Health and Family Welfare Government Departments Closing in 0 days TDR #37995564

Tender For Electrical Installation Works For Site Preparation Activity Under Diagnostic Infrastructure To Phcs At Kapgari Phc, Jamboni Block, Jhargram..

Issued by Government Departments · jamboni, West Bengal
Tender Value
4.60 Lakhs
Estimated cost
Bid Submission
12 Jun 2023
0 days left
EMD
9210
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jamboni → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Electrical Installation Works For Site Preparation Activity Under Diagnostic Infrastructure To Phcs At Kapgari Phc, Jamboni Block, Jhargram..

BOQ

Name of Work:Electrical Installation works for site preparation activity under Diagnostic Infrastructure to PHCsat Kapgari PHC, Jamboni block, Jhargram
Sl. No. Item Description
1SUB-HEAD I: INTERNAL WIRING
2All wiring Item including provision of conduit, conduit accsories , circuit wiring, switch, box and all fitting completed as required.
3INTERNAL WIRING
4Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required (Make:-Havells/Polycab/RR Kable)
52 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [Separate 6A & Point wiring (if required)]
62 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [Separate 20A & CPU Board]
72 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [6+20A DB & UPS DB]
82 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC [PDB 1,2 to LDB 1,2]
9Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\"(Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switchfixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish(Make:-Havells/Finolex/KEI)
10Average run 5 mtr
11Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and makingnecy. connection as required
122 x 126/0.4 (16 sqmm) [D.G. Neutral Earthing]
13Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
142.5 sqmm
154 sqmm
166 sqmm
1716 sqmm
18SWITCH BOARDS
19Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [Separate 6A Plug Point]
20Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [Separate 20A Plug Point]
21Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [CPU Board]
22Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [Power Board]
23Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. [UPS Incomer & Outgoing Board]
24PANEL & DISTRIBUTION BOARDS
25Supply of 2 mm thick wooden ply board of size 3 ftx2 ft and fixing the same in wall by necessary nuts, bolts etc. Incl. Supply and fixing of 3 nos. 100A, 415V, Porcelain Fuse carried and base (Havells make, cat no: IHKKRN4100) and neutral bar at wooden board.
26Main LT Panel :- Supply, delivery, installation, testing & commissioning of Indoor Cubical type L.T. Distribution panel board of required size, wall/stand mounted compartmentalized with maple arrangement having rigid & self supporting structure with cable alley fabricated from 2 mm thick CRCA sheet steel and 35x35x5 mm M.S. angle frame for panel mounting support and making necessary grouting arrangements with neet cementing finish as per direction of EIC. [Dim. - 1450mm x 1050mm x 450mm]. The panel board consisting of the following item:-
27415V, 200A electrolyte grade tinned copper BBC with vertical section of 25X6mm sizefor neutral & Phases. Bus-bar shall be fixed with FRP insulator chair & seperator & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C. [equal bar for each i.e. 4-bar]and interconnections for:- 125A SFU and all inter-connecting links should be made with suitable size copper strip/copper wire.
28A) Incomming Arrangement: a) 415V 50 Hz 125A TPN SFU (panel mounting cubicle type) conforming to IS 13947 in open execution three pole & neutral, Make- Legrand/Havells/ABB -01 no.B) Bus Section:415V, 200A electrolyte grade tinned copper bus bar, with vertical section of size 25x6mm for Phase RYB, neutral bars of each. A bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C.C) Outgoing Arrangement:a) 415V 125A TPN SFU (Switch disconnector fuse), panel mounting cubicle type conform to IS :13947, in open execution three pole & neutral with 3 nos. 125 Amp DIN type HRC fuse link, Make- Legrand/Havells/ABB -03 nos.b) 415V 125A TPN On load Changeover switch, front operated Changeover switch in open execution type, Make- Legrand/Havells/ABB -01 no. D) Metering Panel:a) S&F 3-ph digital single function panel meter, Voltmeter (L&T)- 01 no.b) S&F 3-ph digital single function panel meter, Ammeter (L&T) - 01 no.c) S&F 200/5A 15VA Class-1 C.T. (KAPPA) -03 nos. d) S&F Gen next LED phase R-Y-B indicator-Make-L&T 03 nos. e) S&F 6A SP MCB (c-curve)-Make-Havells 03 nos.f) S&F 08\"X06\" Danger Board01 no.E) Cable Alley:Cable entry arrangement will be provided in the cubicle panel in vertical position of size 1450mm x 250mm x 450mm with suitable capacity 4 way AC/DC connector indicating phase & neutral for each outgoing main switches & gland plate must be placed at the bottom of the panel with detachable type as per direction of E.I.C.F) Painting:The complete panel board shall be painted by 2 coats of powder coated synthetic enamel paint over two coats of R.O. primer of Approved make & brand & color as per Direction of E.I.C.
29G) Constructional Details:All incoming & outgoing panel mounted cubicle switch disconnector fuse shall be housed in respective compartment with hinged & gasketted door at front, All doors shall have panel lock arrangement. The panel shall be properly gasketted to prevent ingress of dust & moisture & remain. Busbar will be properly arrange & all switches shall be fixed by M.S. nuts & bolts on angle iron/flat iron frame base as per direction of E.I.C.
30VTPN D.B
31Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending goodthe damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand / Havells / Siemens).
326 way Enclosure (upto 160A) (8GB31572RC) [MNDB]
33TPN D.B
34Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand / Havells / Siemens).
356 way Enclosure (8GB32202RC06) [PDB 1,2]
36SPN D.B
37Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Legrand / Havells / Siemens).
382+4 way Enclosure [MEDB]
392+12 way Enclosure [EDB 1,2]
402+12 way Enclosure [LDB 1,2]
41Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts boltsetc incl. provision for earthing attachment
426 Way Horizontal
436 Way Vertical
44MCCB
45Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (Legrand / Havells/Siemens).
46100 A [Make-Legrand/Siemens/Havells] [VTPN I/C]
47MCB
48Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Havells / Siemens).
49Single Pole 6-32A MCB [MNDB, MEDB, PDB 1,2, LDB 1,2, EDB 1,2 O/G]
50Single Pole 25A-32A MCB [MNDB O/G - UPS, PUMP, SPARE]
51Double Pole 32A MCB [LDB 1,2, MEDBI/C]
52Double Pole 25A MCB [EDB 1,2 I/C]
53Triple Pole 63A MCB [MNDB O/G - PDB 1,2]
54TPN 63A MCB [PDB 1,2 I/C]
55CABLE MAIN, LAYING AND FINISHING OF CABLE
56Laying on Wall / surface with Saddles / clamps
57Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
58Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
59Laying through Underground Trech
60Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
61CABLE TERMINATION
62Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
63For 4 core upto 35 sqmm
64For 4 core upto 25 sqmm
65Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
664 core 25 sqmm cable
674 core 35 sqmm cable
68Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
6950 mm dia ISI
70SUPPLY OF CABLE
71Supplying of 1.1 KV. Grade XLPE insulated aluminium armoured conductor of following make: Polycab/Gloster/Havells/RR Kable:-25 sqmm 4 core
72Supplying of 1.1 KV. Grade XLPE insulated aluminium armoured conductor of following make: Polycab/Gloster/Havells/RR Kable:-35 sqmm 4 core
73LIGHT FITTING:
74Supplying & Fixing Out door type CFL luminaire (Bajaj make- 524020 / 020168) with epoxy powder coated sheet aluminium housing, aluminium reflector & clear acrylic cover and accessories incl. for 11/18 watts CFL S/L type lamp incl. S&F 15mm dia GI pipe bracket, clamp, nut & bolts etc..[Near DG shed]
75Supply & Delivery at site 9 watt LED Bulb,Efficacy>=90 lm/W, Base Cap:-B22 [Make-Crompton] or equivalent of Havells, Philips etc. [Approved by EIC]
76Fixing only lamp
77EARTHING:
78Excavation of soil for installation of Earth Electrode and filling & ramming.
79For Morrum Soil
80Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
81By TATA-Medium GI pipe [D.G. Body:2, D.G. Neutral: 2, VTPN DB:1, UPS Neutral: 1]
82Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
83Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
84Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
85Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
86Solid GI wire
87No. 6 SWG
