Tender For Electrical Installation Works For Site Preparation Activity Under Diagnostic Infrastructure To Phcs At Kapgari Phc, Jamboni Block, Jhargram..
Tender Value
4.60 Lakhs
Estimated cost
Bid Submission
12 Jun 2023
0 days left
EMD
9210
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
jamboni → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Electrical Installation Works For Site Preparation Activity Under Diagnostic Infrastructure To Phcs At Kapgari Phc, Jamboni Block, Jhargram..
BOQ
| Sl. No. | Item Description |
| 1 | SUB-HEAD I: INTERNAL WIRING |
| 2 | All wiring Item including provision of conduit, conduit accsories , circuit wiring, switch, box and all fitting completed as required. |
| 3 | INTERNAL WIRING |
| 4 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required (Make:-Havells/Polycab/RR Kable) |
| 5 | 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [Separate 6A & Point wiring (if required)] |
| 6 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [Separate 20A & CPU Board] |
| 7 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [6+20A DB & UPS DB] |
| 8 | 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC [PDB 1,2 to LDB 1,2] |
| 9 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\"(Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switchfixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish(Make:-Havells/Finolex/KEI) |
| 10 | Average run 5 mtr |
| 11 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and makingnecy. connection as required |
| 12 | 2 x 126/0.4 (16 sqmm) [D.G. Neutral Earthing] |
| 13 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 14 | 2.5 sqmm |
| 15 | 4 sqmm |
| 16 | 6 sqmm |
| 17 | 16 sqmm |
| 18 | SWITCH BOARDS |
| 19 | Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [Separate 6A Plug Point] |
| 20 | Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [Separate 20A Plug Point] |
| 21 | Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [CPU Board] |
| 22 | Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [Power Board] |
| 23 | Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. [UPS Incomer & Outgoing Board] |
| 24 | PANEL & DISTRIBUTION BOARDS |
| 25 | Supply of 2 mm thick wooden ply board of size 3 ftx2 ft and fixing the same in wall by necessary nuts, bolts etc. Incl. Supply and fixing of 3 nos. 100A, 415V, Porcelain Fuse carried and base (Havells make, cat no: IHKKRN4100) and neutral bar at wooden board. |
| 26 | Main LT Panel :- Supply, delivery, installation, testing & commissioning of Indoor Cubical type L.T. Distribution panel board of required size, wall/stand mounted compartmentalized with maple arrangement having rigid & self supporting structure with cable alley fabricated from 2 mm thick CRCA sheet steel and 35x35x5 mm M.S. angle frame for panel mounting support and making necessary grouting arrangements with neet cementing finish as per direction of EIC. [Dim. - 1450mm x 1050mm x 450mm]. The panel board consisting of the following item:- |
| 27 | 415V, 200A electrolyte grade tinned copper BBC with vertical section of 25X6mm sizefor neutral & Phases. Bus-bar shall be fixed with FRP insulator chair & seperator & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C. [equal bar for each i.e. 4-bar]and interconnections for:- 125A SFU and all inter-connecting links should be made with suitable size copper strip/copper wire. |
| 28 | A) Incomming Arrangement: a) 415V 50 Hz 125A TPN SFU (panel mounting cubicle type) conforming to IS 13947 in open execution three pole & neutral, Make- Legrand/Havells/ABB -01 no.B) Bus Section:415V, 200A electrolyte grade tinned copper bus bar, with vertical section of size 25x6mm for Phase RYB, neutral bars of each. A bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C.C) Outgoing Arrangement:a) 415V 125A TPN SFU (Switch disconnector fuse), panel mounting cubicle type conform to IS :13947, in open execution three pole & neutral with 3 nos. 125 Amp DIN type HRC fuse link, Make- Legrand/Havells/ABB -03 nos.b) 415V 125A TPN On load Changeover switch, front operated Changeover switch in open execution type, Make- Legrand/Havells/ABB -01 no. D) Metering Panel:a) S&F 3-ph digital single function panel meter, Voltmeter (L&T)- 01 no.b) S&F 3-ph digital single function panel meter, Ammeter (L&T) - 01 no.c) S&F 200/5A 15VA Class-1 C.T. (KAPPA) -03 nos. d) S&F Gen next LED phase R-Y-B indicator-Make-L&T 03 nos. e) S&F 6A SP MCB (c-curve)-Make-Havells 03 nos.f) S&F 08\"X06\" Danger Board01 no.E) Cable Alley:Cable entry arrangement will be provided in the cubicle panel in vertical position of size 1450mm x 250mm x 450mm with suitable capacity 4 way AC/DC connector indicating phase & neutral for each outgoing main switches & gland plate must be placed at the bottom of the panel with detachable type as per direction of E.I.C.F) Painting:The complete panel board shall be painted by 2 coats of powder coated synthetic enamel paint over two coats of R.O. primer of Approved make & brand & color as per Direction of E.I.C. |
| 29 | G) Constructional Details:All incoming & outgoing panel mounted cubicle switch disconnector fuse shall be housed in respective compartment with hinged & gasketted door at front, All doors shall have panel lock arrangement. The panel shall be properly gasketted to prevent ingress of dust & moisture & remain. Busbar will be properly arrange & all switches shall be fixed by M.S. nuts & bolts on angle iron/flat iron frame base as per direction of E.I.C. |
| 30 | VTPN D.B |
| 31 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending goodthe damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand / Havells / Siemens). |
| 32 | 6 way Enclosure (upto 160A) (8GB31572RC) [MNDB] |
| 33 | TPN D.B |
| 34 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand / Havells / Siemens). |
| 35 | 6 way Enclosure (8GB32202RC06) [PDB 1,2] |
| 36 | SPN D.B |
| 37 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Legrand / Havells / Siemens). |
| 38 | 2+4 way Enclosure [MEDB] |
| 39 | 2+12 way Enclosure [EDB 1,2] |
| 40 | 2+12 way Enclosure [LDB 1,2] |
| 41 | Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts boltsetc incl. provision for earthing attachment |
| 42 | 6 Way Horizontal |
| 43 | 6 Way Vertical |
| 44 | MCCB |
| 45 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (Legrand / Havells/Siemens). |
| 46 | 100 A [Make-Legrand/Siemens/Havells] [VTPN I/C] |
| 47 | MCB |
| 48 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Havells / Siemens). |
| 49 | Single Pole 6-32A MCB [MNDB, MEDB, PDB 1,2, LDB 1,2, EDB 1,2 O/G] |
| 50 | Single Pole 25A-32A MCB [MNDB O/G - UPS, PUMP, SPARE] |
| 51 | Double Pole 32A MCB [LDB 1,2, MEDBI/C] |
| 52 | Double Pole 25A MCB [EDB 1,2 I/C] |
| 53 | Triple Pole 63A MCB [MNDB O/G - PDB 1,2] |
| 54 | TPN 63A MCB [PDB 1,2 I/C] |
| 55 | CABLE MAIN, LAYING AND FINISHING OF CABLE |
| 56 | Laying on Wall / surface with Saddles / clamps |
| 57 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 58 | Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting |
| 59 | Laying through Underground Trech |
| 60 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed |
| 61 | CABLE TERMINATION |
| 62 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : |
| 63 | For 4 core upto 35 sqmm |
| 64 | For 4 core upto 25 sqmm |
| 65 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials |
| 66 | 4 core 25 sqmm cable |
| 67 | 4 core 35 sqmm cable |
| 68 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required |
| 69 | 50 mm dia ISI |
| 70 | SUPPLY OF CABLE |
| 71 | Supplying of 1.1 KV. Grade XLPE insulated aluminium armoured conductor of following make: Polycab/Gloster/Havells/RR Kable:-25 sqmm 4 core |
| 72 | Supplying of 1.1 KV. Grade XLPE insulated aluminium armoured conductor of following make: Polycab/Gloster/Havells/RR Kable:-35 sqmm 4 core |
| 73 | LIGHT FITTING: |
| 74 | Supplying & Fixing Out door type CFL luminaire (Bajaj make- 524020 / 020168) with epoxy powder coated sheet aluminium housing, aluminium reflector & clear acrylic cover and accessories incl. for 11/18 watts CFL S/L type lamp incl. S&F 15mm dia GI pipe bracket, clamp, nut & bolts etc..[Near DG shed] |
| 75 | Supply & Delivery at site 9 watt LED Bulb,Efficacy>=90 lm/W, Base Cap:-B22 [Make-Crompton] or equivalent of Havells, Philips etc. [Approved by EIC] |
| 76 | Fixing only lamp |
| 77 | EARTHING: |
| 78 | Excavation of soil for installation of Earth Electrode and filling & ramming. |
| 79 | For Morrum Soil |
| 80 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: |
| 81 | By TATA-Medium GI pipe [D.G. Body:2, D.G. Neutral: 2, VTPN DB:1, UPS Neutral: 1] |
| 82 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 83 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 84 | Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 85 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages |
| 86 | Solid GI wire |
| 87 | No. 6 SWG |
| 88 | Supply & fixing of unipolar hexagonal flat mounting insulator for busbar support for fixing of neutral earth busbar at the side of D.G. foundation & location of UPS of the following specification:-i). Polyester without halogenii) UL94 VO self-extinguishing.iii) Colour red RAL 3002.iv) Operating temperature from -40 to +130°C.v) Deformation under load temperature (ASTM D643): > 200°C.vi) Dielectric constant (ASTM D150): 4/5.vii) Arc resistance (ASTM D495): > 180 s.viii) Water absorption (ASTM D570): < 0.3%. |
| 89 | DG BASE and FENCING AND SHED |
| 90 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. |
| 91 | a) Depth of excavation not exceeding 1,500 mm. |
| 92 | a) Foundation footings |
| 93 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) |
| 94 | a) With earth obtained from excavation of foundation. |
| 95 | A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement of finished quantity) |
| 96 | Do by Fine sand |
| 97 | i) For Found |
| 98 | For Base |
| 99 | Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. |
| 100 | a) Foundation |
| 101 | b)For Base |
| 102 | Approach Road |
| 103 | Cement concrete (1:3:6 proportion) with graded stone ballast (40 mm. size) excluding shuttering. |
| 104 | a) [Pakur Variety] |
| 105 | i) In Ground floor |
| 106 | i) For Found |
| 107 | For Base |
| 108 | Approach Road |
| 109 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes |
| 110 | a) M-20 grade with Pakur variety |
| 111 | i) In ground floor and foundation. |
| 112 | For Base |
| 113 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. |
| 114 | a) Other than SAIL/TATA/RINL |
| 115 | i) In foundation & ground floor |
| 116 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. |
| 117 | 25 30 mm wooden shuttering |
| 118 | i) In foundation & ground floor |
| 119 | Approach Road |
| 120 | Brick work with 1st classBricks with cement morter (1:6) |
| 121 | i) In Foundation & Plinth |
| 122 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary. |
| 123 | a) 20 mm. thick plaster (6:1) |
| 124 | i) In ground floor, Out side |
| 125 | 1.5 mm thick Net cement finish in wall, dado, |
| 126 | Base |
| 127 | Applying Exterior grade Acrylic primer of approved quality andbrand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) |
| 128 | a) One Coats, Gr. Fl |
| 129 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. |
| 130 | In Ground floor (Two Coat) |
| 131 | a) Normal Acrylic Emulsion |
| 132 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected toone another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting torequisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approvedmake and brand conforming to IS:814- 2004, haulage, hoisting anderection all complete |
| 133 | i) For trusses spanning up to 12.00 m |
| 134 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yieldstrength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be madeon area of finished work) |
| 135 | (i) In Roof:- a) With 0.5 mm thick sheet |
| 136 | Aluminium sheet ridging fitted with self tapping screws,EPDM washers etc complete.(Minimum 225mm end lapping). |
| 137 | (A) 300 mm lapping each way |
| 138 | (a) With 0.71 mm sheet |
| 139 | (i) In Roof |
| 140 | Supplying fitting and fixing I.R.C. fabric mesh with covering battens including cost of screws etc complete (excluding the cost of battens).In ground floor |
| 141 | (f) 75mm x75mm x 4.5mm x 4.5mm. |
| 142 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than150mm apart complete in all respect as per design including cost of all labour and materials |
| 143 | (a) M.S.or W.I. Ornamental grill of approved design joints contin uously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. |
| 144 | (i) Grill weighing above 10 Kg ./sq .mtr and up to 16 Kg./sq. mtr. |
| 145 | District Charge @3% |
| 146 | Add GST @18% for the whole work |
| 147 | Add CESS @1% for the whole work |
AI Tender Summary
Tender Timeline
Jun 03, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedJun 12, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJun 14, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender