Military Engineer Services-MES has published Tender For Repairs Maintenance Of Summer Appliances And Connected Accessories Installed Under Ge Chennai. Submission Date for this Tender is 01-07-2023. Air Conditioner Tenders in chennai Tamil Nadu. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 16-Jun-2023 | CERTAIN AMENDMENTS TO TENDER DOCUMENTS | Other | 24-06-2023 |
2 | 24-Jun-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-07-2023 |
Sl. No. | Item Description |
1 | Window type A/C |
2 | Dismantling the unserviceable uncut hermetically sealed compressor /rotary compressor from the AC unit and replacement with factory re-conditioned hermitically sealed compressor for window Air conditioner of any make including transportion for 1.5 Ton capacity. |
3 | M&L for flushing out of complete condensing and evaporator unit, jointing the compressor suction and delivery tubes including replacement of any description of liquid line, strainer assembly, capillary tubes etc., including rectification of leakage from the systems and line, vaccumising, dehydrating, oil and gas charging , testing and commissioning of system upto 2 TR capacity of window type Air conditioners. NOTE :- (i) The cost deemed included the replacement of spares like coper tubes any description, strainer assly, capillary tubes etc. (ii) The required gas shall be measured and paid under relvant items of this schedule. |
4 | S&F in repairs new condensing unit housing for any given make for window type AC including dismantling the old unserviceable condensing unit. |
5 | S&F in repairs new cooling coil unit housing for any given make for window type AC including dismantling the old unserviceable cooling coil. |
6 | S&F in repairs condenser/ cooling coil housing jointing plate for window AC of any make for 1.5 / 2.0 Ton capacity including dismantling the old unserviceable jointing plate. |
7 | S&F in repairs following spares/ items for window type AC unit of any capacity including dismantling the old unserviceable items :- |
8 | Cooling coil. |
9 | Condenser coil. |
10 | Standard outer cover |
11 | Front panel with grill |
12 | Fan blade set |
13 | Brand new fan motor |
14 | Overload Protector |
15 | Starting relay |
16 | Starting capacitor 80-100 MFD |
17 | Running capacitor 45/ 50 MFD |
18 | S&F for modular 32 Amps motor starter AC switch with two modele one piece including indiacaton both red and green complete all as specified and all as directed. |
19 | Taking out outer cover of 1.5/ 2.0 TR capacity on wall of window, cleaning of all parts/ fittings, washing out of condensing unit with water to remove deposition of materials checking of all parts for smooth functioning carrying out servicing & lubricating of all parts, checking and tightening electrical connections and ensuring complete unit in perfect working condition. |
20 | Split type A/C |
21 | Dismantling the unserviceable uncut hermetically sealed compressorfrom the AC unit and replacement with factory re-conditioned hermetically sealed compressor for split type Air conditioner of any Make including transporting for 1.5 Ton capacity. |
22 | All as per item No. 11.00 above but for 2.0 Ton capacity |
23 | Dismantling the unserviceable uncut rotary compressor from the AC unit and replacement with new rotary compressor 1.5/ 2.0 Ton capacity. Note:-for item 11, 12 & 13:The cost of gas shall be measured and paid separately as supply only. |
24 | M&L for flushing out of complete condensing and evaporator unit, jointing the compressor suction and delivery tubes including replacement of any description of liquid line, strainer assembly, capillary tubes etc., including rectification of leakage from the systems and line, vaccumising, dehydrating, oil and gas charging and testing and commissioning of system upto 2 TR capacity of Split type Air conditioners. NOTE :- (i) The cost deemed included the replacement of spares like coper tubes any description, strainer assly, capillary tubes etc. (ii) The required gas shall be measured and paid under relvant items of this schedule. |
25 | S&F the following spares/ items for split type AC 1.5 Ton capacity including dismantling the old unserviceable spares/ items |
26 | Remote control. |
27 | Electronic PCB Board |
28 | Electronic PCB Board for Inverter AC |
29 | Fan motor 1/6HP capacity. |
30 | Condenser coil |
31 | Cooling Coil |
32 | Suction valve |
33 | Discharge valve |
34 | PVC conduit pipe 20mm dia including all accessories to drain out pipe |
35 | Indoor unit blower motor of 1.5/ 2.0 tonsplit type AC |
36 | Starting relay |
37 | Starting capacitor 80-100 MFD |
38 | Running capacitor 45/50 MFD |
39 | Fan blade set |
40 | Air filter suitable for air conditioner 1.5 /2.0Ton capacity |
41 | Taking out outer cover of 1.5/ 2.0 TR capacity Condensing unit on wall/ floor of split type AC for repairing, cleaning of all parts/ fittings, washing out of condensing unit with water to remove deposition of materials checking of all parts for smooth functioning carry out servicing & lubricating of all parts, checking and tightening electrical connections and ensuring complete unit in perfect working condition. |
42 | Installation of split type Air conditioner any capacity including Supply & fixing factory fabricated support suitable to mount out door unit (one pair per AC) and duly making holes into wall for insertion of copper pipe, drain pipe and 3 core cable and making good the disturbed surfaces. Note: This item to be operated for change of location only, as split type AC unit to be shifted from one location to other location. |
