Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-07-2023 | Clause Amendment | Other | 04-08-2023 |
| 2 | 28-07-2023 | Date Extend | Date | 04-08-2023 |
| 3 | 14-07-2023 | Date Revised | Date | 28-07-2023 |
| 4 | 04-07-2023 | Final RFP | Technical Bid | 14-07-2023 |
| 5 | 04-07-2023 | Revised BoQ | BOQ | 14-07-2023 |
| Sl. No. | Item Description |
| 1 | Double Uneven Leaf Fire Rated steel Door withVision Panel: SS ball bearing butt hinges, lock, SS lever with the internal thumb turn & external key operation with heavy duty door closer |
| 2 | Single Leaf Fire Rated Door with Vision Panel: SS ball bearing butt hinges, lock, SS lever with the internal thumb turn & external key operation with heavy duty door closer |
| 3 | Tile puller |
| 4 | BMS and IT support Staff work station: 60 mm tile based system including tiles.Height of system will be 1200mm.System has one MDF Marker board & one fabric pinup board inner side above worksurface & metal tile below worksurface at inner 1 mm thick CRCA. side.System has metal tile at outer side. Work top size 1200mmX600 mm.Table tops are of 25mm thick & gable ends are of 18 mm thick pre-laminated particleboards icroproce to IS:12823 interior board confirming to IS:12823 interior grade with matching pvc edge banding. All the exposed edges are sealed with 2mm thick imported pvc edge banding on sides & bottoms. The top & drawer facia are sealed with 2mm thick pvc edge. The drawer unit consists of 2 box drawer & 1 file drawer. The sides of inside drawer box are of prelam particle board. The drawer box is fitted with roller slide for free movement. The drawer unit is provided with central locking system, where in the three drawer are locked with one key. PVC recessed handles are provided for easy opening and closing of drawer. The drawer unit is fitted on casters (optional) for easy mobility. The complete furniture unit is factory assembled with knock down fittings. The pedestrial is lifted with additional (5th) castor to avoid icropro of pedestral in case of opening of any/all of the three drawers. CPU Trolly: The base is made of 1.6 mm thick CRCA and the sides are made of 1.2 mm thick. The width of the trolley can be varied to accompany various width CPU.The CPU is mounted on locable castors. Keyboard: Outer Dimension of keyboard tray is 507X245 mm made of |
| 5 | DC Manager/ IT Supervisor table : Size 1650X750X740, side table 1050X450X740, Pedestal 350X450X550, Back storage 1050X425X700 |
| 6 | Productivity work chair: Smart mid back,S1 Mechanism, T Fixed Arm, Nylon Base, Nylon Castor |
| 7 | Long Back Executive Chair: High Back, Synchro 1 mechanism, 1 D Arm,Nylon Base and Nylon castor |
| 8 | Designer type reception Desk: 20000 mm (w) x600mmwith1200mmhigh , 75mmthk. Customized with Glass Topwith arrangement of key board trays, cpu trollys, three drawer, etc. Complete as per customer |
| 9 | Conference ROUND TABLE: 25 Seater as per design approved by Engineer in charge |
| 10 | Sofa set with 3 + 2 seating arrangement along with Tea table |
| 11 | Shoe rack for 100 pairs shoes: 6’’ (h) x 10’’ (w) x 1’-0” (d) made from 19 mm BWR and termite proof board for frame/partition , back side made of 12 mm thick ply and duly painted with enamel paint,unique numbering on each box with enamel paint,second class teakwood corner beading andbottom of unit will have proper legs/stands/wooden |
| 12 | Lockers for keeping essentials for 100 Person: 1’- 0” (h) x 1’-0” (w) x 2’-0” (d) made from 19 mm BWR and termite proof board for frame/partition and shutters (single leaf shutter size 1ft. x 1ft.), back side made of 12 mm thick ply and duly painted with enamel paint, each shutter fixed with two numbers stainless steel butt hinges of 2.5” and a knob handle on each shutter with lock, stopper on inside face, unique numbering on each box with enamel paint, all exposed faces of wood work finished with veneer ply 1/8 inch thick and second class teakwood corner beading on front side and corners of shutter polished with Polyurethane (PU) polish, bottom of unit will have proper legs/stands/wooden |
| 13 | Fire Safe : Fire Safe ( 170Lts ) of Godrej make (model No-FR 1060) with hight 1060 mm, Width 450 mm & depth 355 mm for Media/ backup |
| 14 | Door Signage’s: vinyl cutting on acrylic base.(size : 12”x4”) |
| 15 | Data Centre Name plates: Data Centre Name plates/ Display Boards (3 Ft X 4 Ft Size) with decorative Light Fitting as per design approved by Engineer in charge |
| 16 | White Board: Size 4 Ft X 5 Ft with duster and proper floor mounting stands |
| 17 | Fire Escape Route Flow Diagram: A1 size |
| 18 | Fire Escape Exit Board |
| 19 | Stainless steel Water Cooler with nominal cooling capacity: stainless steel Water Cooler with nominal cooling capacity / storage capacity of 60/120litre/ Hrs |
| 20 | Tea/ Coffee Vending machine Triple Option that can Make Tea Coffee Soup & give Hot Water. Vending machine should have auto Water flushing After Selected Time Facility Digital Meter To Count No’s Of Drink Dispensed Display Water Level sensor |
| 21 | Modular Storage: depth 450mm*2500mm (with openable hinged doors at required intervals) with laminated finish on both inside and outside |
| 22 | Modular Control Desk for 01 monitors & 01 operator : Dimension: 750mm (H) X 750mm (W) X 900mm |
| 23 | 12mm thick frameless tempered clear glass Single door WITH 100mm Metal frame : Tempered glass is formed by heating glass to the softening point in a horizontal tempering stove, and then quickly cooling it. Properties: 1) Safety (tempered): when broken, it spits into tiny harmless pieces 2) Strong intensity: heat-strengthened glass is approximately twice as strong as annealed glass of the same thickness, andtempered glass is about 4 times 3) Outstanding performance in resisting thermal stress and wind-load 4) Tempered glass cannot be cut, drill hole and other further processed. |
| 24 | Round LED Ceiling light: High performance LED downlighter with high system efficacy for good quality and uniform lighting. Conforms to general lighting norms for office and other indoor applications |
| 25 | HT Panel - 11KV Gang operated Switch: complete in all respect with mounting structure |
| 26 | Transformer : 1250 KVA,11KV/433V, VectorsymbolDyn11, Z=6.25%,Delta/Star connected, ONAN,Ester oil type, 3Phase/3 Phase neutral, outdoor type Distribution transformerwithOLTC andcompletewithallstandard accessories,HTcablebox,suitable Flanges for 2000A Busduct on Secondarysideetc.Transformersshallbedesigned for 45 deg |
| 27 | Isolator Panel (2000Amp) (Schneider) 5 nos Relay – Master Relay (1 Nos.), Trip Circuit Relay (1 Nos.), VMR Relay (1 Nos.) and Earth Faulty Relay (2 Nos.). |
| 28 | LT Panel: 415V MAIN LT PANEL, suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc |
| 29 | Row Power Panal: 250A, 4P 30 KA, MCCB having Electronic Trip Unit with adjustable protection against Overload and Short Circuit |
| 30 | PAC Panel: 400A, 4P 30 KA, MCCB having Electronic Trip Unit with adjustable protection against Overload and Short Circuit |
| 31 | UPS Output PDU Panel: 630A, 4P 15 KA, MCCB having Electronic Trip Unit with adjustable protection against Overload and Short Circuit |
| 32 | VRV Panel: 160A, 4P 25 KA, MCCB having Electronic Trip Unit with adjustable protection against Overload and Short Circuit. 1No – Load Manager with Modbus over RS 485 Interface with Maximum Demand Indication of EM 6400 or equivalent. 1Set – 160/5A, Class 1.0, 15VA for metering,CL.PS, 15VA for protection Cast Resin CTs |
| 33 | Emercency Panel: 63A, 4P 25 KA, MCCB having Thermal magnetic release with adjustable thermal setting INCOMER Metering for each incomer |
| 34 | Isolation Transformer Panel: 300kVA K13 isolation transformer OUTGOING |
| 35 | LiftPanel: 100A, 4P MCCB having Thermal magnetic release with adjustable thermal setting Metering for Incomer |
| 36 | APFCR Panel – 450KVAR: Auto Power Factor Correction Relay (APFCR-450KVAr with 5 stage rating 4x100 KVAr + 1x50 KVAr design as per IEC 61921, IEC 61439-1 & 2)suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, bus duct flange for incomer, gland plates at top/bottom for control cables, complete with internal wiring, ferrules, name plates, painting etc |
| 37 | Auto Transfer Switch 100A,415V,4P: Powder coated Enclosure with IP 55 100A,415V,4P,Auto TransferSwitchhousedinweatherproof, CRCA Sheet / MSBox powdercoatedenclosuremounted onMSsupportnearthe pumps suitableforOutdoor application of IP55.ATS should be able to accommodate 4C X 35 SQMM CU ARM cable on load side as per SLD and all complete as per drawings |
| 38 | Auto Transfer Switch 40A, 415V, 4P: weather proof, CRCA Sheet / MS Box enclosure mounted on wall near the PAHUs suitable for Indoor operation as per SLD. (Powder coated with IP55 protection) and all complete as per drawings |
| 39 | Auto Transfer Switch 63A, 415V, 4P: weather proof, CRCA Sheet / MS Box enclosure mounted on wall near the PAHUs suitable for Indoor operation as per SLD. (Powder coated with IP55 protection) and all complete as per drawings |
| 40 | DG Sync Panel: 415V DG SYNC PANEL -1, suitable for 415Volts 3Phase 4wiresystem, fabricated from 14/16SWG CRCA sheet steel, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top/bottom, complete with internal wiring, ferrules, name plates, painting etc |
| 41 | 40W Surface mounted LED light fixture 2 feet X 2 feet |
| 42 | Occupancy sensor range 6-7 meter |
| 43 | 3ø, 8Way, Phase segregated DB (Lighting DB): Incomers 1No. 63A, 4P, MCB ‘C’ Curve Phase outgoing 3Nos. 63A, 30mA, DP, RCCB 12Nos. Of outgoing 6A SP MCB With ‘C’ Curve 12 Nos. Of outgoing 16A SP MCB With ‘D’ Curve |
| 44 | 3ø, 8Way, Phase segregated DB (Raw power DB): Incomers 1No. 100A, 4P, MCB ‘C’ Curve Phase outgoing 3Nos. 100A, 30mA, DP, RCCB 12Nos. Of outgoing 6A SP MCB With ‘C’ Curve 12 Nos. Of outgoing 16A SP MCB With ‘D’ Curve |
| 45 | 1250 kVA Transformer earthing |
| 46 | 750KVA DG Set earthing |
| 47 | Lightning arrestor earthing |
| 48 | UPS/PDU system earthing |
| 49 | Rack earthing |
| 50 | HT Panel earthing |
| 51 | LT Panel earthing |
| 52 | Lightning arrestor enchanching type designed to attract lightning: Lightning arrestor enchanching type designed to attract lightning from a predetermined volume and to safety convey the lightning current to the earth and complaint UL-96 or Equivalent to NFC 17102 ESE type (Nimbus) and complete with following principle components.(The lightining icropro should cover 107Meter radius and as per Site requirement) & Air termination shall be non-corroding and centre earthed finials shall be 300mm in cross section and be made of electric grade non ferrous material |
| 53 | Round bottomed fire buckets filled with river sand |
| 54 | Shock treatment chart in English & Hindi languages laminated/ glass framed |
| 55 | 11KVDanger boards |
| 56 | 440V Danger boards |
| 57 | First aid box containing full compliment of medicines, ointments & bandages |
| 58 | Single line drawing duly laminated / framed in A1 size |
| 59 | 60X40CM teak wood box with glass door & hooks for hanging keys & space for keeping hand gloves complete with lock & three keys |
| 60 | 300 KVA/KW UPS: IGBT based rectifier to achieve input THDI < 3% and input power factor of greater than 0.99 at 100% loading. True Online Double Conversion (VFI as per IEC 62040-3) UPS usingPWM IGBT technology, 3 Phase input and 3 phase 415 V output UPS system |
| 61 | 40 KVA UPS with 3 phase input and 3 phase output: 3 phase input and 3 phase output and as per the Technical specifications. Quoted rate shall be inclusive of required batteries of 15 minutes back up at full load, battery shall be with connecting cables, Battery rack and all complete as per drawings, technical specifications, SLD, relevant standards |
| 62 | DG Sets 750 KVA: 3 phase 415 volts 50 cycle per second 1500 RPM Radiator cooled Diesel Generator Sets of rating as below. The engine shall include flywheel to suit flexible coupling with guard, air cleaner, blower fan, fuel pump, variable speed electronic governor, fuel filter, lub oil filter & pump, primary water circulating pump, battery charger, 24 volt batteries of compatible capacity with battery stand and instrument panel comprising of switch with key |
| 63 | 12 Hours running capacity bufferFuel Tank: receive fuel oil from bulk oil storage tank, fabricated from 2 mm thick M.S. sheets including the cost of removable cover with locking arrangement and including the cost of painting and including the cost of providing all the required appurtenances like inlet and outlet connections including the cost of flanges & fittings, float valve, foot valve, drain connection, over flow connection to oil sump etc. and including the cost offuel level sensors with high and low level visual indication and audible alarms with actuators to automatically start and stop the fuel |
| 64 | semi rotary hand pump for filling fuel |
| 65 | NO SMOKING & DANGER ZONE sign boards |
| 66 | CO2 4.5 kg capacity as per IS:2878 |
| 67 | Fire Extinguisher Chemical foam type of 9 litre |
| 68 | Fire Extinguisher Dry chemical powder type IS : 2171 5 kg |
| 69 | Precision Air Conditioning System (26 TR ):microprocessor based precision Air Conditioning units for the Server room.The unit shall be complete with incoming MCCB, InverterDigital / Tandem / scroll compressor ,cooling coil DX type, with EEV, EC drive with plug fan, microprocessor panel, air filter, electrical reheat, built in sequential controller, air-cooled condenser |
| 70 | Precision Air Conditioning System (9.5 TR): microprocessor based precision Air Conditioning units for the Server room.The unit shall be complete with incoming MCCB, InverterDigital / Tandem / scroll compressor ,cooling coil DX type, with EEV, EC drive with plug fan, microprocessor panel, air filter, electrical reheat, built in sequential controller, air-cooled condenser |
| 71 | VRV Based Air Conditioning: MULTI-VRF units complete with 100% Inverter driven scroll compressor, air cooled condenser with Inverter driven icropro speed fan motor having interconnected control wiring and refrigerant piping housed in compact housing duly powder coated body. 22 HP (Cooling-Only) 52 Deg.Operation |
| 72 | Indoor Comfort AC units: 4-Way Cassatte Unit (3TR) |
| 73 | Indoor Comfort AC units: MSP Ductable (4.6TR) |
| 74 | Indoor Comfort AC units: Hi-Wall (1TR) |
| 75 | Indoor Comfort AC units: Hi-Wall (1.5TR) |
| 76 | Indoor Comfort AC units: Wireless Remote |
| 77 | Wired Remote |
| 78 | Centralize Remote(Touch Type) |
| 79 | UL listed Server Racks: Size - Minimum. 600 mm (W) x 1200 mm (D) Height - 42 U |
| 80 | UL listed Server Racks: Size - Minimum. 800 mm (W) x 1200 mm (D) Height - 42 U |
| 81 | Telco Rack for MUX and Hub Room |
| 82 | Cold Aisle Containment System |
| 83 | Fire Alarm Panel with Network Interface Card (2 Nos.), Telephone Zone Card 1 Nos.), Zone Indication Card (1 Nos.), Digital Audio Card (1 Nos.), Device Loop Card (2 Nos.) and with accessories (Siemens) |
| 84 | Repeater Panel including display of minimum of 80 characters |
| 85 | Multi Sensor smoke detector |
| 86 | Fixed temperature cum rate of rise heat detector: UL Listed Fixed temperature cum rate of rate of rise heat detector with mounting based LED, Address Switch / electronic way of addressing, as per technical specifications and all requirements of contract works |
| 87 | Dual action (push IN-pull DOWN) Flush or surface mounted Manual Call Point |
| 88 | Addressable hooter cum strobe units, wall mounted |
| 89 | Fire telephone jacks with telephone module complete7 |
| 90 | Heavy duty recessed / surface mounted telephone hand set complete |
| 91 | Monitor Module for MCP, VESDA & WLD Panels |
| 92 | Control Module for hooter cum strobe and Gas Release Panel |
| 93 | Relay Module |
| 94 | Isolator Module |
| 95 | BACNET Card for Networking |
| 96 | 6 Watt Ceiling mount Speaker with junction box for ceiling mount |
| 97 | 15 Watt Wall mount Speaker |
| 98 | 240 Watts Booster amplifier |
| 99 | 480 Watts Booster amplifier |
| 100 | Voice Alarm controller Goosneck micro Phone |
| 101 | USB/CD/MP3 Player |
| 102 | 6 Zone Selection panel for PA announcement |
| 103 | Rack to mount amplifier, CD player and console |
| 104 | NVR: suitable power socket, DC power converters, connectors, cables, etc. complete as per spec. Contractor to decide on the NVR size depending on the Pixel resolution and recording rate in frames per second as specified in the tender. Contractor shall size the NAS for 25 FPS / 4 CIF resolution 90 days of recording and submit data sheet of their storage calculation for both MPEG 4 and JPEG recording formats and submit data sheet of their storage calculation for both MPEG 4 and H.264 recording formats. Note: Each Minimum of 20 Chanel Capacity |
| 105 | Large wall mount LCD screens |
| 106 | Emercency Door Releaser |
| 107 | Access card readers |
| 108 | Proximity cards |
| 109 | Break Glass Unit for Access Doors |
| 110 | BIOMETRIC Finger Reader |
| 111 | Electromagnet door holder - Single Leaf Door |
| 112 | Electromagnet door holder - Double Leaf Door |
| 113 | Door Contact |
| 114 | Card Printer |
| 115 | Rodent Satellites (Streem) |
| 116 | VESDA |
| 117 | Fire Suppression System |
| 118 | Master Cylinder Kit |
| 119 | End Slave Cylinder |
| 120 | El Check 2” (Manifold Check Valve) |
| 121 | Gas Discharge Nozzles |
| 122 | Abort Switch |
| 123 | Release Switch |
| 124 | Water Leak detection panel (4 zone ) |
| 125 | Outside T/Rh sensor |
| 126 | Room T/Rh sensor |
| 127 | 8 port managed non POE Switches |
| 128 | 20 port managed POE switches |
| 129 | FixedtypeDelegate unit |
| 130 | FixedtypeChairmanunit |
| 131 | Fixed Dome Camera: CCTV including Networking items such as Switches, Patch Panel, LIU, Patch-cords etc.Required for the completeness of system as per the building drawing attach with RFP |
| 132 | PTZ Camera: Outdoor IP based Pan/Tilt/Zoom cameras, ½.9” Progressive Scan CMOS or better, image resolution 1920 x 1080 or better @ 25 FPS, Electronic shutter -1/28000 sec to 1 sec or better,including integrated Housing (dome type), Connectors, Lens, Camera Mounting poles and all Ancillary Equipment& all accessories (including driver cables , Power Supply unit & pan tilt unit) |
| 133 | DCIM (Athenta Technology) |
| 134 | Data Centre Infrastructure Management software per rack perpetual license for 80 Racks and as per RFP specification. |
| 135 | DCIM Server |
| 136 | AOMS Server |
| 137 | Fascia Server |
| 138 | DDC Panel (Siemens) |
| 139 | DDC Panel (Cabinet) |
| 140 | RS 232 TO 485 Modules (Model Number: TX12-S.OPEN): The RS232/485 module integrates third-party systems via RS232 or RS485 interface to the Desigo building automation and control system. TXI2.OPEN supports up to 160 data points. The module status LED (green) indicates the status of the module. |
| 141 | System Controller (Model Number: PXC001-E. D): Mapping and monitoring of third-party disciplines as HVAC. The system controllers provide the infrastructure to hold and execute the system and application specific functions. The module status LED (green) indicates the status of the module. Use network interface RJ45 for (BACnet / IP, PXC001-E.D) only. System-Controller for the integration of KNX, M-Bus, Modbus or SCL over BACnet/IP. |
| 142 | Digital Input Module (Model Number: TXM1.16D): A digital signal is a signal that exists in one of two states: high or low, open, or closed, on or off. A digital input/output (DIO) device is hardware that sends or receives these digital signals. Available 16 inputs in TXM1.16D, each with a green LED. |
| 143 | Power Supply Module (Model Number: TXS1.12F10): The device converts and supplies electricity of the required voltage and frequency, excluding noise from the electricity obtained from an electrical outlet. Power supplies are classified by applications for available DC, AC, and output voltage ranges. DC 24 V for the supply of I/O modules and field devices (generated in an internal AC/DC converter) |
| 144 | Bus Connection Module (Model Number: TXS1.EF10): Transfer of DC 24 V for the supply of TX series modules and field devices. AC / DC 12...24 V for the supply of field devices. |
| 145 | Universal Module (Model Number: TXM1.8U): All terminals are directly on the I/O modules, allowing direct connection of field devices without additional terminal strips. Support of signal types and functions in different building automation and control systems. Provide 8 inputs/outputs with LED signal / fault indication. |
| 146 | Relay Module (Model Number: TXM.1.6R): The relay module function is mainly to switch electrical devices and systems on or off. It also serves to isolate the control circuit from the device or system being controlled. Available 6 volt-free relay outputs.Individual I/O point signalling with green I/O status LED. |
| 147 | Automation Station Module (Model Number: PXC200-E. D): Freely programmable modular automation stations for HVAC and building services plants. Comprehensive management and system functions (alarm management, time schedules, trends, access protection. High performance and reliable operation. |
| 148 | Building Management System |
| 149 | Access Control unit with accessories (HID) |
| 150 | Bio-metric Workstation, (Dell) |
| 151 | Access Control Software (Security View & Morpho Manager) |
| 152 | Door Contacts, (HID) |
| 153 | Access Management Software with Time & Attendance Software (HR View) |
| 154 | PTZ Camera Joystick, (Dahua) |
| 155 | Web Application for CCTV, (Smart PSS- Dahua) |
| 156 | Rodent Repellent Panel with Stand and Bracket, (Jay Fire System) |
| 157 | WLD Electronic Hooter |
| 158 | WLD Module (SIM) |
| 159 | WLD Sensor Cable |
| 160 | Building Management System Software (Desigo CC- Siemens) |
| 161 | Energy Meter Single Phase (Tap-up Box) (Starline) |
| 162 | Energy Meter Three Phase (Tap-up Box) (Starline) |
| 163 | Server Room BBT with End Feed Unit (Starline) |
| 164 | Laser jet Printer 1108 (HP) |
| 165 | Laser Jet Pro MFP M181fw (HP) |
| 166 | Lighting and Power Wiring (As installed) |
| 167 | Upkeep and Maintenance of standard wiring electrical points including Wires, sockets/switches (6 Amps, 16 Amps & 32 Amps). (As installed) |
| 168 | Power Wiring: Upkeep and Maintenance of standard wiring electrical points including cables from LT Panel to Raw Power Panel, UPS, Emergency Panel, PAC Panel, VRV Panel and APFC Panel & from UPS to PDU Panel. (As installed) |
| 169 | Asset Management (RF Code) |
| 170 | Asset & Environment Management Software (CenterScape) |
| 171 | Temperature & Humidity Sensor |
| 172 | Single Phase IPDU (Server Technologies Inc.) |
| 173 | Three Phases IPDU (Server Technologies Inc.) |
| 174 | Rack Locator |
| 175 | Reader (6 Installed in Server Room & 1 Installed in Store- room) |
| 176 | Asset - Inventory Tags |
| 177 | BBT (3 Phase – 2000 Amp) from Isolator Panel to Both LT Panel, from DG set to DG Sync Panel and DG Sync Panel to LT Panel (Schneider) |
| 178 | Modular Wall Panel (Installed in Development and NOC Room) (Pyrotech) (As installed) |
| 179 | Response Indicator, (Agni) |
| 180 | Ring Main Unit (11KVA) (Schneider) |
| 181 | Iron Gate |
| 182 | Center Table |
| 183 | Vacuum Cleaner(Shakti) |
| 184 | Drawer |
| 185 | File Desk |
| 186 | Almirah |
| 187 | Air Booster Fan (Stulz) |
| 188 | Air Extractor (Stulz) |
| 189 | Air Modulator (Stulz) |
| 190 | OM4, Bend Insensative, Pre-terminated Trunk Cable, 24-Fiber LSZH, 13 Meters |
| 191 | OM4, Bend Insensative, Pre-terminated Trunk Cable, 24-Fiber LSZH,10 Meters |
| 192 | OM4, MPO Cassette, 24 LC fibers (12 duplex ports) |
| 193 | 2U UD Shelf / Panel, accepts 12 MPO Cassettes |
| 194 | 1U HD Shelf / Panel, accepts 12 MPO Cassettes |
| 195 | 1U Sliding modular cassette shelf, accepts 4 MPO cassettes |
| 196 | Network Control Station |
| 197 | Sounder with Strobe (Hooter) |
| 198 | Control Unitfor Conference Room |
| 199 | Industrial Socket |
| 200 | eSign Project |
| 201 | Access Control with Software (4-DOOR_ACCESS_CTRL) |
| 202 | Access Control (FINGERPRINT_ACCESS) (ESSL) |
| 203 | Access Control (FACE_DETECTION_ACCESS) (ESSL) |
| 204 | Access CONTROL (ESSL) |
| 205 | DVR (Hikvision) |
| 206 | LED_TV (MICROMAX) |
| 207 | IRON CAGE(400 sq. Feet approx) (As installed) |
| 208 | Fixed Dome Camera (Hikvision) |
| 209 | Push Button for Exit (Access Control) |
| 210 | ESSL EM Lock |
| 211 | Other Items |
| 212 | Lift (Thyssenkrupp) |
| 213 | Hanging Wall Fan (Crompton) |
| 214 | Cabinettype Rectangular Inline fans with motor complete with TEFC Sq. Cage Inductionmotor suitable for 220 volts ± 10%,50Hz ± 3 %, single phase A.C |
| 215 | Cooling only 5 HP Capacity (Side Discharge)ITC of VRF OEM manufactured treated fresh air unit (TFA) equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, insulated drain pan, pipe connections etc. |
| 216 | 4.12 TR/741 CFM TFA Unit with wired remote |
| 217 | Outdoor cubicle type totally enclosed free standing double door type dust & vermin proof Kiosk Panel for outdoor application made out of 2.0 mm thick and partition made out of 1.6 mm MS sheet steel, suitable for 3 phase , 4 wire , 415 V , 50 Hz , AC supply complete with incoming ACB / MCCB / SFU & outgoing MCB / MCCB / SFU , All the MCCB should be with Rotary handle, Four Pole Electrolytic grade- INCOMER100 Amp, FP,25 KA, MCCB having Thermal Magnetic release with short circuit and adjustable overload (0.7 to 1In ) protection - 1 no, BUSBAR 200 Amp, FP,Electrolytic grade Al busbar for mainMCB outing & feeders distribution, OUTGOING25Amp, FP, C curve, 10 KA BC MCB - 1 nos, 25Amp, FP, AC1 utilisation catagary power contactor, having 415 volt operating auxiliary coil fitted with suppressor & 2NO+2NC block - 1 nos, 40Amp,FP, C curve, 10 KA BC MCB - 02 nos6Amp, SP, C curve, 10 KA BC MCB - 11 nos, Digital Time Switch with 2 Amp MCB for time switch bypass Arrangement- 1 nos, A software for communication, duly protected by 2A MCB - 1 nos, LED type RYB indication lamp duly protected by 2A MCB– 3 Nos. |
| 218 | Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity - 6KG. . |
| 219 | Supply & Installation of Manager Table (1500x750x770 (LxBxH)) |
| 220 | Supply and erection of pole lighting stell tubular swaged type with decorative pole conforming IS 2713-1980, pole designation 410 SP 15, 6.0 meter long with cast iron base plate drilling of 1\" dia hole on the upper portion of the pole for the installtion of street light and 1\" dia hole on the lower portion of the pole for cableentry of the wire base pole paintng of red oxide and two coats of silver white aluminium paint. |
| 221 | SITC of 12mm thick Frameless tempered clear glass (Toughened Glass) Single Door Size: - 1200mm X 2400mm With door spring and locking arrangements and both way handle and patch fittings. |
| 222 | Single Leaf Non Fire Rated wooden Door withVision Panel |
| 223 | Wooden Door withVision Panel |
| 224 | Single Leaf Glass Door with thin semi transparent Film/laminate |
| 225 | Glass Door with 12 mm toughened glass, floor spring, arrangement for access control, handle, lock etc. complete 1000mm X2100mm |
| 226 | Wooden Door with locks |
| 227 | Glass Door toughened glass, floor spring, arrangement for access control, handle, lock etc |
| 228 | Water Motor Pump (1.5 HP) (Aqua Group) |
| 229 | Overhead Water Tank (Capacity 5000 Litre – 1 Nos) (Prince), (Capacity 500 Litre – 4 Nos) (Nircon) with sanitary and plumbing work |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail