Tender For Tiruvannamalai Municipality - Providing Camp Office At Municipal Commissioner Quarters Permissies, thiruvannamalai-Tamil Nadu

Tiruvannamalai Municipality-agecode007 has published Tender For Tiruvannamalai Municipality - Providing Camp Office At Municipal Commissioner Quarters Permissies. Submission Date for this Tender is 08-06-2023. Building Work Tenders in thiruvannamalai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

37998298
Tender For Tiruvannamalai Municipality - Providing Camp Office At Municipal Commissioner Quarters Permissies
Open Tender
Indian
Tamil Nadu
thiruvannamalai
08-06-2023

Tender Details

Tiruvannamalai Municipality - Providing Camp Office At Municipal Commissioner Quarters Permissies Providing Camp Office At Municipal Commissioner Quarters Permissies

Key Value

Document Fees
Refer document
EMD
INR 2560.0 /-
Tender Value
INR 2.56 Lakhs /-

BOQ Items

Name of the work : Providing Camp Office at Municipal Commissioner Quarters permissiesin Tiruvannamalai Municipality
Sl. No. Item Description
1Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9" X 43/8"X 23/4" including finishing, curing, etc., complete complying with standard specification - 100CFT
2Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
3Paving the floor with design Anti skit ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement
4Providing and fixing Bitumen Pad for Expansion joint in between pavement slabs to 12mm thick and fixed as shown in the drawing including cost and conveyence of expansion joints including shalimar pad and joint sealent etc, complete as per standard specification
5Supplying and fixing of SS False Ceiling using Fire Retardant Galvanized Steel Sheet Plain lay in tile size 600mm x 600mm, 0.5mm thick, powder coated on external surface and shall have flange on all four sides to rest on the exposed grids. The system to give 600mm x 600mm centre to centre "T". The "T" shall be not be dipped GI Tee Section 3600mm long main Tee. 24mm wide and cross Tee panels are formed by running main runner of "T" section of size 30mm x 24mm powder coated at bottom at intervals with powder coating at bottom. Necessary provision of inter locking of "T" section are made at required intervals not exceeding 1200mm. The main runners are suspended from the ceiling by means of 4mm dia. GI rods fixed to the ceiling using anchor fasteners of 50mm x 8mm size with nylon inset and hooked to the main rubbers using clips. The last hangers at end of each rubber should not be greater than 600mm from the adjacent wall. The last panel shall be placed at the side wall using edge profile "L" Angle of size 20mm x 20mm and fixed to the side wall the false ceiling should be fixed of same level and should present a neat look PwD SOR 22-23 pg-67
6Supplying and fixing the Wall Panelling with the following specification fixing horizontally and vertically in position of wall. Fixing the water proof ply wood 9mm thick board over the country wood planks. Over the ply wood OST sheet of 4mm thick will be fixed with necessary screws and fevicol giving neat finsih. The top will be finished with two coats of sanding polishing. The surface will be finished with necessary design as directed by the Departmental Officers. The rate inclusive of all materials, labour power and conveyance of materials to the work site, loading & unloading etc., and as per drawing and design by the Departmetnal Officers. The water proof ply wood and OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. PwD SOR 22-23 pg 69
7Wiring with 2x1.5sqmm (22/0.3) PVC insulated unsheathed SC Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A F.T. switch in flush with wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (For electronic regulator). (SD-24)
8Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150 mm x 100 mm x 113mm TW switch box in flush with wall with 3 mm thick Hylem sheet cover for 5 A 3 pin non inter locking CS plug with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC plug point. (SD-37)
9Supply and fixing of PVC Solid Doors using 19gauge 19mm MS Sq,tubes for styles and frames, 15mm MS Sq.tubes for to, Lock and bottom rails. The Steel Tubes shall be covered with 5mm thick Solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in positionincluding furniture and fittings. The over all size of styles shall be 50mm X 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm X 30mm. The over all size of frames shall be 50mm X 45mm with suitable tabate for housing the shutter etc, complete as per standard specification.
10Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the executive Engineer before use on work
11CONFERENCE TYPE PUBLIC ADDRESS SYSTEM,PROJECTOR AND MOTORIZED SCREEN UNARMOURED LAN & CCTV CABLE INTERNET CABLE