43 | Supply and fix Indoor unit of split type AC 1.5/2.0 Ton capacity |
44 | REFRIGIRATOR |
45 | Dismantling the unserviceable uncut hermetically sealed compressor from the Refrigerator unit and replace with factory re-conditioned hermetically sealed compressor for refrigerator of any make 180 ltrs to 400 ltrs capacity. Note: Gas charging will be measured and paid separately. |
46 | Supply only Gas R - 134 A |
47 | Supply only Gas R - 32 |
48 | Supply only Gas R - 410 A / R-22 |
49 | M&L for flushing out of complete condensing and evaporator unit, jointing the compressor suction and delivery tubes including replacement of any description of liquid line, strainer assembly, capillary tubes etc., including rectification of leakage from the systems and line, vaccumising, dehydrating, oil and gas charging and testing and commissioning of system upto 180 to 400 ltr.cooling capacity NOTE :- (i) The cost deemed included the replacement of spares like coper tubes any description, strainer assly, capillary tubes etc. (ii)The required gas shall be measured and paid under relvant items of this schedule. |
50 | S&F the following spares/ items for 180 to 400 ltrs Refrigerator including dismantling the old unserviceable spares/ items |
51 | Relay box type |
52 | Over load protector 1/6HP |
53 | Thermostat defrosting type |
54 | Door magnetic gasket |
55 | Cooling coil |
56 | Condenser coil |
57 | Freezer door |
58 | Vegetable tray with glass |
59 | New frost free motor |
60 | Renewal of entire portion of base plate and legs, welding with proper gauge new MS sheet complete all as directed and specified of refrigerators capacity 180 to 400 ltrs |
61 | Taking out refrigerators for servicing by cleaning all parts/ fittings, washing out of condensing unit with water to remove deposition of materials checking of all parts for smooth functioning carrying out servicing & lubricating of all parts, checking and tightening electrical connections and ensuring complete unit in perfect working condition. |
62 | VOLTAGE STABILIZER |
63 | Taking out the voltage stabilizer of capacity 4 KVA & 5 KVA of any make and of following capacity from AGE E/M store yard and transporting to work shop, to detect/ identify the nature of defects/ repairs and reassembling after repair/ servicing commissioning at site and testing complete etc., & all as directed and specified for following capacity:- |
64 | All as per item No. 29.00 above but of2 KVA & 3 KVA capacity |
65 | M&L in replacement Sub main wiring with two single run of single core PVC insulated cable with copper conductor multistranded 1100 volts grade 4 sqmm through and including with suitable size of PVC rigid conduit and its accessories, surface/ ceiling along with fixing arrangements etc., including 4.0 sqmm PVC insulated multistranded copper earth continuity conductor and connected to common earth dolly complete all as specified and directed. Note: - (i) Two runs of cable, one/ two runs of earth conductor cable and one run of PVC conduit shall be measured as one unit. (ii) The cost deemed to be included for cutting and chasing and making good the disturbed surfaces. |
66 | All as per item No. 31.00 above but but with 2 runs of 6 sqmm |
67 | S & F three core flexible cord copper wire of size 3 Core 4 Sqmm suitable forall summer applainceas directed & specified. |
68 | S&F the following copper pipes for all summer appliances of any capacity including dismantling the unserviceable pipe. |
69 | Copper pipe 1/2" dia |
70 | Copper pipe 3/8" dia |
71 | Copper pipe 5/8" dia |
72 | Copper pipe 1/4" dia |
73 | WATER COOLER / DEEP FREEZERS |
74 | Taking down carefully, dismantling and opening the Water coolers / Deep Freezers of any capacity / any make after disconnecting the electric connection for attending repairs, reassembling, refixing and re-connecting the Water coolers / Deep Freezers to power point / connector after necessary servicing and replacing the spare parts etc., complete all as specified and directed. Note : (i) Servicing and replacing the spare parts shall be measured and paid separetely. (ii) In specific cases involving shifting to workshop and returning to work site, the same will be measured and paid separetely. |
75 | Rewinding the blower fan motor of water coolers of any Make with super enamelled copper wire of same existing (original) size to get design speed for the particular make of fan motor including insulating varnishing, providing sleeves to copper wire ends all as specified and directed for the capacity of fan motor 1/5 HP (for 150 litres water cooler). |
76 | All as per item No.37.00 above but, fan motor 1/16 HP (for 120 litres water cooler) |
77 | All as per item No.37.00 above but, fan motor 1/32 HP (for 80 litres water cooler) |
78 | Flushing the complete condensing unit, Cooling coil unit and replacement of liquid lines,Strainer / drier capillary tubes etc., and rectification of leakage from the system, Vacumising, dehydrating oil and gas chargingincluding testing and commissioning complete and all as specified and directed for the water cooler of capacity 150 litres.Make : Usha/Blue Star/Sidwal/Voltas Note :Freon Gas for charging shall be measured and paid separately. |
79 | All as per item No.40.00 above but, water cooler of capacity120 Litres |
80 | All as per item No.40.00 above but, water cooler of capacity 80 Litres |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail