| 1 | Attending of day to day maintenance LED street/security/Gate light/Post top lantern/High mast light fixed at up to 16 mtr heightof any make complaints received through telephone or in person and reactification of defects installed on street light poles 9/11 mtr long, building walls, roof by bringing down the fittings on grond or in position including replacement of lamp, ignitor, flexible wire, reflector etc including cleaning of glass/acrylic cover for clear reflection of light, replacement of old unserviceable street light fittings with new fittings etc as required to make the light fitting functional Vehicle, ladder, tools and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement all as specified and directed by Engr-in-Charge.Note : (i) Light fitting, cable, flexible wire and LED drive if required to be replaced in repair shall be measured and paid separetely under relevant item of this BOQ for supply and fixing in replacement.(ii)Contractor manpower should be daily recieve a complaints at complaint cell at 9.00 AM by JE E/M and report after completion of complaints and handover a complaint slip as record of complaints with user signature.(iii)Old retrived material shall be deposited in AGE E/M yard and will be given to contractor after completion of contract. (vi)Quantity of material by contractor shall be decided by Engineer in charge based on requirement. Note:- Recovery @ 120/- per hour of the complaints is not being attended within six hours from intimation by rep of E/M subdivision through or telephonic/digital/ written complaints. |
| 2 | Taking down old unserviceable any type fitting and Supply and fixing Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge. Make : Havells/Philips/Bajaj |
| 3 | Taking down old unserviceable any type fitting and Supply and fixing Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge. Make : Havells/Philips/Bajaj |
| 4 | Taking down old unserviceable any type fitting and Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed by Engr-in-Charge. Make : Havells/Philips/Bajaj |
| 5 | Taking down old unserviceable any type fitting and Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed by Engr-in-Charge. Make : Havells/Philips/Bajaj |
| 6 | Taking down old unserviceable any type fitting and Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed by Engr-in-Charge. Make : Havells/Philips/Bajaj |
| 7 | Taking down old unserviceable any type of post top lantern fitting and Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-Charge. Make : Havells/Philips/Bajaj. |
| 8 | Taking down old unsv PCC Poles and Supply, fixing and installation of Octagonal poles. Supply and install hot dip galvanized steel (IS 5986 Gr. Fe 510) Octagonal pole model NJOP 7 of 7.0 mtr long, top top die 70 mm botom dia 130 mm having thickness 3 mm having door operating of size 500 mm above ground level with CI Base plate of size 220x12mm having PCD 205 mm foundation J bolts length 700 mm nuts and screwes, No\"s of bolts 4 x 20 and having hot dip galvanized double plain arm bracket 1000 mm overhang on one side with 48.3 mm outer dia pipe of thickness 3.2 mm fixed on topwith bolts and necessary earth work RCC/PCC work for the foundation of pole, including necessary form work and fare finish to exposed surfaces without using extra cement etc complete all as specified. Make : Bajaj/Crompton/Havells. |
| 9 | S&F junction box factory made weather proof size 250mm x 200mm x 100mm made of 16gauge steel sheet powder coated inculded25mm x 6mm aluminium TPN bus bars & 01 MCB 10 Amps for controlled one No\"s of LED Lights complete all as specifed & directred by Engr-in-Charge. |
| 10 | S&F in replacement 1100 volt grade heavy duty cable 3 core 1.50 Sqmm PVC insulated copperstranded conductor passing through in 20 mm PVCpipe of cable sizesize 1.50 Sqmm for connection pupose of street light fitting from DB to street light fitting, Rate of PVC pipe shall be included in quoted rate by contractor complete all as specified and directed by the Engr-in-Charge. |
| 11 | Taking out old unserviceable underground cable fromtrenches/ floors/road/wall /pipe/ pole LT cable of any size/ description complete all as specified and directed by the Engr-in-Charge. |
| 12 | Supplying, laying, jointing and testing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 vols grade cross sectional area 16 Sqmm 4 core laid in trences, in floor, in duct, through pipes or along the pole including taking down old one complete all as specified and directed by Engr-in-Charge. |
| 13 | All as per item No 12 but cross sectional area 10 Sqmm 2 core. |
| 14 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for foundation of poles/ stays/ laying of cables etc and gettingout including trimming of sides of trenches complete all as specified and directed by the Engr-in-Charge. |
| 15 | Returning, filling the soft / loose soil including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and directed by the Engr-in-Charge. |
| 16 | Removing of surplus excavated soilto a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by the Engr-in-Charge. |
| 17 | M&L for sand cushioning to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable complete all as specified and directed by the Engr-in-Charge. |
| 18 | M&L for brick protection using old size sub class ‘B’bricks, laid flat, dry adjacent to each otherlaid length wiseperpendicular to theaxis of cable complete all as specified and directed by the Engr-in-Charge. |
| 19 | M&L for preparation of old painted surface of Steel tubler Street light poles and applying two coats of synthetic Aluminium paintfrom top to botom including Light breakets complete all as specified and directed by the Engr-in-Charge. |
| 20 | Labour only for cutting/pruning of tree branches 1.5 mtr all around the LT overhead lines of span n.exc 70 mtr and around the pole obstruction the overhead line & removing the branches to distance n.exc 50 mtr to be the entire satisfaction of Engr-in-Charge. |
| 21 | Supply fabricating erecting LT panel outdoortype CPRI approved double door totally enclosed weather and vermin proof suitably ventilated 415 Volts50 cycles, AC supply factory made fully compart mentalized made out of 3.00 mm thick CRCA sheet for laod bearing and 2.00 mm thick for nonload bearing protection of enclose IP 54 as per IS 2147 of 1962 with pretreatment and powder coated of approved colour including suitable size of abgle iron/flat iron frame work/ support required civil works, excavation & earth work, PCC foundation etc, installation, testing & commissioningwith including the following :-(a) Aluminium bus bar of capacity 600 Amps for phase and 300 Amps for Neutral.(b) Combined Voltmeter & Ammeter 0 to 500 Amps digital type with built in selector switch CTS of suitable ratio (Set of Three)Incoming : (i) MCCB TPN 100 Amps, 36 KA 415 Volts 4 pole (Thermal Magnatic and microprocessor release- 01 No Outgoing : (i)MCCB 4 pole 63 Amps 36 KA, 415 Volts (adjustable thermal and magnatic type70% to 100%)- 04 No (ii) Digital type Digital Timer switch suitable for 3 phase, 415 volts AC supply for street light feeder programmable 1 min, with backup for 6 years, 28 memory locations, current capacity 10 Amps weekly program with 1 changeover (1co) total 28 programs Model No DIN, Type ECO weekly with 1 CO cat part No TDA44196. |
| 22 | M&L for earthing complete with galvanized iron or steel or steel earth plate electrode of size 60cmx60cmx6.3mm thick buried directly in ground, vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI Strip of size 32x6 mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe light grade 20 mm bore for watering including providing funnel and wire mesh GI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40mm graded stone aggregates complete including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in plate No 5 of SRR-1991 Part-1 . |
| 23 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as specified and directed by the Engr-in-Charge. |
| 24 | S&F in replacement of Time light distribution board analog Time switch 230 volt three phase of 16 Amps rating with contactor fixed inside steel enclosure box and fixed to pole/LT Panel including clamps, nuts, bolts and washers etc complete all as specified and directed by the Engr-in-Charge. Make Indo-Asian cat part No TL016ABO or equivalent in Legrand/Scheneider |
| 25 | S&F in replacment MCCB 250 Amp, 4 pole, 36 KA 415 Volt 50 Hz with adjustable thermal release and adjustable magnetic setting complete all as specified and directed by the Engr-in-Charge. Make : Standard CAT Part No ISLCNF 0250 (Frame size SKB-3) or equivalent CAT part of make Havell\"s/ Siemen\"s/ Schnieder |
| 26 | S&F in replacment MCCB 200 Amp, 4 pole, 35 KA 415 Volt 50 Hz with adjustable thermal release and adjustable magnetic setting complete all as specified and directed by the Engr-in-Charge. Make : Standard CAT Part No ISLCNF 0250 (Frame size SKB-3) or equivalent CAT part of make Havell\"s/ Siemen\"s/ Schnieder |