusbarshallbehalfofthe size of phase bus bar. (d)onlyouterareaonallsidesshallbemeasured&paneltobe fabricatedonlyfromCPRIapprovedfabricator.Allasperdrawing preapprovedbyEngineerincharge.Foradditionaltechnical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
188SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/ Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts springwashersin existingpanelincludingbending ,cuttingin required shape and size and colour coding with heat shrinkable PVC sleeves.AllasperpreapprovedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
189Electrolytic grade Aluminium bus bar
190Providing&FixingofIP51(upto500)VrangeVoltmeteron existing panel as per PWD specification for electrical Works, making connectionbyPVCinsulatedcopperconductorwithPVCsleeves/ channel etc. Meter shall give true RMS measurments, acc. CI 1.0 or better,withfieldprogrammableprimary&sec.valuesPT(VT) primaryupto2000KV.Field-programmablehighandlowthreshold values,metershallcomplianceofIS13875&IEC61236.as required.OEM MusthaveBIScertificateand& shall have submitNABL / CPRI / ERDAlab test reportsbefore execution &All as per preapprovedbyEngineerincharge.Foradditionaltechnical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
191Digital type
192Providing&FixingofCToperateddirectreadingtypeIP-51AmperemeteronexistingpanelasperPWDspecificationfor electricalWorks,makingconnectionbyPVCinsulatedcopper conductor with PVC sleeves / channel etc. Ampere meter shall give trueRMSmeasurement,Acc.Cl1.0orbetter,Measuringcurrent range50mAto6A,withField-programmableprimaryand secondaryvaluesCTprimaryupto15000A,Field-programmable high and low threshold values as required. compliant to IS 13875, & IEC 61326. OEM Must have BIS certificate and&shall have submitNABL / CPRI / ERDAlab test reportsbefore execution &. All as per preapprovedbyEngineerincharge.Foradditionaltechnical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
193Digital type Confirming to IEC 62053-21
194Below 500 A
195Providing&FixingofBISapprovedCurrentTransformerasper PWD specification for electrical Works ,ISI marked as perIS 2705-1992/conformingtoIEC60044-1,withsecondaryterminalofCT shallbebroughtoutsuitabletoaterminalblockwhichshallbe easieraccessiblefortestingandterminalconnection,withall necessarysupportinexistingpanelincludingconnectionetc.as requiredCurrenttransformerResinCastWoundPrimary/Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burdenasspecified.ISF<=5,Cucrosssectionofsecondarywire 1.5sqmm(minimum),includingallnecessarysupportinexisting panel including connection etc. as required . All as per pre approved byEngineerincharge.Foradditionaltechnicalparametersof products/ work, refer Annexure "A" attached with this BSR .
196C T Class 1, Ratio 1600/5 to 2000/5, Burden 15 VA
197Providing & Fixing of ISO certified company made selector switch of 10 A for voltmeter (4 position ) using high grade engineering materialtointernationalstandardswithcamassemblyinsulationofglass filledpolyamidewithhightrackingindex.Forreliableandstable electrical and mechanical endurance double butt contacts with silver bi-metaloncoppershouldprovided.contactassemblyisof operating temp range -25 degree C to 55 degree C, frequency upto 10KHz.switchlifeunderstd.op.conditionsshallbemechanically minimum50000operations@300cycles/hourandelectrically 10,000 operations at 100% rated duty for 100 cycles/ hour including makingconnectionetc.asrequired.Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
198Providing&FixingofISOcertifiedcompanymadeCTlinked selector switch of 10 AforAmpere meter (4 position )using high gradeengineeringmaterialtointernationalstandardswithcam assemblyinsulationofglassfilledpolyamidewithhightracking index.Forreliableandstableelectricalandmechanicalendurance double butt contacts with silver bi-metal on copper should provided . contactassemblyisofoperatingtemprange-25degreeCto55 degreeC,frequencyupto10KHz.switchlifeunderstd.op. conditionsshallbemechanicallyminimum50000operations@300 cycles/hourandelectrically10,000operationsat100%ratedduty for 100 cycles/ hour , including making connection etc.as required . AllasperpreapprovedbyEngineerincharge.Foradditional technicalparametersofproducts/work,referAnnexure"A" attached with this BSR .
199Providing & Fixing of ISOcertified company made UL listed, IP 65 110/220 V, unibody LED Indicatinglamp IEC 60947 , CSA 22.2 with integral circuit, IP20 terminal block,Approx. bodydia for panel not lessthen20mm,lengthmin.50mm,frontLEDcoverdiamin.29 mm,contactmaterialphospherbronzeforLed,PCBcontactsshall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulationresistanceshallbe100Mohmat500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure "A" attached with this BSR .
200Red/yellow/Green colour
201Blue / white Colour
202SITCof IP 40 quick make and quickbreak4 polecurrentlimiting Mouldedcasecircuitbreaker(MCCB)madeofflameretardent& heatresistantmaterialhavingfollowingcurrentrating,shortcircuitbreakingcapacityat440/415V,50Hz;O/L&S/Csettingsasper PWD specification for electrical Works, conforming to IS/IEC 60947 P-2:2003withfrontfaceandcentralisedadjustable,tripfree mechanisum,truecontactpositionindicator,lineload interchangeability,designed for both horizontal &vertical mounting withoutanyadverseeffectonelectricalperformance,suitablefor operationupto55degreeandwithoutderatingupto40degree,pollution degree 3, having positive isolation capability, push(test) totrip,triptimelessthen10msunders/ccondition,Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock&rotaryhandle,includingmakingconnectionswithlugs& spreaders,etc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution. All as perpreapprovedbyEngineerincharge.Foradditionaltechnical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
203With Thermal Magnetic release
204up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
205400 Amp ,50 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu
206SupplyandfixingoffollowingaccessoriesforAircircuitbreaker (ACB)compatiblewithMAinACBOEMasperPWDspecification forelectricalWorks,conformingtoIS/IEC60947P-2:2003 including makingconnectionetc completein allrespect. OEM shall havesubmitNABL/CPRI/ERDAaccrediatedlabtypetest certificate before execution . All as per pre approved by Engineer in charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure "A" attached with this BSR .
207Shunt trip Release
208Under Voltage Release
209Earth Fault Module
210Providing &Laying P.V.C. / XLPE insulated &P.V.C.sheathed Un- armoured/Armouredaluminiumcableof1.1KVgradeasper PWDspecificationforelectricalWorksinexistingRCC/Hume/ Stoneware/PVCpipe/openduct/cabletrenchwithfillingof excavated earth in trench, on existing cable trays or on surface etc.includingmakingnecessaryconnection,testingetc.asrequiredof size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P – I (b)conductorshallhaveelectrolyticaluminiumconfirmingtoIS 8130,IS3975-1999forarmouringofcablesinarmouredcable items,IS5831forsheath,IS10810(Part0to64)fortesting procedures. (c)OEMMusthaveISO9001&14001certificationsforquality assuarance&itsowninhouseNABLlabsetupforalltesting facilitiesforcables.Appropriatetypetestcertificate/OEMtest reportshallbesubmitted.Allaboveasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR.
21110.0 Sq.mm x 4 core Armoured
21250.0 Sq.mm
2134 core Armoured
21495.0 Sq,mm
2153.5 core Armoured
216300.0 Sq.mm
2173.5 core
21816.0 Sq. mm
2194 core
2206.0 Sq. mm
2214 core
222Providing&LayingXLPEinsulatedasperIS:7098/II/85H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E)inexistingRCC/Hume/Stoneware/PVCpipe/open duct/cabletrenchwithfillingofexcavatedearthintrench,on existingcabletraysoronsurfaceetc.includingmakingnecessary connection, testing etc. as required of size as per points (a), (b), (c) mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I (b)conductorshallhaveelectrolyticaluminiumconfirmingtoIS 8130, IS 3975-1999for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c)OEMMusthaveISO9001&14001certificationsforquality assuarance&itsowninhouseNABLlabsetupforalltesting facilities forcables .All above as per pre approved by Engineer in charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure "A" attached with this BSR .
2233 core 120.0 Sq.mm
224Providing&makingheatshrinkabletypeindoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for11 KV / 33 KV cable with required components, preprationofcableends.Typetestreportshouldbeasper IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streightthrough joint inclusive thermal & dynamic shortcircuittest,humiditytest,soilfogtest.Crosslinkingshallbe done out side factorywith E- beam/ peroxide technology. Extrusion processshallbeinhouseOEMwithinsamevicinity.OEMtestlab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge includingtesting etc. as required of following sizes. All as per pre approved by Engineer in charge.For additional technicalparametersofproducts/work,referAnnexure"A" attached with this BSR . 11 KV End Termination Kit Outdoor type
2253 core 120/150/185 Sq.mm
226Supplyingandmakingoneendterminationwithheavydutybrass compressiongland (as per IS12943-1990)SIBG type, heavyduty aluminium lugs (as per IS 8309 -1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical WorksetcforfollowingsizeofArmouredPVCinsulated&PVC sheathed/XLPEaluminiumconductorcableof1100voltgradeas required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
2273.5 x 95.0 sq.mm
2284 x 6.0 sq.mm
2294 x 10.0 sq.mm
2304 x 16.0 sq.mm
2314x 50.0 sq.mm
2323.5 x 300.0 sq.mm
233Supply,Fabricating&installingfollowingsizesofpowdercoated perforated M.S. cable trays with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,crossmembersandotheraccessoriesasrequiredandduly suspendedfromtheceilingwithMSsuspendersincludingbolts& nuts , fastners, supports, painting suspenders etc. as required. All as perpreapprovedbyEngineerincharge.Foradditionaltechnical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
234300mm x 50mm x 1.6mm
235150mm x 50mm x 1.6mm
236Providing & laying of Double wall corrugated pipe confirming to IS : 14930P-1&2withHDPECouplerat1mtr.Depthbelowthe ground for laying cable including making the trench and back filling , compactionofearthasrequired(ExcavationofEarthtobepaid Extraasrequired.)offollowingOuterDia./Innerdiaasper IS:4984:1995.AllasperpreapprovedbyEngineerincharge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
237120 / 103.5 mm
238PlateEarthing as per PWD specification for electrical Works as per IS:3043 withcopper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3to 4 mtr. below the ground level with 20mm dia. G.I. "B" classwatering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm,BottomDia300to350mm.andHeight250to300mm.and embodyingthepipecompletewithalternatelayerssaltandcoke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required&mustrecordbyengineerinchargeduringsitevisitand ensuretoenterinmeasurmentbook.Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
239Supply&Layingfollowingsizeearthstripinhorizontalorvertical runinground/surface/recessincludingriveting,soldering,saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip)/GI(forGIStrip)nutbolt&springwasherspacedat50cm makingconnectionetc.asrequired.Allasperpreapprovedby Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
24025mm x 5mm copper strip
24125mm x 6mm G.I. ( Hot Dipped) Strip
242Supply & Laying following size earth wire in horizontal or vertical run inground/surface/recessincludingriveting,soldering,saddles,makingconnectionwithGI/Cuthimbleetc.as required. Allas per preapprovedbyEngineerincharge.Foradditionaltechnical parametersofproducts/work,referAnnexure"A"attachedwith this BSR
2438 SWG G.I. ( Hot Dipped) Wire
244Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
245High Power LED Flood Light 120W
246Providing & Fixing of IP 20 boxmade outfrom 1.2mm thick CRCA sheet steel withdepthof minimun 30 mm and finishedwith powder coating andsuitable for mounting LED tubeincludingside covers, holders,internalwiringtoilluminatethesinglesidedconnection LEDtube. ( Withouttube). All asperpreapprovedbyEngineer in charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure "A" attached with this BSR .
247Suitable for 4" LED Tube shape fixture 2 X 18/20 W
248Providing&Fixingofcapacitorstart,copperwound,metalbody,metalbladethreespeedwallmountingfanoffollowingsweepwith the help of anchor bolts including making connection testing etc. as required. OEM shall be an ISO certified company.Appropriate OEM testcertificateshallbesubmittedbycontractor.Allasperpre approvedbyEngineerincharge.Foradditionaltechnical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
249400 mm sweep(Oscillating type)
250Supply,Installation,TestingandCommissioningofWallmounted ISO9001:2015&14001orhigherlevelcertifiedcompanymade Communicationenclosure(Rack)ofMinimum500MMDepthwith made from CRCA & hot dip powder coated, front sturdy sheet steel framefoldedfromonepieceandweldedwithminimum5mm toughened glass door,Vertical Mounting Rail 1.6 MM with "U"Marking ,withAllroundprotectivechannelonthedooraperture,lock integratedonfrontdoor,topandbottomcoverwithcableentry provisionwithglandplates,integratedsidewalls,2pairof19" angleswithwall mountingprovisiononwall.Accessories like: 1No of 19" 1U Horizontal Cable manager, 2 No of 90 cfm 230V AC Fan with1mtslongcable,mountinghardware,1Noof19"1U, mountablesocketstripswith6nosof5Auniversalsocketswith2 mtslongpowerchordforsupplyingpowertoswitches,fansetc alongwithearthcontinuitykit,indicator,mouldedpowersupply cable.fixingonwallwithfastnerofsuitablecapcityetcasrequired completeinallrespect.AllasperpreapprovedbyEngineerin charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure "A" attached with this BSR .
25112 U wall mounted Enclosure
252Providing&FixingofISOcertifiedcompanymadeonloadchange overswitch,fronthandleoperated,fourpole415VasperPWD specificationforelectricalWorksconformingtoIS/lEC60947-3: 1999 including connections , testing etc. as required .in the following rating.Appropriatetypetestcertificate/OEMtestreportshallbe submitted.AllasperpreapprovedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . Open execution type
253400 A
254Supplyinstallationtesting&CommissioningofstarratedCopper wound distribution Transformer ( All the distribution transformer must bestarratedaspernotificationof(BEE)ministryofpower, GoverenmentofIndia)offollowingrating11/0.433KVDelta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & lossesas defined as perIS1180partI2014.includingstandardaccessorieslike conservator,silicagelbreather,Bucholzrelay,radiator,fins,HT cablebox<cableboxes,Off-LTC(+5%to-10%@2.5%) temperature rise of 40 degree C in oil / 45 degree C in winding , ISI markeddrainvalve,DialtypeTemperaturegauge,firstfillingof transformeroilasperIS:335-1953,Epoxybasedpaint,including carryingofpre-commissionTesting&ChargingofTransformer completeinallrespect.NABLaccredeated/CPRI/ERDAlab testingreportswithOEMcertificatemustsubmittedtoengineerin charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installaion must be certifiedfromElectricalInspectorateofficeasperIndianElectricity rule, CTL testing charges & Inspection charges shall be reimbursed by the department to the contractor as per actual expenditure. All as perpreapprovedbyEngineerincharge.Foradditionaltechnical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
255250 KVA
256Supply&InstallationofD.P.StructureWithAIRBREAKSWITCH having following specifications:- All as per pre approved by Engineer incharge.Foradditionaltechnicalparametersofproducts/work , refer Annexure "A" attached with this BSR .
257DP:Doublepolestructureon2noISMB150x100mm,10mtr high using 7 no MS channel each of size100 mm x 50 mm x 2500 mmcompleteinallrespectwithnuts,springswashers,clampsas required.
258GO:Offloadtypegangoperated3-poleverticalflutetypeswitch suitablefor11KV;400A,3-ø,centralpostrotatingdoublebreak isolator complete with MS hardware , copper moving & fixed contact ,assemblyof9nospininsulator,GIpipeofsuitablelengthfor operation.
259DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators
260LA:3piecenonlinearresistortype.lightingarrestorofapproved make suitablefor 3wire,11kvOverhead linewith ratedvoltageof 9kv rms & nominal discharge current rating of 5 ka & complete with galvanizedclampingarrangementGIbolts,nuts,washeretcas required.
261JUMPERS:3no11kvacsrconductorsmountedonpintype insularorsasrequired.6.GENERAL:Thegoshallbeoperatedby handoperatedliverproperlyearthedwithprovisionforlocking mounted at 3’
262Supply and fixing of piller box as per DISCOM / PWD specifications madeof2mmthickpowdercoatedCRCAsheetof415volts3 phase 4 wire triple pole and neutral type, complete in all respect as required. Including knife switch of 400 amp. rating , HRC fuses with copperonepieceUcontactsbase,brassstudsandnuts,copper busbar for main and interconnection, MS angle frame of 50 x 50 x 6 mm grouted with C.C. of M-10 grade to achieve the height of 1.5 feet abovetheroadlevelsuitableforfouroutgoing.Allasperpre approvedbyEngineerincharge.Foradditionaltechnical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
263Providing,installation,testingandcommissioningofCentrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating atsynchronisedspeedof3000RPMwithrequisiteMOCimpeller, primingfunnel,cock,suitableflangesatsuctionanddeliveryside. Pump shall have common shaft for pump and motor. Motor shall be suitableforworkingon415V±10%,3Ph,50HzA.C.Supply. Motor shall be TEFC type and Pump set shall be suitable for working atvariousdischargeandheadrequirementsasperscopeofwork. PumpshallbeerectedonC.C.foundation/crosschannels/RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work anddirectionofEngineerinChargeoffollowingpowerrating, suitable for prescribed duty conditions mentioned in TD. Centrifugal Monoblock Pump set (Single Stage)
2642.2 KW (3.0 HP)
265OctagonalMSPolesmadeofS-355JOgradesteelsheet,folded lengthwisetoobtainedOctagonalshape,havingsinglelongitudinal seamweldandhotdippedgalvanisedinternally&externallyin accordance with IS 2629. (See Table P -01 for specs.)
2667 Mtr.
267Providing&FixingofIK07IP66protectedLEDStreetLight Luminaireonexistingbracket/pole.Fixturemadeofpowdercoated single piece pressure die cast aluminum LM6/ ADC12 material with heatdissipationfinsonhousingwithUVstabilizedPC/Toughened Glasscover(UVstablzationreportsubmittedforUVcover)and secondarylensoneachLED&shouldbeSMDtype.TheSystem level Luminaire efficacy >=120 lm/ wtwith High Power LEDs is to be usedandpotteddrivermustbepotted&hasauniqueBISR numberwithInputVoltageAC120to270VACwithHighvoltage Cutoff@>=300VACandAutoresettingSafety,InputFrequency 50Hz±3%PowerFactor>0.95driverEfficiency>85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <1000mA shown in LM79 report. The luminaireshall be BIS certifiedandT.C.certified.LifeExpectancyEqualormorethan 50000burninghrswithMinimum70%lumenmaintened,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall bemin=4KVinternalandmin10KVexternal.drivershouldbe Phase to phaseprotectionof 440 V for 4Hrs. Manufactures Word Mark/NameEngraved/Embossingondiecasthousingtoallow traceability/authenticity.FixtureshallbeASPERIS10322 Complianced. OEMMusthaveitsowninhouseNABLlabsetupforalltesting facilitiesforLEDfixtures.(LM79/LM80)Certificate/reportwith liable warranty of product/accessories from OEM shall be submitted.AllasperpreapprovedbyEngineerincharge.Foradditional technicalparametersofproducts/work,referAnnexure"A" attached with this BSR .
268LED Street Light fixture 30 Watt
269Providing&Fixingof240/415VResidualcurrentcircuitbreaker (RCCB)asperPWDspecificationforelectricalWorkswithISI marked (IS:12640-1) / conforming to IEC 61008 -1 , rated conditional s/ccurrentof10KA,trulycurrentoperatedandshalloperateon CBCTmechanisum,provisionforpadlock,min.operation10,000 upto63Aratingand5000for100Arating,minimumphase terminationcapacityof50sq.mm.rigidwire,IP20contact protectionwithexistingdistributionboard/sheetincludingmaking connections, testing etc. as required.OEM shall have submitNABL / CPRI/ERDA accrediatedlab testreports beforeexecution &All as per pre approved by Engineer in charge.For additional technical parametersofproducts/work,referAnnexure"A"attachedwith this BSR .
270Two pole 100/300mA sensitivity
27163 A rating
272S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate battery with BIS approved make .luminaire should be secondary optic lenses for better distribution with delivered efficacy of > 100 Lumen perwatt.Bidder shall have in house R&D Laboratory which is recognised by ministry of Science & Technology department, Govt. OfIndia/ NABL Bidder shall have inhouse pole & luminaire manufacturing facility. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab. Guarantee for total system is two years .Note: All the above should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton.
27330 W LED Post Top Fixture
274Providing&FixingofISOcertifiedcompanymadeIK10IP65 protectedTop/BottommountedLEDPosttopLightsystem.Fixture madeofpowdercoateddiecastalluminiumhousingwithUV stabalizedPCdiffuser.TheSystemlevelLuminousefficacy=90 Lumen/W.SMDLEDsistobeused,SystemCRI>70,CCT: 3000/4000/6500K.Theintegralelectronicdrivermustbepotted& has a uniqueBISR number must bepotted&has a uniqueBISR numberconstantcurrentandInternal/externalsurgeprotection deviceofmin. 4KV(L-N)and efficiency> 85%,PF>0.9, THD<20% andinputVoltagerangeof90-270VACat50Hz.Systemlifeof 30000Burninghourswith70%ofInitialLumensmaintainedLightoutput in Cool white or Warm White Colour as per engineers choice. drivercurrent<1000mAshowninLM79report.Fixturemustbein compliance with BIS Standards and T.C . Certificate complete in all respect.OEMMusthaveitsowninhouseNABLlabsetupforall testing facilities forLED fixtures.(LM79/LM80) Certificate/ report withliablewarrantyofproduct/accessoriesfromOEMshallbe submitted.AllasperpreapprovedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
275Compact Solar LED Street Light - 35W(MONO) 18V/ 12.8V9Ah/12W
276Provide and fixing of LED POST TOP fixture made form Die cast aluminum graphite grey powder coated finished housing. Polycarbonate opal diffuser. Low power Warm White (WW) LEDs connected in series and parallel combination with better Heat dissipation arrangement. Highly efficient constant current electronic driver having operating voltage range from 140- 280 Volt AC;provided with high voltage, open and short circuit protection.Suitable for 60mm OD pipe entry with fixing bolts. Degree of protection IP65 LED Make – Nichia/Philips/Osram/Cree or Equivalent LED color temperature range form 3000-5700°K ±300°K. Voltage surge protection 5KV. the luminaire should bear 5 KV surge protection,PF >=0.9(HPF) and total harmonic distortion of THD(I) <10% voltage range of 140-280V. Manufacturer to provide certificate of LM 80 LM 79 form source manufacturer and should have in house adequate testing facilities ( approved by Govt. of India ministry of science and technology/NABL) . Approved Luminaire Make: Philips, Bajaj, Keselec.
277LED POST TOP 65W
278Façade Lighting , Wall Waser,Fixtures
279Supply, Installation, Testing and Commissioning of Spike Light of7 Watt and10 Degree Beam Deflection and Colour Temperature 3000 Kelvin, Body Material: ?Aluminium, Push button similar to the Model 919215850753_1_1 of Make? Philips
280Supply, Installation, Testing and Commissioning of Spike Light of12 Watt and10 Degree Beam Deflection and Colour Temperature 3000 Kelvin, Body Material: ?Aluminium, Push button similar to the Model 919215850753_1_1 of Make ?Philips
281Supply, Installation, Testing and Commissioning of IP44 9W wall washer light Light color 3000K, Total lumen output fixture 550similar to the EAN/UPC - product 8727900078251 of Make? Philips
282Supply, Installation, Testing and Commissioning of IP44 5W Foot Light Material: Metal, Color: Anthracite Surface LED Step Light Warm White 2700k Watts: 5W, Lumens: 165lm IP44 fixture ideal for gardens, Metal body with a classy matte finish. Moisture-proof not waterproof. Philips 31436 LED Garden Step Light Product Specification - ?Color: Anthracite Grey Material: Aluminium Dimension(mm): 201*98*35 Lamp Base: LED.
283Horticulture Work
284Preparation of mounds of various size and shape by available excavated/surplus/earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc.lead upto 50 meters and lift upto 1.5 m as per direction of officers in charge.
285Supplying and stacking good earth at site of work. Note: 1) Loading, unloading and carriage to be paid extra as per actual lead. 2) Earth measured in stacks will be reduced by 20% foe payment
286Supply at site of work well decayed farm yard manure, from any available source, approved by the engineer in charge including screening and stacking
287Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately)
288Providing, lowering, laying, aligning, fixing in position at and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade & PN-6 for potable water as per IS 4984 (amended upto date) in trenches complete with all accessories like Bend, Tee, Reducer, Stub end, End cap etc including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer 110 mm dia
289Providing, lowering, laying, aligning, fixing in position at and jointing at all level/ depths HDPE Stub End (Long neck pipe end) of PE-100 grade & PN-6 (moulded/ machined) for potable water with MS galvanised flange as per to BS-10 table D/IS:1538 within pipeline in trenches complete including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.110mm HDPE Stub End (LNPE) with MS Galvanised Slip on flange Suitable for connecting Valve of 100mm dia
290Grassing with "Carpet" grass (selection no. 1) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed.(The good earth shall be paid separately)
291In rows 5 cm apart in either direction
292Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm.
293Digging holes in all kinds of soil and refilling the same with the excavated earth mixed with well decayed farm yard manure (cost of well decayed farm yard manure to be paid separately).
294Hole 0.6 m dia and 0.6 m deep
295Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year.
296Providing and fixing of RCC pre cast tree guard consisting of four panels of size 1800mm (Height) X 600mm (Width) X 35mm (thickness); Size of opening: 100mm X 100mm. All the panels shall be manufactured with monolithic legs of size 50 x 35 mm; the legs of the panels shall be 0.5 m below ground level. All the four Panels shall have a space for display of Name etc. preferably at middle level. RCC panels to be manufactured with M-30 grade of concrete using vibro-compaction process using jointless FRP moulds so as to achieve shuttering finish. RCC panels are to be suitably reinforced to promote long use and to prevent damage during handling, transportation & erection as per drawing & specifications.
297Supply and planting following species best quality container grown healthy trees of 2 mt. min. height, well established & free from disease at site in 0.90 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.
298Plumeria alba ( Champa)
299Bauhinia variegata
300Cassia fistula
301Callisteomon viminalis
302Largerstomea speciosa
303Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 600 mm min. height shurbs at site in 0.45 m dia holes, 0.45 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.
304Rhaphis excelsa with 3-4 suckers ( Lady Palm)
305honenix sylvertris ( Date Palm)
306Supply and planting following species best quality container grown healthy trees of 3 mt. min. height, well established & free from disease at site in 1.20 m dia holes, 1.20 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.
307Jacaranda mimosifolia
308Delonix regia
309Royal palm
310Cassia Siamea
311Mimusops elengii
312Pond Conservation
313Silt clearance of drains, channels and canals with lift 1.5 Mtr and lead up to 50 Mtr
314Carriage of Materials by mechanical transport including loading, unloading and stacking ::Sand, bazri, ballast, kankar upto 5 km
315Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.
316Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm
317Survelliance System
318Supply, Installation, Testing & Commissioningof Reliable & Secure Bullet Camera, Resolution upto 5 MP , Quad stream with each stream support H.265 , H.264 compression ,fixed focallens 3.6mm or better ,,1/2.8" CMOS sensor Min illumination : Color 0.05lux @ F1.2(AGC ON) ;   B/W 0 lux @ IR ON , Shutter Speed : 1/5 ? 1/100,000 s , Video Compression : H.265 , H.264 , frame rate : Main stream upto 5MP@25fps , substream upto 2MP@25fps , third and fourth stream upto VGA@25fps . Edge analytics :Motion Detection, Perimeter Intrusion, Line Crossing, Stationary Object, Face detection (deep learning) ,Cross counting , Pedestrian detection ,Inbuilt IR LED , IR distance upto 30 mtrs ,IP 66 , POE ,ONVIF profile S & G . UL , CE ,FCC Certified. Make: Axis/ Pelco/ Impulse/ Tyco/ Avigilon/ Mobotix
319Supply, Installation, Testing & Commissioningof Reliable & Secure 64 channel NVR upgraded to 128 Channels , ONVIF profile S & G , recording bandwidth 640 Mbps , output interface 1 HDMI (up to 4K), 1 VGA, Alarm in/out :16chin / 4chout , 1 X RJ45 ethernet , iOS smartphone support , 8 HDD support, each HDD slot support upto 8 TB HDD , RAID support , 1x3.0 USBfor backup/upgrade, 2x 2.0 USB for mouse, AI Support ,UL,CE,FCC certified. . Make: Axis/ Pelco/ Impulse/ Tyco/ Avigilon/ Mobotix
320Supply, Installation, Testing & Commissioning ofSurveillance of Hard Disk 6 TB
321Network Switch
32224 port switch fully managed Core switch with 20 Nos of 20 100M/1G SFP Port , 4 Nos of GbE RJ45/SFP Combo Port , 4 Nos of 1G/10G SFP+ Port ,1 X Console , Switching bandwidth 128 Gbps , 32K MAC address support , Support L2 feature STP, RSTP ,MSTP . Support 802.1Q VLAN , port based VLAN , 4K VLAN entries , MAC based VLAN , IP subnet based VLAN .Device Management system - topology view , floor view ,map view , dashboard , traffic monitoring , cable diagnostics Support IEEE 802.3ad LACP . L3 features - static routing , DHCP server. Make: CISCO/HP/Juniper//Brocade/Camera OEM
323Supply, Installation, Testing & Commissioningof 24 port L2 Managed switch having port density 24 Nos of 10M/100M/1G RJ45 Port POE /POE+ ports , 2 Nos of GbE RJ45/SFP Combo Port , 1X console port , Available POE power 370 W , 52 Gbps switching bandwidth , 8K MAC address support , Support L2 feature STP, RSTP ,MSTP . Support 802.1Q VLAN , port based VLAN , 4K VLAN entries , MAC based VLAN , IP subnet based VLAN . Support IEEE 802.3ad LACP . L3 features - static routing , DHCP feature , Device Management system - topology view , floor view ,map view , dashboard , traffic monitoring , cable diagnostics.CE,FCC certified. Make: CISCO/HP/Juniper//Brocade/Camera OEM
324Passive- Fiber Component
325Supply, Installation, Testing & Commissioning of Optical Cable 6 Core
326Supply, Installation, Testing & Commissioning of LIU 24 PORT Rack Mount - Loaded
327Supply, Installation, Testing & Commissioning of LIU 12 PORT Rack Mount - Loaded
328Supply, Installation, Testing & Commissioning of PATCH CORD
329Passive- Copper Component
330Supply, Installation, Testing & Commissioning of CAT6 UTP 23AWG Solid:305M
331Supply, Installation, Testing & Commissioning of Face Plate+Back Box+Jack
332Supply, Installation, Testing & Commissioning of CAT6 PATCH CORD:1M
333Supply, Installation, Testing & Commissioning of CAT6 PATCH CORD:3M
334Passive- Networking Rack
335Supply, Installation, Testing & Commissioning of9U rack with all accessories
336Supply, Installation, Testing & Commissioning of 22 U rack with all accessories
337UPS
338Supply, Installation, Testing & Commissioning of UPS for back up of 30 Mins for Edge Switches and Camera
339Supply, Installation, Testing & Commissioning of UPS for back up of 30 Mins for Centralised Control Room for CCTV
340Supply, Installation, Testing & Commissioning of 42"" LED Screen
341Road Work
342Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 50 metres, stacking serviceable and unserviceable materials separately as directed by Engineer.
343Bituminous courses
344Granular courses
345Earth work in excavation for roadway, including trimming bottom and side slopes in accordance with requirement of line, grades and cross sections, including disposal of surplus material with all lift and lead upto 1000 metre as per MoRT&H specification clause 301.
346In all type of soil
347Providing, laying, spreading and compacting of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per MoRT&H specification clause - 401 including all material, labour, machinery, lighting, guarding and maintenance of diversion.Grading - I Material
348Providing, laying, spreading (with paver finisher only) and compacting wet mix macadam (WMM) base course comprising of graded stone aggregate and granular material conforming to MORT&H specifications (Table 400-II) in layers of equal compacted thickness each consolidated, including pre-mixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tippers to site, laying in uniform layers in base course on a well prepared sub-base/ base course and compacting with power vibratory-roller to achieve the desired density complete as per MoRT&H specification clause - 406 including all material, labour, machinery, lighting, guarding and maintenance of diversion.
349Providing and applying primer coat over prepared surface of granular base with bitumen emulsion as per IS : 8887 and approved quality @ 0.6 kg/sqm with the help of spray set fitted on bitumen Container (boiler) after cleaning the surface including removing of binding material and other foreign matter with wire brushes and small picks, sweeping with brooms or soft brushes and finally dusting with old gunny bags and compressed air to receive bituminous treatment complete as per clause 502 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.
350Providing and laying 50-75 mm compacted thick design mix (approved by Engineer) Dense Bituminous Macadam on prepared surface with specified graded crushed aggregates as per Table 5009, 500-10 with bitumen binder set (including Cost of anti stripping compound Minimum 1%in Lime/Cement as per design wherever required) for base/ binder course including loading of material with F.E. loader, heating and mixing of stone aggregate, filler and bitumen in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted with electronic sensor control as per clause 504.3.5 to the required level and grade, compacting by power rollers and vibratory rollers or 150 to 250 KN pneumatic tyred roller with TP = 0.7 Mpa to achieve the desired density (approximately 2.3 tonne/cum) complete as per clause 507 of MoRT&H specification but excluding primer/tack coat, including all material, labour, machinery, lighting, guarding and maintenance of diversion.
351Grade-II with Bitumen VG-grade 30 @ 4.25 %, lime filler @ 2% (percent by weight of total mix)
352Providing and laying 30-45 mm compacted thickness BituminousConcrete as per design mix (approved by Engineer) on preparedsurface with specified grade stone aggregate as per Table - 500-18 with bitumen for wearing course including loading of aggregate withF.E. loader and hot mixing of stone aggregate and bitumen(including Cost of anti stripping compound Minimum 1%inLime/Cement as per design wherever required) in computerised hotmix plant, transporting the mixed material by tippers to paver andlaying with paver finisher fitted with electronic sensing device (as perclause 504-3.5) to the required level and grade and compacting bypower rollers and vibratory rollers or 150 to 250 KN pneumatic tyredroller with TP = 0.7 Mpa, to achieve the desired density complete asper clause 509 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversionbut excluding primer/tack coat.
353Grade-II with Bitumen VG-grade 30 @ 6% (percent by weight of total mix)
354Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 3 metre long and size 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing including all material, labour. 80 mm x 60 mm rectangular
355Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide stripes, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and confirming toIRC-79 and the drawings.
356Providing and fixing precast dense cement concrete M-20 Grade(Vibro-pressed) drain section block of different size as per approved drawing, design and strength as per IS:2185 (part I) of grade "D" (5.00 N/mm2) proper quality of additive/admixture like plasticizer etc. added to produce high quality and durable drain section Blocks of "L" shape "U" shape etc. over 50mm thick CC M15 base course with fixing and joining with C.M.1:4 in proper grade and level complete in all respect. (cost of earth work, steel & welded mesh shall be paid extra). 60 MM Thick
357Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing complete as per clause 601, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.
358Providing and fixing of precast concrete interlocking tiles of desired shape of M 30 grade manufactured from fully computerized automatic stationery hydraulic vibrio pressed machine and fully computerized automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 60mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer in charge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. Tensile splitting strength, abrasion and braking load etc. as per BS 6717:2001, Grey cement.
359ProvidingandfixingprecastcementconcreteM-20grade(Using mechanicalConcreteMixer)kerbstonetopandbottomwidth115 and 165 mm respectively, 250 mm high on 150 mm thick PCC M-10 grade foundation as per design, including fixing at site as per clause 408ofMoRT&HSpecificationincludingallmaterial,labour, machinery, lighting, guarding and maintenance of diversion.
360Solar Panel
361Supply, installation, testing and commissioning of MNRE approved Grid tiedSolar Panels with inverter, meter, cable etc. suitable for Rooftop installationas well as Utility Scale Solar Power Projects with 25 years of LinearGeneration warranty. Work includes designing of solar panel area and MSframe and foundation on ground/roof of Pump house or CWR, showingarrangement of panel in available space, installation of PV module on MSframe as per approved design and drawings. Mounting structure shall besuitably designed to withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peakefficiency of >98%. Connect up to multiple strings PV arrays, Easy & fastconnection, Built-in string-level monitoring, IP65 protection level, Wi-Fi /internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge.Note: There shall be 5 year service warranty for panel, inverter, meter, cableetc. and suitable provision shall be included in tender document.
362Solar panels up to 10 KW at a single location.
363PlayGround
364Providing and Installation of Multipurpose kids play equipment includes Slides, walking, Climbing, hanging, etc. activity in a single tower. FRP Outdoor Kids Play Equipment, Size: 7.4 X 4 M, Capacity: 8-10. All Steel Components are APL Apollo brand I.S.I. mark pipes with powder coated with anti-rusting treatment and all FRP components are paint by high quality PU paint in 03 layers. Complete in all respect as per directions of Engineer incharge.
365Providing and fixing Steel Merry Go Round equipment for kids park made up of Galvenized steel finish, Size: 2 M Dia, Capacity: 4-5 kids. Complete in all respect as per directions of Engineer IN-charge.
366Providing and fixing Iron FRP Double Seesaw equipment for kids park Play Area 4.0 X 2.5 m Loading Capacity 100-200 Kg. Complete in all respect as per directions of Engineer IN-charge.
367Providing and fixing Iron S Shape Climbers Shape Climber, Capacity: 10 Children. Dimension 3.5 x 2 x 2.1 m. (11.4 x 6 x 7 ft.). Complete in all respect as per directions of Engineer IN-charge.
368Fountain
369Providing and Installation of Multicolor Floating Water Fountain, Made up of brass or SS, Nozzle Type Finger Jet Nozzle, Multidimension Nozzle, Nozzle dia 10-30 mm, Fountain Height: upto 25 Feet, Electric motor of 4 HP of frequency 50-60 Hz. Complete in all respect as per directions of Engineer incharge.
370Providing and Fixing Floor Recessed Grid Assembly with fountain Nozzle and LED lights, Body Material: Stainless Steel 304 grade with stainless steel finish and LED lighting with colour: RGB/WWW/CW/R/B/G. Complete in all respect as per directions of Engineer incharge.
371Primary Treatment
372Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge.
373In cement mortar
374Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer
375Cement Concrete Grade M-15 and above and PCC blocks
376Dismantling Stone Masonry
377Dry rubble masonry
378Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which approach is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion).
379Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level :
3801:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size).
381Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement:
382M-25 Grade Concrete (1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) -As per design mix)
383Random rubble masonry with hard stone in foundation and plinth :
384Cement mortar 1:4 (1 cement : 4 coarse sand)
385Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in :
386Cement mortar 1:4 (1 cement : 4 coarse sand)
387Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 15 mm cement plaster on the rough side of single or half brick wall of mix :
3881:4 (1 cement : 4 fine/ coarse sand)
389Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
3901.00mm thick with zinc coating not less than 275gm/m²
391Supply, fabrication, fixing and Testing of stainless steel (SS-316) Manual Coarse Bar screen with flat bar 50mm X 10mm, Spacing of bars 50mm suitable for mounting in channel of specified size with inclination not more than 45 degree and a movable covered containers of 1 cum capacity complete in all respect as per technical specification and the direction of the Engineer. Manually Raked Coarse Bar Screen with 50 mm clear opening for following PEAK FLOW and upto 3m channel depth.
3923.1 MLD to 5 MLD
393Construction of RCC chamber for different type of Drain including earthwork excavation, 100mm PCC M10 (1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as leveling course, RCC M20 grade (1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) for base slab, side wall , including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer.
394Chamber-4 (1200 x 1200 x 1500 mm)
395Supply, Installation, Testing and commissioning of CI Open Channel SluiceGates,Manuallyoperated,RisingSpindletypesuitablefor mountinginbetweentwo parallelwallsof an OpenChannel. Water sealingshallbeprovidedattwoverticalsidesandbottomsideof gateaperturebymeansofrubberseal,mountedongateslideand having forced contact with gate aperture. The gate shall be designed in such a manner, so that it can be operated at 2 meter head. Gate frame&ShutterofCIGradeIS210FG260,HeadStockIS210 Grade FG 260, Hinge Pin SS ASTMA276, Yoke IS MS 2062, Flush BottomSealSupportBarofSSASTMA276,StemOperatingNut ASTM A276., Duly tested for tensile strength, Chemical testing and testedShoptestedforoveralldimensionsasperapprovedGA drawing complete in all respect as per specification and direction of Engineer for following PEAK FLOW up to 3m channel depth.
396Up to 5 MLD
397Supply, fabrication and fixing of stainless steel (SS-316) CoarseBar screen (mechanically raked) with flatbar 50mm X 10mm Spacing of bars50mmsuitableformountinginchannelofspecifiedsizewith inclinationnotmorethan75degreecompleteinallrespectasper technicalspecificationandthedirectionoftheEngineerfor following PEAK FLOW and upto 3m channel depth.
3985 MLD to 10 MLD
399Chlorination Package
400Cost of E&I Systems
401Chattri
402Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
403Carriage of Materials by mechanical transport including loading, unloading and stacking - for 5 Km. (Stone, boulders, gravelly material)
404Providing and fixing double scaffolding system (cup lock type) on the exteriorside,uptosevenstoryheightmadewith40mmdia.M.S. tube1.5mcentretocentrehorizontal&verticaltubesjoiningwith cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps andM.S.staircasesysteminthescaffoldingforworkingplatform etc.andmaintainingitinaserviceableconditionfortherequired durationasapprovedandremovingitthereafter.Thescaffolding system shall be stiffened with bracings, runners, connection with the buildingetcwhereverrequiredforinspectionofworkatrequired locationswithessentialsafetyfeaturesfortheworkmenetc. complete as per directions and approval of Engineer-in-charge .The elevationalareaofthescaffoldingshallbemeasuredforpayment purpose .The payment will be made once irrespective of duration of scaffolding. (To be used for maintenance work judicially . necessary deduction for scaffolding in the existing item to be done.)
405P & L Lime Surkhi Plaster lime surkhi mortar 1:2 (1 Lime : 2 Surkhi) including preparation of mortar by traditional practice (by grinding) in specified course for base coarse and subsequent course & Loi, tamping, beating, curing till the shrinkage cracks are disappear. The work is to be done with all lead as the work is of restoration nature as per Jaipur practice including adding gur, methi & gugal on old walls including removal of all old loose and decade plaster, each coat to be done after 3 days of previous coat.
40645 mm thick in four coats
407Making Mehrab"s, Arches, pillars, highly decorative creepers, flower of small sizes etc.in lime Surkhi plaster (1:2) as per B248old traditional practices (Arches, Mehrab"s) in three coats for base course and subsequent course and Loi tamping, beating till the shrinkage cracks are disappear than making ornamental flowering/design etc. The work is to done with all leads and lifts as per work of restoration nature as per Jaipur practice.
408Add extra for Lime plaster work done over flat ceiling. (20%)
409Add extra over item no. 40.5 to 40.6 for Lime plaster work done over curved/circular masonary work (curved or circular surface.)
410Flush and ruled pointing over joints of dressed stone cladding, chajjas, jali etc. including racking the joints as per traditional practice including all leads and lifts with grinded mortar of lime putty and fine sand mixed in 1:2 ratio and gur, methi, gugal etc. are to be mixed as per traditional practice.
411Khamira Colour Washing as per old traditional practice to prepare the Khamira the lime should be slaked at least for 7-10 days and regularly it should be stirred by adding cured, Gugal, for nonsynthetic colour adding gum (babool gum) as per specification. Then applying prepared solution on walls three to four thin coats as desired finishing.
412Stucco work in lime, Surkhi, mortar (1:2) as per existing design work/traditional practices by skilled craftsman, the stucco work should be done as per restoration nature, the mortar should be prepared by grinding mill adding gur, methi & gugal.. The thickness varies from 50 mm to 100mm as per the design (minimum rectangular surface area to be measured).
413Providing & applying Lime kara 1:2 (1lime cream : 2 Zikki powder) grinding mortar with grinding mill/manually on lime base, on ceiling and all flat surface in two coats. First coat applying 3 mm to 4 mm thick and curing properly at least 7 days, second finishing coat done after 7 days of previous coat as per traditional practice.(thickness not more than 6 mm.)
414Add extra for Lime Kara work (on lime plaster base) other than flat surface as per traditional practice with all lead & lift with fine finishing complete in all respect on :
415(a) domical surface/spherical/domical ceiling.
416Providing & applying "Lime Kara on stone work only" having carving stone work /decorative stone work (stone pillars, stone arches, railing etc.) as per traditional practice, as per specifications with grinded mortar in two coats with finishing complete in all respect.
417Scraping & Removing of white wash/ distemper/oil paint/algli etc. from lime plaster highly decorative, ornamental and stucco work with at most care by using fine sand paper under the close supervision to keep intact the old designs.
418De-vegetation from monument by removing bushes, trees including complete uprooting from the wall & roofs/structures carefully including suitable chemical treatment to roots to avoid further growth including disposal of rubbish with in 50 mtr. Lead as per direction of Engineer in-charge.
419Water proofing with consolidation of basic substrata, making it complete water proofwith Protekta series of compounds of equivalent as per manufacturers specifications and as per directions of engineer in chrage.
420Chemical treatment of sand stone to clean from yellowness, blackness, algal growth, dust, dirt oily accretions, lime & gypsum deposits, filling of cracks/ joining of gaps/ pointing, strengthening of weak stone, removal of salt effect and application of preservative coating to prevent algal growth and make the stone water proof.
421Chemical treatment of marble stone to clean from yellowness, blackness, algal growth, dust, dirt oily accretions, lime & gypsum deposits, filling of cracks/ joining of gaps/ pointing, strengthening of weak stone, removal of salt effect and application of preservative coating to prevent algal growth and make the stone water proof.
422Removal , providing and re fixing of stone dasa moulded as per existing design with fine finishing fixing ingrinded lime mortar 1:2 i/c all lead and lift complete in all respect. extra for carving (pan patti)-100mm thick
423Making Kangura on top of the wall as per Jaipur traditional practice with tile brick bats/stones in grinded Lime Surkhi mortar 1:2 thickness of kangoora 15cm & height 45cm, finishing with lime Surkhi mortar 1:2 complete in all respect up to 10.00 meter from ground level including all scaffolding, lead & lift.
424Providing and fixing fine dressed sand stone/approved stone Traditional work as per existing matching geometrical design including molding work with fine finishing,fixing with tham+C23bli by proper adhesive and white cement with pigment including making groove etc. complete in all respect.
425Providing and applying ceilent adhesive to existing cracks by suitable silicon or equivalent ceilent complete in all respect and making it complete water-proof as per direction of the Engineer-in charge.
426Providing and applying breathable, non-reactive, transparent, antifungal, UV resistant, alkaline stable, impregnable silane-siloxane or equivalent based water repellent coating on exposed absorbing substrate like stone surface/ concrete surface/ mineral painted surface / exposed brick surface / lime surface in two or more coats to give uniform finish surface in all heights, horizontal, inclined, vertical and on ceiling complete in all respect and making it complete water-proof as per direction of the Engineer-in charge.
427Providing & fixing bamboo base deck at water surface level in lake to provide supporting platform for working and to support wall scaffolding above water level. The deck will include bamboo frame work under water. Horizontal MS frame and MS sheet covering to stop damage malba and other material to fall in water and maintaining in servicable condition for the required duration. The work includes provision of floating pontoon to carry material in and out of water, the bamboo base deck shall be stiffened with bracings, runners, connectors, with nearby structures etc. wherever location with essential safety features for the workmen etc. complete as per directions of engineer in charge
428Making Gardana under ceiling/ chajja with katla stone and grinded Lime surkhi mortar 1:2 including moulding work and fine finishing with grinded Lime surkhi mortar 1:2 as per existing matching/ traditional practice completev in all respect. (Size 35cm X 35cm.)
429MakingBend -patta, Cornice, Gola & String course with katla stone andLime surkhi mortar 1:2 (projected ) and finishing with grinded Lime surkhi mortar 1:2 including moulding/ design work as per existing matching at site complete in all respect. (Size 15cm X 10cm.)
430Providing and fixing "Corrugated" surface sand stone/approved stone flooring for ramp-way with fine dressed corrugation work as per approved design and size over a base of of grinded Lime surkhi mortar 1:2 and jointed with masaldarlime putty and stone powder 1:1 with an adixure of pigment, complete in all respect, as per direction of Engineer Incharge. ((b) 100 mm. stone slab)
431Providing & fixing fine dressed machine cut sand stone Stone steps (Treads & risers) with round nising as per existing matching fixing in lime surkhi mortar 1:2 including pointing in lime cream and stone dust 1:1 with an admixture (50mm to 60mm thick)
432Providing and fixing "Stone Kalasha" as per existing matching on doms od chattries/jharokhas as per existing design & dimensions as per traditional practices, fixing of kalash carefully without damaging the doms complete in all respect. (i) Kalasha height.(exposed part) 45cm. to 60cm.
433Providing and spray/brushing of Gur, gugal & methi solution for bonding of lime work as per specification (200gm gugal, 200gm belgiri powder, 200gm methi powder and 1 kg. Gur mixed in 20litre water and boiled and sttired till the solution volume reduce upto 3/4th) using 15.00litre solution in 10.00sqm. area.
434Providing and fixing fine dressed "sand stone flooring " with white sand stone (Bansh paharpur/dholpur stone) (panji marked surface) machine cut of approved shade set in pattern over 30mm thick base of lime surkhi mortar 1:2 including jointing finished flush with lime putty and stone powder with an admixture of pigment as per direction of Engineer incharge. (75mm thick)
435Providing and fixing fine dressed sand stone "Todies" (Brackets) as per existing matching stone with moulding work with fine finishing , fixing in grinded lime surkhi mortar 1:2 including scaffolding, lead & lift complete in all respect.
436(b)Size : 60cm X 45cm X 7.50cm (exposed part only.)
437Providing and fixing of fine dressed stone "Steps" (solid) of temple with matching stone/ approved quarry fixing of steps as per temple architecture by machanical/ mannual system carefully in proper order and sequence including all lead & lift as per direction ofEngineer incharge.
438Providing & fixing "ornamental stone cladding" of approved sand stone with dressing complete as per existing design/pattern/approved design,fixing with 30mm thickgrinded lime surkhi mortar 1:2 & pointing with white cement with araldite and pigment to match shade the stone complete in all respect as per direction of Engineer incharge.(75mm thick)
439Removal and refixing of stone chajja 50 to 75mm thick, stone used to be similar to the existing ones at the site, cutting in proper shape and providing interlocking keys in the new as well as old stone for proper bonding including finishing the edges in all respects in lime surkhi mortar (1 lime putty : 2 surkhi).
440Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in lime mortar 1:2 (1lime : 2coarse sand), including making the necessary chases.
441Providing & Fixing HDP Dustbins of 40 Liter Capacity (Wet & Dry seperatly) fixed CC foundation with MS pipe frames, complete in all respect as directed by engineer incharge.
442Providing,carving and Fixing of building signages inapproved sand stoneof size 750x450x50 mm. Engraving,painting of latters as per drawing and design. The signage stone shall be fixed on the building wall complete as per details and drawings and as directed by engineer incharge.
443Baori"s
444Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead..
445Carriage of Materials by mechanical transport including loading, unloading and stacking - for 5 Km.
446Earth
447Add extra for Lime plaster work done over flat ceiling. (20%)
448Tuman masonry by brick bats/ stones in grinded mortar of Lime Surkhi mortar 1:2/lime sand mortar 1:2 including racking and removal of all old loose plaster and cleaning the wall surface properly as per direction of Engineer In-charge.
449Providing and fixing stone Patties (slab) on roofing including removing broken patties carefully and replacement new slab with Kharanja, ralthal andlime dhar as per traditional practice. Span about 3.30 mtr. To 5.50 mtr. 100 mm to 150 mm thick of approved stone.
450Providing and laying lime Dhar on roofing as per Rajasthan, Jaipur traditional practice with lime, Surkhi, old lime powder, brick aggregate 12 to 20mm (1:2:2:2) and using Methi, Gur, Hemp, Belgiri etc. including beating and temping 100 to 150 mm thick as per specifications. Including dismantling of old detoriated roofing
451Painting on Stucco work with stone colours including base coat of khameera as per traditional practice (minimum rectangular to be measured).
452Providing and fixing fine dressed sand stone "Dasa/coping" as per existing matching , fixing in grinded lime surkhi mortar 1:2 including pointing in cream and stone powder 1:1 with an admixture of pigment to match the shade of stone complete in all respect.
453(b) above 100mm to 150mm thick plain with fine dressing.
454(d) above 100mm to 150mm thick with pan patti design.
455Stone flooring work with chisel dressed surface of approved shade and quarry in irregular shape as per existing pattern on a base of grinded lime sand mortar 30mm thick and jointing with masaldar lime putty and stone dust mixed in 1:1 ratio with admixture of pigment (75mm thick) stone as per existing matching.
456Random Rubble stone masonary for foundation and plinth in Lime surkhi mortar 1:2 above 30cm. thick walls in : ( 1 Lime putty : 2 Surkhi including adding admixture like gur, methi etc. in mortar.)
457Random Rubble stone masonary for superstructure, 4.50mtr. Height above plinth level/ one storey height above 30cm. thick walls in : Lime surkhi mortar 1:2 ( 1 Lime putty : 2 Surkhi including adding admixture like gur, methi etc. in mortar.)
458Providing and laying lime concrete in foundation and plinth using 40% lime mortar and 20mm nominal size graded aggregate (crusher broken ) including ramming and watering complete in all respect comprising of : ( 1 Lime putty : 2 Surkhi mortar.)
459Site clearance by uprooting of trunk vegetation, bush, wood, trees and sapplings of girth upto 15cms and disposal of rubbish with in 50mtr. Including leveling and dressing of ground as per direction of Engineer incharge.
460Dewatering of Baori by 10 HP Mud Pump including operator, fuel and maintenance and disposal of water as directed by engineer in charge complete in all respect.
461Stitching of masonrycracksby mechanical means by careful removal of the plaster and masonry of approximately 450mm to 900mm wide and 100 mm deep, removing all loose materials, cleaning with pressure water jets andfilling 1/3 rd depth with lime mortar 1:1:1:1 (1 lime : 1 fine sand :1 khakha : 1surkhi) over the cracked area by pressure grouting ( as klick nixon or equivalent) machine, then covering it with lime mortar 1:1:1:1 ( 1 lime: 1 fine sand: 1 khakha: 1 surkhi ) and finally grouted with liquid mortar complete and matching the existing condition and features of masonry. Cross masonry stitching in selective areas with matching bricks and lime mortar 1:1:1:1 (1 lime: 1 fine sand :1 khakha : 1surkhi) matching the courses of existing masonry under the supervision of the principal consultant (conservation architect).
462Silt and Sludge clearance of the entire Kund with sewage pumps or with labour/sweepers etc. to clean all the water sources below and on the sides of the Kund complete and disposal of the sludge including all leads and lift to some remote dumping ground, location of such dumping ground will be the responsibility of the Contractor and he had to comply with all statutory requirements.
463Providing/Carving/Fixing approved sand stone 2 Mt long benches with 75 mm thick pan patta dasa top fixed in stone pair as per detail drawings,design and as directed by engineer incharge complete in all respect.
464Gates
465P & L Lime Surkhi Plaster 1:2 (1 Lime : 2 Surkhi) including preparation of mortar by traditional practice (by grinding) in specified course for base coarse and subsequent course & Loi, tamping, beating, curring till the shrinkage cracks are disappear. The work is to be done with all lead as the work is of restoration nature as per Bundi practice including adding gur,methi & gugal on old walls including removal of all old loose and decade plaster, each coat to be done after 3 days of previous coat.
46633 mm thick in four coats
467Add extra over item no. 40.5 to 40.6 for Lime plaster work done over spherical or groin ceiling / ladao ceiling of doms
468Add extra over item no. 40.5 to 40.6 for Lime plaster work done over flat ceiling
469Add extra over item no. 40.5 to 40.6 for Lime plaster work done over curved/circular masonary work (curved or circular surface.)
470Removing of old lime plaster up to 75 mm thick in patches with height up to 4.5 m. Disposal up to 100 meter lead.
471Scraping & Removing of white wash/ distemper/algli etc. from plain plaster & surfaces gently with care to keep intact the old designs.
472Conservation of oil painting and portraitsin munuments by cleaning of the painted surface from all types of stains, dust, dirt, greasy & oily accretions etc. With the help of suitable chemicals, removal of cracks and holes, consolidation of flaking paint layer and plaster, filling of the lacunae in the plaster, treatment of salt effect, retouching of the lost portions and providing a preservative coating.
473Providing and Fixing fine dressed sand stone /approved stone "Chajja" for palaces,chattries,forts and jharokas with fine dressed surface both sides and front edges should be round shape/moulding, fixing in grinded lime surkhi mortar 1:2 joint flush with proper adhesive with pigment to match the shade of stone (thickness of chajja on front edge50mm and 75mm on fixing end) exposed surface is to be measured only.
474Repairing of existing historic window/doors for hardware, rotten/ deteriorated parts. Proper fixing and making it operational with locking possibility including moulding, carving and polishing complete as per details and drawings and as directed by engineer incharge.
475Providing and fixing in position Red Sand Stone Kerb of size 150 mmx300 mm and cut to shape as per with exposed face fine chiesel dresses fixing and jointing/pointing with cement mortar 1:4 using pigment as per drawing and instruction of Enineer Incharge complete in all respect.
476Electrical Fitting
477P & F of IP 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch OFF at preselected time. Switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purpose
478Suitable for 3 kw load direct lighting load (single phase)
479P & F of IP68, IK10 protected LED Buried marker light /Step Light Fixture. Fixture made of powder coated die cast aluminium with Toughened Glass cover and appropriate beam angle lens to be used as per requirement. The System level Luminous efficacy must be >90 Lumen/W. High Power LEDs at 1W/2W per LED. The driving current should be Minimum 350 mA per LED. CRI>70, CCT:3000/6500 K. The integral SMPS based electronic driver must be constant current and surge protection of min. 4KV(L-N) and efficiency >85%, PF>0.9 and input Voltage range of 90-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained. Light should include quick connecting cable coupled with various mounting accessories. Light output in Cool white or Warm White Colour as per engineers choice. Fixture must be in compliance with IS/CE Standards.
480Step Light - 5W
481Rectanglar LED Marker Light
482P &L of lP66 protected high power high power LED linear flood light system. Fixture made of powder coated extruded aluminium housing with UV stabilized PC/toughened glass cover and appropriate lens tobe used to achieve various beam angle pattern. fixture suitable for input 12vDC, power consumption should be 6W/0.5A per feet with system CRI- 70, color red/ green / blue/ /RGB /W/WW. the fixture must have IP66 protected 5mm Round female connector for input, the fixture must have provision to extend further . system life of 50000burning hours with 70% of initial lumens maintained . light output in red, green, blue, cool, white or warm white colour as per requirement. fixtures shall be CE complete series of linear flood light.
483Linear LED Strip 2 Feet (with Driver)
484Linear LED Strip 4 Feet (with Driver)
485Distribution Board
486Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) as per PWD specification for electrical Works with ISI marked (IS:12640-1) / conforming to IEC 61008 -1 , rated conditional s/c current of 10 KA, truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating, minimum phase termination capacity of 50 sq.mm. rigid wire , IP20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
487Two pole 30 mA sensitivity 25 A rating
488PVC Wiring Conduit
489S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall and making good the same as required.
49025mm
49132mm
492Wiring of 6 pin 15 amp. Light power point with 4.0 sq.mm PVC insulated unsheathed solid / stranded copper conductor 1.1 kV grade of approved make in surface /recessed ISI marked steel conduit & it"s accessories, 18 SWG M.S. box with earth terminal, screw less cage connectors for neutral looping in switch board , 15A switch, 15 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, bushes, check nuts, making connections, testing etc. as required.
493Short point (up to 3 mtr.)
494Medium point (up to 6 mtr.)
495Long point (up to 10 mtr.)
496Earthing
497Plate Earthing as per PWD specification for electrical Works as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. "B" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propyleneearth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
498Cable & Wiring
499Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade. Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free (<10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
5002 x 2.5 sq.mm
5012 x 4.0 sq.mm
502P&F of thermoplastic/ PVC cable junction boxes (United/ HPL make) of following sizes including clamps for holding the box, cost of DIN rail for MCB mounting, connectors for cables terminals, threaded cable glands made of polyamide material etc. complete in all respect.
503300mm X 200mm X125mm
504Labour charges for Excavation of 30cmx75cm size trench in CC road including refilling of excavated earth,compactionof earth, making good the same complete as required .
505Providing & Laying of 25 cm thick layer of river sand to cover of existing cable in 30cmx75cm size cable trench with levelling and making symmetric 25 mm thick layer in complete running length of trench as required.
506Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR.
507Armoured Cable
5084.0 Sq. mm
5092 core
510Supply, Installation, Testing and Commissioning of Spike Light of6 Watt and10 Degree Beam Deflection and 3000 K CCT similar to the Model LLO180 of Make Litomatic
511Supply, Installation, Testing and Commissioning of Spike Light of12 Watt and10 Degree Beam Deflection and 3000 K CCT similar to the Model LLO181 of Make Litomatic
512VAK make decorative haritage pole in 4 Meter height. Pole upper section of length 3mtr is of dia 76mm and 1 meter bottom section of dia 114mm with decorative casting with base plate as per drawing. Provision for inside termination box with 4way connector & 1nos 6 AMPS MCB for local isolation with cover.Complete in all aspects with foundation bolts
5134.0 Mtr
514Supply of VAK make Queen post top light in 30W LED IP65. Light fixture is made with corrosion resistant die cast aluminium. Height of the fixture is 850mm with width 500mm die cast base of dia 60mm closed by diffuser with durable proper silicone rubber gasket. Fitting is IP66 wired with Branded OSRAM or equivalent make LED and Fulham constant current driver. Proper thermal management for longer life of fixture. Fitting is suitable with heritage Decorative cast aluminium pole of 3mtr with cast aluminium emblishment with base od dia 300mm base plate 350x350x14mm as per shared drawing. Fitting is suitable for outoor application complete in all aspects with all accessories.
515Provision of Provisional sum to be used as tender document (fixed) : INR 50,00,000. Bidder should fill amount INR 50,00,000
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail