Tender For Repair To Flooring/Plastering, Tilling, Sewage Line, Manhole, Septic Tank Etc B/R Works And Repair Of Summer Appliance, Lt Switch Gear, Mccbs, Acbs Etc E/M Works And Repair Of Acs And Other Appliance At Palam Area Under Aor Of Ge (Af) Far, delhi-Delhi

Military Engineer Services-MES has published Tender For Repair To Flooring/Plastering, Tilling, Sewage Line, Manhole, Septic Tank Etc B/R Works And Repair Of Summer Appliance, Lt Switch Gear, Mccbs, Acbs Etc E/M Works And Repair Of Acs And Other Appliance At Palam Area Under Aor Of Ge (Af) Far. Submission Date for this Tender is 19-06-2023. Switch Gear Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

38000759
Tender For Repair To Flooring/Plastering, Tilling, Sewage Line, Manhole, Septic Tank Etc B/R Works And Repair Of Summer Appliance, Lt Switch Gear, Mccbs, Acbs Etc E/M Works And Repair Of Acs And Other Appliance At Palam Area Under Aor Of Ge (Af) Far
Open Tender
Indian
Delhi
delhi
19-06-2023

Tender Details

Repair To Flooring/Plastering, Tilling, Sewage Line, Manhole, Septic Tank Etc B/R Works And Repair Of Summer Appliance, Lt Switch Gear, Mccbs, Acbs Etc E/M Works And Repair Of Acs And Other Appliance At Palam Area Under Aor Of Ge (Af) Faridabad

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work: REPAIR TO FLOORING/PLASTERING, TILLING, SEWAGE LINE, MANHOLE, SEPTIC TANK ETC B/R WORKS AND REPAIR OF SUMMER APPLIANCE, LT SWITCH GEAR, MCCBS, ACBS ETC E/M WORKS AND REPAIR OF ACS AND OTHER APPLIANCE AT PALAM ARE UNDER AOR OF GE (AF) FARIDABAD
Sl. No. Item Description
1Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc,complete all as specified and directed by Engineer-in-Charge.
2M&L for Brickwork with subclass "B" bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
3All as per item No 02 above here in but except bricks complete all as specified and directed by Engineer-in-Charge.
4M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
5Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
6M&L for rendering 15 mm thick cement plaster in CM 1:6 onbrick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
7M&L, Rendering 15mm thick in CM 1:4 onof brick work or concrete surfacefinish ever and smooth (w/o using extra cement) incl WPC as per user manual complete all as specified and directed by Engineer-in-Charge.
8M&L for rendering 10mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
9M & L for preparation of new plastered surface and applying two coats of oil emulsion distemperon wall over one coat of primer incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
10M&L for preparation of new plaster surface & apply twocoats of cement based paint over a coat alkali primer resistanceincl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
11M & L for preparation of new plastered surface and applying two coats of oil emulsion distemperon ceiling over one coat of primerincl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
12M&L fortwo coat ofAcrylic smooth exterior emulsion paint over one coat of acrlic primer incl one layer of 3mm thick wall care compound of altek/birlaputty for exterior/interior on old scraped wall/ceiling surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge. Note : Colour and make as approved by Engr-in-Charge.
13Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and directed by Engineer-in-Charge.
14M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm agg. ) as in plinth protection / path/ any paved area complete all as specified and directed by Engineer-in-Charge.
15M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge.
16M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, with grey cement, pigmentincl 25mm thick sand fillingcomplete all as specified and directed by Engineer-in-Charge.
17M&L for 60 mm thick machine cut precast concrete inter locking paver block except tile ,(M-35) grade any clours complete all as specified and directed by Engineer-in-Charge.
18M&L for 80 mm thick machine cut precast concrete inter locking paver block except tile ,(M-40) grade any clours complete all as specified and directed by Engineer-in-Charge.
19M & L for sand filling under floors or in foundationincluding watering and consolidation complete all as specified and directed by Engineer-in-Charge.
20M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed by Engineer-in-Charge.
21M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying offloor/sub base finishes complete all as specified and directed by Engineer-in-Charge.
22M&L for non skid ceramic coloiured tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling tiles etc complete all as specified and directed by Engineer-in-Charge.
23All as per item No 22 above item but here- in area of each tile exe 0.11 sqm but n.exe 0.18 sqm, in floors & dado etc complete all as specified and directed by Engineer-in-Charge.
24M& L for Glazed ceramic jointless light/coloured group of size 300/350mmx450/600mm, thickness not less than 6mm as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement and pigment to match,laid over and including 10mm thick plastering in cement mortar 1:4,incl dismantlingtiles etc complete all as specified and directed by Engineer-in-Charge. Note : shade & design as approved by EIC/GE
25M&L for coloured Non Skid Ceramic tiles7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling tiles etc complete all as specified and directed by Engineer-in-Charge.
26M&L for Virified tiles light shade /dark shade 10 mm thick (square/ rectangular) polished, area of each tiles not exc 0.36 sqm , in floors, dado , skirtingetc. set and jointed in neat cement slurry over 15 mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes and pointed in white or coloured cement to match and incl dismantling tiles etc complete all as specified and directed by Engineer-in-Charge.
27Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.laid, bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge.
28M&L for Granite 20 mm thick (of any type ) (table runned and polished ) in floors steps , jamns, pillars,window-cills,cooking plateforms and vertical surfaces bedded and jointed with grey cement slurry and pointing in white ciment (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge.
29M&L rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engineer-in-Charge.
30M & L for viterous china squating pan of (Orrissa Pattern) size 580x440 mm white with "P" or "S" trap front or back inlet and integral foot rest (excluding flushing cisteern and flush pipe) fixed in repair including lime concrete bedding as required set complete all as specified and directed by Engineer-in-Charge.
31S&F for Vitreous China wash down water closet pan (pedestal pattern) with trap, white (excluding fixing bolts, flushing cistern and flush pipe) incl connection to drain and flushing pipe complete all as specified and directed by Engineer-in-Charge.
32S&F in repair ofPVC flushing cistem low level white with all accessories of 10 ltrs capacity incl flushing pipe, brackets and taking down of old CI/PVC flushing cistern complete all as specified and directed by Engineer-in-Charge.
33S&F for 15 mm bore Twin one angle valve/ bib tap cast copper alloy chromium plated, fancy type, screwed down high pressure, screwed both ends for ironpipe or for union complete all as specified and directed by Engineer-in-Charge.
34S&F CP jetfor EWC along with pvc connection complete all as specified and directed by Engineer-in-Charge.
35S&F for Toilet paper holder,stainless steel,fixed with and including chromium plated brass screws and and wooden/plastic cleatson walls,complete all as specified and directed by Engineer-in-Charge. Make:Jaquar Cat Part No. AKP 35753PS or equivalent.
36S&F for Health faucet brass CP with 8mm dia 1.2 mtr long flexible pipe and wall hook fixed with brass chromium plated screws,complete all as specified and directed by Engineer-in-Charge. Make:Jaquar Cat Part No. ALD CHR-573 or equivalent .
37S&F in repair forVitreous China wash basin (Pedestal pattern), White, flat back, size550x400 mmexcluding taps, waste, chain and plug and porcelain stopperbut including brackets complete all as specified and directed by Engineer-in-Charge.
38M&L in repair for 600x450 mmbeveled edge mirror of selected quality glass, mounted on 6 mm thick AC building board and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed by Engineer-in-Charge.
39S& F for swan neck pillar cock fancy typechromium plated screw with iron pipe incl all fittings in repairs complete all as specified and directed by Engineer-in-Charge.
40S&F in repair CP brass centre hole mixer without pop up waste system 15mm bore for mixing hot and cold water screwed down for iron pipe for WHB, complete all as specified and directed by Engineer-in-Charge.
41S&F in repair for Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms)complete all as specified and directed by Engineer-in-Charge.
42S&F in repair for liquid soap container of PTMT fixed with and incl CP brass screws and wooden/plastic cleats complete all as specified and directed by Engineer-in-Charge.
43S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm longcomplete all as specified and directed by Engineer-in-Charge.
44S & F in repairvitreous china urinals, half stall type (635x450mm) , complete including providing and fixing , bedding urinal against wall in cement mortar 1:2 , pointing around urinal back in cement , grating and union for discharge pipe, (Exclusive of fixing supply pipe to flushing cistern, trap&waste pipe complete all as specified and directed by Engineer-in-Charge.
45S&F in repair for Curverbshape urinal partition with frosted glass 8mm thk size 900x450 mm complete all as specified and directed by Engineer-in-Charge.
46S&F for Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed by Engineer-in-Charge.
47S&F for 32 mm dia Waste coupling of PTMT (half or full threaded) suitable for urinal . (Minimum weight 32mm45gms)complete all as specified and directed by Engineer-in-Charge.
48S & F in repair Bib tap CP fancy type long body 15 mm bore with will crutch or buttewrfly handle screwed down screwed to iron pipe complete with all fittings complete all as specified and directed by Engineer-in-Charge.
49S & F in repair Stop cock /angle CP fancy type 15 mm bore screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for Unions complete all as specified and directed by Engineer-in-Charge.
50S & F in repair Stop cock concealed long shank chromium plated fancy type 15 mm borescrewed down high pressure with crutch or butter fly handle complete all as specified and directed by Engineer-in-Charge.
51S&F in repair for wall mixer with provision for overhead shower with 115 mm long bend pipe on upper side, connecting legs and wall flanges, complete all as specified and directed by Engineer-in-Charge. Make: ESS cat part No EC-10 or equivalent.
52S&F for Brass chromium plated shower rose of 200mm size with arm and with or without swivel joints,complete all as specified and directed by Engineer-in-Charge.Make: Jaquar Cat Part No. OHS 1779 for shower and SHA 49483 for arm or equivalent.
53S&F Ball valve, high pressure with PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe orfixed of size 20 mm bore, fixed in repairs.(Min Wt 20mm- 210 gms) complete all as specified and directed by Engineer-in-Charge.
54S&F Ball valve, high pressure with PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe orfixed of size 15 mm bore, fixed in repairs.(Min Wt 20mm- 210 gms) complete all as specified and directed by Engineer-in-Charge.
55S&F for Soap dish,fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
56S&F for PVC connections 60cm long superior quality with PTMT nut on both side complete all as specified and directed by Engineer-in-Charge.
57S&F in repair grating round 125mm size of CP complete all as specified and directed by Engineer-in-Charge.
58S&F stainless steel pegset of six suitable size of length complete all as specified and directed by Engineer-in-Charge.
59Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing or removed to store complete all as specified and directed by Engineer-in-Charge.
60S&F for GI tubing 15mm boremedium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required complete all as specified and directed by Engineer-in-Charge.
61Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directed by Engineer-in-Charge.
62S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
63Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 25 mm dia bore complete all as specified and directed by Engineer-in-Charge.
64S&F GI tubing 25 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
65Cleaning /removal of blockage 150 mm bore SWG pipes of depth not exc 1.50 mtr with mechnical processincl removing RCC man hole coversand refixing the same as before complete all as specified and directed by Engineer-in-Charge.
66Cleaning /removal of blockage 150 mm bore SWG pipes of depthexc 1.50 mtr but not exc 3.00 mtr withmechnical process incl removing RCC man hole coversand refixing the same as before complete all as specified and directed by Engineer-in-Charge.
67Dewatering/desilting of existing manholes of any size depth and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system or using suction pump where ever required up to any depth )and incl removing RCC manhole Covers and refixing the same after making the manhole fully functional, complete all as specified and directed by Engineer-in-Charge.
68Dewatering/desilting for the septic tank of any capacity exc1.50 m and n.exc 4.5 m deepsolid/semi-solid matter of silt residue both organic or inorganic in nature ( mechanical system or using suction pump where ever required up to any depth by working under foul conditions and disposal of the same in out of MoD area, complete all as directed by Engineer-in-Charge.Note for Item: The Septic tank shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
69Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft or loose soil for shafts, wells,drains, manholes etc n exc 10Sqm on plan for sewage line & foundation etc complete all as specified and directed by Engineer-in-Charge.
70All as per item No 69 but exceeding 1.5 M depth and not exceeding 3 M for foundation, etc., and getting out in Soft/ Loose soil complete all as specified and directed by Engineer-in-Charge.
71All as per item No 69 but exceeding 3.0 M depth and not exceeding 4.50M for foundation, etc., and getting out in Soft/ Loose soil complete all as specified and directed by Engineer-in-Charge.
72Demolition and breaking up drain pipes 100mm dia ( Salt Glazed ware, AC or reinforced concrete) set in cement mortar including PCC bed and haunching and removal of debris outside the MD land complete all as specified and directed by Engineer-in-Charge.
73Demoltion and breaking up existing sewag(SWR/ AC pipes and the like, 150mm bore set in cement mortar and removing demolished material to a distance exc 50m and n exc 100m complete all as specified and directed by Engineer-in-Charge.
74Demoltion and breaking up existing sewage (SGSW / AC pipes and the like, 200mm bore set in cement mortar and removing demolished material to a distance exc 50m and n exc 100m complete all as specified and directed by Engineer-in-Charge.
75S&F 110 mmPVC (SWR ) , pipes single socketd , in any lengthwith rubber ring joints , laid in trenches or in floor complete all as specified and directed by Engineer-in-Charge.
76S & F RCC Class NP 3, 150 mm bore pipes laid and jointed complete with collars complete all as specified and directed by Engineer-in-Charge.
77S & F RCC Class NP 3, 200 mm bore pipes laid and jointed complete with collars complete all as specified and directed by Engineer-in-Charge.
78M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 100 mm bore complete all as specified and directed by Engineer-in-Charge.
79M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all as specified and directed by Engineer-in-Charge.
80M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 200 mm bore complete all as specified and directed by Engineer-in-Charge.
81S & F in repairfor precast factry madereinforced cement concreteManhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of60mmthick (size of the cover will be itimated by the Engineer-in-Charge) complete all as specified and directed by Engineer-in-Charge.
82S&F mild steel work such as in angle iron, flat iron fillets etc for horn, fixing of barbed wire to RCC post, securing wire mesh etc. including all necessary cuttings, drilling, bolting or riveting etc and including 10mm MS bars as in tie bars fixed to fencing posts including necessary welding where required, as per site requirement and other similar works complete, conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge.
83S&F in repair precast factory made polycrete (SFRC) medium duty perforated drain cover 100 mm thick rectangle in shape upto 01 sqm areaeach with hole for drain complete all as specified and directed by Engineer-in-Charge.
84Returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm complete all as specified and directed by Engineer-in-Charge.
85M&L for Plain cement concrete (1:2:4) Type B-1, (using 20mm graded crushed stone aggregate), as incopings, kneelers , apex stones,bed plates, including weathering ,slightly rounded /benching or chamfered angles and throating , complete all as specified and directed by Engineer-in-Charge. ( Rates include for use of formwork)
86Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 100mm dia pipecomplete all as specified and directed by Engineer-in-Charge.
87Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 150mm dia pipe complete all as specified and directed by Engineer-in-Charge.
88Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 200mm dia pipe complete all as specified and directed by Engineer-in-Charge.
89M&L for salt glazed stoneware gully trap, square or round moulded type "P", 150x150mm size complete all as specified and directed by Engineer-in-Charge.
90M&L for cement concrete 1:3:6 type C2 (using 20 mm gradedstone aggregate) as in surface channels, drains and bed of manholecomplete all as specified and directed by Engineer-in-Charge.
91Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.complete all as specified and directed by Engineer-in-Charge.
92M & L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling, and mass concrete complete all as specified and directed by Engineer-in-Charge.
93M&L for loose filling with broken bricks aggregate of gauge 80 to 150mm in soakage pits, soakage wells complete all as specified and directed by Engineer-in-Charge.
94M&L for loose filling with broken bricks aggregate of gauge 40 to 80mm in soakage pits, soakage wells complete all as specified and directed by Engineer-in-Charge.
95S&F for 100mm bore Cast iron soil, waste and vent pipes, in any lengthwith or without ears, with cement joints, fixed to walls etcincl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
96S&F for 75mm bore Cast iron soil, waste and vent pipes, in any lengthwith or without ears, with cement joints, fixed to walls etc complete incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
97S&F for 100mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
98S&F 75mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
99S&F for 100mmbranch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches/ Tee etc complete all as specified and directed by Engineer-in-Charge.
100S&F for 75mmbranch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches/ Tee etc complete all as specified and directed by Engineer-in-Charge.
101S& F for 75 Cast Iron Cowl complete all as specified and directed by Engineer-in-Charge.
102S& F for 100 Cast Iron Cowl complete all as specified and directed by Engineer-in-Charge.
103S&F for 75mm dia of outlet cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engineer-in-Charge.
104S&F for 100mm dia of outlet cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engineer-in-Charge.
105S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cmlength "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed by Engineer-in-Charge.
106All as per ser item No 105above but laid in trench or in floor complete all as specified and directed by Engineer-in-Charge.
107S&F for 110mm bore PVC Gully Trap setting / jointed with solvent cement complete all as specified and directed by Engineer-in-Charge.
108S&F for 110mm bore PVC bends/junctionany radius complete all as specified and directed by Engineer-in-Charge.
109S&F for 110mm bore PVC bends/junction with access door any radius complete all as specified and directed by Engineer-in-Charge.
110S&F for 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
111S&F for 75mm dia PVC (SWR) multi floor trap, plain with grating including jointing with solvent cement complete all as specified and directed..
112S&F for 75 mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cmlength "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed by Engineer-in-Charge.
113All as per ser item No 112above but laid in trench or in floor complete all as specified and directed by Engineer-in-Charge.
114S&F for 75 mm bore PVC bends/junctionany radius complete all as specified and directed by Engineer-in-Charge.
115S&F PVC (SWR) floor trap, plain with CP grating including jointing with solvent cement, 75mm diameter of outlet, complete all as specified and directed by Engineer-in-Charge.
116Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, fascias, fins and similar works complete all as specified and directed by Engineer-in-Charge.
117M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs ( for manholes etc.), shelves and similar articles with plain faces including necessary form work, set in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. (Reinforcement shall be measured and paid for separately under respective item of schedule "A").
118S&F TMT MS bar 10 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-Charge.
119Removing daberies/excavated material to a distance exceeding 1.5KM butnot exceeding 5 KM and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed by Engineer-in-Charge.
120Repair and Maintenance ofsplit type AC"s of capacity 1.5/2 TR comprising of the following tasks installed at different locations includingtesting complete all as specified and directed by Engineer-in-Charge.(a) Inspecting and checking the Indoor/outdoor units for noise free operation (b)Checking the electrical connection for tightness (c) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower.(d) Greasing/Oiling of condenser fan motor and blower motor. (e)Checking for any refrigerant leakage. (f) Checking for serviceability of remote control unit.
121Supply and fixing in replacement of starting capacitor 80-100/100-120 mfd for split type A/C"s of capacity2 TR complete all as specified and directed by Engineer-in-Charge.
122S/F in replacement of running capacitor 30/36 mfd for split type AC unit as required at Site and complete all as specified and directed by Engineer-in-Charge.
123Taking out burnt condenserfan motorandrewinding of condenserfan motor of split type AC units of capacity 1.5/2 TR including replacement of worn out bush and bearing complete all as specified and directed by Engineer-in-Charge.
124Taking out burnt blower motor and rewinding of blowermotor of split type AC units of capacity1.5/ 2 TR including replacement of worn out bush and bearing complete all as specified and directed by Engineer-in-Charge.
125Repair / replacement of swing motor of split type AC units of capacity1.5/ 2 TR including replacement of worn out bush and bearing complete all as specified and directed Engineer-in-Charge.
126Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and Fix new compressor with charging of refrigerent after dehydration testing and vaccummingone as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge.
127Disconnecting and taking down burnt compressor of capacity 1.5 TRwith CFC free Refrigerent (R410a,R32) from split type AC unit and Supply and Fix new rotary/reciprocating type compressor with charging of refrigerent after dehydration testing and vaccummingone as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge.
128M&L for repair to water leakage complaint in split type AC unit of capacity 1.5/2TR capacity complete all as specified and directed by Engineer-in-Charge.
129M&L for repair to gas leakage of split type AC unit of capacity 1.5/2TR capacity including pressure testing, dehydration and gas charging complete all as specified and directed by Engineer-in-Charge. Note : Refrigerant gas will be measured and paid separately
130M&L for repair to gas leakage of window type AC unit of capacity 1.5/2TR capacity including pressure testing, dehydration and gas charging complete all as specified and directed by Engineer-in-Charge. Note : Refrigerant gas will be measured and paid separately
131Supply and charging Refrigerant(R410,R32,R134 and existing refrigerent) to any type of AC unit including CFC free and non CFC Free AC complete all as specified and directed by Engineer-in-Charge.
132M&L submain wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length) complete all as specified and directed by Engineer-in-Charge.
133Taking down carefully water heater storage type 25 ltrs/50 Ltrs capacity for repair and over hauling and opening to geysers and comprising of heating element thermo stat switch, electric connection cleaning and descaling with descaling solution the geysers tank and checking of leakage on pressure at 150 PSI and testing for smooth functioning complete all as specified and directed by Engineer-in-Charge.
134S&F in replacement of heating element 1.50 KW capacity 230 volt suitable for geysers any type as per site requirement ISI mark complete all as specified and directed by Engineer-in-Charge:-
135S&F in replacement thermostat switch connection any type suitable for geyser of any size/model complete all as specified and directed by Engineer-in-Charge.
136S&F in replacement of geyser assembly any make any type for 25 ltrs/50 ltrs capacity water heater including replacement of rubber seal complete all as specified and directed by Engineer-in-Charge.
137Supply and fixing in replacement of indicator lamp (Pilot type)for 25 ltrs water heater complete all as specified and directed by Engineer-in-Charge.
138Supply and fixing in replacement of PVC insulated copper conductor cable 4 Sqmm size 3 core grade (For Geyser) complete all as specified and directed by Engineer-in-Charge.
139S&F in replacement of water storage tank of suitable for 25ltrs capacity incl glass wool complete all as specified and directed by Engineer-in-Charge.
140Supply & fixing in replacement ofbottom cover suitable cylindrical type geyser for 25 Ltrs/ 50 Ltrscapacity geyser complete all as specified and directed by Engineer-in-Charge.
141M&L for preparation of external surface of geyser body 25 ltrs rubbing the rusted surface and painting with two coats of spray paint with synthetic enamel paint over a coat of metal primer matching with existing colour complete all as specified and directed by Engineer-in-Charge.
142S& F heavy duty PVC pipe suitable for hot water flow for geysers of capcity 25 to 50 ltrs complete all as specified and directed by Engineer-in-Charge.
143S& F plug top 3 pin ,15 Amps rating all as specified and as directed by Engineer-in-Charge
144S& F plug top 3 pin ,5 Amps rating all as specified and as directed by Engineer-in-Charge
145Taking down desert cooler of any size by disconnecting electrical supply, cleaning, oiling of all moving part of pump & exhaust fan/kit, Replacing PVC pipes, nozzles, distributors, pads, checking electrical connections complete all as specified and directed by Engineer-in-Charge.
146Supply and fixing in replacement of wood pads(set of three)as per sample complete all as specified and directed by Engineer-in-Charge.
147Supply and fixing in replacement the new desert cooler pump including testing for proper functioning complete all as specified and directed by Engineer-in-Charge.
148Supply and fixing in replacement new body of desert cooler as per sample duly painted of 20 SWG sheet with 22 SWG flops, front grill, PVC pipe, nozzle, distributor and nut bolts washers for fixing fanclamps, complete all as specified and directed by Engineer-in-Charge.
149Supply and fixnew exhaust fan kit of desert cooler with super enameled copperwire complete all as specified and directed by Engineer-in-Charge.
150Taking down and rewinding offan motor 400mmof desert cooler with super enameled copper winding wire including replacement of bush complete all as specified and directed by Engineer-in-Charge.
151Supply and fixing front grillPVC of desert cooler as per sample complete all as specified and directed by Engineer-in-Charge
152Supply and fixing in replacement plug top 15 Amps all as specified and directed by Engineer-in-Charge.
153Supply and install 400 mm fan bade suitable for desert cooler all as specified and as directed by Engineer-in-Charge
154Supply and fixing in replacementventilating fan plastic 250 mm sweepbody 240 v 50 Hz single phase all as specified and directed by Engineer-in-Charge.
155Supply and fixing in replacementventilating fan plastic 300 mm sweepbody 240 v 50 Hz single phase all as specified and directed by Engineer-in-Charge.
156Supply and fixing in replacement wall mounted fan plastic body 240 v single phase 50 Hz all as specified and directed by Engineer-in-Charge.
157Supply and fixing in replacement of PVC insulated copper conductor cable 4 Sqmm size 3 core grade (For Geyser) complete all as specified and directed by Engineer-in-Charge.
158Supply and install in replacement AC Box with plug and socket complete with 16 to 32 Amp SP MCB C Curve 10 KA complete all as specified and directed by Engineer-in-Charge
159Supply and fixing in replacement of capacitor of following sizes complete all as specified and directed by Engineer-in-Charge (a).2.5 Mfd.
160All as per item No 159 above but3.15 Mfd complete all as specified and directed by Engineer-in-Charge
161M&L for rewinding of burnt fan1200 mm/1400 mm sweepwith super enameled copper wire winding, rubber real, U’ clamps, nuts, bolts, washers and split pins of suitable size as per details of any make/model complete all as specified and directed by Engineer-in-Charge.
162Taking down ceiling fan 1200 mm/1400 mm sweep removing cleaning of dust, properly cleaning and replacing of bearing and connecting up complete all as specified and directed by Engineer-in-Charge.
163Supply in replacement for rewinding of exhaust fan as per details given below with supper enameled copper wireof suitable size of any make/type/model including transportation complete all as specified and directed by Engineer-in-Charge :-(a) Exhaust fan 300mm (12’size)
164(b)Exhaust fan 380mm (15” size)
165Supply in replacementfor exhaust fan Louver of following size complete all as specified and directed by Engineer-in-Charge. (a) 380 mm
166All as per item No 165 above but 300 mm complete all as specified and directed by Engineer-in-Charge.
167Taking down carefully defective wall mounted fan of any size and make and oiling greasing after opening and refixing the fan to its position after repair and testing complete all as specified and directed by Engineer-in-Charge.(a)Wall fan of size 400mm
168M&L for rewinding of wall mounted fan given below with super enameled copper wire Including of suitable of size of any make/type model complete all as specified and directed by Engineer-in-Charge:Wall fan of size 400mm
169S&F in replacement for wall mounted fan bushes ,shaft and suitable body cover ,moving partcomplete all as specified and directed by Engineer-in-Charge.
170Repair & maintenance of Refrigerator of any capacitycomprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge. a) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. c) Inspecting the leakage in the system. d) Checking of the earth continuity of electrical parts. (e) Checking the functioning of thermostat. f) Inspection of all electrical parts. g) Testing the machine for satisfactory operation. (h) Check and correct all electrical wiring & test its functioning (j) Testing of Refrigeratorafter repair.
171Repair & maintenance of water coolers ofcapacity 40/80/150Ltrs comprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge. (a) Inspection, taking down, opening, dismantling, decaling, brushing cleaning of storage tanks (b) Examination water tightness, leak proof of storage tank after cleaning.(c) Carry out operation of all stop cock, push cock, float valve etc. (d) Inspect overflow and remove blockage if any. (e) Check and correct earth continuity of electric items (f) Check thermostat and test its functioning (g) Inspect drain pipe and remove blockage if any (h) Check and correct all electrical wiring & test its functioning(i) Testing of water cooler after repair
172Supply & fixing in replacement of thermostat switch suitable for water cooler 40/80 as required at site complete all as specified and directed by Engineer-in-Charge
173Supply and Fixing in replacement fan motor capacitor2.5/3.15mfd. complete all as specified and directed by Engineer-in-Charge
174Supply & fixing in replacement of starting relay as requiredat site for water coolers 40/80 Ltrs capacity complete including connecting, testing complete all as specified and directed by Engineer-in-Charge
175Supply and fixingin repair PVC insulated Sheathed, Copper conductor,6 sq mm ,3 core (flexible)cable,1100 Volts,complete all as specified and directed by Engineer-in-Charge
176Supply and fixingin repair PVC insulated Sheathed, Copper conductor,4 sq mm ,3 core (flexible)cable,1100 Volts,complete all as specified and directed by Engineer-in-Charge
177Material and labour for drain pipe rigid and flexible 20mm dia with clamps of suitable size as per site requirement complete all as specified and directed by Engineer-in-Charge
178M & L for Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and Fix new rotary type compressor with charging of refrigerent after dehydration testing and vaccummingone as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge
179M & L for Disconnecting and taking down burnt compressor of capacity 1.5 TRwith CFC free Refrigerent (R410a,R32) from split type AC unit and Supply and Fix new rotary/reciprocating type compressor with charging of refrigerent after dehydration testing and vaccummingone as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge
180M&L for repair to gas leakage of split type AC unit of capacity 1.5/2TR capacity including pressure testing, dehydration and gas charging complete all as specified and directed by Engineer-in-Charge
181M&L for replacement ofelectronic remote control unit of split type A/C unit (cordless type)1.5 Ton complete of existing makecomplete all as specified and directed by Engineer-in-Charge
182M&L for replacement ofelectronic remote control unit of split type A/C unit (cordless type)2.0 Ton complete of existing makecomplete all as specified and directed by Engineer-in-Charge
183Taking out unserviceable PCB from1.5 /2 TR split type A/C unitand refixing the serviceable PCB after repair from workshop complete testing all as specified & directed by Engineer-in-Charge.
184Taking out unserviceable PCB from1.5 /2 TR inverter split type A/C unitand refixing the serviceable PCB after repair from workshop complete testing complete all as specified and directed by Engineer-in-Charge
185M&L for replacement of unserviceableinverter type PCB from the existing inverter split type A/C unit1.5/2.0Ton complete of existing make ,testingcomplete all as specified and directed by Engineer-in-Charge
186M&L for taking out unserviceableblower motor from split type A/C of capacity 1.5 /2 Ton unitcomplete and supply and fix new blower motor of the existing make complete all as specified and directed by Engineer-in-Charge
187Material and Labour for providing insulation 9mm thick for dia 1/4",3/8",1/2",5/8",6/8" copper tubing’s from Indoor to outdoor units with foam insulation followedwith clamps complete all as specified and directed by Engr-in-charge.
188Supply and charging Refrigerant(R410,R32,R134 and existing refrigerent) to any type of AC unit including CFC free and non CFC Free AC complete all as specified and directed by Engineer-in-Charge
189M&L in replacement of copper tubing 10mm outer dia suitable for AC 2TR capacity complete all as specified and directed by Engineer-in-Charge
190M&L in replacementcopper tubing 15mmouter diacomplete all as specified and directed by Engineer-in-Charge
191M & L for Repair & maintenance of water coolers ofcapacity 40/80/150Ltrs comprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge. (a) Inspection, taking down, opening, dismantling, decaling, brushing cleaning of storage tanks (b) Examination water tightness, leak proof of storage tank after cleaning.(c) Carry out operation of all stop cock, push cock, float valve etc. (d) Inspect overflow and remove blockage if any. (e) Check and correct earth continuity of electric items (f) Check thermostat and test its functioning (g) Inspect drain pipe and remove blockage if any (h) Check and correct all electrical wiring & test its functioning(i) Testing of water cooler after repair
192Supply & fixing in replacement of thermostat switch suitable for water cooler 40/80 as required at site complete all as specified and directed by Engineer-in-Charge
193Supply and Fixing in replacement fan motor capacitor2.5/3.15mfd complete all as specified and directed by Engineer-in-Charge
194Supply & fixing in replacement of starting relay as requiredat site for water coolers 40/80 Ltrs capacity complete including connecting, testing complete all as specified and directed by Engineer-in-Charge
195M & L for Disconnecting & taking out compressor ("R type) from water cooler for any capacity and supply and fix the new compressor including flushing dehydration and gas charging complete all as specified and directed by Engineer-in-Charge
196Supply and fixingin repair PVC insulated Sheathed, Copper conductor,6 sq mm ,3 core (flexible)cable,1100 Volts,complete all as specified and directed by Engineer-in-Charge
197Supply and fixingin repair PVC insulated Sheathed, Copper conductor,4 sq mm ,3 core (flexible)cable,1100 Volts complete all as specified and directed by Engineer-in-Charge
198M & L for Taking down desert cooler of any size by disconnecting electrical supply, cleaning, oiling of all moving part of pump & exhaust fan/kit, Replacing PVC pipes, nozzles, distributors, pads, checking electrical connections complete all as specified and directed by Engineer-in-Charge
199Supply and fixing in replacement of wood pads(set of three)as per sample complete all as specified and directed by Engineer-in-Charge
200Supply and fixing in replacement the new desert cooler pump.including testing for proper functioning complete all as specified and directed by Engineer-in-Charge
201Supply and fixnew exhaust fan kit of desert cooler with super enameled copperwire complete all as specified and directed by Engineer-in-Charge
202M & L for Repair and Maintenance of window type AC"s of capacity 1.5 TR comprising of the following tasks at different locations including Refixing, commissioning and testing complete all as specified and directed by Engineer-in-Charge.(a) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (c) Inspecting the leakage in the system. d) Checking of the earth continuity of electrical parts. e) Checking the functioning of thermostat. f) Inspection of all electrical parts. g) Testing the machine for satisfactory operation.
203S&F in replacement "R" typecompressor for Window type AC,1.5 TR as per existing make andincluding taking out old unserviceable one,flushing, dehydrationand gas changing complete all as specified and directed by Engineer-in-Charge
204S&F in replacement of copper condensor coil of window type AC 1.5 TR including after taking out old unserviceable coil and including dehydration ,charging complete all as specified and directed by Engineer-in-Charge
205Repair & maintenance of Refrigerator of any capacitycomprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge. a) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. c) Inspecting the leakage in the system. d) Checking of the earth continuity of electrical parts. (e) Checking the functioning of thermostat. f) Inspection of all electrical parts. g) Testing the machine for satisfactory operation. (h) Check and correct all electrical wiring & test its functioning (j) Testing of Refrigeratorafter repair.
206M & L for Repair & maintenance of voltage stabilizer ofcapacity 5 KVA comprising of the following tasks at different location complete all as specified and directed by Engr-in-Charge. (a) Rewinding of Transformer copper coil with new copper wire as per existing gauge(b) Time delay relay-01 No.c) Cut out relay-01 No. (d) printed citcuit relay- 01 No.
207M & L for Dismantling of Split type AC 1.5/2.0 TR capacity from position after including disconnecting all connections between indoor and out door units,shifting,backup refrigerant for reuse and install at a place where directed carefully,including cutting on wall,making hole and make good disturbed surface properly matching surface,inspecting,servicing and refilling refrigerant and testing complete all as directed by Engr-In-Charge.
208M & L for Taking out unserviceable indoor unit and supply and fix the newindoor unit of 2 TR capacity split AC 230 Volts single phase including installing ,charging complete all as specified and directed by Engineer-in-Charge
209Supply and fix in repair single pole and netural enclosure with a two pin and earth plug and socketcomplete with one single pole MCB SP 20-32 amps complete all as specified and directed by Engineer-in-Charge
210Supply and fix in repair outdoor unit fan blade for 5.5 TR split AC complete all as specified and directed by Engineer-in-Charge
211Supply and fix in repair outdoor unit fan blade for 2.0/1.5 TR split AC complete all as specified and directed by Engineer-in-Charge
212Supply and fix in replacement copper condensor coil for split AC 2 TR complete all as specified and directed by Engineer-in-Charge
213Supply and fix in replacement copper condensor coil for split AC 1.5 TR complete all as specified and directed by Engineer-in-Charge
214Supply and fix in replacement copper evaporatercoil for split AC 2 TR complete all as specified and directed by Engineer-in-Charge
215Supply and fix in replacement copper evaporater coil for split AC 1.5 TR complete all as specified and directed by Engineer-in-Charge
216M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length) complete all as specified and directed by Engineer-in-Charge
217M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 4 sqmm cable alongwith one run of 2 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length) complete all as specified and directed by Engineer-in-Charge
218S/Fix in replacement MCB DB TPN 4 Way factory made IP 42 protection class metal double doorwith 200 Amp rating bus bar with incomer as 4 pole MCCB 240/430V for fixing of MCBs/Isolators/RCCBs etc completed after dismantling old one complete all as specified and directed by Engineer-in-Charge
219Supply and install in replacement MCCB TPN fixed type 125 Amps rated with breaking capacity 16 KA complete all as specified and directed by Engineer-in-Charge
220Supply& fixing in replacement ofMCB SP 6 t0 32 amps 230 Volt complete all as specified and directed by Engineer-in-Charge
221Supplying and fixingPVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed by Engineer-in-Charge
222S&F in replacement of Casing capping double lock type supper qualitysize 15 mm width ISI marked with fixing accessoriescomplete all as specified and directed by Engineer-in-Charge
223Supply and installation of PVC Duct 100 mm width For AC copper pipes and insulation as specified at site complete all as specified and directed by Engineer-in-Charge
224Supply and install wall mounted stand for mounting indoor unit of split AC complete with all fixing arrangementcomplete all as specified and directed by Engineer-in-Charge
225Supply and install wall mounted stand for mounting outdoor unit of split AC complete with all fixing arrangement complete all as specified and directed by Engineer-in-Charge
226Suply and fix in replacement of Sheet metal enclosure for MCCB 3P, one no complete all as specified and directed by Engineer-in-Charge
227S&F in repair floor mounted TPN busbar chamber outdoor type 3.15 CRCA Sheet factory made with busbar of current rating 400 Amp, 415, 4 way complete all as specified and directed by Engineer-in-Charge
228M&L for scrapping of surface of LT panel feeder piller of any size with emery paper and painting of pole one coat of primer and two coats of white colour paint complete all as specified and directed by Engineer-in-Charge
229M& L for preparationof trench for cable laying of size 300mm x 450 x 10 m long including excavation, brickwork, PCC work , plastering and finishing complete all as specified and directed by Engineer-in-Charge
230Supply and fixedin repair,MCCB 125 Amp,3 pole, adjustable type ,25KA including under voltage/over voltage relay complete all as specified and directed by Engineer-in-Charge
231Supply and fix steel pole tubular swaged 9 metres long complete with cast iron base plate , finialtaper plug , bolts , nuts and screws as specified type 410 SP-22 complete all as specified and directed by Engineer-in-Charge
232M & L cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate for pole pedestal (PCC) including necessary form work etc complete all as specified and directed by Engineer-in-Charge
233M & Lcement concrete in foundation filling and mass concrete type B2 1;2;4 (40mm graded aggregate) complete all as specified and directed by Engineer-in-Charge
234M & Lcement concrete in foundation filling and mass concrete type B2 1:4:8 (40mm graded aggregate)all as directed by Engr-In-Charge
235Taking down unserviceable street light fitting upto 11 mtrs /LED Street Light fitting/Flood light Fitting of any size from the pole/bldg and kept in safe custody for refixing or for schedule of credit to contractor complete all as specified and directed by Engineer-in-Charge Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost
236Refixing and reconnecting up complete LED street light/Flood light fitting after rectification of defects in wiring of the fitting in an including replacement of holders, PVC connector, ballast, ignitor, condesor and lamp and making electric connection with PVC unsheathed wire withold or new conductor withOH line or Bus bar box complete all as specified and directed by Engineer-in-Charge Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost
237Supply and fix in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as specified and directed by Engineer-in-Charge.
238S& fixing LED flood light luminarie70 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed by Engineer-in-Charge
239S& fixing LED flood light luminarie90 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed by Engineer-in-Charge
240S& fixing LED flood light luminarie120 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed by Engineer-in-Charge
241Supply and Fixing LED street light fitting 45 Watt pressure die case aluminium housing LED street light luminaires suitable for existingstreet light pole including all fixing accessaries complete all as specified and directed by Engineer-in-Charge
242Supply and Fixing LED fountain light fitting 6 to 9 Watt luminaires in color as decided by Engineer-in-Charge suitable for existingfountain including all fixing accessaries all as per specified and directed by Engineer-in-Charge.
243Supply and Fixing LED flood light fitting 30 Watt pressure die case aluminium housing LED street light luminaires suitable for existing pole or wall mountedincluding all fixing accessaries all as per specified and directed by Engineer-in-Charge.
244Supply and Fixing LED street light fitting 60 Watt pressure die case aluminium housing LED street light luminaires suitable for existingstreet light pole including all fixing accessaries all as per specified and directed by Engineer-in-Charge.
245Supply and fixin replacement LED bollard fitting 9 Watt with luminaire with MS Pipe housing with glare free PMMA diffuser , IP65 of height 800 mm suitable for single phase connection 50 Hz 230 Volts complete all as specified and directed by Engineer-in-Charge
246Supply and fix single phase driver for LED street light / flood light of 45 to 200 watt capacity and compatible with existing street light/ flood light any type / any rating complete all as specified and directed by Engineer-in-Charge
247S&F in replacement street light GI pipe bracket 50 mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed by Engineer-in-Charge
248Supply and fix in replacement non-metallic junction box/street light boxwith three phase aluminium bus bar of suilable for 415 Volt , 50 Hz electric supplyconforming to IP65 wall / pedestral mounted and including MCB SPN 06 Amps complete all as specified and directed by Engineer-in-Charge
249Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½XLPE, armoured, Al conductor cable of size 16 to 35 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge
250Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed4 core 10 sq. mm nominal cross section in service connections complete all as specified and directed by Engineer-in-Charge
251Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed by Engineer-in-Charge
252Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed2 core 6 sq. mm nominal cross section in service connections complete all as specified and directed by Engineer-in-Charge
253Excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose/soft soil and getting out complete all as specified and directed by Engineer-in-Charge
254Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engineer-in-Charge
255Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engineer-in-Charge
256M & Lfor brick protection with sub class "B" brickslaid dry flat over electric cable in trenches complete all as specified and directed by Engineer-in-Charge
257M & Labour for sand cushioning with a layer of sand 80mm thickconsolidated before laying of cable and 150mm thickconsolidated after laying of cable in trenches ducts for electric cable protection including consolidation complete all as specified and directed by Engineer-in-Charge
258Supply and fixing in repair/replacement of solar street light fittings with integrated 12 Watt LED street light system with solar PV Panel 100 WP, integrated LED fitting with Li-Ion Battery 11.1 V 17 Ah , MPPT based solar charge controller,Motion Sensor and tubular pole of height 5 Mtrs complete all as specified and directed by Engineer-in-Charge.
259Supply and fix in replacement hot dip galvanized decorative pole 6 m height dual arm light fitting outdoor type including 50 watt luminaire with IP66 ratingcomplete all as specified and directed by Engineer-in-Charge
260S&F decorative 45 W LED Strip light including drivers and necessary connections non-integral flexible type with high brihtness for indoor and outdoor applications. Strip can be cut at marked interval to suit desired length complete all as specified and directed by Engineer-in-Charge