88Supply & fixing of unipolar hexagonal flat mounting insulator for busbar support for fixing of neutral earth busbar at the side of D.G. foundation & location of UPS of the following specification:-i). Polyester without halogenii) UL94 VO self-extinguishing.iii) Colour red RAL 3002.iv) Operating temperature from -40 to +130°C.v) Deformation under load temperature (ASTM D643): > 200°C.vi) Dielectric constant (ASTM D150): 4/5.vii) Arc resistance (ASTM D495): > 180 s.viii) Water absorption (ASTM D570): < 0.3%.
89DG BASE and FENCING AND SHED
90Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
91a) Depth of excavation not exceeding 1,500 mm.
92a) Foundation footings
93Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)
94a) With earth obtained from excavation of foundation.
95A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement of finished quantity)
96Do by Fine sand
97i) For Found
98For Base
99Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
100a) Foundation
101b)For Base
102Approach Road
103Cement concrete (1:3:6 proportion) with graded stone ballast (40 mm. size) excluding shuttering.
104a) [Pakur Variety]
105i) In Ground floor
106i) For Found
107For Base
108Approach Road
109Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes
110a) M-20 grade with Pakur variety
111i) In ground floor and foundation.
112For Base
113Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.
114a) Other than SAIL/TATA/RINL
115i) In foundation & ground floor
116Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works.
11725 30 mm wooden shuttering
118i) In foundation & ground floor
119Approach Road
120Brick work with 1st classBricks with cement morter (1:6)
121i) In Foundation & Plinth
122Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.
123a) 20 mm. thick plaster (6:1)
124i) In ground floor, Out side
1251.5 mm thick Net cement finish in wall, dado,
126Base
127Applying Exterior grade Acrylic primer of approved quality andbrand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish)
128a) One Coats, Gr. Fl
129Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.
130In Ground floor (Two Coat)
131a) Normal Acrylic Emulsion
132M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected toone another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting torequisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approvedmake and brand conforming to IS:814- 2004, haulage, hoisting anderection all complete
133i) For trusses spanning up to 12.00 m
134Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yieldstrength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be madeon area of finished work)
135(i) In Roof:- a) With 0.5 mm thick sheet
136Aluminium sheet ridging fitted with self tapping screws,EPDM washers etc complete.(Minimum 225mm end lapping).
137(A) 300 mm lapping each way
138(a) With 0.71 mm sheet
139(i) In Roof
140Supplying fitting and fixing I.R.C. fabric mesh with covering battens including cost of screws etc complete (excluding the cost of battens).In ground floor
141(f) 75mm x75mm x 4.5mm x 4.5mm.
142Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than150mm apart complete in all respect as per design including cost of all labour and materials
143(a) M.S.or W.I. Ornamental grill of approved design joints contin uously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.
144(i) Grill weighing above 10 Kg ./sq .mtr and up to 16 Kg./sq. mtr.
145District Charge @3%
146Add GST @18% for the whole work
147Add CESS @1% for the whole work

AI Tender Summary

OUR REF NO 37995564
AUTHORITY Government Departments
TENDER VALUE 4.60 Lakhs
LAST DATE 12-06-2023
Authority
Authority Name Health And Family Welfare Department
Work Description Tender For Electrical Installation Works For Site Preparation Activity Under Diagnostic Infrastructure To Phcs At Kapgari Phc, Jamboni Block, Jhargram..
Basic Detail
Tender No DH FWS/JGM/2023/1233
Bidding Type Tender
Location
City jamboni
State West Bengal
Key Dates
Publish Date 03 Jun 2023
Submission Date 12 Jun 2023
Open Date 14 Jun 2023
Finance
Tender Value 4.60 Lakhs
Tender Fee Ref. Documents
EMD 9210
Exemption Not Available
Document List
Tendernotice_1.pdf
36eddb00-b159-4bbf-ba80-3f01933934f4.html
BOQ_1117971.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 03, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 12, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 14, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

36eddb00-b159-4bbf-ba80-3f01933934f4.html

xls

BOQ_1117971.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders